Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryostat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

268 records · Page 15

Integrated Refrigeration and Storage of LNG for Compositional Stability

Growing interest in liquefied natural gas (LNG) as a rocket fuel necessitates a greater technical understanding of the compositional changes due to preferential boil-off (or weathering) that occurs during long duration storage. The purity of methane in LNG can range from 90 to 98%, and is subject to preferential boil-off due to its low boiling point compared to other constituents despite the use of high-performance thermal insulation systems. Active heat extraction (i.e. refrigeration) is required to completely eliminate weathering. For future operational safety and reliability, and to better understand the quality and efficiency of the LNG as a cryofuel, a 400-liter Cryostat vessel was designed and constructed to measure the composition and temperatures of the LNG at a number of different liquid levels over long durations. The vessel is the centerpiece of a custom-designed lab-scale integrated refrigeration and storage (IRaS) system employing a pulse tube cryocooler capable of roughly 50 W of lift at 100 K. Instrumentation includes ten temperature sensors mounted on a vertical rake and five liquid sample tubes corresponding to five liquid levels. Two modes of operation are studied. The first is without refrigeration in order to determine a baseline in the change in composition, and to study stratification of the LNG. The second is performed with the cryocooler active to determine the operational parameters of the IRaS system for eliminating the weathering as well as stratification effects in the bulk liquid. The apparatus design and test method, as well as preliminary test results are presented in this paper. As a bonus in cost-saving and operational efficiency, the capability of the IRaS system to provide zero-loss capabilities such as zero boil-off (ZBO) keeping of the LNG and zero-loss filling/transfer operations are also discussed.

Rose, L.↗

Lynx X-Ray Microcalorimeter Cryogenic System

The Lynx x-ray microcalorimeter instrument on the Lynx X-ray Observatory requires a state-of-the-art cryogenic system to enable high-precision and high-resolution x-ray spectroscopy. The cryogenic system and components described provide the required environment using cooling technologies that are already at relatively high technology readiness levels and are progressing toward flight-compatible subsystems. These subsystems comprise a cryostat, a 4.5-K mechanical cryocooler, and an adiabatic demagnetization refrigerator that provides substantial cooling power at 50 mK.

DiPirro, Michael↗

Novel Fiber Optic Sensing Arrays with Enhanced Sensitivity in Cryogenic Temperatures

State-of-the-art instrumentation techniques have provided an opportunity to obtain greater insight into the characteristics of cryogenic liquid storage. Optical fiber sensors that utilize fiber Bragg gratings are a viable option for temperature sensing in volatile liquid such as liquid oxygen because there is no risk of electrical sparking and no electromagnetic interference. The National Aeronautics and Space Administration (NASA) Armstrong Flight Research Center (Edwards, California) has developed a novel, simple-to-fabricate fiber array sensor that has been tested and found to be three times more sensitive than typical fiber sensors under cryogenic condition (traditional fiber sensors can suffer from reduced sensitivity below 100 K). Cryogenic temperature monitoring using the NASA fiber optic sensing system is demonstrated in a simulated cryostatic condition, as well as in an elevated pressure environment under liquid nitrogen. Measurement accuracy is compared with traditional silicon diodes. Instrument installation, sensor characteristics, and experimental results are discussed in detail.

Hon Man Chan↗

Parallel Plate Capacitor Aluminum KIDs for Future Far-Infrared Space-Based Observatories

Future space-based far-infrared astrophysical observatories will require exquisitely sensitive detectors consistent with the low optical backgrounds. The PRobe far-Infrared Mission for Astrophysics (PRIMA) will deploy arrays of thousands of superconducting kinetic inductance detectors (KIDs) sensitive to radiation between 25 and 265 μm. Here, we present laboratory characterization of prototype, 25 – 80 μm wavelength, low-volume, aluminum KIDs designed for the low-background environment expected with PRIMA. A compact parallel plate capacitor is used to minimize the detector footprint and suppress TLS noise. A novel resonant absorber is designed to enhance response in the band of interest. We present noise and optical efficiency measurements of these detectors taken with a low background cryostat and a cryogenic blackbody. A microlens-hybridized KID array is found to be photon noise limited down to about 50 aW with a limiting detector NEP of about 6.5×10 −19 W/Hz 1/2 . A fit to an NEP model shows that our optical system is well characterized and understood down to 50 aW. We discuss future plans for low-volume aluminum KID array development as well as the testbeds used for these measurements.

Far-Infrared↗

Thermal Performance of Common Bulk-Fill Cryogenic Insulation Materials in Helium and Hydrogen Background Gases

Maritime shipping of vast quantities of liquid hydrogen (LH 2 ) will be necessary to facilitate a global hydrogen ecosystem; with some studies estimating volumes up to 172,000 m 3 for individual tanker ships, and requiring stationary storage tanks at terminals of 50,000 m 3 to 100,000 m 3 —ten to fifteen times larger than the current largest tank, located at launch pad B at NASA Kennedy Space Center (KSC). Such a radical scale-up will push the boundary of traditional, vacuum-insulated tank designs. Hence, a potential need exists for non-vacuum solutions, which necessitates exploring the thermal performance of insulation materials in non-condensable background gasses at LH 2 temperatures, namely helium and hydrogen. Testing of two bulk-fill insulation materials common to large LH 2 storage tanks, perlite and glass bubbles, in helium and hydrogen was recently conducted by the Cryogenics Test Laboratory at KSC using the Cryostat-100 liquid nitrogen boiloff calorimeter per the ASTM C1774 standard methodology. Effective thermal conductivity (k e ) and heat flux (q) results for each insulation/gas combination are presented across the full vacuum range, as well as thermal profiles through the insulation thickness between 78 K and 293 K.

A M Swanger↗

Results from Tests of the Fast Alternative Cryogenic Experiment Testbed

To address the gap in manifest opportunities for low temperature microgravity payloads that has accompanied the start of the build era for the International Space Station (ISS), development of a new facility compatible with one or more carriers in the baseline shuttle manifest has been undertaken.

Fundamental Physics Shuttle Payload Cryostat↗

(abstract) Simple Spreadsheet Thermal Models for Cryogenic Applications

Self consistent circuit analog thermal models, that can be run in commercial spreadsheet programs on personal computers, have been created to calculate the cooldown and steady state performance of cryogen cooled Dewars. The models include temperature dependent conduction and radiation effects. The outputs of the models provide temperature distribution and Dewar performance information. These models have been used to analyze the Cryogenic Telescope Test Facility (CTTF). The facility will be on line in early 1995 for its first user, the Infrared Telescope Technology Testbed (ITTT), for the Space Infrared Telescope Facility (SIRTF) at JPL. The model algorithm as well as a comparison of the model predictions and actual performance of this facility will be presented.

cryogenic thermal model cryostat SIRTF↗

Thermal Design and Analysis of Cooling SOFIA HIRMES to 4K Cryogenic Temperature Using Cryocooler

HIgh Resolution Mid-infrarEd Spectrometer (HIRMES) is a facility-class instrument aboard the Stratospheric Observatory for Infrared Astronomy (SOFIA) Aircraft Observatory. A TransMIT PTD 406C pulse tube cryocooler (PTC) is used to cool the optical bench and optical components to 4K. A second PTC is dedicated to cool the 3He/4He sorption cooler. The first stages of the PTCs share the heat load from the intermediate temperature stage. The second stage of the first PTC removes nearly all the heat load from the 4 degrees Kelvin stage. The results of thermal analysis show that the 4 degrees Kelvin stage of the HIRMES thermal subsystem meets all of its requirements using the 100 percent heat load margin approach and conservative modeling assumptions.

Cryostat↗

The Fast Alternative Cryogenic Experiment Testbed

Subsystems for a proof of concept cryogenic payload have been developed to demonstrate the ability to accommodate low temperature science investigations within the constraints of the Hitchhiker siderail carrier on the Space Shuttle.

space↗