Search NASA⌕ Search

SEARCH · Search NASA

Results for “code requirements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Toughness Testing for Liquid Hydrogen And Helium Temperatures - Validation of Austenitic Stainless Steels for 4K (-452F) Use

This presentation is an Existing Code Requirement: Charpy impact test at a temperature no higher than the design minimum temperature. The Current Practice: is not clear, the indications are that testing is sometimes performed at -320F (liquid nitrogen or "LN2") for that and all lower temperatures. In some cases testing is probably not performed and CGA indicated successful operation of systems at -453F without required test. The Ballot activity: C&S Connect Record 13-341, Ballot 13-1746, initially proposed Charpy testing (lateral expansion criteria) at -320F to validate use at -425 (liquid helium or "LHe"). and PTCS Proposal..

Greulich, Owen R.↗

Improving Security of Ground System Software

An estimated 84% of all security breaches are application-related, not firewall violations. To what extent is your organization focused on addressing security issues in its software? Software plays a critical role in mission success, and software similarly plays a role in mission security. However, software can introduce vulnerabilities to the system, such as use of a COTS product that has a backdoor, or a hole in the security of the system deliberately left in place by designers or maintainers. The motivations for such holes are not always sinister, but can provide a means for malicious intrusion into the mission. Students will learn an approach to securing ground software within the context of federal information systems. Federal requirements, coding standards, tool usage will be discussed as part of the solution to securing software.

Bailey, Brandon↗

Online Visualization and Analysis of NASA Satellite-Based Global and Regional Precipitation Products Through Giovanni

Observational data are essential for Earth science research and applications. Traditional ground-based observations suffer from many limitations (e.g. costly deployment). As a result, data are often sparse and inconsistent, especially over vast oceans that cover nearly 71% of the Earth's surface, and for remote continents. Precipitation is one of the important physical parameters in the global hydrological cycle and other disciplines. Each year, severe floods and droughts happen in different parts of the world and cause significant damage to the economy, as well as human casualties (e.g. Hurricane Katrina, the Dust Bowl). Accurate and timely precipitation observations and predictions are important for research and applications. However, ground-based precipitation observations are quite limited, especially in remote and mountainous regions. Since the satellite era began, satellite-based precipitation products have gained popularity in Earth science research, applications, and education. Accessing satellite products can be a daunting task to many users, especially those who do not have prior experience or knowledge with satellite data. Recognizing this obstacle, the NASA Goddard Earth Sciences and Data and Information Services Center (GES DISC), home to data archives for the NASA-JAXA Tropical Rainfall Measuring Mission (TRMM) and Global Precipitation Measurement (GPM), has developed data services including an online visualization and analysis tool, Giovanni (the Geospatial Interactive Online Visualization ANd aNalysis Infrastructure), enabling users at different levels to access, explore, and evaluate NASA satellite-based data products without downloading either data and software, or requiring coding. Currently, global and regional precipitation products from different satellite missions (TRMM, GPM) and projects (e.g. the Modern Era Retrospective-analysis for Research and Applications Version 2 (MERRA-2), and the North American Land Data Assimilation System (NLDAS)), ranging from half-hourly to monthly temporal resolution, are available in Giovanni. There are over 1900 variables in Giovanni, covering measurements in precipitation, hydrology, atmospheric dynamics, atmospheric chemistry, etc. In this poster presentation, we will provide a live demonstration of Giovanni and its latest development, including precipitation-related variables, and new basic features such as polar projections. The session will also provide a Q&A opportunity for attendees.

Giovanni↗

TPSAS-NF1676L-14662-DND

In this presentation, the development of the benchmark cases for the assessment of the static delamination propagation as well as the onset and growth prediction capabilities are presented. Examples of automated propagation and growth analyses are shown with a focus on mode II fracture and the simulation of the three-point bending End Notched Flexure (ENF) specimen. Further the selection of the required code specific input parameters are discussed. The current capabilities are summarized while remaining difficulties and future challenges are also highlighted.

Ronald Krueger↗

Performance and Portability of a Linear Solver Across Emerging Architectures

A linear solver algorithm used by a large-scale unstructured-grid computational fluid dynamics application is examined for a broad range of familiar and emerging architectures. Efficient implementation of a linear solver is challenging on recent CPUs offering vector architectures. Vector loads and stores are essential to effectively utilize available memory bandwidth on CPUs, and maintaining performance across different CPUs can be difficult in the face of varying vector lengths offered by each. A similar challenge occurs on GPU architectures, where it is essential to have coalesced memory accesses to utilize memory bandwidth effectively. In this work, we demonstrate that restructuring a computation, and possibly data layout, with regard to architecture is essential to achieve optimal performance by establishing a performance benchmark for each target architecture in a low level language such as vector intrinsics or CUDA. In doing so, we demonstrate how a linear solver kernel can be mapped to Intel® Xeon™ and Xeon Phi™, Marvell® ThunderX2®, NEC® SX-Aurora™ TSUBASA Vector Engine, and NVIDIA® and AMD® GPUs. We further demonstrate that the required code restructuring can be achieved in higher level programming environments such as OpenACC, OCCA, and Intel® OneAPI™/SYCL, and that each generally results in optimal performance on the target architecture. Relative performance metrics for all implementations are shown, and subjective ratings for ease of implementation and optimization are suggested.

Programming models↗

Weld Repair of a Stamped Pressure Vessel in a Radiologically Controlled Zone

In September 2012 an ASME B&PVC Section VIII stamped pressure vessel located at the DOE Hanford Site Effluent Treatment Facility (ETF) developed a through-wall leak. The vessel, a steam/brine heat exchanger, operated in a radiologically controlled zone (by the CH2MHill PRC or CHPRC), had been in service for approximately 17 years. The heat exchanger is part of a single train evaporator process and its failure caused the entire system to be shut down, significantly impacting facility operations. This paper describes the activities associated with failure characterization, technical decision making/planning for repair by welding, logistical challenges associated with performing work in a radiologically controlled zone, performing the repair, and administrative considerations related to ASME code requirements.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Appurtenance Influence on Type III Hanford Single-Shell Tank Structural Integrity

The interim stabilized Hanford Single Shell Tanks (SSTs) are currently undergoing a state of the art analysis to assess the structural integrity of the waste storage tanks, for cleanup and closure operations, considering their adverse thermal histories and an updated seismic hazard for the Hanford Site near Richland, Washington. The SSTs contain a variety of ancillary pits, piping, piping supports, risers, equipment, and penetrations known as appurtenances. These appurtenances may alter the structural response and ultimately could affect the structural integrity of the SSTs. An important challenge to the structural analysis of the SSTs is determining the impact of these appurtenances on structural integrity. To achieve this, the various appurtenances were reviewed and bounding appurtenance configurations for SST Types II and III tank designs were analyzed using finite element software. The bounding configurations for the Type II tanks considered four heavy offset pits with a central pit with and without a 36-inch diameter central post-construction penetration and four 42-inch diameter offset penetrations. The bounding configuration for the Type III tanks is a tank with two heavy offset pits and one heavy central pit. For each bounding configuration two finite element models are developed: a seismic analysis model and a thermal and operating loads analysis (TOLA) model. The TOLA models include a Type II or III thermal history, concrete cracking and thermal degradation, reinforcement yielding, and soil plasticity. Additionally, operating loads such as internal waste pressure and concentrated and distributed soil surface loads are applied to the TOLA model. The seismic model treats the tank concrete as linear elastic based on the present day degraded concrete properties. Also, in the seismic model the soil is treated as linear elastic while special techniques are used in the soil above the tank dome and along the tank wall to avoid soil arching and achieve the proper soil pressure on the tank walls. Seismic time histories (in the horizontal and vertical directions) are applied to the seismic model. The American Concrete Institute (ACI) has code requirements for nuclear safety-related concrete structures (ACI-349-06) that are used to evaluate the structural integrity of the SSTs. ACI-349-06 recommends evaluating factored load combinations against reduced tank section capacities to account for both loading and material uncertainties. From both the TOLA and seismic models the structural demands (forces and moments) are extracted from sections throughout the tank under the appropriate load combinations. These demands are compared against the ACI-349-06 capacities at each of the sections. This ratio of demand to capacity is reported as a measure of structural integrity. The Type II and Type III appurtenances configurations are found to increase the demand to capacity ratios in local regions near the appurtenances. Away from the appurtenances the influence on structural integrity is minor. A comparison of the Type II and III results show that even though the Type II offset pits weight less, they have a larger impact on the structural integrity of the tanks due to their locations. Finally, lessons learned from the Type II and Type III appurtenance analysis, and their application to the more complex Type IV structural integrity analysis, will be discussed.

appurtenances↗

Achieving 50% Energy Savings in New Schools, Advanced Energy Design Guides: K-12 Schools (Brochure)

This fact sheet summarizes recommendations for designing elementary, middle, and high school buildings that will result in 50% less energy use than conventional new schools built to minimum code requirements. The recommendations are drawn from the Advanced Energy Design Guide for K-12 School Buildings, an ASHRAE publication that provides comprehensive recommendations for designing low-energy-use school buildings (see sidebar). Designed as a stand-alone document, this fact sheet provides key principles and a set of prescriptive design recommendations appropriate for smaller schools with insufficient budgets to fully implement best practices for integrated design and optimized performance. The recommendations have undergone a thorough analysis and review process through ASHRAE, and have been deemed the best combination of measures to achieve 50% savings in the greatest number of schools.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Achieving 50% Energy Savings in Office Buildings, Advanced Energy Design Guides: Office Buildings (Brochure)

This fact sheet summarizes recommendations for designing new office buildings that result in 50% less energy use than conventional designs meeting minimum code requirements. The recommendations are drawn from the Advanced Energy Design Guide for Small to Medium Office Buildings, an ASHRAE publication that provides comprehensive recommendations for designing low-energy-use office buildings with gross floor areas up to 100,000 ft2 (see sidebar). Designed as a stand-alone document, this fact sheet provides key principles and a set of prescriptive design recommendations appropriate for smaller office buildings with insufficient budgets to fully implement best practices for integrated design and optimized performance. The recommendations have undergone a thorough analysis and review process through ASHRAE, and have been deemed the best combination of measures to achieve 50% savings in the greatest number of office buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Building America Case Study: Initial and Long-Term Movement of Cladding Installed Over Exterior Rigid Insulation (Fact Sheet)

Changes in the International Energy Conservation Code (IECC) from 2009 to 2012 have resulted in the use of exterior rigid insulation becoming part of the prescriptive code requirements. With more jurisdictions adopting the 2012 IECC builders are going to finding themselves required to incorporate exterior insulation in the construction of their exterior wall assemblies. For thick layers of exterior insulation (levels greater than 1.5 inches), the use wood furring strips attached through the insulation back to the structure has been used by many contractors and designers as a means to provide a convenient cladding attachment location. However, there has been a significant resistance to its widespread implementation due to a lack of research and understanding of the mechanisms involved and potential creep effects of the assembly under the sustained dead load of a cladding. This research was an extension on previous research conducted by BSC in 2011, and 2012. Each year the understanding of the system discrete load component interactions, as well as impacts of environmental loading has increased. The focus of the research was to examine more closely the impacts of screw fastener bending on the total system capacity, effects of thermal expansion and contraction of materials on the compressive forces in the assembly, as well as to analyze a full years worth of cladding movement data from assemblies constructed in an exposed outdoor environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: Initial and Long-Term MOvement of Cladding Installed Over Exterior Rigid Insulation

Changes in the International Energy Conservation Code (IECC) from 2009 to 2012 have resulted in the use of exterior rigid insulation becoming part of the prescriptive code requirements. With more jurisdictions adopting the 2012 IECC, builders will be required to incorporate exterior insulation in the construction of their exterior wall assemblies. For thick layers of exterior insulation (levels greater than 1.5 inches), the use of wood of furring strips attached through the insulation back to the structure has been used by many contractors and designers as a means to provide a convenient cladding attachment location. However, there has been resistance to its widespread implementation due to a lack of research and understanding of the mechanisms involved and potential creep effects of the assembly under the sustained dead load of a cladding. This research conducted by Building Science Corporation evaluated the system mechanics and long-term performance of this technique.

BSC↗

Tomcat, Oracle & XML Web Archive

The TOX (Tomcat Oracle & XML) web archive is a foundation for development of HTTP-based applications using Tomcat (or some other servlet container) and an Oracle RDBMS. Use of TOX requires coding primarily in PL/SQL, JavaScript, and XSLT, but also in HTML, CSS and potentially Java. Coded in Java and PL/SQL itself, TOX provides the foundation for more complex applications to be built.

Cothren, D. C.↗

Empirical Profiling of Cold Hydrogen Plumes Formed from Venting Of LH2 Storage Vessels: Preprint

Liquid hydrogen (LH2) storage is a viable approach to assuring sufficient hydrogen capacity at commercial fuelling stations. Presently, LH2 is produced at remote facilities and then transported to the end-use site by road vehicles (i.e., LH2 tanker trucks). Venting of hydrogen to depressurize the transport storage tank is a routine part of the LH2 delivery process. The behaviour of cold hydrogen plumes has not been well-characterized because empirical field data is essentially non-existent. The NFPA 2 Hydrogen Storage Safety Task Group, which consists of hydrogen producers, safety experts, and CFD modellers, has identified the lack of understanding of hydrogen dispersion during LH2 venting of storage vessel as a critical gap for establishing safety distances at LH2 facilities, especially commercial hydrogen fuelling stations. To address this need, the NREL sensor laboratory, in collaboration with the NFPA 2 Safety Task Group developed the Cold Hydrogen Plume Analyzer to empirically characterize the hydrogen plume formed during LH2 storage tank venting. A prototype Analyzer was developed and field-deployed at an actual LH2 venting operation with critical findings that included: - H2 being detected as much as 2 m lower than the release point, which is not predicted by existing models - A small and inconsistent correlation between oxygen depletion and the hydrogen concentration - A negligible to non-existent correlation between in-situ temperature and the hydrogen concentration The Analyzer is currently being upgraded for enhanced metrological capabilities including improved real-time spatial and temporal profiling of the plume and tracking of prevailing weather conditions. Additional deployments are planned to monitor plume behaviour under different wind, humidity, and temperatures. This data will be shared with the NFPA 2 Safety Task Group and ultimately will be used support theoretical models and code requirements prescribed in NFPA 2.

30 DIRECT ENERGY CONVERSION↗

The International Experimental Thermal Hydraulic Systems database – TIETHYS: A new NEA validation tool

Nuclear reactor codes require validation with appropriate data representing the plant for specific scenarios. The thermal-hydraulic data is scattered in different locations and in different formats. Some of the data is in danger of being lost. A relational database is being developed to organize the international thermal hydraulic test data for various reactor concepts and different scenarios. At the reactor system level, that data is organized to include separate effect tests and integral effect tests for specific scenarios and corresponding phenomena. The database relies on the phenomena identification sections of expert developed PIRTs. The database will provide a summary of appropriate data, review of facility information, test description, instrumentation, references for the experimental data and some examples of application of the data for validation. The current database platform includes scenarios for PWR, BWR, VVER, and specific benchmarks for CFD modelling data and is to be expanded to include references for molten salt reactors. There are place holders for high temperature gas cooled reactors, CANDU and liquid metal reactors. This relational database is called The International Experimental Thermal Hydraulic Systems (TIETHYS) database and currently resides at Nuclear Energy Agency (NEA) of the OECD and is freely open to public access. Going forward the database will be extended to include additional links and data as they become available. https://www.oecd-nea.org/tiethysweb/

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗