Search NASA⌕ Search

SEARCH · Search NASA

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Population statistics of faint stellar and non-stellar objects

A disc and halo population model is constructed to fit star counts and color data down to V approximately 23 at absolute value of b = 90 deg. This model is used to predict star counts and colors down to V approximately 30. Deviations from these extrapolated relationships provide constraints on the number of faint quasars and black dwarf stars. It is shown that extra-galactic globular clusters start contributing significantly to star counts at V approximately 25 and are more numerous than stars for V 31. Morphological studies of galaxies with approximately 0.5, were made with the space telescope. Significant constraints on theoretical models that describe the evolution of clusters of galaxies are provided.

Vandenbergh, S.↗

Second ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The aerosol chemical speciation monitor (ACSM) was developed to adapt the technology of the aerosol mass spectrometer (AMS) to routine, long-term, standalone monitoring. The calculation of particulate mass concentration from ACSM data requires the measurement of the response of the instrument to aerosol of specific size and composition as well as assumptions about the instrument response based on laboratory measurements and field experience acquired over more than two decades of operation of AMS and a decade of operation of the ACSM. Three parameters in the concentration calculations that are particularly important are the NO3 response factor (RFNO3), relative ionization efficiency (RIE), and the collection efficiency (CE). The values of RFNO3 and RIEs are determined from calibration, however the jump calibration method previously used in calibration can result in errors in the RIE for sulfate. This has been corrected by implementing a continuous calibration method. The default collection efficiency is 0.5. This has been shown to result in mass loadings that do not agree with mass determinations from other instruments because of effects of composition on the vaporization of the particles. The previous work of investigators addressing this issue is discussed. After preliminary work on ACSM and scanning mobility particle sizer (SMPS) data from the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) observatory collected in late 2016 and 2017 produced a parameterization of composition dependent collection efficiency very different from the results of previous studies, SMPS data were examined and we determined that there was significant mass that the instrument did not capture because the particles with diameters larger than 465 nm are not counted by this instrument. Data for the ultra-high-sensitivity aerosol spectrometer (UHSAS), SMPS, and ACSM are available for nearly all of 2019. The data from UHSAS and SMPS collected in 2019 were compared. We found that the UHSAS data has particle counts and total volumes significantly less than measured by the condensation particle counter (CPC) and SMPS. The SMPS data were extended by fitting the average volume distribution with a log normal curve and using this relationship to estimate a mass value for the SMPS over extended diameter range. The extended SMPS mass values result in a CDCE parameterization that is in better agreement with the results of other investigators, but is still different from other formulations. The working group recommends that the ACSM data be processed with a collective efficiency (CE)=1, that this be documented clearly in the metadata, and the use of the default CE of 0.5 or a formulation of composition-dependent collection efficiencies (CDCE) chosen by the user should be implemented based on the ammonium nitrate mass fraction. This is clearly necessary for the wintertime SGP ACSM data because of the high nitrate concentrations.

47 OTHER INSTRUMENTATION↗

High-count rate effects in event processing for XRISM/ Resolve X-ray microcalorimeter: I. Ground test

The spectroscopic performance of an X-ray microcalorimeter is compromised at high count rates. We utilize the Resolve X-ray microcalorimeter onboard the XRISM satellite to examine the effects observed during high-count rate measurements and propose modeling approaches to mitigate them. We specifically address the following instrumental effects that impact performance: CPU limit, pile-up, and untriggered electrical cross-talk. Experimental data at high count rates were acquired during ground testing using the flight model instrument and a calibration X-ray source. In the experiment, data processing not limited by the performance of the onboard CPU was run in parallel, which cannot be done in orbit. This makes it possible to access the data degradation caused by limited CPU performance. We use these data to develop models that allow for a more accurate estimation of the aforementioned effects. To illustrate the application of these models in observation planning, we present a simulated observation of GX 13+1. Understanding and addressing these issues is crucial to enhancing the reliability and precision of X-ray spectroscopy in situations characterized by elevated count rates.

47 OTHER INSTRUMENTATION↗

Application of the Tasseled Cap concept to simulated thematic mapper data

Thematic Mapper signal counts in the six reflective bands (i.e., excluding the thermal band) are simulated using field and laboratory spectrometer measurements of a variety of crops, crop conditions, and soil types. The Dave atmospheric model and prelaunch sensor characteristics comprise the other components of the simulation. The simulated data are found to occupy essentially three dimensions, two of which are equivalent to the MSS Tasseled Cap Greennes and Brightness features, and a third which is substantially influenced by the mid-infrared bands of the TM. This new dimension is primarily related to soil characteristics, including soil moisture. The nature and characteristics of each dimension are discussed, as are some of the expected information gains (over MSS data) resulting from the additional dimensionality of the data.

Crist, E. P.↗

Surrogate Distributed Radiological Sources—Part II: Aerial Measurement Campaign

In this second part of a multipaper series, we present results from outdoor aerial measurements of surrogate distributed gamma-ray sources. Here we detail the design, manufacture, and testing of 300 individual ~7 mCi Cu-64 sealed sources at the Washington State University (WSU) research reactor and their deployment in various source patterns (each comprising up to 100 point sources) during the aerial measurement campaign. We show the results of two such measurements, in which approximate source shapes and qualitative source intensities can be seen from the count rate versus position plots, even without performing reconstructions. We also detail our efforts in ground-truthing the deployed sources and comparing measured gamma-ray data to model predictions. In particular, we compare measured versus expected count data using the Poisson deviance formalism of Part I to evaluate whether the fielded surrogate point-source arrays “look like” their truly continuous distributed source analogs. More generally, we find that the point-source array technique provides high source placement accuracy, relative ease of quantifying the true source configuration, scalability to source dimensions of ≲100 m, ease of reconfiguration and removal, and relatively low dose to personnel. Finally, we consider potential improvements and generalizations of the point-source array technique for future measurement campaigns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel Photon-Counting Detectors for Free-Space Communication

We present performance data for novel photon-counting detectors for free space optical communication. NASA GSFC is testing the performance of two types of novel photon-counting detectors 1) a 2x8 mercury cadmium telluride (HgCdTe) avalanche array made by DRS Inc., and a 2) a commercial 2880-element silicon avalanche photodiode (APD) array. We present and compare dark count, photon-detection efficiency, wavelength response and communication performance data for these detectors. We successfully measured real-time communication performance using both the 2 detected-photon threshold and AND-gate coincidence methods. Use of these methods allows mitigation of dark count, after-pulsing and background noise effects. The HgCdTe APD array routinely demonstrated photon detection efficiencies of greater than 50% across 5 arrays, with one array reaching a maximum PDE of 70%. We performed high-resolution pixel-surface spot scans and measured the junction diameters of its diodes. We found that decreasing the junction diameter from 31 micrometers to 25 micrometers doubled the e- APD gain from 470 for an array produced in the year 2010 to a gain of 1100 on an array delivered to NASA GSFC recently. The mean single-photon SNR was over 12 and the excess noise factors measurements were 1.2-1.3. The commercial silicon APD array exhibited a fast output with rise times of 300 ps and pulse widths of 600 ps. On-chip individually filtered signals from the entire array were multiplexed onto a single fast output.

Photons↗

Should the Standard Count Be Excluded from Neutron Probe Calibration?

About 6 decades after its introduction, the neutron probe remains one of the most accurate methods for indirect measurement of soil moisture content. Traditionally, the calibration of a neutron probe involves the ratio of the neutron count in the soil to a standard count, which is the neutron count in the fixed environment such as the probe shield or a specially-designed calibration tank. The drawback of this count-ratio-based calibration is that the error in the standard count is carried through to all the measurements. An alternative calibration is to use the neutron counts only, not the ratio, with proper correction for radioactive decay and counting time. To evaluate both approaches, the shield counts of a neutron probe used for three decades were analyzed. The results show that the surrounding conditions have a substantial effect on the standard count. The error in the standard count also impacts the calculation of water storage and could indicate false consistency among replicates. The analysis of the shield counts indicates negligible aging effect of the instrument over a period of 26 years. It is concluded that, by excluding the standard count, the use of the count-based calibration is appropriate and sometimes even better than ratio-based calibration. The count-based calibration is especially useful for historical data when the standard count was questionable or absent

54 ENVIRONMENTAL SCIENCES↗

Neutral point detection by satellites

The concept of a neutral point depends on the physical phenomena described. The regions with B less than about 1 gamma detected by Schindler and Ness may be interpreted as neutral regions for the ion-tearing process. The assumption of the presence of a multiple neutral point structure (with temporal variations) is still the most promising interpretation of the Explorer 34 data. Alternatives suggested by Russell lead to difficulties. Nevertheless, the final answer can come only from multiple satellite systems. A 1-day displacement of the day count in the data discussed by Schindler and Ness is corrected.

Schindler, K.↗

Analysis of calibration data for the uranium active neutron coincidence counting collar with attention to errors in the measured neutron coincidence rate

The declared linear density of 238 U and 235 U in fresh low enriched uranium light water reactor fuel assemblies can be verified for nuclear safeguards purposes using a neutron coincidence counter collar in passive and active mode, respectively. The active mode calibration of the Uranium Neutron Collar - Light water reactor fuel (UNCL) instrument is normally performed using a non-linear fitting technique. The fitting technique relates the measured neutron coincidence rate (the predictor) to the linear density of 235 U (the response) in order to estimate model parameters of the nonlinear Parte equation, which traditionally is used to model the calibration data. Alternatively, following a simple data transformation, the fitting can also be performed using standard linear fitting methods. This article compares performance of the nonlinear technique to the linear technique, using a range of possible error variance magnitudes in the measured neutron coincidence rate. We develop the required formalism and then apply the traditional (nonlinear) and alternative approaches (linear) to the same experimental and corresponding simulated representative datasets. Here, we find that, in this context, because of the magnitude of the errors in the predictor, it is preferable not to transform to a linear model, and it is preferable not to adjust for the errors in the predictor when inferring the model parameters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of processing algorithms to enable high-rate microcalorimeter array operation

The millisecond-scale decay constants of microcalorimeter gamma-ray pulses present challenges for operation at high count rates needed to compete with semiconductor HPGe detectors. If using conventional optimal filtering methods, pulse records with pileup events are simply discarded, leading to a large fraction of data unused when count rates are large. For single pixel rates exceeding 1-2 Hz, improved pulse processing algorithms are needed to better deal with pileup and increase the filter throughput. A 256-pixel array operating at 10 Hz per pixel would provide a total counting rate of 2.5 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fractal Dimension Calculation for Big Data Using Box Locality Index

The box-counting approach for fractal dimension calculation is scaled up for big data using a data structure named box locality index (BLI). The BLI is constructed as key-value pair style with the key (an integer array) indexing the location of a “box” (i.e., a gird cell on the multi-dimensional space embedding a given dataset) and the value counting the number of data points inside the box (called “box occupancy”). Compared with the traditionally used E-dim tree, the BLI avoids complex hierarchical structure and encodes only necessary information required by box-counting approach for fractal dimension calculation. Moreover, the key-value pair nature of BLI, together with the fact that the box occupancy is aggregatable, grants box-counting approach the needed scalability for fractal dimension calculation of big data using distributed computing techniques (e.g., MapReduce and Spark). Taking the advantage of the BLI, MapReduce and Spark methods for fractal dimension calculation of big data are developed, which conduct box-counting for each grid level as a cascade of MapReduce/Spark jobs in a bottom-up fashion. In an empirical validation, the MapReduce and Spark methods demonstrated good effectiveness and efficiency in fractal calculation of a big synthetic dataset. In summary, this work provides an efficient solution for the estimation of intrinsic dimension of big data that is essential for many machine learning methods and data analytics.

Fractal dimension, Intrinsic dimension, Box-counti↗

Alpha Air Sample Counting Efficiency Versus Dust Loading: Evaluation of a Large Data Set

Dust loading on air sample filters is known to cause a loss of efficiency for direct counting of alpha activity on the filters, but the amount of dust loading and the correction factor needed to account for attenuated alpha particles is difficult to assess. In this paper, correction factors are developed by statistical analysis of a large database of air sample results for a uranium and plutonium processing facility at the Savannah River Site. As is typically the case, dust-loading data is not directly available, but sample volume is found to be a reasonable proxy measure; the amount of dust loading is inferred by a combination of the derived correction factors and a Monte Carlo model. The technique compares the distribution of activity ratios [beta/(beta + alpha)] by volume and applies a range of correction factors on the raw alpha count rate. The best-fit results with this method are compared with MCNP modeling of activity uniformly deposited in the dust and analytical laboratory results of digested filters. Finally, a linear fit is proposed to evenly-deposited alpha activity collected on filters with dust loading over a range of about 2 mg cm -2 to 1,000 mg cm -2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An IEEE 1451.1 Architecture for ISHM Applications

The IEEE 1451.1 Standard for a Smart Transducer Interface defines a common network information model for connecting and managing smart elements in control and data acquisition networks using network-capable application processors (NCAPs). The Standard is a network-neutral design model that is easily ported across operating systems and physical networks for implementing complex acquisition and control applications by simply plugging in the appropriate network level drivers. To simplify configuration and tracking of transducer and actuator details, the family of 1451 standards defines a Transducer Electronic Data Sheet (TEDS) that is associated with each physical element. The TEDS contains all of the pertinent information about the physical operations of a transducer (such as operating regions, calibration tables, and manufacturer information), which the NCAP uses to configure the system to support a specific transducer. The Integrated Systems Health Management (ISHM) group at NASA's John C. Stennis Space Center (SSC) has been developing an ISHM architecture that utilizes IEEE 1451.1 as the primary configuration and data acquisition mechanism for managing and collecting information from a network of distributed intelligent sensing elements. This work has involved collaboration with other NASA centers, universities and aerospace industries to develop IEEE 1451.1 compliant sensors and interfaces tailored to support health assessment of complex systems. This paper and presentation describe the development and implementation of an interface for the configuration, management and communication of data, information and knowledge generated by a distributed system of IEEE 1451.1 intelligent elements monitoring a rocket engine test system. In this context, an intelligent element is defined as one incorporating support for the IEEE 1451.x standards and additional ISHM functions. Our implementation supports real-time collection of both measurement data (raw ADC counts and converted engineering units) and health statistics produced by each intelligent element. The handling of configuration, calibration and health information is automated by using the TEDS in combination with other electronic data sheets extensions to convey health parameters. By integrating the IEEE 1451.1 Standard for a Smart Transducer Interface with ISHM technologies, each element within a complex system becomes a highly flexible computation engine capable of self-validation and performing other measures of the quality of information it is producing.

Morris, Jon A.↗

Serial data transmission between redundant channels

Data is communicated between redundant channels formatted in blocks having an initial command word followed by a destination code, starting address and a variable number of data words including a word count. The blocks are transmitted between each channel and all of the channels over cross-channel data links, each channel receiving the data blocks and determining the validity thereof by counting the number of data words received and comparing that number to the word count transmitted for that block. An interrupt signal indicative of invalidity of a block is provided in the event of a miscompare. A stop address is generated for each block received for storage at the start address. A memory address is generated for each valid word received for storage in sequence starting immediately after the start address. The next block received has its start address placed immediately at the end of the previously received block.

Tulpule, Bhalchandra R.↗

Apollo window meteoroid experiment

Apollo window meteoroid experiment for obtaining data from crater counts and analysis of meteoroid residue combined with fused glass in described. A preliminary estimate of the flux resulting from seven Apollo spacecraft is found to be in agreement with the Surveyor 3 data, but is lower than the model environment.

Cour-Palais, B. G.↗

Coordinated XTE Observations of Coronal Structure and Flares on the Rs CVn Binary Sigma(sup 2) CrB

This NASA grant supported my RXTE observing and data analysis during AO2. The research involved a 100 kilosecond observation of the active RS CVn binary sigma(sup 2) CrB obtained on 1997 March 11-13. This observation covered two orbits of the binary (2.5 days elapsed time) as part of a coordinated satellite and ground-based study of coronal structure and flaring within this system. Simultaneous data was obtained from the ASCA X-ray satellite and the Very Large Array radio telescope. The one month of effort funded for the PI was used to calibrate and analyze the RXTE data. Additional research effort on this project to lead to a final publication has been provided from LTSA and GSRP grants. An initial attempt was made to calibrate the RXTE data in May 1997 but the results were disappointing with poor background subtraction leading to a relatively noisy PCA light curve. Subsequently major improvements have been made in the calibration techniques for low count rate PCA data and we returned to Goddard Space Flight Center in February 1999 when we were able to produce vastly better calibrated data. The RXTE results are currently being integrated with the ASCA and VLA data and a paper should be submitted by the end of summer 1999.

Brown, Alexander↗

Design and Validation Testing of TruckScan to Assay Large Sacks of Fukushima Radioactive Debris on a Truck

As a result of the March 2011 earthquake and resulting tsunami in Japan, there was a serious accident at the Fukushima Dai-ichi Nuclear Power Plant. This accident has contaminated soil and vegetation in a wide area around the plant. Decontamination projects over the last 4 years have resulted in large numbers of 1 cubic meter canvas bags of debris, commonly called Super Sacks [SS]. These are currently stored nearby where they were generated, but starting in 2015, they will be moved to various Interim Storage Facilities [ISF]. Trucks will typically carry 8-20 of these SSs. When the trucks arrive at the ISF they need to be rapidly sorted into groups according to radioactivity level, for efficient subsequent processing. Canberra Industries, Inc. [CI] has designed a new truck monitoring system 'TruckScan' for use at these ISFs. The TruckScan system must measure the entire truck loaded with multiple closely packed SSs, and generate a nuclide specific assay report showing the radioactivity in each individual SS. The Canberra-Japan office, along with Obayashi Corporation have performed validation testing to demonstrate to the regulatory authorities that the proposed technique was sufficiently accurate. These validation tests were conducted at a temporary storage area in Fukushima prefecture. Decontaminated waste of various representative types and of various levels of radioactivity was gathered and mixed to create homogeneous volumes. These volumes were sampled multiple times and assayed with laboratory HPGe detectors to determine the reference concentration of each pile. Multiple SSs were loaded from each pile. Some of the SSs were filled 50% full, others 75% full, and others 100% full, to represent the typical loading configuration of the existing SSs in the field. The content of the SSs are either sand, soil, or vegetation with densities ranging from 0.3 g/cc - 1.6 g/cc. These SSs with known concentrations of Cs-134 and Cs-137 were then loaded onto trucks in a variety of configurations, typical of how they might be on the real trucks. A partial system was installed at the site and used to assay these trucks with the various loading configurations. Whereas the full system will have 8 collimated 3 x 3'' NaI detectors, the test system only had two detectors; therefore the truck was moved and counted 4 times. The data were acquired and analyzed with the Canberra Genie software to determine the peak counts for both Cesium nuclides. That data was then analyzed with a prototype version of a Maximum Entropy algorithm, to determine the individual SS activity. The goal of the validation tests was to demonstrate that the system could detect 1000 Bq/kg in 15 seconds, and to determine how accurately it could quantify individual SSs. The validation tests demonstrated that the product would perform as predicted. The TruckScan results were consistent with the sample assay results [y = 1.0029 x, R{sup 2} = 0.914]. The Total Propagated Uncertainty, including both uncertainties from these tests and others that were estimated but not tested was 16.6% percent. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Revisiting galactic black hole binary GX 339-4 by using 2007 – 2014 Swift XRT observations

This work aims to study the X-ray properties of the galactic black hole binary GX 339-4. Focus of the study is on exploration of data from Swift-XRT in exclusively photon-counting mode. We use data from 2007 up to August 2014, which contain about 40 pointing observations with level 1 data. The flux of GX 339-4 varies in a factor of 100 during this period of observations. For the purpose of this work, we also try to develop a system to conduct standard SWIFT XRT data reduction automatically, in order to greatly reduce time when working with data bulk, which produces images, lightcurves as well as spectra. We also develop another system to conduct fitting of bulk spectral data with a two-component model, disk blackbody and power-law. The fitting results show that no data have a reduced chi-squared > 2. The fraction of the disk to total flux and the power-law to total flux range from 0.00389 – 0.994 and 0.00605 – 0.996, respectively. From the analysis of the disk component, we obtain the value of the innermost disk radius that does not show any large scale truncation which is in a good agreement with a previous study that used 2007 – 2011 Swift-XRT data, indicating that the systems we developed work properly.

79 ASTRONOMY AND ASTROPHYSICS↗