Search NASA⌕ Search

SEARCH · Search NASA

Results for “counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Preliminary Experiences with the Rexon UL-320-FDR: An Automated Thermoluminescent Dosimeter Reader with Removable Contact Heating Planchets and an Infrared Temperature Feedback System

The Rexon UL-320 FDR is a novel resistive-heating thermoluminescent dosimeter reader with a unique temperature measurement system and an automated dosimeter processing mechanism. The removable contact heating planchets have black-body adhesives on the back for capturing temperature information with infrared sensors. A heating cycle feedback loop ensures accurate, precise, and reproducible heating sequences. Heating rates between 0.8 and 40°C s -1 for up to 1,000 s are possible. Photomultiplier tube sensitivity and drift, dark current counts, and planchet glow were measured experimentally. Additionally, 25 LiF:Mg,Ti dosimeters were calibrated to demonstrate reader performance. Sensitivity was optimized at 1,200 V, which produced the highest reference light count to dark current count ratio while extending photomultiplier tube life. Dark current counts measured with typical time-temperature profiles for LiF:Mg,Ti were below 10 counts per channel but increased by up to 2.5% for more extreme heating cycles. Reader sensitivity drifts of up to 10% were observed during extended automated operations with typical time-temperature profiles. Total counts resulting from planchet glow decreased with faster heating rates. Calibrations performed with LiF:Mg,Ti dosimeters yielded results comparable to more established reader designs. Spikes were observed in ~3% of the glow curves from planchet dust and oil burning off at elevated temperatures. The use of N 2 gas and sensitivity drift corrections are recommended to improve dosimetry performance for the UL-320 FDR reader.

61 RADIATION PROTECTION AND DOSIMETRY↗

Feasibility of Correlation-Aware Inference and Universal Precision Scaling in Bonse–Hart Ultra-Small-Angle Neutron Scattering

Bonse–Hart ultra-small-angle neutron scattering (USANS) provides access to micrometre-scale structure, but useful measurements often require long counting times. In this work, we test whether the expected smoothness of the scattering profile can be exploited to improve data quality at lower counting statistics. We apply a Gaussian-process-based method to Bonse–Hart USANS data and evaluate its performance on pseudo-measurements generated from high-statistics experiments under Poisson statistics. This provides a stringent test of how well the underlying I(Q) profile can be reconstructed when the available counts are substantially reduced. We further show that, in the counting-limited regime, the reconstruction error follows a universal scaling behaviour that differs from the usual independent-counting expectation. At higher counts, the improvement crosses over to a resolution-limited regime set by analyser-angle discretization and rocking-curve width. These results clarify when correlation-aware inference is useful in USANS and provide a practical basis for improving measurement efficiency and beam-time usage.

Tung, Chi-Huan [ORNL] (ORCID:0000000221972074)↗

High–throughput measurement of plant fitness traits with an object detection method using Faster R–CNN

Revealing the contributions of genes to plant phenotype is frequently challenging because loss-of-function effects may be subtle or masked by varying degrees of genetic redundancy. Such effects can potentially be detected by measuring plant fitness, which reflects the cumulative effects of genetic changes over the lifetime of a plant. However, fitness is challenging to measure accurately, particularly in species with high fecundity and relatively small propagule sizes such as Arabidopsis thaliana. An image segmentation-based method using the software ImageJ and an object detection-based method using the Faster Region-based Convolutional Neural Network (R-CNN) algorithm were used for measuring two Arabidopsis fitness traits: seed and fruit counts. The segmentation-based method was error-prone (correlation between true and predicted seed counts, r 2 = 0.849) because seeds touching each other were undercounted. By contrast, the object detection-based algorithm yielded near perfect seed counts (r 2 = 0.9996) and highly accurate fruit counts (r 2 = 0.980). Comparing seed counts for wild-type and 12 mutant lines revealed fitness effects for three genes; fruit counts revealed the same effects for two genes. Our study provides analysis pipelines and models to facilitate the investigation of Arabidopsis fitness traits and demonstrates the importance of examining fitness traits when studying gene functions.

59 BASIC BIOLOGICAL SCIENCES↗

An Evaluation of a Neutron Time Correlated Interrogation Method for Measurement of Fissile Content in Research Reactor Spent Fuel Assemblies

There are many research reactors worldwide that have been, or are being converted from the use of high enrichment uranium (HEU) to low enrichment uranium (LEU, < 20% enriched). The verification of fissile content and initial enrichment of the spent fuel is needed for the effective safeguards of the fuel. The advanced experimental fuel counter (AEFC) was developed for the measurement of spent fuel rods and assemblies from research reactors for safeguards verification. This measurement system contains components for active neutron interrogation, passive neutron totals counting, neutron coincidence counting, and gross gamma-ray counting. This report presents the first application of the time correlated interrogation technique for the measurement of the 235 U content in research reactor spent fuel assemblies. The technique, called time correlated induced fission (TCIF), uses a 252 Cf neutron source to irradiate the fuel assembly, and the subsequent induced fission events in the fissile material are measured by coincidence counting. The doubles rates are enhanced by having the neutron trigger events from both the 252 Cf source and the induced fission neutrons in the same time gate in the coincidence analysis. The average neutrons per fission of the 252 Cf source is 3.76 and the induced fission neutrons for 235 U is 2.44, so the number of neutrons that are produced is higher than for random neutron interrogation. This high effective neutron number increases the multiplicity counting rates and reduces the statistical error. The background coincidence counts from the 252 Cf are reduced by the water in the sample cavity and the polyethylene surrounding the 3 He detector tubes. This method of active neutron interrogation has been applied to the measurement of spent research reactor (IRT) fuel assemblies. The advanced experimental fuel counter (AEFC) was used to compare the TCIF method with the typically used AmLi neutron interrogation source that emits neutrons that are random in time. The statistical uncertainty for the use of the random neutron source (AmLi) and the time correlated source ( 252 Cf) for spent fuel interrogations was evaluated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of Partially Observed Epidemics - Application to COVID-19

This report documents a statistical method for the "real-time" characterization of partially observed epidemics. Observations consist of daily counts of symptomatic patients, diagnosed with the disease. Characterization, in this context, refers to estimation of epidemiological parameters that can be used to provide short-term forecasts of the ongoing epidemic, as well as to provide gross information for the time-dependent infection rate. The characterization problem is formulated as a Bayesian inverse problem, and is predicated on a model for the distribution of the incubation period. The model parameters are estimated as distributions using a Markov Chain Monte Carlo (MCMC) method, thus quantifying the uncertainty in the estimates. The method is applied to the COVID-19 pandemic of 2020, using data at the country, provincial (e.g., states) and regional (e.g. county) levels. The epidemiological model includes a stochastic component due to uncertainties in the incubation period. This model-form uncertainty is accommodated by a pseudo-marginal Metropolis-Hastings MCMC sampler, which produces posterior distributions that reflect this uncertainty. We approximate the discrepancy between the data and the epidemiological model using Gaussian and negative binomial error models; the latter was motivated by the over-dispersed count data. For small daily counts we find the performance of the calibrated models to be similar for the two error models. For large daily counts the negative-binomial approximation is numerically unstable unlike the Gaussian error model. Application of the model at the country level (for the United States, Germany, Italy, etc.) generally provided accurate forecasts, as the data consisted of large counts which suppressed the day-to-day variations in the observations. Further, the bulk of the data is sourced over the duration before the relaxation of the curbs on population mixing, and is not confounded by any discernible country-wide second wave of infections. At the state-level, where reporting was poor or which evinced few infections (e.g., New Mexico), the variance in the data posed some, though not insurmountable, difficulties, and forecasts were able to capture the data with large uncertainty bounds. The method was found to be sufficiently sensitive to discern the flattening of the infection and epidemic curve due to shelter-in-place orders after around 90% quantile for the incubation distribution (about 10 days for COVID-19). The proposed model was also used at a regional level to compare the forecasts for the central and north-west regions of New Mexico. Modeling the data for these regions illustrated different disease spread dynamics captured by the model. While in the central region the daily counts peaked in the late April, in the north-west region the ramp-up continued for approximately three more weeks.

59 BASIC BIOLOGICAL SCIENCES↗

Total Measurement Uncertainty in Neutron Coincidence Multiplicity Analysis

Neutron multiplicity counting is the most commonly used nondestructive assay technique for determining the plutonium mass within containers of scrap PuO 2 or mixed oxide (MOX). In multiplicity analysis, the 240 Pu eff mass, leakage multiplication, and alpha ratio (the ratio of [α, n]-to-spontaneous fission neutron production) are the three primary unknown sample properties. They must be determined simultaneously. To solve for these three unknowns in a multiplicity assay, three measured values are needed: the singles, doubles, and triples neutron count rates. While the analysis is limited to solving for three unknowns, there are many additional factors that impact the observed count rates and contribute to the measurement uncertainty. In this study we investigate the various uncertainty contributors for the multiplicity analysis through a combination of traditional uncertainty propagation techniques supplemented by Monte Carlo simulations to address the dependences not explicitly expressed by the point source model. Uncertainties arising from counting statistics, calibration parameters, calibration method, nuclear data, and various material characteristics (isotopic abundances, chemical form, density, and impurities) are considered. A Total Measurement Uncertainty (TMU) estimate is then developed from these uncertainty contributors. This study is confined to multiplicity analysis of items commonly encountered in international safeguards applications. That is, the study focused on Pu oxides and MOX materials for the masses ranging up to 4000 grams total Pu. Multiplicity measurements were simulated using MCNP V6 based on the Plutonium Scrap Multiplicity Counter (PSMC), Epithermal Multiplicity Counter (ENMC), Pyrochemical Multiplicity Counter, and Large Epithermal Multiplicity Counter (LEMC) for this study; however, this report focuses on the parameterization of the uncertainties for the PSMC. The performance differences between the PSMC and the other multiplicity counting systems are relatively small, primarily manifesting in the impact on measurement precision so that the evaluation developed for the PSMC can be applied to the other multiplicity counting systems. Finally an analysis tool, the Multiplicity TMU Estimator, was developed from this study to serve as an aid for evaluation of the total measurement uncertainty of multiplicity assay results obtained from the commonly used INCC acquisition and analysis software.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Signature Analysis Utilizing a Dynamic Molten Salt Reactor Model for MC&A

Moving from traditional fixed fuel nuclear reactor systems to a mobile, dynamic fuel system that has dissolved special nuclear material in a molten salt is a paradigm shift in several respects. One major consideration is how to develop effective nuclear material controls and accounting for these novel reactor systems. The Molten Salt Reactor Experiment is one example of a critical molten salt system and provided a significant reference library based on the documented effort. But it was low thermal power that was not intended to reflect a commercial scale electricity production design. Therefore, to facilitate and assist vendors with domestic licensing considerations, research is underway to identify methods that could be used for domestic safeguards approaches for these novel reactor systems. This research presents the results of a signature analysis of data generated from three simulated scenarios using the molten salt demonstration reactor model defined in the Transient Simulation Framework of Reconfigurable Modules. Each scenario provides 1 hour isotope inventories over a 180 day period. The scenarios investigated provide test cases to examine if direct gamma-ray spectroscopy of the fuel can be used to identify changes comparing a base case (no reactivity control and fixed fission contribution) to an insertion of reactivity (10 pcm no change in fission composition) and a change in fission composition. The analysis demonstrates that monitoring the total count rate in a highly collimated high-resolution photon energy spectrum is sensitive to perturbations imposed into the reactor model. The total photon count rate changes ≈2% for the fission composition change and ≈4.5% for the reactivity insertion compared to the base case. However, both scenarios show an increase in the total photon count rate. The total photon count rate can be used to identify changes due to power (number of fissions) but not due to a change in the material undergoing fission. To distinguish between the two cases of increased power, the photon spectrum would require an intensive analysis technique. A photon peak count rate ratio analysis could be used to identify changes in the fissile material fission generation in the core through identification of a static peak that shows little variation to the source of fission and a highly varying peak. The photon peak strength will ultimately be determined by the isotope’s fission yield. A preliminary analysis investigating the coupling of the isotope’s fission yield and its concentration in the fuel salt derived from the modeling has been performed. A ratio analysis of the photon peak count rates of 140 La to 99 Mo demonstrated that the reactivity insertion creates a distinct difference in the ratio compared to the fission composition change scenario.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Northern Hemisphere Extratropical Cyclone Activity in the Twentieth Century Reanalysis Version 3 (20CRv3) and Its Relationship with Continental Extreme Temperatures

In this study, we detect and track extratropical cyclones using 6-hourly mean sea level pressure data taken from the Twentieth Century Reanalysis version 3 (20CRv3) over the period 1951–2015 and compare them with those in the Interim and fifth generation of ECMWF reanalyses over the period 1979–2018. Three indices were employed to characterize cyclone activity, including cyclone count, cyclone intensity, and a cyclone activity index (CAI) that combines the count and intensity. The results show that the cyclone indices in the three datasets have comparable annual climatologies and seasonal evolution over the northern extratropical land and ocean in recent decades. Based on the cyclone indices over the period 1951–2010 in 80 ensemble members of 20CRv3, cyclone count and intensity are negatively correlated in winter and tend to be positively and weakly correlated in summer. The interannual CAI variability is dominated by the cyclone count variability. Regional mean cyclone activity can be well represented using the ensemble average cyclone index. We then examined the linkage of the cyclone activity in 20CRv3 and observed cold and warm extremes over Eurasia and North America over the period 1951–2010. In winter, the principal components of interannual cold and warm extreme anomalies are more correlated with the regional mean cyclone count index over Eurasia, while they are more correlated with the cyclone intensity index over North America. The temperature anomalies associated with the regional and ensemble mean cyclone count index explain about 10% (20%) of interannual cold (warm) extreme variances averaged over Eurasia. The temperature anomalies associated with the mean cyclone intensity explain about 10% of interannual cold and warm extreme variances over North America. Large-scale atmospheric circulation anomalies in association with cyclone activity and the induced temperature advection drive temperature anomalies over Eurasia and North America. In summer, circulation and thermal advection anomalies associated with cyclone activity are weak over the two continents. Hence, that season’s relationship between cyclone activity and extreme temperature variability is weak.

20CRv3↗

Passive Neutron Instrumentation and Applications

This chapter presents a description of most of the instruments that are currently in use for the measurement of plutonium and uranium using passive methods (without an external source). This includes the acquisition electronics as well as Singles counting methods, coincidence counting methods and multiplicity counting methods. The Singles counting applications include the measurement of waste and curium bearing materials. The coincidence counting applications include bulk plutonium, bulk uranium, waste and holdup measurements and fresh fuel assemblies. The multiplicity application description includes advantages and disadvantages and multiplicity detector design. There is also a description of some non-3He systems. The chapter concludes with a description of additional concepts: neutron imagers, list-mode data analysis, distributed source term analysis, unattended monitoring and MCNP modeling for detector design.

Coincidence shift register↗

Laboratory testing methods to evaluate the reliability of occupancy sensors for commercial building applications

The energy performance of commercial buildings is greatly influenced by occupants which are highly variable and among the most unpredictable components of a building's operation. While most building control systems use fixed, predetermined occupancy schedules, these fixed occupancy levels can be quite different from actual occupancy. This can cause unnecessary energy consumption, particularly from heating, ventilation, and air conditioning (HVAC) and lighting systems which are responsible for approximately 60% of commercial buildings' energy use. The use of occupancy counting sensor systems integrated with building management system controls is one method that can be used to improve the energy-consuming performance of buildings. However, there is no standardized universal methodology and metrics to evaluate their reliability. The aim of this research is to develop a uniform evaluation methodology to assess the reliability of occupancy counting sensor systems in a controlled laboratory environment. The developed testing methodology includes both “typical” scenarios representing the occupancy scenarios of a typical commercial building, and “failure” testing scenarios which represent a range of potential scenarios that may impact a sensor system's reliability. These methods were then implemented in a case study to evaluate the performance of two novel occupancy counting sensor systems (i.e., door-centric, and camera-based). Results suggest that typical testing results can be used to compare the overall performance of the occupancy counting sensor systems; however, failure testing is also important to understand the weaknesses of the sensor system in order to select the suitable one for the intended use of the commercial building. In addition, the proposed methodology includes a modified confusion matrix which enables the ability to identify if failures are caused by over or under counting occupants and to what extent this occurs over the testing period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A new algorithm for estimating radioxenon concentrations

A new algorithm (Xcounts) is introduced for estimating the activity concentrations of the xenon isotopes 131m Xe, 133m Xe, 133 Xe, and 135 Xe using beta-gamma coincidence data. The algorithm simultaneously estimates the decay counts associated with the four xenon isotopes, background, and radon in contrast to the net-counts method that uses sequential residual removal to account for background and interreferences. Calibration data for background counts are determined from gas-background measurements and simulation. In Xcounts, the false positive count rates for 131m Xe and 133m Xe are lower than the false positive rates for 133 Xe and 135 Xe. This algorithm appears to reliably detect the metastable isotopes at lower activity levels than the net-counts method and have similar performance for the other isotopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applications of HPGe-detected high energy gamma rays toward quantifying neutron emission rates and 234 U enrichment in UF 6 cylinders

This study presents a 234 U enrichment meter that uses high energy gamma and neutron count rate as measured by a portable, high-purity germanium gamma ray detector. Twenty-one 30B cylinders containing UF 6 of varying origin were analyzed with an HPGe detector for high-energy gamma ray and neutron counts. Excellent correlations (R 2 0.95) between various regions of 3.0 MeV gamma rays, neutron count rate, and uranium enrichment were found. These neutron and high-energy gamma data are used to create calibration-dependent enrichment meters for 234 U. The 234 U enrichment calculated from the neutron count rate and 4 – 6 MeV gamma count rate is more accurate than methods that rely on the 120.9 keV peak which is strongly attenuated inside commercial sized UF 6 cylinders. These neutron and high-energy gamma enrichment calculators can also be used to determine a 235 U enrichment, assuming mass-based enrichment from natural uranium, but the results are not as accurate as the traditional 185.7 keV peak enrichment meter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the analysis of signal peaks in pulse-height spectra

The estimation of the signal location and intensity of a peak in a pulse height spectrum is important for X- ray and γ-ray spectroscopy, charged-particle spectrometry, liquid chromatography, and many other subfields. However, both the ‘‘centroid’’ and ‘‘signal intensity’’ of a peak in a pulse-height spectrum are ill-defined quantities and different methods of analysis will yield different numerical results. Here, we apply three methods of analysis. Method A is based on simple count summation and is likely the technique most frequently applied in practice. The analysis is straightforward and fast, and does not involve any statistical modeling. We find that it provides reliable results only for high signal-to-noise data, but has severe limitations in all other cases. Method B employs a Bayesian model to extract signal counts and centroid from the measured total and background counts. The resulting values are derived from the respective posteriors and, therefore, have a rigorous statistical meaning. The method makes no assumptions about the peak shape. It yields reliable and relatively small centroid uncertainties. However, it provides relatively large signal count uncertainties. Method C makes a strong assumption regarding the peak shape by fitting a Gaussian function to the data. Furthermore, the fit is based again on a Bayesian model. Although Method C requires careful consideration of the Gaussian width (usually given by the detector resolution) used in the fitting, it provides reliable values and relatively small uncertainties both for the signal counts and the centroid.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of ray-tracing simulations to confirm performance of the GP-SANS instrument at the High-Flux Isotope Reactor

The CG-2 beamline at the High Flux Isotope Reactor (HFIR) exhibits a notable discrepancy between observed count rates and the count rates we would expect based on a Monte-Carlo neutron ray-trace simulation. These simulations consistently predict count rates approximately five times greater than those observed in four separate experimental runs involving different instrument configurations. This discrepancy suggests that certain factors are causing losses in measurements that are not adequately accounted for in the simulation, in particular guide reflectivity or misalignment. To investigate these discrepancies, a high-dimensional simulation parameter approach is applied in order to understand the losses. Region of Interest (ROI) groups along the instrument are assigned to different surfaces of the guide components within the simulation. This allows the parameters of those guide components to be varied as a group to minimize the complexity of the search space. The result is an optimization of simulation parameters using an iterative scheme that aims to minimize the difference between experimentally measured count rates and simulated count rates across all tested collimator combinations. This proposed methodology holds the potential to reveal previously unrecognized sources of intensity loss in the CG-2 beamline at HFIR and improve the accuracy of simulations, leading to enhanced understanding and performance of the beamline for various scientific applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Waveform analysis of a large-area superconducting nanowire single photon detector

Superconducting nanowire single photon detectors (SNSPDs) are typically used as single-mode-fiber-coupled single-pixel detectors, but large area detectors are increasingly critical for applications ranging from microscopy to free-space quantum communications. However, the long meander-line length of such large-area SNSPDs results in a proportionately large kinetic inductance that affects the waveform generated by the device. Here, we explore changes in the rising edge of the readout pulse for a single-pixel large-area SNSPD as a function of the optical spot size on the detector and compare to the rising edge of the dark-count waveform. We observe a bimodal distribution of bright-count rise times and show that the probability of a slow rise time increases in the limit of large spot sizes, indicative of a position sensitive response. Additionally, in the limit of low bias currents, the dark-count readout pulse is most similar to the large spot-size bright-count readout pulse, which suggests that dark counts arise from locations spanning the device. Overall, these results are consistent with a simple model of traveling microwave modes excited by single photons incident at varying positions along the length of the nanowire.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of an autonomous acoustic surveying technique for grassland bird communities in Nebraska

Monitoring trends in wildlife communities is integral to making informed land management decisions and applying conservation strategies. Birds inhabit most niches in every environment and because of this they are widely accepted as an indicator species for environmental health. Traditionally, point counts are the common method to survey bird populations, however, passive acoustic monitoring approaches using autonomous recording units have been shown to be cost-effective alternatives to point count surveys. Advancements in automatic acoustic classification technologies, such as BirdNET, can aid in these efforts by quickly processing large volumes of acoustic recordings to identify bird species. While the utility of BirdNET has been demonstrated in several applications, there is little understanding of its effectiveness in surveying declining grassland birds. We conducted a study to evaluate the performance of BirdNET to survey grassland bird communities in Nebraska by comparing this automated approach to point count surveys. We deployed ten autonomous recording units from March through September 2022: five recorders in row-crop fields and five recorders in perennial grassland fields. During this study period, we visited each site three times to conduct point count surveys. We compared focal grassland bird species richness between point count surveys and the autonomous recording units at two different temporal scales and at six different confidence thresholds. Total species richness (focal and non-focal) for both methods was also compared at five different confidence thresholds using species accumulation curves. The results from this study demonstrate the usefulness of BirdNET at estimating long-term grassland bird species richness at default confidence scores, however, obtaining accurate abundance estimates for uncommon bird species may require validation with traditional methods.

59 BASIC BIOLOGICAL SCIENCES↗

LLNL measurements of thermally irradiated HEU sample and saltwater-matrixed HEU sample

Two scintillation vials, kindly provided by the PNNL team, were received in the LLNL radiochemistry building on June 10, 2024; one containing approximately 2 mL dissolved thermally-irradiated HEU, and the other containing dried salt from irradiated seawater. A quick, semiquantitative screening count of the salt showed that the activation product activities were very low, with the highest activity being ~1 Bq 24 Na. The dissolved HEU solution was transferred to a Prindle vial (LLNL standard counting geometry) and weighed. Approximately 2 mL 3 M HNO 3 was added so that the solution completely covered the bottom of the vial and Gamanal software would be able to accurately generate an efficiency curve. This sample, called “PNNLFP24” is the irradiated HEU solution received, gravimetrically diluted by a factor of 1.7356 ± 0.0003, and was sent for quick gamma counting prior to further modification. Meanwhile the salt was quantitatively transferred to a 250 mL polyethylene bottle and dissolved in 160 mL 3 M HNO 3 . After counting, 50 µL PNNLFP24 was aliquoted for Resonance Ionization Mass Spectrometry (RIMS) analysis, and then 10.0 mL of the salt solution (6.03% of the total salt, gravimetrically) was added to the remaining PNNLFP24 solution to make “PNNLFPSW24”. After weighing, two 100 µL aliquots were removed for RIMS and DES, and 3 mL was aliquoted for microfluidic chemistry. The remaining “PNNLFPSW24” solution was weighed and proceeded for singles and coincidence counting on the MCBOS system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improvements to the 115g/115m Cd Nuclear Data

Repeated measurements of the isotope 115m Cd by Los Alamos National Laboratory (LANL), Pacific Northwest National Laboratory (PNNL), and Atomic Weapons Establishment (AWE) have revealed a consistent discrepancy between beta and gamma counting. This suggests that a significant disparity exists between the true value of the isotope’s gamma-ray branching ratios and the values reported by the National Nuclear Data Center (NNDC). Enriched 114 Cd was irradiated using thermal neutrons to produce a high-purity 115m/g Cd source for counting and analysis using traditional singles gamma-ray spectroscopy, liquid scintillation counting, gas-proportional counting, and analysis using the new Gamma-Alpha-Beta-Gamma (GABγ) and Gamma-Alpha-Beta Radio-Isotope EvaLuator (GABRIEL) coincidence detection systems. Using the D-T fusion generated neutrons, reduces the wait time required to let the short-lived 115Cd ground state decay away by leveraging the 1:1 production ratio of the ground and metastable state of 115 Cd from the 115 In (n,p) reaction relative to the 10:1 production ratio of the ground and metastable isotopes of 115 Cd by thermal neutron capture on 114 Cd. However, the much higher flux in from the Washington State University TRIGA reactor is a more rapid method of production of 115m/gCd but requires access to enriched 114 Cd. High purity 115m/g Cd samples were analyzed on regular intervals over a period of 140-days. The activity of 115m Cd measured by beta and gamma show a clear discrepancy using the current best known gamma-ray decay branching ratios. Based on these observations and measurements, a set of new branching ratio recommendations have been produced using conventional counting techniques and the advanced GAB? and GABRIEL instruments.

07 ISOTOPE AND RADIATION SOURCES↗