Search NASA⌕ Search

SEARCH · Search NASA

Results for “cost study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Multi-facility analysis using metered power data to quantify MRI energy use and utility bill costs across scanner operating modes

This study quantifies the energy consumption of magnetic resonance imaging (MRI) scanners across discrete operating modes during routine clinical workflows, based solely on electrical power measurements. Although previous studies have investigated MRI energy consumption within single hospitals or specific clinical settings, this research provides a broader and more systematic analysis. Researchers analyzed electrical power data and applied a previously developed semi-automatic method for identifying MRI operating modes using load duration curves for 20 MRI scanners across four different U.S. healthcare facilities, encompassing outpatient, inpatient, and mixed-use clinical settings. A key innovation is the inclusion of localized hourly utility rates to estimate costs, a parameter absent in prior literature. Key findings indicate significant variability in energy and cost profiles between weekdays and weekends. Scanner characteristics, including magnet strength, manufacturer, vintage, location, and clinical setting, influenced average daily energy consumption and power thresholds for operating modes. Notably, the clinical setting of a scanner predominantly determines its energy use. For example, the scanners in outpatient facilities consumed more energy. The breakdown of energy usage and costs by operating modes showed scanners spend between 61% and 93% of their time in nonproductive modes, with one outlier spending 34%. Average daily energy use for the scanners in the study ranged from 160 to 1069 kWh, with energy costs ranging from $\$$9 to $\$$149. This study uses an existing framework to quantify MRI energy behavior, leading to insights that can enable improved performance and cost savings across different healthcare environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigating Benefits and Challenges of Converting Retiring Coal Plants into Nuclear Plants

A coal-to-nuclear (C2N) transition means siting a nuclear reactor at the site of a recently retired coal power plant. Three overarching questions from the C2N transition guide this research: where in the United States are retired coal facilities located and what factors make a site feasible for transition; what factors of technology, cost, and project timeline drive investor economics over such a decision; and how will C2N impact local communities? The study team evaluated the siting characteristics of recently retired plants and those operating coal-fired power plant sites run by a utility or an independent power producer utilizing publicly available data to screen U.S. coal power plant sites to nuclear-feasible locations. After screening all retired coal sites to a set of 157 potential candidates and screening operating sites to a set of 237 candidates, the study team estimates that 80% of retired and operating coal power plant sites that were evaluated have the basic characteristics needed to be considered amenable to host an advanced nuclear reactor. For the recently retired plant sites evaluated, this represents a capacity potential of 64.8 GWe to be backfit at 125 sites. For the operating plant sites evaluated, this represents a capacity potential of 198.5 GWe to be backfit at 190 sites. This report evaluates a case study for the detailed impacts and potential outcomes from a C2N transition. Based on the nuclear technology choices and sizes evaluated to replace a large coal plant of 1,200 MWe generation capacity at the case study site, nuclear overnight costs of capital could decrease by 15% to 35% when compared to a greenfield construction project, through the reuse of infrastructure from the coal facility. Nuclear replacement designs can have a lower capacity size because nuclear power plants run at higher capacity factors than coal power plants. In the case study replacing coal capacity with 924 GWe of nuclear capacity, the study team found regional economic activity could increase by as much as $\$275 million$ and add 650 new, permanent jobs to the region of analysis. The evaluated site choice in the report is hypothetical for analysis purposes only and based on available data and documented assumptions. Consequently, the findings only inform at a general level. A community, investor, or other interested stakeholder can use these results to set up a detailed, in-depth analysis for a specific application of interest, such as evaluating a C2N transition of a specific coal power plant and a specific nuclear technology design. The report was subjected to independent peer reviews by experts in systems engineering and regional economic modeling to evaluate analysis and assumptions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cost Analysis and Projections for U.S.-Manufactured Automotive Lithium-ion Batteries

This document reports on a study conducted to estimate the cost of U.S-produced automotive battery packs for model years (MY) 2023 to 2035, using Argonne National Laboratory’s BatPaC tool. The costs were estimated by designing batteries for several classes of vehicles for four discrete model years (2023, 2026, 2030, and 2035), where a representative battery technology and material prices are selected based on information available today. Correlations were developed from the four discrete years to enable annual pack cost estimates as a function of pack size (kWh) and model year. A consolidated cost curve was then developed that includes battery size, technology by model year, and the anticipated sales volumes of each class of vehicles over the years. This cost curve estimates the volume-averaged, U.S.-manufactured battery pack cost of PHEVs and BEVs in the United States to be $\$140$/kWh for the model year 2023, which will reduce to $\$86$/kWh in MY2035. Applying tax credits from section 45X of the Inflation Reduction Act can further reduce the average pack cost to as low as $\$56$/kWh in MY2029. The report also includes several sensitivity studies that investigate the effect of pack production volume, material prices, fast charge requirements, and labor rates.

25 ENERGY STORAGE↗

Conceptual Design of Pulverized Coal Electricity Generating Units for Flexible Operation

This National Energy Technology Laboratory (NETL) study addresses the conceptual design of greenfield pulverized coal (PC) plants intended for flexible rather than high capacity factor baseload operation. The United States has plentiful, low-cost natural gas resources - studies of aggressive decarbonization scenarios of the US energy sector suggest that the variability of carbon-free power can be economically addressed using dispatchable natural gas-fueled generation. Globally, natural gas resources are not as plentiful or low cost; consequently, some regions of the world are anticipated to continue to rely upon coal generation, even as they pursue decarbonization efforts. To support the increased utilization of variable renewable generation in these coal-dependent regions, plant designs must target low-capacity factor coal plants with increased emphasis on flexibility attributes such as start-up times, ramp rates, minimum load, and part-load heat rates. While much work has been performed on the improvement of the flexibility for existing coal plants originally designed for baseload service, little public literature exists on clean sheet design for flexible operation. This conceptual design study aims to define the features, performance characteristics, and costs for greenfield coal plants intended for flexible operation. Quantifying these characteristics provides critical information required by utility owners, grid planners, energy market modelers, and energy policy decision makers in coal-dependent regions of the world to better understand how coal-fired power plants can support a transition to low carbon generation.

20 FOSSIL-FUELED POWER PLANTS↗

An underground, wireless, open-source, low-cost system for monitoring oxygen, temperature, and soil moisture

Abstract. The use of wireless sensor networks to measure soil parameters eliminates the need to remove sensors for field operations, such as tillage, thus allowing long-term measurements without multiple disturbances to soil structure. Wireless sensors also reduce above-ground cables and the risk of undesired equipment damage and potential data loss. However, implementing wireless sensor networks in field studies usually requires advanced and costly engineering knowledge. This study presents a new underground, wireless, open-source, low-cost system for monitoring soil oxygen, temperature, and soil moisture. The process of system design, assembly, programming, deployment, and power management is presented. The system can be left underground for several years without the need to change the battery. Emphasis was given on modularity so that it can be easily duplicated or changed if needed and deployed without previous engineering knowledge. Data from this type of system have a wide range of applications, including precision agriculture and high-resolution modelling.

54 ENVIRONMENTAL SCIENCES↗

Optimization of harvest and logistics for multiple lignocellulosic biomass feedstocks in the northeastern United States

A mixed-integer linear programming model was developed to optimize the multiple biomass feedstock supply chains, including feedstock establishment, harvest, storage, transportation, and preprocessing. The model was applied for analyses of multiple biomass feedstocks at county level for 13 states in the northeastern United States. In the base case with a demand of 180,000 dry Mg/year of biomass, the delivered costs ranged from $\$67.90$ to $\$86.97$ per dry Mg with an average of $\$79.58$ /dry Mg. The biomass delivered costs by county were from $\$67.90$ to 150.81 per dry Mg across the northeastern U.S. Considered the entire study area, the delivered cost averaged $\$85.30$ /dry Mg for forest residues, $\$84.47$ /dry Mg for hybrid willow, $\$99.68$ for switchgrass and $\$97.87$ per dry Mg for Miscanthus. Seventy seven out of 387 counties could be able to deliver biomass at $84 per dry Mg or less a target set by US DOE by 2022. A sensitivity analysis was also conducted to evaluate the effects of feedstock availability, feedstock price, moisture content, procurement radius, and facility demand on the delivered cost. Lastly, our results showed that procurement radius, facility capacity, and forest residue availability were the most sensitive factors affecting the biomass delivered costs.

09 BIOMASS FUELS↗

Are low-cost sensors good enough for IAQ controls?

This study used laboratory testing to evaluate low-cost (about $\$ 200$ US) IAQ monitors that measured PM2.5 to determine if they are suitable for controlling IAQ for ventilation or air cleaning systems. Current Indoor Air Quality (IAQ) standards and approaches to minimizing pollutants depend almost exclusively on using dilution with outdoor air for some generic, continuously generated contaminant (e.g., ASHRAE Standard 62.2-2016). Some standards include measurement of CO 2 (e.g., EN 13779 standard (CEN, 2007) and NEN 8088 (NEN, 2011)) – however this is not because CO 2 itself is a pollutant of concern, but rather because it can be used as an occupancy indicator or as something that correlates with bioeffluents. Ideally, we would like to measure contaminant concentrations directly and ventilate to control their concentration within acceptable limits. This would ensure that concentrations do not got too high (as they can if emission rates exceed our assumptions) and also allow for ventilation reductions, and resulting energy savings, if concentrations are low. Until recently, it was impractical to consider direct contaminant control in residential (and many commercial) spaces due to the high cost and maintenance requirements for monitoring equipment. In the past couple of years low-cost sensors have been developed for some contaminants of concern – the greatest example of which is for particles. These sensors have been incorporated into low-cost (<$250 US) IAQ monitors. Finally, this has opened up the possibility of direct control of ventilation (and filtration systems) by sensing particles. However, it is important to evaluate these monitors to determine if their results are sufficiently good to control a ventilation system.

47 OTHER INSTRUMENTATION↗

Big Adaptive Rotor Phase I Final Report

The Big Adaptive Rotor (BAR) project was initiated by the U.S. Department of Energy (DOE) in 2018 with the goal of identifying novel technologies that can enable large (>100 meter [m]) blades for low-specific-power wind turbines. Five distinct tasks were completed to achieve this goal: 1. Assessed the trends, impacts, and value of low-specific-power wind turbines; 2. Developed a wind turbine blade cost-reduction road map study; 3. Completed research-and-development opportunity screening; 4. Performed detailed design and analysis; and, 5. Assessed low-cost carbon fiber. These tasks were completed by the national laboratory team consisting of Sandia National Laboratories (Sandia), the National Renewable Energy Laboratory (NREL), and Lawrence Berkeley National Laboratory.

17 WIND ENERGY↗

Review of Feasibility and Cost Drivers for Floating Offshore Wind Energy in Washington State

The state of Washington must double its clean electricity supply by 2050 to meet its clean energy goals and comply with the Clean Energy Transformation Act. With more than 6.6 GW of technical resource potential in federal waters where Bureau of Ocean Energy Management has leasing authority, offshore wind energy could play an important role in diversifying Washington State's clean energy mix, reducing dependence on out-of-state energy sources, and helping meet state decarbonization goals. Decision makers need technology-specific information to assist with long-term energy system planning, so the Bureau of Ocean Energy Management requested that the National Renewable Energy Laboratory provide an overview of several drivers of offshore wind energy feasibility and cost in Washington. This study summarizes some of the existing engagement efforts and perspectives on offshore wind energy in the region and quantifies the offshore wind resources in Washington as well as technology costs and performance of potential projects. Furthermore, this report reviews existing grid and port infrastructure and discusses infrastructure needs along with information gaps. This study also explores opportunities and barriers to Washington entities supporting the broader floating offshore wind energy supply chain along the U.S. West Coast. Note that this study is not part of a formal project planning process or official engagement effort, nor does it assess environmental or economic impacts from potential offshore wind energy development.

17 WIND ENERGY↗

Adoption of Plug-in Electric Vehicles: Local Fuel Use and Greenhouse Gas Emissions Reductions Across the U.S.

The dependence on gasoline-powered light-duty automobiles has made U.S. households vulnerable to the burden of fuel costs. Tailpipe emissions from these vehicles constitute 58% of greenhouse gas (GHG) emissions in the U.S., which are damaging to the environment (EPA, 2023). The adoption of plug-in electric vehicles (PEVs) has been shown to effectively reduce fuel costs and GHG emissions. However, local effects on these benefits are not well understood by American consumers, potentially limiting adoption and therefore the realization of PEV benefits at scale (MacInnis & Krosnick, 2020; EY Americas, 2023). To fill this research gap, this study estimates the fuel cost savings and GHG emission reductions at the state and ZIP code levels by considering local fuel prices, vehicle class preference, average vehicle model year, fuel efficiencies, and driving intensities. The study's findings reveal that the adoption of PEVs can yield substantial benefits in terms of fuel cost savings and GHG emission reductions nationwide. Specifically, driving a battery electric vehicle (BEV) is estimated to result in annual savings of up to $\$2,200$, while driving a plug-in hybrid electric vehicle (PHEV) can lead to savings up to $\$1,500$, when compared to an internal combustion engine vehicle (ICEV) of equivalent size. Moreover, using population-weighted averages by ZIP code, BEVs and PHEVs show the potential to save 400 and 200 grams of carbon dioxide equivalent per mile, respectively, compared to a representative ICEV of the same class. The magnitude of fuel cost savings and emissions reduction vary by region due to various factors. Generally, regions with high gasoline prices, low electricity prices, preferences for larger vehicles, and high driving intensities tend to see relatively large fuel savings. The emissions reductions are more pronounced in areas with clean grids where consumer preferences lie with large vehicles. This regional variability underscores the importance of considering local contextual factors when assessing the potential benefits of PEV adoption. In more than 99% of U.S. ZIP codes, PEVs result in overall savings in fuel use (and subsequent costs) and GHG emissions. While not a central focus of this analysis, reductions in GHG tailpipe emissions from PEV adoption would also come with reductions in criteria pollutant emissions, contributing to improved local air quality depending on the PEV penetration, population density, and electricity generation infrastructure in the locality.

33 ADVANCED PROPULSION SYSTEMS↗

Providing Levelized Cost and Waiting Time Inputs for HDV Hydrogen Refueling Station Planning: A Case Study of U.S. I-75 Corridor

Widespread use of diesel fuels in freight transportation leads to greenhouse gas (GHG) emissions that play an important role in air pollution. The air pollution, as well as the energy crisis, drives the transition from diesel fuel to cleaner and more energy-efficient fuels such as hydrogen fuels. With such a transition, the strategic planning and optimization of supporting refueling infrastructure along the national highway for heavy-duty vehicles (HDVs) become a necessity. Cost and service level are two essential factors to be considered in hydrogen refueling station location and capacity optimization. The service level in this study is assessed by the delay (waiting time) at fueling stations as well as the fueling demand fulfilled. To this end, this study presents a methodology to provide waiting time (delay) and levelized hydrogen fuel cost inputs under different station configurations (number of dispensers and fill rates) for hydrogen refueling station planning. Determining the station configurations based on the trade-off between the two inputs is further discussed. Particularly, this study points out that the levelized cost and waiting time are affected by hourly demand patterns and estimates the two inputs under different peak hour fueling demand scenarios. The results suggest that, with the same daily demand, the cost, as well as the waiting time, increases obviously with the peak hour demand. In the case study, the cost grows at least 30% when the peak hour visit frequency of the daily total visits increases from 5% (evenly distributed pattern) to 10% (the most common pattern for existing diesel fueling stations along I-75). Accounting for this peak hour effect in hydrogen refueling station planning is recommended. Overall, the waiting time model and cost analysis provide key inputs for optimizing hydrogen refueling station location and configurations based on anticipated refueling demand patterns. The paper is the second in a series that aims to build a comprehensive modeling plan and optimize hydrogen refueling infrastructure along the Interstate 75 (I-75) corridor for HDVs.

Liu, Yuandong↗

Analysis of different operating strategies of thermal energy storage with radiant cooling system

Thermal energy storage systems in building cooling applications have been explored extensively as a peak load-shifting technology. Thermal energy storage performance has been recognized and studied from an energy cost-savings point of view because of peak-valley price differences, but not many studies have been conducted from an energy savings viewpoint. This study experimentally investigates the performance of the energy storage-retrofitted to a ceiling-type radiant cooling system. To study the performance, a water-based storage system was designed and developed for an academic office building equipped with a radiant cooling system. The water in the storage tank was cooled to a certain storage temperature in the nighttime, and the same water was used during the daytime for meeting the cooling load. Different combinations of charging and discharging schedules were analyzed. The key objective of the study was to achieve energy savings and energy-cost savings simultaneously. This objective was accomplished by identifying the major factors contributing to the energy consumption of the storage-retrofitted cooling system and devising novel operating strategies, leading to an enhanced energy savings potential. Two operating strategies comprising 24 operating scenarios were compared and the storage was used to dispatch the load for 3 hours of the day as a full storage unit. Results showed that in hot and dry climate conditions, using the storage with the radiant cooling system offered energy savings of 3% to 14%. The energy-cost analysis was also performed using a time-of-day electricity tariff plan. The energy-cost savings varied from 17.5% to 22.4% for these operating scenarios.

25 ENERGY STORAGE↗

Two-stage membrane-based process utilizing highly CO 2 -selective membranes for cost and energy efficient carbon capture from coal flue gas: A process simulation study

Membrane technology for CO 2 capture has become an attractive strategy due to its cost and energy efficiency and low materials costs. In the past decade, membrane-based process designs for post-combustion power plant CO 2 capture have been developed, utilizing existing highly CO 2 -permeable membranes with relatively low CO 2 /N 2 selectivity (<50), and have obtained reasonably economic carbon capture. However, few membrane-based process designs were proposed for moderate to highly CO 2 -selective membranes (CO 2 /N 2 selectivity of 50–300, and >300, respectively), which have vastly emerged in recent years, such as various facilitated transport membranes (FTMs). Herein, we proposed a two-stage membrane-base process design targeting economic carbon capture from coal-fired flue gas. This process design features the utilization of highly CO 2 -selective membranes for one-stage CO 2 enrichment to 95% dry-base purity in the first stage and recycle of the remaining CO 2 by a highly CO 2 -permeable membrane in the second stage, in order to achieve economic CO 2 capture with 90% capture rate and >95% CO 2 product purity. Through an integration-iteration membrane model and the Aspen Plus process simulation, a sensitivity study of operating pressures (feed and permeate pressures) and membrane properties (CO 2 permeance and CO 2 /N 2 selectivity) was conducted. Critical CO 2 /N 2 selectivity of 300–400 was found for the highly CO 2 -selctive membranes to meet the demand for cost and energy efficient results. The lowest possible membrane area of 4.8 × 10 5 m 2 and fractional energy of 19.3% were obtained, which is comparable to or even more attractive than reported membrane-based process designs. Here, this work provides a new membrane process design option for highly CO 2 -selective membranes and gives insights on the influence of membrane performance and operation condition.

42 ENGINEERING↗

The Current State of Light-Duty Electric Vehicle Supply Equipment Costs: An Assessment of Contemporary Understanding

This study uses a hybrid meta-analysis and literature-review approach to understand the current state of knowledge regarding the costs of electric vehicle supply equipment (EVSE). We present a novel way to consider, categorize, and label measures of cost and show cost measure estimates from a sample of 13 recent studies. We find that in general, there is too much variation and too few commonly represented EVSE cost measures to reasonably provide aggregate figures for these measures. We propose a convention for presenting EVSE cost measures that includes the application (commercial or residential), the power level (Level 1, Level 2, DCFC [with further distinction based on rated power capacity]), and the type of cost measure (hardware, installation, operation, and total cost). We contend that providing researchers with standard cost measures will help to advance our knowledge of EVSE costs by ensuring that future work will use common metrics. Establishing common metrics will enable conventional meta-analyses that will make assessments of EVSE costs even more accessible. Additionally, common metrics will make tracking costs more reliable as the technology continues to evolve and become more ubiquitous.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Cost of Offshore Wind Energy in the United States From 2025 to 2050

This study presents estimates of the levelized cost of energy (LCOE) of offshore wind energy throughout major U.S. coastal regions between a time frame of 2025 - 2050. The LCOE modeling accounts for impacts of supply chain shocks, inflation, and rising interest rates on cost. Given the near-term uncertainty in these factors, we present three possible scenarios driven by how uncertainty in costs, technology, and deployment may evolve over time. The cost increases reported by industry in recent years will likely be felt over next several years, but we expect long-term cost reductions enabled by growing offshore wind deployment and industry learning. This study helps inform decision-makers about the potential role that offshore wind energy can play in future clean energy strategies.

17 WIND ENERGY↗

High Temperature Copper Metallization: Demand, Hurdles and Reliability

As newer cells structures come online, the pressing need to replace silver in the metallization pastes has renewed interest in alternative technologies employing base metals. Copper typically leads the charge with its abundance and lower cost but has faced numerous obstacles from relatively higher oxidation and diffusion rates which can damage the lifetime of the devices. In this study, a low-cost alternative to silver metallization pastes has been shown on PERC cells. The screen printable copper paste can be fired in air at temperatures >500 degrees C, and the impact of processing conditions and equipment on the performance and reliability of 274 cm2 cells have been evaluated. Through damp heat testing of micro-modules using 16 cm2 cells, routes that can lead to both the failure and success of durable contacts have been demonstrated.

copper↗

Bituminous Coal and Natural Gas to Electricity: >90% Capture Cases Technical Note

This technical note provides cost and performance estimates for post combustion carbon capture (PCCC) systems designed for greater than 90 percent capture on conventional PC- and NG-fueled power plants. The cost and performance estimates provided here were developed using the National Energy Technology Laboratory’s (NETL’s) well-documented methodology for conducting technoeconomic analysis of fossil energy conversion systems and leveraging published performance and cost projections for higher capture rate systems. Included in this technical note is a brief description of the method used to adjust select 90 percent capture cases from NETL’s Cost and Performance Baselines for Fossil Energy Systems Volume 1: Bituminous Coal and Natural Gas to Electricity, hereafter referred to as the Baseline Study. This technical note is intended to serve as an interim update to NETL’s Baseline Study cases by providing cost and performance estimates for high capture PCCC technology that can be deployed in the near-term at fossil-fueled electricity generating units.

20 FOSSIL-FUELED POWER PLANTS↗