Search NASA⌕ Search

SEARCH · Search NASA

Results for “conditional generative models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Planetesimal Impact Vapor Plumes and Nebular Shocks Form Chondritic Mixtures

The origin of chondrules and the chondritic sedimentary rocks that dominate the meteoritic record is a long-standing problem in planetary science. Here, we develop a physical model for the formation of chondritic mixtures as an outcome of vaporizing collisions between planetesimals that were dynamically excited by the growth and migration of planets. We present calculations of nebular shock waves generated by impact vapor plumes and focus on aspects of the plume interaction with the nebular gas and dust that have been neglected in previous studies of impact ejecta. We find that when water dominates the vapor, the plumes are relatively cool. However, the plume expansion is supersonic and can drive strong shock waves in the dusty nebular gas. Portions of these nebular shock fronts initially melt nebular dust, forming chondrules that are coupled to the moving front. As the shock front expands and cools, the chondrules solidify, while the shock front entrains additional dust. Eventually, the plume expansion stalls and then hydrodynamically collapses, turbulently mixing variably processed dust and size-sorted chondrules. For probable impact parameters and nebular conditions during giant planet growth and migration, the impact-generated mixtures have characteristics that span the range observed in chondritic meteorites, providing an environment for rapid formation of chondritic assemblages after chondrule formation. Our impact vapor and nebular shocks model, named the IVANS model, links chondrule formation to the overall context of planet formation and provides a framework for interpreting the detailed chronological and geochemical record contained in chondritic meteorites.

79 ASTRONOMY AND ASTROPHYSICS↗

Data-Driven Digital Twin for Reliability Assessment of DC/DC Buck Converter

In commercial applications, the operation of DC/DC converters significantly impacts overall system performance and long-term reliability. This study introduces a data-driven digital twin (DT) approach for estimating critical degradation parameters of DC/DC BUCK converter under steady-state condition. Initially, a circuit-level MATLAB/Simulink digital model (DM C ) is refined against a hardware prototype’s switching model dataset using offline particle swarm optimization. The optimized digital model’s steady-state response is then verified with its average model response while varying the duty and load. Subsequently, degradation profiles are imposed on the inductor, capacitor, MOSFET in the DMC. A large dataset is generated from this model, allowing training, validation, and testing of machine learning (ML) models for component health regression tasks. The proposed method employs random forest ML models, achieving impressive regression results with a squared R value as high as 0.99978 and a root mean square error of 4.2× 10 –6 . The method is further validated on a medium power level DC/DC BUCK prototype with varying load conditions, and includes the analysis of MOSFET’s on-resistance under degradation conditions. This data-driven DT method shows promise for identifying parasitic degradation and ohmic loss parameters, enhancing converter reliability assessments in a non-invasive, generalized, and computationally efficient manner.

14 SOLAR ENERGY↗

Analysis of pumped thermal energy storage using particle media integrated with concentrating solar power

Pumped Thermal Energy Storage (PTES) is an electricity storage system that converts electricity into thermal energy which is stored and later transformed back into electricity. Previous work has illustrated that particles have low capital costs and can be operated over a wide range of temperatures. PTES with particle storage achieves higher round-trip efficiency and specific power output than when molten salt thermal energy storage is used. This article explores hybrid systems that combine PTES with Concentrating Solar Power (CSP). Hybrid systems share the majority of components thereby reducing costs compared to two stand-alone devices. In addition, hybrid systems can provide multiple services (such as renewable power generation and electricity storage services). Using particle thermal storage in these hybrid concepts provides freedom in choosing the design conditions, since a wide range of operating temperatures is allowable, therefore making it possible to identify hybrid system designs that have good performance. In this article, two concepts for hybrid PTES-CSP are introduced. Thermodynamic models are developed and these are used to evaluate the performance of two hybrid systems. These models account for turbomachinery efficiency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The “Solar Top-Up” Concept uses CSP to increase the temperature delivered by the charging heat pump. The discharging system uses a topping gas cycle and a bottoming steam cycle to fully exploit the available energy. Using solar heat to increase the maximum temperature from 750 K to 1100 K increases the round-trip efficiency from 41 % to 62 % and the specific work output from 88 kJ/kg to 301 kJ/kg. The second concept is a “Dual-Mode” device which provides both electricity storage and solar electricity generation with the same set of components. The PTES-mode and CSP-mode performance are optimized at different design values but careful parameter selection leads to good performance of both modes: one design produces PTES round-trip efficiency > 60 %, CSP heat engine efficiency > 40 %, and specific work outputs > 150 kJ/kg (for both cycles), when the particle receiver temperature is > 1200 K and maximum heat pump temperature is 1100 K.

14 SOLAR ENERGY↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Neural network representations of multiphase Equations of State

Abstract Equations of State model relations between thermodynamic variables and are ubiquitous in scientific modelling, appearing in modern day applications ranging from Astrophysics to Climate Science. The three desired properties of a general Equation of State model are adherence to the Laws of Thermodynamics, incorporation of phase transitions, and multiscale accuracy. Analytic models that adhere to all three are hard to develop and cumbersome to work with, often resulting in sacrificing one of these elements for the sake of efficiency. In this work, two deep-learning methods are proposed that provably satisfy the first and second conditions on a large-enough region of thermodynamic variable space. The first is based on learning the generating function (thermodynamic potential) while the second is based on structure-preserving, symplectic neural networks, respectively allowing modifications near or on phase transition regions. They can be used either “from scratch” to learn a full Equation of State, or in conjunction with a pre-existing consistent model, functioning as a modification that better adheres to experimental data. We formulate the theory and provide several computational examples to justify both approaches, highlighting their advantages and shortcomings.

Science & Technology - Other Topics↗

Quantum fate of the Choptuik naked singularity

Classical critical collapse provides a dynamical route from smooth initial data to a naked singularity, representing a sharper violation of predictability than ordinary black hole singularities. We argue that this distinction is erased by quantum backreaction. Building on the semiclassical interior analysis, where quantum self-energy of the collapsing matter generates a universal growing mode and a finite mass gap, we study the exterior naked singularity region that determines global visibility in the Einstein-scalar system. We analyze controlled exterior models in both $2+1$ and $3+1$ dimensions. In the former, smooth matching and physical boundary conditions analytically select a vacuum polarization state, whose backreaction cloaks the classically naked region by a quantum trapped branch. In the latter, numerical horizon tracing shows that near a quantum-shifted threshold the exterior develops finite-mass marginally trapped surfaces rather than a zero-mass naked endpoint. These results suggest a global quantum picture in which the Choptuik naked singularity shares the fate of an ordinary black hole singularity: quantum effects push the putative Cauchy horizon behind a quantum-generated horizon, thereby reducing the loss of predictability to the standard black hole evaporation problem.

FOS: Physical sciences↗

Automated Nanocrystal Synthesis: Lessons from 25 Years of Robots, Microfluidics, and Machine Learning

Here, this perspective highlights the evolution of techniques for automating the synthesis of colloidal nanocrystals. Over the past 25 years, microfluidic reactors and robotic workflows have been developed to enhance the reproducibility of nanocrystal synthesis, facilitate rapid screening of reaction conditions, optimize material properties, and perform multistep syntheses of high-quality nanoparticles with complex heterostructures. Modern automated systems are now valued for their ability to generate robust data sets for validating physical models, supporting chemical mechanisms, training machine learning models, and for directing autonomous experimentation. We discuss the early challenges and limitations of these technologies and present key lessons for effectively utilizing automated and ML-guided tools to accelerate nanocrystal discovery for the next 25 years.

Nanocrystals↗

Active Learning of Microgrid Frequency Dynamics Using Neural Ordinary Differential Equations

Accurate frequency modelling of inverter‐based resource (IBR)‐dominated power systems is crucial for ensuring stable, reliable and resilient operations, particularly given their inherent low‐inertia characteristics and fast dynamics that traditional swing equation‐based models inadequately capture. This paper explores neural ordinary differential equations (Neural ODEs) as a computationally efficient, data‐driven framework for modelling power system frequency dynamics, specifically within microgrids integrating high penetrations of distributed energy resources (DERs). The developed neural ODEs framework incorporates a neural network architecture designed to capture input dynamics. By actively perturbing the system with a known signal, the Python‐based neural ODEs framework was trained using measured system states and inputs, without the need for detailed system information. The framework, tested on a model of the Cordova, AK, microgrid, achieved a goodness of fit ranging from 60% to 99% across different state variables and maintained a mean square error in the 10 -6 p.u. range under square and step excitation signals. The proposed approach demonstrated robustness to measurement noise and initial condition variations while maintaining low computational complexity suitable for real‐time power system control applications. Furthermore, transfer learning enabled the neural ODEs model to adapt to the following changes in system topology or generator dispatch, highlighting its effectiveness for dynamic microgrids with frequently evolving configurations and diverse DERs.

Aryal, Tara [South Dakota State Univ., Brookings, ↗

Reduced Order Modeling conditioned on monitored features for response and error bounds estimation in engineered systems

Reduced Order Models (ROMs) form essential tools across engineering domains by virtue of their function as surrogates for computationally intensive digital twinning simulators. Although purely data-driven methods are available for ROM construction, schemes that allow to retain a portion of the physics tend to enhance the interpretability and generalization of ROMs. However, physics-based techniques can adversely scale when dealing with nonlinear systems that feature parametric dependencies. This study introduces a generative physics-based ROM that is suited for nonlinear systems with parametric dependencies and is additionally able to provide numerical error bounds associated with the respective estimates. A main contribution of this work is the conditioning of these parametric ROMs to features that can be derived from monitoring measurements, feasibly in an online fashion. This is contrary to most existing ROM schemes, which remain restricted to the prescription of the physics-based, and usually a priori unknown, system parameters. Our work utilizes conditional Variational Autoencoders to continuously map the required reduction bases to a feature vector extracted from limited output measurements, while additionally allowing for a probabilistic assessment of the ROM-estimated Quantities of Interest. An auxiliary task using a neural network-based parametrization of suitable probability distributions is introduced to re-establish the link with physical model parameters. We verify the proposed scheme on a series of simulated case studies incorporating effects of geometric and material nonlinearity under parametric dependencies related to system properties and input load characteristics.

Conditional VAEs↗

Q3 Report for FY25 Theory and Simulation Performance Target: Development of an integrated modeling framework for fusion reactor design and assessment

This report describes the work and activities carried out towards the completion of each of the following milestones in FY25 Q3: 1. Demonstrate workflow for generating self-consistent CESOL plasma profiles + first wall and divertor loading prediction and generate the CAT plasma and neutron loading needed for further engineering analysis. • Benchmark between two first wall heat flux mapping methods, identify importance of various heat flux sources and physics impact of using fully coupled CESOL vs post-analysis evaluation. 2. Generate medium fidelity parametrized CAD. • Generate parametrized CAD components for the CAT example case via either user-defined modules called within the geometry generation or by defeatured/parametrized CAD, including DCLL blanket matched to divertor boundary and magnets. Define materials, labels, and boundary conditions for passing the mesh to CFD tools. 3. Demonstrate multiphysics magnet analysis. • Demonstrate magnet analysis workflow called from the FREDA workflow, and 4. Demonstrate nuclear analysis. • Add model to OpenFOAM and/or other codes possibly including Diablo to account for tritium diffusion in solids.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-precision monitoring of outgassing species in model extreme ultraviolet photoresists with a cavity ring-down spectrometer

Background Extreme ultraviolet (EUV) photoresists play a pivotal role in advancing nanopatterning technologies by balancing image quality and sensitivity. The outgassing behavior of photoresist thin films under EUV and deep ultraviolet (DUV) exposure reveals chemical details relevant to their performance. Aim Here, we focus on utilizing an analytical technique not previously used in photolithography, the tabletop cavity ring-down spectrometer, to investigate outgassing dynamics in EUV photoresists, enabling precise chemical identification and deeper insights into resist processing. Approach The spectrometer’s enhanced laser path length (∼ 20 km) and broadband absorption capabilities in the C–H overtone region allow for sensitive and temporally resolved detection of mixtures of outgassed species. Using a model resist comprising a polymer matrix with a photoacid generator and quencher, we analyzed the influence of time delays between exposure and post-exposure bake (PEB) as well as storage under varying environmental conditions. Results Suppression of isobutylene outgassing and thickness loss was observed with extended delays between exposure and PEB, potentially linked to water absorption and acid deactivation. The technique proved highly effective in distinguishing subtle chemical differences between processing stages. Conclusions Delay times and their environmental conditions, particularly humidity, reduce outgassing and thickness loss of photoresists during PEB, suggesting decreased acid-driven deprotection. This can potentially impact sensitivity, defectivity, and roughness of resist patterns, necessitating precise monitoring and control.

Extreme ultraviolet photoresists↗

High precision monitoring of outgassing species in model EUV photoresists with a cavity ring-down spectrometer

Extreme ultraviolet (EUV) photoresists play a pivotal role in advancing nanopatterning technologies by balancing image quality and sensitivity. The outgassing behavior of photoresist thin films under EUV and deep ultraviolet (DUV) exposure reveals chemical details relevant to their performance. This study focuses on utilizing an analytical technique not previously used in photolithography, the tabletop cavity ring-down spectrometer, to investigate outgassing dynamics in EUV photoresists, enabling precise chemical identification and deeper insights into resist processing. The spectrometer’s enhanced laser path length (~20 km) and broadband absorption capabilities in the CH overtone region allow for sensitive and temporally resolved detection of outgassed species. Using a model resist comprising a polymer matrix with a photoacid generator and quencher, we analyzed the influence of time delays between exposure and Post-Exposure Bake (PEB) as well as storage under varying environmental conditions. Suppression of isobutylene outgassing and thickness loss was observed with extended delays between exposure and PEB, potentially linked to water absorption and acid deactivation. The technique proved highly effective in distinguishing subtle chemical differences between processing stages. Delay times and their environmental conditions, particularly humidity, reduce outgassing and thickness loss of photoresists during PEB, suggesting decreased acid-driven deprotection. This can potentially impact sensitivity, defectivity, and roughness of resist patterns, necessitating precise monitoring and control.

Lüttgenau, Bernhard↗

Lidar-Based Evaluation of HRRR Performance in California’s Diablo Range

The performance of the NOAA High-Resolution Rapid Refresh (HRRR) model for capturing low-level winds near a wind energy production site during summer 2019 is evaluated. This study catalogs the ability of HRRR to predict boundary layer dynamics relevant to wind energy interests over complex terrain, which has presented challenges for weather and energy forecasting. Performance is evaluated by comparing HRRR output to wind-profiling Doppler lidars at Lawrence Livermore National Laboratory Site 300. HRRR captured the diurnal profile of horizontal winds in the observed 150-m layer, despite strong underpredictions (∼4 m s −1 ) during evening and nighttime hours. These underpredictions may be a result of local speedup flows observed by the lidars, which were unresolved in HRRR due to their small spatial extent. HRRR bias magnitude relative to observations was found to be minimal during days with synoptic-scale troughs and strong 850-hPa geopotential gradients, while bias magnitude was maximal during days with synoptic ridging and weak 850-hPa geopotential gradients. To translate wind speed predictions to energy forecasting, generic turbine models were used to estimate power generation for turbines characteristic of the nearby Altamont Pass Wind Resource Area. Results show that HRRR-based energy estimates predicted daytime power generation adequately relative to lidar-based estimates with an 18-h lead time (bias magnitude < 0.4 MW from 0900 to 1400 LT) but overpredicted power during the rest of the diurnal cycle (bias > 1 MW). These results demonstrate conditions under which HRRR performs well for wind energy applications in complex terrain, while highlighting biases that require further investigation to support usage of a high-resolution model for wind energy forecasts.

Boundary layer↗

Designing Operationally Flexible Diafiltration Membrane Systems for Critical Mineral Separations

This talk presents the design of operationally flexible diafiltration membrane systems for Li/Co recovery, and applies robust optimization methodologies using these flexible systems to generate optimal designs immune to membrane manufacturing variability and uncertain process inlet conditions. The results highlight the use of robust optimization to find design strategies and insights that may reduce technical risks arising from model uncertainties.

Yao, Jason↗

Treatment and Mineral Recovery from Combustion Residual Leachate and Produced Water

This talk presents the design of operationally flexible diafiltration membrane systems for Li/Co recovery, and applies robust optimization methodologies using these flexible systems to generate optimal designs immune to membrane manufacturing variability and uncertain process inlet conditions. The results highlight the use of robust optimization to find design strategies and insights that may reduce technical risks arising from model uncertainties.

Able, Chad↗

Analyzing the Impact of Future Weather Data on Energy Consumption in Weatherization Assistant

This study supports the mission of the U.S. Department of Energy’s Weatherization Assistance Program (WAP), which aims to increase the energy efficiency of dwellings and reduce their total residential expenditures. Specifically, we examine how projected future climate conditions may affect residential building energy performance by integrating future weather data into the National Energy Audit Tool (NEAT). Since WAP evaluates the cost-effectiveness of retrofit measures over lifespans of up to 30 years, accounting for evolving climate conditions is increasingly important. To reflect future household energy demands, this study replaces historically based Typical Meteorological Year (TMY3) weather inputs with Future Typical Meteorological Year (fTMY) datasets derived from global climate model (GCM) projections. A simulation-based framework was established to enable NEAT analysis under future weather conditions. This workflow involves converting EPW-format weather files into JSON inputs compatible with NEAT and generating degree-hour metrics needed for load calculations. The fTMY dataset used in this study was developed by Oak Ridge National Laboratory through downscaling of six GCMs under different emission scenarios and covers the period from 2020 to 2100. In contrast, the TMY3 dataset is based on historical weather data from 1961 to 1990. Simulations were conducted for benchmark single-family prototype buildings across ASHRAE climate zones 1–7, which cover all regions of the U.S. except the subarctic Zone 8 in northern Alaska, evaluating both heating and cooling loads under TMY3 and fTMY conditions. Four foundation types were tested, while heating systems were standardized, as NEAT does not differentiate thermal energy load by HVAC system type in its load calculations. Results show that fTMY weather input consistently yield lower heating loads and higher cooling loads across most locations, aligning with expected climate warming trends. Notably, colder regions such as zones 6A, 6B, and 7 experience marked reductions in heating load, while warmer and transitional zones, such as 2A (Lufkin, TX) and 3C (San Francisco, CA), have substantial increases in cooling loads. Although this study does not directly assess the performance of retrofit measures under future climate conditions, it provides a critical foundation for doing so. By quantifying shifts in baseline (i.e., pre-retrofit case) energy loads between historical and future weather files, the study highlights the importance of integrating climate-responsive data into audit tools. These findings will inform future efforts to evaluate the long-term effectiveness and cost-effectiveness of weatherization measures under changing climate conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Resolution WRF-Based Downscaling of Earth System Model Projections for Energy Applications across CONUS

Evaluating energy resources under future scenarios requires meteorological information that adequately resolves regional-scale variability and is suitable for regional energy system studies. Although Earth system model (ESM) outputs provide essential large-scale context, their coarse resolution and inherent biases limit direct use in energy system applications. This work presents a high-resolution dynamical downscaling framework using the Weather Research and Forecasting (WRF) model to generate energy-relevant regional fields for future scenarios over the contiguous United States (CONUS). The framework first identifies an optimal WRF configuration through sensitivity experiments, then evaluates raw and bias-corrected ESM initial and boundary conditions, with soil moisture and soil temperature bias correction implemented as an integral component of the bias-corrected ESM atmospheric forcing prior to WRF dynamical downscaling to improve land-atmosphere interactions. Simulations performed at 4-km resolution show that uncorrected ESM forcing leads to systematically dry and cold soil states, which propagate into elevated near-surface air temperature and solar irradiance biases, particularly during summer for the period 2000-2014. Incorporating bias-corrected atmospheric forcing together with soil state bias correction substantially reduces these errors and improves the representation of surface energy processes in WRF simulations. The results highlight the importance of bias-aware initialization strategies in high-resolution dynamical downscaling for future energy system analysis and planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A comparison of surrogate constitutive models for viscoplastic creep simulation of HT-9 steel

Mechanistic microstructure-informed constitutive models for the mechanical response of polycrystals are a cornerstone of computational materials science. However, as these models become increasingly more complex – often involving coupled differential equations describing the effect of specific deformation modes – their associated computational costs can become prohibitive, particularly in optimization or uncertainty quantification tasks that require numerous model evaluations. To address this challenge, surrogate constitutive models that balance accuracy and computational efficiency are highly desirable. Data-driven surrogate models, that learn the constitutive relation directly from data, have emerged as a promising solution. In this work, we develop two local surrogate models for the viscoplastic response of a steel: a piecewise response surface method and a mixture of experts model. These surrogates are designed to adapt to complex material behavior, which may vary with material parameters or operating conditions. The surrogate constitutive models are applied to creep simulations of HT-9 steel, an alloy of considerable interest to the nuclear energy sector due to its high tolerance to radiation damage, using training data generated from viscoplastic self-consistent (VPSC) simulations. In conclusion, we define a set of test metrics to numerically assess the accuracy of our surrogate models for predicting viscoplastic material behavior, and show that the mixture of experts model outperforms the piecewise response surface method in terms of accuracy.

36 MATERIALS SCIENCE↗