Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Pressure measurement at low temperatures

The present discussion centers on the following topics: (1) what types of pressure transducers show good potential for cryogenic use; (2) what are the output characteristics (stability, sensitivity, etc.) of a transducer when subjected to low temperature environments; and (3) are methods or apparatus available to calibrate cryogenically pressure transducers under static and dynamic conditions. Some information is available on the low-temperature performance of relatively few pressure transducer types; however, the information is either in the form of manufacturing specifications or unpublished reports. The results of this study clearly indicate that individual transducers, even from the same manufacturer, can exhibit totally different characteristics when subjected to identical cryogenic test procedures. This indicates the necessity of calibrating each transducer for use at low temperature. Also included in the discussion is the description of a static/dynamic low-temperature pressure transducer calibration facility, which is currently being developed.

Arvidson, J. M.↗

Real-gas effects 1: Simulation of ideal gas flow by cryogenic nitrogen and other selected gases

The thermodynamic properties of nitrogen gas do not thermodynamically approximate an ideal, diatomic gas at cryogenic temperatures. Choice of a suitable equation of state to model its behavior is discussed and the equation of Beattie and Bridgeman is selected as best meeting the needs for cryogenic wind tunnel use. The real gas behavior of nitrogen gas is compared to an ideal, diatomic gas for the following flow processes: isentropic expansion; normal shocks; boundary layers; and shock wave boundary layer interactions. The only differences in predicted pressure ratio between nitrogen and an ideal gas that may limit the minimum operating temperatures of transonic cryogenic wind tunnels seem to occur at total pressures approaching 9atmospheres and total temperatures 10 K below the corresponding saturation temperature, where the differences approach 1 percent for both isentropic expansions and normal shocks. Several alternative cryogenic test gases - air, helium, and hydrogen - are also analyzed. Differences in air from an ideal, diatomic gas are similar in magnitude to those of nitrogen. Differences for helium and hydrogen are over an order of magnitude greater than those for nitrogen or air. Helium and hydrogen do not approximate the compressible flow of an ideal, diatomic gas.

Hall, R. M.↗

Alignment and evaluation of the cryogenic corrected infrared astronomical satellite /IRAS/ telescope

Room temperature alignment and evaluation techniques for the Infrared Astronomical Satellite (IRAS) telescope, which has a primary mirror figured to correct for surface distortions and the 2 K operating temperature are discussed. Interferometric cryogenic testing of the 0.6 m, f/1.5 lightweighted beryllium primary mirror at its intended operating temperature reveals surface distortions that can be modeled with Zernike polynomials. With this model, it becomes possible to derive the 'inverse' of the cryowavefront error (ideal cryo mirror) and to figure the cryo correction into the primary mirror using Perkin-Elmer's Computer Controlled Polisher. It is recognized that during room temperature assembly of the system, misalignment of the secondary mirror can introduce additional unwanted aberrations that may cancel or distort the wavefront errors purposely introduced by the cryo figuring. To avoid this possible degradation and to ensure optimum telescope performance, the system Zernike polynomial coefficients and wavefront maps generated from the in-process alignment interferograms are monitored and compared to Zernike coefficients and wavefront maps for the cryo corrected primary mirror.

Harned, N.↗

Multiplexed extrinsic silicon detector array

Multiplexed extrinsic silicon detector arrays for infrared applications were developed and tested. Cryogenic electronics are discussed. Ambient temperature electronics are also discussed.

Yee, J. F.↗

Bearings working group

The service life of the Space Shuttle Main Engine (SSME) turbomachinery bearings was a predominant factor in engine durability and maintenance problems. Recent data has indicated that bearing life is about one order of magnitude lower than the goal of seven and one-half hours particularly those in the High Pressure Oxidizer Turbopump (HPOTP). Bearing technology, primarily cryogenic turbomachinery bearing technology, is expanded by exploring the life and performance effects of design changes; design concept changes; materials changes; manufacturing technique changes; and lubrication system changes. Each variation is assessed against the current bearing design in full scale cryogenic tests.

Source record↗

Development of lightweight, glass mirror segments for the Large Deployable Reflector

Accomplishments in the development of lightweight, honeycomb-core, sandwich mirror blanks made of borosilicate and high-silica glasses at the University of Arizona for the Large Deployable Reflector program are described. In this paper, work spanning the last 2 years is reported, highlighting a new mirror blank fabrication technique that permits the fabrication of the honeycomb core integrally with the front and back plates of the blank in a single furnace cycle. Two types of mirror blanks made by this method, an off-axis, aspheric segment and a smaller Vycor circular piece, are described. The fabrication of two off-axis, aspheric mirror segments is also described. Cryogenic test results are included on the test of a 38-cm diameter, lightweight, honeycomb core, sandwich mirror made of Pyrex.

Melugin, R. K.↗

Diffuse Infrared Background Experiment (DIRBE) optics module breadboard alignment methods and results

The Diffuse Infrared Background Experiment (DIRBE) optics module will be assembled at ambient temperature but will operate at liquid helium temperature. The challenging task of ensuring that is possible to maintain alignment through cryogenic cooling and cryogenic vibration has been demonstrated in a DIRBE optics module breadboard program. This paper discusses the configuration of the DIRBE optics module breadboard, ambient temperature optical alignment methods used to assemble the breadboard, and cryogenic testing of the breadboard. The alignment of the optical assembly at ambient temperature, at 77 K, and after a 77 K vibration was within specification.

Magner, Thomas J.↗

Microwave characterization of high-temperature superconducting thin films using stripline resonators

A method was derived for the extraction of the surface resistivity (Rs) of high-Tc superconducting (HTS) thin films at microwave frequencies, using a stripline resonator circuit. Surface resistivity values were calculated by measuring the difference in Q-values of a stripline resonator configuration when an HTS thin film was substituted for one of the metallic ground planes. Cryogenic tests were completed for several stripline resonator structures, yielding accurate predictions of the HTS thin-film performance at frequencies between 3 and 26 GHz (in harmonics of approximately 3 GHz). These results were then used to illustrate the dependence of HTS surface resistivity on frequency and temperature in the microwave frequency band.

Macdonald, Alan D.↗

IAL SPACE: A test laboratory for the ISO cryogenic payload

The ESA Infrared Space Observatory (ISO) satellite is a 3 axes pointed platform designed to make accurate pointed observations of astronomical objects and sources in the wavelength range between 2.5 and 200 microns. ISO is composed of a service module and a payload module which is a large cylindrical vacuum vessel. The vessel is in fact a cryostat (capacity of 2250 l of liquid He II) which contains the telescope and the four focal scientific instruments. The latter being cooled up to a temperature less than 4 K. The qualification of the payload requires the measurement respectively of: the image quality of the telescope through wave front error (WFE) measurements; and the optical alignment of the scientific instruments with respect to the telescope axis and the telescope focus, and this under cryogenic conditions. Consequently, since 1988, the FOCAL 5 IAL Space facility has been upgraded in order to perform the cryogenic optical tests of the ISO optical subsystems.

Cucchiaro, A.↗

A temperature and pressure controlled calibration system for pressure sensors

A data acquisition and experiment control system capable of simulating temperatures from -184 to +220 C and pressures either absolute or differential from 0 to 344.74 kPa is developed to characterize silicon pressure sensor response to temperature and pressure. System software is described that includes sensor data acquisition, algorithms for numerically derived thermal offset and sensitivity correction, and operation of the environmental chamber and pressure standard. This system is shown to be capable of computer interfaced cryogenic testing to within 1 C and 34.47 Pa of single channel or multiplexed arrays of silicon pressure sensors.

Chapman, John J.↗

Observatories in earth orbit and beyond

The present volume on observations in earth orbit and beyond discusses current and future missions, launch vehicles, the relative merits of various observatories, and long-term future issues. Attention is given to the Granat automatic spacecraft, the prospects of the Hipparcos mission, EUV and FUV astronomy from Voyagers 1 and 2, and the X-ray Timing Explorer. Topics addressed include the SAX mission for X-ray astronomy, the Space Infrared Telescope Facility, the Ulysses mission in the high-latitude heliosphere, and science operations for future space astrophysics missions. Also discussed are science observations with the IUE using the one-gyro mode, new methods of determining spacecraft attitude, cryogenic testing of optics for ISOCAM, and the stellar X-ray polarimeter for the Spectrum-X-Gamma mission.

Kondo, Yoji↗

Advances in LO2 Propellant Conditioning

This paper describes the cryogenic testing and analysis that has recently been completed as part of a multi-year effort to develop a new, more robust and operable LO2 propellant conditioning system. Phase 1 of the program consisted of feasibility demonstrations ot four novel propellant conditioning concepts. A no-bleed, passive propellant conditioning option was shown for the first time to successfully provide desired propellant inlet conditions. The benefits of passive conditioning are reduced operations costs, decreased hardware costs, enhanced operability and increased reliability on future expendable launch vehicles In Phase 2 of the test program, effects of major design parameters were studied and design correlation for future vehicle design were developed. Simultaneously, analytical models were developed and validated. Over 100 tests were conducted with a full-scale feedline using LN2 as the test fluid. A circulation pump provided a range of pressure and flow conditions. The test results showed that the passive propellant conditioning system is insensitive to variations in many of the parameters. The test program provides the validation necessary to incorporate the passive conditioning system into the baseline of future vehicles. Modeling of these systems using computational fluid dynamics seems highly promising.

Mehta, Gopal↗

Maintaining Flatness of a Large Aperture Potassium Bromide Beamsplitter Through Mounting and Vibration

The Composite Infrared Spectrometer (CIRS) instrument on the Cassini Mission launched in October of 1997. The CIRS instrument contains a mid-infrared (MIR) and a far-infrared interferometer (FIR) and operates at 170 Kelvin. The MIR is a Michelson Fourier transform spectrometer utilizing a 76 mm (3 inch) diameter potassium bromide beamsplitter and compensator pair. The potassium bromide elements were tested to verify effects of cooldown and vibration prior to integration into the instrument. The instrument was then aligned at ambient temperatures, tested cryogenically and re-verified after vibration. 'Me stringent design optical figure requirements for the beamsplitter and compensator included fabrication errors, mounting stresses and vibration load effects. This paper describes the challenges encountered in mounting the elements to minimize distortion and to survive vibration.

Losch, Patricia↗

Maintaining Flatness of a Large Aperture Potassium Bromide Beamsplitter through Mounting and Vibration

The Composite Infrared Spectrometer (CIRS) instrument on the Cassini Mission launched in October of 1997. The CIRS instrument contains a mid-infrared and a far-infrared interferometer and operates at 170 Kelvin. The mid-infrared interferometer is a Michelson- type Fourier transform spectrometer utilizing a 3 inch diameter potassium bromide beamsplitter/compensator pair. The potassium bromide elements were tested to verify effects of cooldown and vibration prior to integration into the instrument. The instrument was then aligned at ambient temperatures, tested cryogenically and re-verified after vibration. The stringent design optical figure requirements for the beamsplitter and compensator included fabrication errors, mounting stresses and vibration load effects. This paper describes the challenges encountered in mounting the elements to minimize distortion and to survive vibration.

Losch, Patricia↗

Joined Beryllium Mirror Demonstrator

Fabrications of large Beryllium optical components are fundamentally limited by available facility capabilities. To overcome this limitation, NASA funded Brush Wellman Corp to study a Be joining process. Four 76 mm diameters samples and a 0.5 mm diameter Joined Beryllium Mirror Demonstrator (JBMD) were fabricated. This presentation will review the fabrication of these samples and summarize the results of their cryogenic testing at MSFCs XRCF.

Stahl, H. Philip↗

Aerogel Beads as Cryogenic Thermal Insulation System

An investigation of the use of aerogel beads as thermal insulation for cryogenic applications was conducted at the Cryogenics Test Laboratory of NASA Kennedy Space Center. Steady-state liquid nitrogen boiloff methods were used to characterize the thermal performance of aerogel beads in comparison with conventional insulation products such as perlite powder and multilayer insulation (MLI). Aerogel beads produced by Cabot Corporation have a bulk density below 100 kilograms per cubic meter (kg/cubic m) and a mean particle diameter of 1 millimeter (mm). The apparent thermal conductivity values of the bulk material have been determined under steady-state conditions at boundary temperatures of approximately 293 and 77 kelvin (K) and at various cold vacuum pressures (CVP). Vacuum levels ranged from 10(exp -5) torr to 760 torr. All test articles were made in a cylindrical configuration with a typical insulation thickness of 25 mm. Temperature profiles through the thickness of the test specimens were also measured. The results showed the performance of the aerogel beads was significantly better than the conventional materials in both soft-vacuum (1 to 10 torr) and no-vacuum (760 torr) ranges. Opacified aerogel beads performed better than perlite powder under high-vacuum conditions. Further studies for material optimization and system application are in progress.

Fesmire, J. E.↗

Thermal Insulation Performance of Flexible Piping for Use in HTS Power Cables

High-temperature superconducting (HTS) cables that typically operate at temperatures below 80 K are being developed for power transmission. The practical application of HTS power cables will require the use of flexible piping to contain the cable and the liquid nitrogen coolant. A study of thermal performance of multilayer insulation (MLI) was conducted in geometries representing both rigid and flexible piping. This experimental study performed at the Cryogenics Test Laboratory of NASA Kennedy Space Center provides a framework for the development of cost-effective, efficient thermal insulation systems that will support these long-distance flexible lines containing HTS power cables. The overall thermal performance of the insulation system for a rigid configuration and for a flexible configuration, simulating a flexible HTS power cable, was determined by the steady-state liquid nitrogen boiloff method under the full range of vacuum levels. Two different cylindrically rolled material systems were tested: a standard MLI and a layered composite insulation (LCI). Comparisons of ideal MLI, MLI on rigid piping, and MLI between flexible piping are presented.

Fesmire, James E.↗

SLMS(Trademark) Athermal Technology for UV and Cryogenic Applications

SLMS (Trademark) Technology with an areal density of 5-10 kg/square meter has demonstrated exceptional figure accuracy (as low as 0.005 waves rms HeNe) and surface finish (less than 3 Angstroms rms) for Ultraviolet and Extreme Ultraviolet Imaging Applications, with dimensional stability of approx. 6 nm rms from 300 K to 27 K for Cryogenic Tests performed at NASA MSFC XRCF. This talk describes results of Phase I and Phase II SBIR work for both NASA and the Air Force.

Goodman, William A.↗