Search NASA⌕ Search

SEARCH · Search NASA

Results for “cooling center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Expanding a Supercomputer Facility Using Modular Data Center Technology

With the expansion of high-end computing resources needed to support NASA's increasing demands for physics-based simulations, the facility housing Pleiades-the agency's largest supercomputer-recently reached its power and cooling capacity. In response, the NASA Advanced Supercomputing Division at Ames Research Center undertook a prototype project that resulted in a new facility based on modular data center technology. The facility, a ~1000 square-foot module on a concrete pad with room for 16-18 compute racks, was completed in fall 2016 and an SGI computer system, named Electra, was deployed there in early 2017. Cooling is performed via an evaporative system built into the module, and preliminary experience shows a Power Usage Effectiveness (PUE) of ~1.03. Electra achieved over a petaflop on the LINPACK benchmark, sufficient to rank number 96 on the November 2016 TOP500 list. The system consists of 1,152 InfiniBand-connected Intel Xeon Broadwell-based nodes. Its users access their files on a facility wide file system shared by all compute assets via Mellanox MetroX InfiniBand extenders, which connect the Electra fabric to Lustre routers InfiniBand fabric over fiber-optic links about 300 meters long. The prototype has exceeded expectations and is serving as a blueprint for future expansions.*†

Facility↗

A windswept cometary tail on the Galactic center supergiant IRS 7

High-resolution VLA observations provide evidence of optically thick radio emission from IRS 7, a cool red supergiant star, located at a projected distance of roughly 1 1t-yr from the Galactic center. IRS 7 shows a remarkable tail of ionized gas pointing directly away from the compact nonthermal radio source at the Galactic center, Sgr A(asterisk). Given previous evidence for a strong source of UV emission and for a strong circumnuclear wind emanating from the Galactic center, the free-free emission from IRS 7 and its associated tail are interpreted in terms of the ionization and removal of the circumstellar envelope of the red supergiant either by the ram pressure of the nuclear wind or by the pressure of radiation arising from the immediate vicinity of Sgr A(asterisk). The wind mechanism is preferred because: (1) the force it can potentially exert is much greater; and (2) Sgr A(asterisk) is clearly not a known source of luminous energy in the near-IR, whereas it remains a plausible source of a hot, high-velocity wind. Also considered is the potential effect of a nuclear wind upon the atmospheres of red giants in the inner parsec.

Yusef-Zadeh, F.↗

Passively Cooled Superconductors Final Report

A highly reflective spray-on coating and tile material has been under development at Kennedy Space Center (KSC) that scatters away most of the Sun’s energy, thereby allowing coated objects to remain cool in space. The best performing tile material has achieved 1% solar absorptivity while the best performing spray-on coating has achieved around 4%. Both versions passively maintain cryogenic temperatures below 120 K at 1 astronomical unit (AU) from the Sun, but the tile material consistently sustains temperatures below 90 K, which is low enough to preserve oxygen and methane in a liquid state. Besides keeping propellants cold, this “solar white” material has the potential to passively maintain high-temperature superconductors (HTS) in a superconducting state without the support of liquid nitrogen cooling. If superconductors can be operated without the added infrastructure of liquid nitrogen cooling, it may enable them to be used in space for applications like magnetic radiation shielding and efficient energy management. Long duration exposure to both galactic cosmic radiation and coronal mass ejections can pose health risks for the astronauts and increase the potential for damage to electronics. This makes shielding essential to accomplish long duration missions, particularly when astronauts are onboard. The objective of this project was to determine the extent we could keep a high-temperature superconducting (HTS) material passively chilled to maintain its superconducting state. Both the tile and spray-on versions of solar white were investigated. We focused on finding a version that could support passive cooling at 1 AU from the Sun and determined the closest operating distances for samples that were unable to perform at 1 AU. Early in the project, we selected bismuth strontium calcium copper oxide (BSCCO) as the HTS to test based on its reputable usage in superconducting wires. The version we selected was Bi-2223, which has a critical temperature of about 108 K. Sample bars with contacts for a four-point probe were obtained from Quantum Levitation: https://quantumlevitation.com/product/superconductor-bar-for-4-point-tc-experiment/.

superconductors↗

X-ray bursts from solar flares behind the limb

Data from the OSO-7 X-ray experiment were used in a search for behind-the-limb solar X-ray bursts. Seventeen active centers were found as likely seats of such bursts. The spectra of 37 over-the-limb X-ray bursts were analyzed. The distributions of maximum temperature, maximum emission measure, and characteristic cooling time do not differ in a statistically significant way from the distributions for center events. The observations support the view that the dominant cooling mechanism is conduction, for the cooling times derived from the temperature histories are too small to be explained by radiative cooling. The fraction of over-the-limb bursts which have an nonthermal component is 2/3, exactly the same as found for the 122 X-ray bursts studied in Datlowe et al. (1974b). Thick-target models of X-ray emission would suggest that hard X-ray sources would be rapidly occulted with increasing longitude of the burst location, yet just the contrary was observed.

Roy, J.-R.↗

High Performance Computing to Quantify the Evolution of Microscopic Concentration Gradients During Flash Processing

During the Flash process, the cross section of a plain-carbon or a low-alloy steel is austenitized through rapid heating and transformed on rapid cooling to a predominantly martensite + bainite structure with small amounts of retained austenite. Unlike conventional heat treating, homogeneity is intentionally avoided during Flash processing of steels. The Flash process assembly consists of a pair of rolls that transfer the steel sheets through the heating and cooling stage of the thermal cycle. The initial microstructure of the steel consists of ferrite (body-centered cubic iron) + carbide ((Fe,X)mCn) mixture. The heating rate through the peak temperature is a function of temperature and reaches a peak of about 300-400°C/s and the cooling rate has a maximum value of 3,000-4,000°C/s. The on-heating phase transformations include carbide dissolution, austenite (face-centered cubic iron) nucleation and growth, and diffusion of carbon and other substitutional elements in the steel. The on-cooling phase transformations include formation of martensite (body-centered tetragonal phase containing supersaturated solute) and bainite (ferrite plates with or without fine carbides). In this project, the focus is on Fe-C-Cr steels that are currently Flash processed for armor applications. The modeling effort proposed here will help optimize the Flash thermal cycle for these low alloy steels to achieve the target performance, which is an ongoing effort at SFP Works. A significant feature of Flash processed Fe-C-Cr steels is the presence of scatter in the through-thickness in the sheet. The variability in hardness results from a variability in the bainite + martensite microstructure that is sensitive to the local chemical concentration of C and Cr. Such a chemical inhomogeneity is intentionally obtained in the Flash process. Although such a microstructural gradient is presumably responsible for the exceptional properties of the Flash processed steel, it is very important to quantify the gradients as a function of Flash variabilities in processing parameters and the input microstructure. Understanding the mechanistic pathway that leads to microstructural gradients could be ground-breaking and instrumental for achieving better process control and optimized microstructural state to meet application-specific strength-ductility requirements. Since the final microstructure depends on setting up precise solute concentration gradients through a rapid heating process, and transforming these regions into various phases, it is important to understand how small changes in steel chemistry, input microstructure (carbide size and distribution), and process variables (Flash thermal cycle) will impact the solute concentration gradients.

97 MATHEMATICS AND COMPUTING↗

Determining the effects of U/Pu ratio on subsolidus phase transitions in U-Pu-Zr metallic fuel alloys

Here, ternary alloys consisting primarily of uranium, plutonium, and zirconium (U-Pu-Zr) are among the leading candidate fuel systems considered for fast spectrum nuclear reactors. Despite historical operation data from the testing of U-Pu-Zr rods in the Experimental Breeder Reactor-II, considerable uncertainty about the evolution of phases and microstructure across the ternary composition space exists. Due to sluggish kinetics and other difficulties in handling metal actinide specimens, quantitative measurements of phase-transitions in U-Pu-Zr alloys remain sparse in scientific literature, with most investigators reporting either phase-transition temperatures or phase identification data, but not both from the same specimens. The purpose of this paper is to critically compare experimental and calculated phase transition data and correlate with the microstructure and phase characterization data of as-cast and annealed U-Pu-Zr alloys. Phase transition peaks were measured using differential scanning calorimetry in the subsolidus regions (723-948 K) of three ternary U-Pu-Zr alloys with the same zirconium concentration but various U/Pu ratios. Overlapping peaks were deconvoluted using a Frazier-Suzuki peak fitting algorithm, and the critical peak temperatures and enthalpies were calculated. In general, increasing concentrations of Pu were associated with enhanced thermal stability of the body-centered cubic γ phase upon both heating and cooling. Experimental phase transition temperatures in this study tended to agree well with the predictions of the established ternary phase diagrams and other reported phase transition temperatures in literature. Additionally, the TAF-ID thermodynamic database was used to calculate a U-Pu-40 at.% Zr pseudobinary diagram as well as ternary diagrams from 773 to 973 K. The equilibrium phase transition temperatures tended to be considerably lower than measured peak temperatures upon both heating and cooling. Recommendations for improving the quality of data in future U-Pu-Zr characterization studies are also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaporation and propagation of liquid drop streams at vacuum pressures: Experiments and modeling

Evaporation of streams of liquid droplets in environments at vacuum pressures below the vapor pressure has not been widely studied. Here, experiments and simulations are reported that quantify the change in droplet diameter when a steady stream of ≈100 μm diameter drops is injected into a chamber initially evacuated to <10 –8 bar. In experiments, droplets fall through the center of a 0.8 m long liquid nitrogen cooled shroud, simulating infinity radiation and vapor mass flux boundary conditions. Furthermore, experimentally measured changes in drop diameters vary from ≈0 to 6 μm when the initial vapor pressure is increased from 10 –6 to 10 –3 bar by heating the liquid. Measured diameter changes are predicted by a model based on the Hertz-Knudsen equation. One uncertainty in the calculation is the “sticking coefficient” β. Assuming a constant β for all conditions studied here, predicted diameter changes best match measurements with β≈0.3. This value falls within the range of β reported in the literature for organic liquids. Finally, at the higher vapor pressure conditions considered here, the drop stream disperses transverse to the main flow direction. This spread is attributed to forces imparted by an absolute pressure gradient produced by the evaporating stream.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

AGR-3/4 TRISO Fuel Compact Ceramography

The combined third and fourth irradiation in the Advanced Gas Reactor (AGR) program (AGR-3/4) contained tristructural isotropic (TRISO)-coated particle fuel and designed-to-fail (DTF) fuel particles. The DTF particles were only coated with highly anisotropic pyrocarbon (PyC) so they would purposely fail during the AGR-3/4 irradiation and provide a source of fission products for measurement. To observe the post-irradiation morphology of these DTF particles and the TRISO-coated particles, three AGR-3/4 compacts were mounted in epoxy, sectioned above their centerlines, and ground/polished. Three rounds of grinding/polishing and optical microscopy were performed so that the particles could be observed at multiple planes. Each compact contained approximately 1,872 TRISO particles and exactly 20 DTF particles. The three AGR-3/4 compacts examined covered a wide temperature range and featured both the hottest average irradiation temperature (1375°C) and the coldest/lowest burnup (872°C and 5.5% fissions per initial metal atom) of any compacts to undergo post-irradiation examination (PIE) in the AGR program to date. A total of 29 DTF particles were located and observed via microscopy across the three compacts. All the DTF particles observed via microscopy had completely failed PyC coatings. Some different DTF kernel and PyC morphologies were observed that have been attributed to the differences in irradiation temperature and/or burnup. At low and medium irradiation temperatures (roughly 850 to 1050°C), it appears irradiation-induced dimensional changes in the DTF PyC caused it to fracture and fold in on itself, and the kernel deformed to accommodate this PyC deformation. The extent of DTF kernel deformation to accommodate DTF PyC buckling tended to be greater for the medium-temperature fuel compared to the cold fuel. In the high-irradiation-temperature compact (1375°C), the DTF PyC layer appears to have completely reacted chemically with the kernel material. The only material surrounding the DTF particles in this hot compact resembles the compact matrix material. Observations of the TRISO-coated driver fuel particles and fuel compact graphitic matrix were also made. The TRISO particle kernels in the medium-temperature compact (1047°C), and many in the high-temperature compact (1375°C), showed morphologies consistent with what was seen in AGR-1 and AGR-2. In other TRISO particles from the high-temperature compact, a spatial gradient in the kernel appearance was evident. Here the cool side of the kernel (away from the center of the compact) had a much darker appearance (like that of the buffer and pyrocarbon). This is the first observation of this kind of kernel spatial gradient in AGR fuel. It is believed that the high irradiation temperature of that compact (an average of 1375°C) activates or accelerates an unidentified chemical reaction, and the temperature gradient within the fuel causes a sharp spatial gradient. The low-temperature/low-burnup compact also showed unique kernel morphologies where the TRISO-coated particles had clearly distinguishable oxide and carbide phases at the center of the kernel, an oxide rind surrounding this, and remnants of a carbide skin surrounding the oxide rind. These are features observed in the as-fabricated fuel that are no longer present in higher burnup fuel. Occasional gaps between the outer pyrolytic carbon (OPyC) and graphitic matrix material were observed in all compacts. Gaps were most often found in the small, matrix-filled spaces between adjacent particles. Finally, buffer morphologies in AGR-3/4 TRISO particles were like those observed in AGR-1 and AGR-2, and the buffer fracture frequencies in AGR-3/4 and AGR-2 TRISO particles were plotted versus fast neutron fluence and irradiation temperature. In AGR-3/4 the buffer fracture rate was highest (23%) for an irradiation temperature of 1047°C and a fast fluence of 5.18E25 n/m 2 . Increasing the irradiation temperature to 1375°C reduced the buffer fracture rate to 14%. Reducing the irradiation temperature to 872°C and the fast fluence by a factor of 3 reduced the buffer fracture rate to 7%. The temperature and fluence dependencies observed for AGR-3/4 buffer fracture were consistent with those observed in AGR-2. Lower fluences and/or higher temperatures significantly reduced the buffer fracture frequencies. Lower buffer fracture frequencies were also observed at lower temperatures as long as the fluence was also significantly reduced. This is believed to be due to lower fluence resulting in less irradiation-induced dimensional change (shrinkage) of the buffer, and a higher temperature promoting enhanced creep relaxation of stresses within the buffer, leading to less buffer fracture.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dissipative Dark Substructure: The Consequences of Atomic Dark Matter on Milky Way Analog Subhalos

Using cosmological hydrodynamical zoom-in simulations, we explore the properties of subhalos in Milky Way analogs that contain a subcomponent of atomic dark matter (ADM). ADM differs from cold dark matter (CDM) due to the presence of self-interactions that lead to energy dissipation, analogous to standard model baryons. This model can arise in dark sectors that are natural and theoretically motivated extensions to the standard model. The simulations used in this work were carried out using GIZMO and utilize the FIRE-2 galaxy formation physics in the standard model baryonic sector. For the parameter points we consider, the ADM gas cools efficiently, allowing it to collapse to the center of subhalos. This increases a subhalo's central density and affects its orbit, with more subhalos surviving small pericentric passages. The subset of subhalos that host satellite galaxies have cuspier density profiles and smaller stellar half-mass radii relative to CDM. The entire population of dwarf galaxies produced in the ADM simulations is more compact than those seen in CDM simulations, unable to reproduce the entire diversity of observed dwarf galaxy structures. Additionally, we also identify a population of highly compact subhalos that consist nearly entirely of ADM and form in the central region of the host, where they can leave distinctive imprints in the baryonic disk. This work presents the first detailed exploration of subhalo properties in a strongly dissipative dark matter scenario, providing intuition for how other regions of ADM parameter space, as well as other dark sector models, would impact galactic-scale observables.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design, fabrication, testing and delivery of a solar collector

A two phase program encompassing the redesign and fabrication of a solar collector which is low in cost and aesthetically appealing is described. Phase one work reviewed the current collector design and developed a low-cost design based on specific design/performance/cost requirements. Throughout this phase selected collector component materials were evaluated by testing and by considering cost, installation, maintainability and durability. The resultant collector design was composed of an absorber plate, insulation, frame, cover, desiccant and sealant. In Phase two, three collector prototypes were fabricated and evaluated for both nonthermal and thermal characteristics. Tests included static load tests of covers, burst pressure tests of absorber plates, and tests for optical characteristics of selective absorber plate coatings. The three prototype collectors were shipped to Marshall Space Flight Center for use in their solar heating and cooling test facility.

Sims, W. H.↗

Experimental facilities for electric propulsion testing

Experimental facilities for electric propulsion testing at the University of Tennessee Space Institute, jointly operated by the Center for Advanced Space Propulsion, include a cryogenically cooled, computer-controlled, 9 ft diameter by 20 ft long vacuum chamber, capable of maintaining a baseline pressure of 10(exp -7) Torr, a 30 cm diameter ion thruster, and laser diagnostic and electrical diagnostic instrumentation. These facilities are described here in some detail, with emphasis on the measurement of ion thruster parameters such as neutral and ion densities, temperature, and velocity in the exhaust, as well as plasma potential and electron temperature.

Ruyten, Wilhelmus M.↗

No Compton Reflection In a Chandra/RXTE Observation of Mkn 509: Implications for the Fe-K Line Emission From Accreting X-Ray Sources

We report the results of simultaneous Chandra and RXTE observations of the Seyfert 1 galaxy Mkn 509. We deconvolve the broad and narrow Fe-K emission-line components for which we measure rest-frame equivalent widths of 119+/-18 eV and 57+/-13 eV respectively. The broad line has a FWHM of 57,600((sup 14,400)(sub -21,000)) km/s and the narrow line is unresolved, with an upper limit on the FWHM of 4,940 km/s. Both components must originate in cool matter since we measure rest-frame center energies of 6.36((sup +0.13)(sub -0.12)) keV and 6.42+/-0.01 keV for the broad and narrow line respectively. This rules out He-like and H-like Fe for the origin of both the broad and narrow lines. If, as is widely accepted, the broad Fe-K line originates in Thomson-thick matter (such as an accretion disk), then one expects to observe spectral curvature above approximately 10 keV, (commensurate with the observed broad line), characteristic of the Compton-reflection continuum. However our data sets very stringent limits on deviations of the observed continuum from a power law. Light travel-time delays cannot be invoked to explain anomalies in the relative strengths of the broad Ferry line and Compton-reflection continuum since they are supposed to originate in the same physical location. We are forced to conclude that both the broad and narrow Fe-K lines had to originate in Thomson-thin matter during our observation. This result, for a single observation of just one source, means that our understanding of Fe K line emission and Compton reflection from accreting X-ray sources in general needs to be re-examined. For example, if an irradiated accretion disk existed in Mkn 509 at the time of the observations, the lack of spectral curvature above approximately 10 keV suggests two possibilities. Either the disk was Thomson-thick and highly ionized, having negligible Fe-K line emission and photoelectric absorption or the disk was Thomson-thin producing some or all of the broad Fe-K line emission. In the former case, the broad Fe-K line had to have produced in a Thomson-thin region elsewhere. In both cases the predicted spectral curvature above approximately 10 keV is negligible. An additional implication of our results is that any putative obscuring torus in the system, required by unification models of active galaxies, must also be Thomson-thin. The same applies to the optical broad line region (BLR) if it has a substantial covering factor.

Yaqoob, Tahir↗

Do-It-Yourself Additives Recharge Auto Air Conditioning

In planning for a return mission to the Moon, NASA aimed to improve the thermal control systems that keep astronauts comfortable and cool while inside a spacecraft. Goddard Space Flight Center awarded a Small Business Innovation Research (SBIR) contract to Mainstream Engineering Corporation, of Rockledge, Florida, to develop a chemical/mechanical heat pump. IDQ Inc., of Garland, Texas, exclusively licensed the technology and incorporates it into its line of Arctic Freeze products for automotive air conditioning applications. While working on the design, Mainstream Engineering came up with a unique liquid additive called QwikBoost to enhance the performance of the advanced heat pump design.

Source record↗

James Webb Space Telescope Integrated Science Instrument Module Calibration and Verification of High-Accuracy Instrumentation to Measure Heat Flow in Cryogenic Testing

The James Webb Space Telescope (JWST) is an upcoming flagship observatory mission scheduled to be launched in 2018, Three of the four science instruments are passively cooled to their operational temperature range of 36K to 40K, and the fourth instrument is actively cooled to its operational temperature of approximately 6K. The requirement for multiple thermal zones results in the instruments being thermally connected to five external radiators via individual high purity aluminum heat straps. Thermal-vacuum and thermal balance testing of the flight instruments at the Integrated Science Instrument Module (ISIM) element level will take place within a newly constructed shroud cooled by gaseous helium inside Goddard Space Flight Center's (GSFC) Space Environment Simulator (SES). The flight external radiators are not available during ISIM-Ievel thermal vacuum/thermal testing, so they will be replaced in test with stable and adjustable thermal boundaries with identical physical interfaces to the flight radiators. Those boundaries are provided on specially designed test hardware which measures the heat flow within each of the five heat straps to an accuracy of less than 2 m W, which is less than 5% of the minimum predicted heat flow values. This is essential to ISIM thermal model correlation, since thermal models are more accurately correlated when temperature data is supplemented by accurate knowledge of heat flows. Devices that measure heat flow in this manner have historically been referred to as "Q-meters". Perhaps the most important feature of the design of the Q-meters is that it does not depend on the absolute accuracy of its temperature sensors, but rather on a difference in heater power, for which a table is empirically developed during a calibration campaign in a small chamber at GSFC. This paper discusses the Q-meter calibration procedure including calibration chamber modifications and accommodations, the handling of differing conditions between calibration and usage, the calibration process itself, and the results of the tests used to determine if the calibration is successful.

Comber, Brian↗

James Webb Space Telescope Integrated Science Instrument Module Calibration and Verification of High-Accuracy Instrumentation to Measure Heat Flow in Cryogenic Testing

The James Webb Space Telescope (JWST) is an upcoming flagship observatory mission scheduled to be launched in 2018. Three of the four science instruments are passively cooled to their operational temperature range of 36K to 40K, and the fourth instrument is actively cooled to its operational temperature of approximately 6K. The requirement for multiple thermal zoned results in the instruments being thermally connected to five external radiators via individual high purity aluminum heat straps. Thermal-vacuum and thermal balance testing of the flight instruments at the Integrated Science Instrument Module (ISIM) element level will take place within a newly constructed shroud cooled by gaseous helium inside Goddard Space Flight Center's (GSFC) Space environment Simulator (SES). The flight external radiators are not available during ISIM-level thermal vacuum/thermal testing, so they will be replaced in test with stable and adjustable thermal boundaries with identical physical interfaces to the flight radiators. Those boundaries are provided by specially designed test hardware which also measures the heat flow within each of the five heat straps to an accuracy of less than 2 mW, which is less than 5% of the minimum predicted heat flow values. Measurement of the heat loads to this accuracy is essential to ISIM thermal model correlation, since thermal models are more accurately correlated when temperature data is supplemented by accurate knowledge of heat flows. It also provides direct verification by test of several high-level thermal requirements. Devices that measure heat flow in this manner have historically been referred to a "Q-meters". Perhaps the most important feature of the design of the JWST Q-meters is that it does not depend on the absolute accuracy of its temperature sensors, but rather on knowledge of precise heater power required to maintain a constant temperature difference between sensors on two stages, for which a table is empirically developed during a calibration campaign in a small chamber at GSFC. This paper provides a brief review of Q-meter design, and discusses the Q-meter calibration procedure including calibration chamber modifications and accommodations, handling of differing conditions between calibration and usage, the calibration process itself, and the results of the tests used to determine if the calibration is successful.

Comber, Brian↗

Copper-Water and Hybrid Aluminum-Ammonia Heat Pipes for Spacecraft Thermal Control Applications

Copper-water heat pipes are commonly used for thermal management of electronics systems on earth and aircraft, but have not been used in spacecraft thermal control applications to date, due to the satellite industry's requirement that any device or system be successfully tested in a microgravity environment prior to adoption. Recently, Advanced Cooling Technologies Inc., (ACT), NASA Marshall Space Flight Center, and the International Space Station office at NASA's Johnson Space Center demonstrated flight heritage in Low-Earth Orbit. The testing was conducted aboard the International Space Station (ISS) under the Advanced Passive Thermal eXperiment (APTx) project. The heat pipes were embedded in a high conductivity (HiK"TM") aluminum base plate and subject to a variety of thermal tests over a temperature range of -10 to 38 ºC for a ten-day period. Results showed excellent agreement with both predictions and ground tests. In addition, novel hybrid wick aluminum-ammonia heat pipes are developed to handle heat flux requirements for spacecraft thermal control applications. The 5-10 W/cm2 heat density limitation of aluminum-ammonia grooved heat pipes has been a fundamental limitation in the current design for space applications. The recently demonstrated 50 W/cm2 capability of the hybrid high heat flux heat pipes provides a realistic means of managing the high heat density anticipated for the next generation space designs.

Ababneh, Mohammed T.↗

Copper-Water and Hybrid Aluminum-Ammonia Heat Pipes for Spacecraft Thermal Control Applications

Copper-water heat pipes are commonly used for thermal management of electronics systems on earth and aircraft, but have not been used in spacecraft thermal control applications to date, due to the satellite industry's requirement that any device or system be successfully tested in a microgravity environment prior to adoption. Recently, Advanced Cooling Technologies Inc., (ACT), NASA Marshall Space Flight Center, and the International Space Station office at NASA's Johnson Space Center demonstrated flight heritage in Low-Earth Orbit. The testing was conducted aboard the International Space Station (ISS) under the Advanced Passive Thermal eXperiment (APTx) project. The heat pipes were embedded in a high conductivity (HiK "TM") aluminum base plate and subject to a variety of thermal tests over a temperature range of -10 to 38 C for a ten-day period. Results showed excellent agreement with both predictions and ground tests. In addition, novel hybrid wick aluminum-ammonia heat pipes are developed to handle heat flux requirements for spacecraft thermal control applications. The 5-10 W/cm2 heat density limitation of aluminum-ammonia grooved heat pipes has been a fundamental limitation in the current design for space applications. The recently demonstrated 50W/cm2 capability of the hybrid high heat flux heat pipes provides a realistic means of managing the high heat density anticipated for the next generation space designs.

Ababneh, Mohammed T.↗

Low-temperature transonic cooling flows in galaxy clusters

Calculations are presented which demonstrate that cooling flow models with large sonic radii may be consistent with observed cluster gas properties. It is found that plausible cluster parameters and cooling flow mass accretion rates can produce sonic radii of 10-20 kpc for sonic point temperatures of 1-3 x 10 to the 6th K. The numerical calculations match these cooling flows to hydrostatic atmosphere solutions for the cluster gas beyond the cooling flow region. The cooling flows produce no appreciable 'holes' in the surface brightness toward the cluster center, and the model can be made to match the observed X-ray surface brightness of three clusters in which cooling flows had been believed to be absent. It is suggested that clusters with low velocity dispersion may be the natural location for such 'cool' cooling flows, and fits of these models to the X-ray surface brightness profiles for three clusters are presented.

Sulkanen, Martin E.↗