Search NASA⌕ Search

SEARCH · Search NASA

Results for “data sheet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Nuclear Structure and Decay Data for A=167 Isobars

Experimental nuclear spectroscopic data are compiled and evaluated for 17 known nuclides of mass 167 (Sm, Eu, Gd, Tb, Dy, Ho, Er Tm, Yb, Lu, Hf, Ta, W, Re, Os, Ir, Pt), 23 years after the previous full evaluation by 2000Ba65. Detailed information is presented for each reaction and decay experiment. Combining all the available data, recommended values are provided for energies, spins and parities, and half-lives of levels, with energies, branching ratios and multipolarities of γ radiations, and characteristics of β and α radiations in radioactive decays. Here, the α decays of A=171 nuclei to A=167 daughters are included in this work, while for α decays of A=167 nuclei to A=163 daughters, consult Nuclear Data Sheets (2010Re03) or the ENSDF database for A=163. 167 Er, 167 Tm, 167 Yb, 167 Lu and 167 Ta are among the most extensively studied nuclides via decay and high-spin gamma-ray spectroscopy measurements, followed by 167 Ho, 167 Hf, 167 W, and 167 Os. Information for excited states in 167 Dy, 167 Re, and 167 Ir are limited; no excited states have yet been identified in 167 Sm, 167 Eu, 167 Gd, 167 Tb and 167 Pt, with the ground-state half-life of 167 Sm remaining unknown. This work supersedes the earlier evaluation of A=167 nuclei by 2000Ba65.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recommended Nuclear Structure and Decay Data for A = 200 Isobars

Evaluated nuclear structure and decay data for all nuclei with mass number A = 200 ( 200 Os, 200 Ir, 200 Pt, 200 Au, 200 Hg, 200 Tl, 200 Pb, 200 Bi, 200 Po, 200 At, 200 Rn, and 200 Fr), are presented. All available experimental data are compiled and evaluated, and best values for level and gamma-ray energies, quantum numbers, lifetimes, gamma-ray intensities and transition probabilities, as well as other nuclear properties, are recommended. Inconsistencies and discrepancies that exist in the literature are discussed. A number of computer codes (https://www-nds.iaea.org/public/ensdf pgm/) developed by members of the NSDD network were used during the evaluation process. In conclusion, this work supersedes the earlier evaluation by F.G. Kondev and S. Lalkovski (2007Ko42), published in Nuclear Data Sheets 108, 1471 (2007).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recommended Nuclear Structure and Decay Data for A=206 Isobars

Here, evaluated nuclear structure and decay data for all nuclei with mass number A=206 ( 206 Pt, 206 Au, 206 Hg, 206 Tl, 206 Pb, 206 Bi, 206 Po, 206 At, 206 Rn, 206 Fr, 206 Ra and 206 Ac), are presented. All available experimental data are compiled and evaluated, and best values for level and γ-ray energies, quantum numbers, lifetimes, γ-ray intensities and transition probabilities, as well as other nuclear properties, are recommended. Inconsistencies and discrepancies that exist in the literature are discussed. A number of computer codes (https://www-nds.iaea.org/public/ensdf_pgm/) developed by members of the NSDD network were used during the evaluation process. This work supersedes the earlier evaluation by F.G. Kondev (2008Ko21), published in Nuclear Data Sheets 109, 1527 (2008).

Kondev, F. G. [Argonne National Laboratory (ANL), ↗

Nuclear Structure and Decay Data for A=175 Isobars

In this article , nuclear structure data for 15 known nuclides of mass number 175 (Dy, Ho, Er, Tm, Yb, Lu, Hf, Ta, W, Re, Os, Ir, Pt, Au, Hg) have been evaluated, which supersedes the earlier work done by M. Shamsuzzoha Basunia (2004Ba89), published in Nuclear Data Sheets 102, 719 (2004).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Temperature Coefficients of Perovskite Photovoltaics for Energy Yield Calculations

Temperature coefficients for maximum power (TPCE), open circuit voltage (VOC), and short circuit current (JSC) are standard specifications included in data sheets for any commercially available photovoltaic module. To date, there has been little work on determining the TPCE for perovskite photovoltaics (PV). We fabricate perovskite solar cells with a TPCE of -0.08 rel %/°C and then disentangle the temperature-dependent effects of the perovskite absorber, contact layers, and interfaces by comparing different device architectures and using drift-diffusion modeling. A main factor contributing to the small TPCE of perovskites is their low intrinsic carrier concentrations with respect to Si and GaAs, which can be explained by its wider band gap. In this work, we demonstrate that the unique increase in Eg with increasing temperatures seen for perovskites results in a reduction in JSC but positively influences VOC. The current limiting factors for the TPCE in perovskite PV are identified to originate from interfacial effects.

14 SOLAR ENERGY↗

Arduino based radiation survey meter

This paper presents the design of new digital radiation survey meter with LND7121 Geiger Muller tube detector and Atmega328P microcontroller. Development of the survey meter prototype is carried out on Arduino Uno platform. 16-bit Timer1 on the microcontroller is utilized as external pulse counter to produce count per second or CPS measurement. Conversion from CPS to dose rate technique is also performed by Arduino to display results in micro Sievert per hour (μSvhr{sup −1}). Conversion factor (CF) value for conversion of CPM to μSvhr{sup −1} determined from manufacturer data sheet is compared with CF obtained from calibration procedure. The survey meter measurement results are found to be linear for dose rates below 3500 µSv/hr.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Half-life of {sup 66}Ga

We measured the half-life of {sup 66}Ga by observing positrons from the {beta}{sup +} branch to the ground state of {sup 66}Zn with a superconducting Wu-type beta spectrometer. Our result is t{sub 1/2}=9.304(8)hours, which is the highest-precision measurement to date and disagrees with the Nuclear Data Sheets (NDS) value by over 6{sigma}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Q Value of {sup 115}In->{sup 115}Sn(3/2{sup +}): The Lowest Known Energy beta Decay

Using precision, cryogenic, Penning-trap mass spectrometry we have measured the atomic mass difference M[{sup 115}In]-M[{sup 115}Sn] to be 497.489(10) keV/c{sup 2}. Combined with the energy of the 3/2{sup +} first excited state of {sup 115}Sn[J. Blachot, Nuclear Data Sheets 104, 967 (2005)], the Q value of the {sup 115}In(9/2{sup +})->{sup 115}Sn(3/2{sup +}) beta decay is determined to be 155(24) eV. This confirms the inference of Cattadori et al.[Nucl. Phys. A 748, 333 (2005)] that this small branching-ratio beta decay has the lowest-known Q value. We also report improved values of the individual atomic masses: M[{sup 115}In]=114.903 878 774(16) u and M[{sup 115}Sn]=114.903 344 697(17) u.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coupled Induction Machine and HVAC Models for Simulating HVAC Performance Considering Grid Dynamics in Buildings

This paper presents the development of novel models that integrate induction machines with HVAC equipment, such as pumps, heat pumps, and chillers, to analyze the impact of electrical parameters on the operational performance of thermo-fluid systems. The proposed model employs a coupling technique that captures the dynamic interactions between induction machines and HVAC systems. By integrating electrical, thermal, and mechanical dynamics, the models provide a comprehensive framework for simulating real-world scenarios, including interactions with the electrical grid. This achievement was made possible through the development of a Computationally Efficient and Accurate Induction Machine (CEAIM) model. Implemented using the equation-based Modelica language, the CEAIM model has been validated against experimental results, manufacturer data sheets, and various operating conditions. Its performance has been compared with existing induction machine models in the Modelica Standard Library (MSL), demonstrating superior accuracy and computational efficiency. The CEAIM model predicts torque, speed, and power consumption with a coefficient of determination (R 2 ) ranging from 0.98 to 1 and a coefficient of variation of root mean square error (CVRMSE) between 0.27% and 6.67%. Additionally, CEAIM scales more efficiently than conventional MSL models, with a slower computational growth rate in large-scale simulations. After thorough validation of the CEAIM model, it was coupled with HVAC equipment as this approach provides a detailed multi-dimensional view of capturing electrical transients and mechanical performance. To support this, a case study was conducted to showcase its capabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental and Monte Carlo studies of fluence corrections for graphite calorimetry in low- and high-energy clinical proton beams

Purpose: The aim of this study was to determine fluence corrections necessary to convert absorbed dose to graphite, measured by graphite calorimetry, to absorbed dose to water. Fluence corrections were obtained from experiments and Monte Carlo simulations in low- and high-energy proton beams. Methods: Fluence corrections were calculated to account for the difference in fluence between water and graphite at equivalent depths. Measurements were performed with narrow proton beams. Plane-parallel-plate ionization chambers with a large collecting area compared to the beam diameter were used to intercept the whole beam. High- and low-energy proton beams were provided by a scanning and double scattering delivery system, respectively. A mathematical formalism was established to relate fluence corrections derived from Monte Carlo simulations, using the FLUKA code [A. Ferrari et al., “FLUKA: A multi-particle transport code,” in CERN 2005-10, INFN/TC 05/11, SLAC-R-773 (2005) and T. T. Böhlen et al., “The FLUKA Code: Developments and challenges for high energy and medical applications,” Nucl. Data Sheets 120, 211–214 (2014)], to partial fluence corrections measured experimentally. Results: A good agreement was found between the partial fluence corrections derived by Monte Carlo simulations and those determined experimentally. For a high-energy beam of 180 MeV, the fluence corrections from Monte Carlo simulations were found to increase from 0.99 to 1.04 with depth. In the case of a low-energy beam of 60 MeV, the magnitude of fluence corrections was approximately 0.99 at all depths when calculated in the sensitive area of the chamber used in the experiments. Fluence correction calculations were also performed for a larger area and found to increase from 0.99 at the surface to 1.01 at greater depths. Conclusions: Fluence corrections obtained experimentally are partial fluence corrections because they account for differences in the primary and part of the secondary particle fluence. A correction factor, F(d), has been established to relate fluence corrections defined theoretically to partial fluence corrections derived experimentally. The findings presented here are also relevant to water and tissue-equivalent-plastic materials given their carbon content.

60 APPLIED LIFE SCIENCES↗

Patch-level chamber-based CH4 and CO2 flux measurements in freshwater and salt marshes of coastal Louisiana

This dataset contains chamber-based carbon dioxide and methane flux measurements from ecohydrological patches in two coastal wetlands in Louisiana (within the footprint of AmeriFlux sites US-LA2 and US-LA3). Measurements span four patches, two per wetland. At the freshwater marsh (US-LA2), patches were dominated by Sagittaria lancifolia or co-dominated by Sagittaria lancifolia and Typha latifolia. At the salt marsh site (US-LA3), patches were dominated by Spartina alterniflora or Juncus roemerianus. Flux measurements included (i) wetland surface-level measurements encompassing the entire soil-water-vegetation column and (ii) soil-water surface chamber measurements that excluded emergent vegetation. At US-LA3, open-water pools were common and were also measured as a patch type. With this data we aimed to assess differences in gas flux pathways within ecohydrological patches across different wetland types. Files can be read in any program or code typical of processing .csv file types. "PatchChambers_LA2LA3.csv" covers flux data from patch level chambers which includes bulk CO2/CH4 flux encompassing water, soil, and vegetation within each chamber. "Water_Soil_SurfaceChamber_LA2LA3.csv" has CO2/CH4 flux data from chambers measuring only the water-soil surface without the effects of vegetation. Metadata can be found in the similarly named files for each data sheet ("xxxx_md.csv").

54 ENVIRONMENTAL SCIENCES↗

Sandia National Laboratories, California Chemical Management Program Annual Report

The annual program report provides detailed information about all aspects of the Sandia National Laboratories, California (SNL/CA) Chemical Management Program. It functions as supporting documentation to the SNL/CA Environmental Management System Program Manual. This program annual report describes the activities undertaken during the calender past year, and activities planned in future years to implement the Chemical Management Program, one of six programs that supports environmental management at SNL/CA. SNL/CA is responsible for tracking chemicals (chemical and biological materials), providing Material Safety Data Sheets (MSDS) and for regulatory compliance reporting according to a variety of chemical regulations. The principal regulations for chemical tracking are the Emergency Planning Community Right-to-Know Act (EPCRA) and the California Right-to-Know regulations. The regulations, the Hazard Communication/Lab Standard of the Occupational Safety and Health Administration (OSHA) are also key to the CM Program. The CM Program is also responsible for supporting chemical safety and information requirements for a variety of Integrated Enabling Services (IMS) programs primarily the Industrial Hygiene, Waste Management, Fire Protection, Air Quality, Emergency Management, Environmental Monitoring and Pollution Prevention programs. The principal program tool is the Chemical Information System (CIS). The system contains two key elements: the MSDS library and the chemical container-tracking database that is readily accessible to all Members of the Sandia Workforce. The primary goal of the CM Program is to ensure safe and effective chemical management at Sandia/CA. This is done by efficiently collecting and managing chemical information for our customers who include Line, regulators, DOE and ES and H programs to ensure compliance with regulations and to streamline customer business processes that require chemical information.

54 ENVIRONMENTAL SCIENCES↗

Commercialization of New Lattice-Matched Multi-Junction Solar Cells Based on Dilute Nitrides: July 8, 2010 - March 7, 2012

All the milestones for this program were achieved and in most cases, particularly those related to cell performance, more samples were supplied than was required, and the deliverables substantially exceed the performance milestones. Moreover, the cell deliverables sent to NREL for evaluation were cells 4 mm or 5.5 mm, nearly 5 to 10 times larger in area than the 2 mm cells called for in the subcontract, and one of the most common sizes in the CPV industry. For the entire program there were 12 separate cell performance milestones, the most important of which was the 3J cell efficiency. Phase 1 had 2 3J efficiency milestones and Phase 2 had three. For the Phase 1 milestone calling for 38% efficiency, NREL measured a peak efficiency of 41.1%, about 2% higher than the data sheet values of commercial cells at that time. The efficiencies measured in Phase 1 exceed the Phase 2 cell performance milestones in the subcontract’s original Statement of Work. Cells submitted to NREL as part of this subcontract, although not as deliverables, were measured to have a new World Record cell efficiency of 43.5%, breaking the previous World Record by 1.2% absolute. In addition to improved cell performance, during Phase 1 a modeling capability for designing ARCs was developed and verified by comparing the measured current from a cell using a specific ARC with the current predicted by the model. This model was then used to design a new ARC giving lower reflectivity and a corresponding higher cell current. Again the prediction of the model was verified by measured cell properties. In Phase 2, the modeling capability was used to design a glass matched ARC, the type most in use in the CPV industry, which was tuned to the band structure of a 3J cell with a dilute nitride bottom cell. Finally, tools and test methodologies were developed that enable HALT to be applied to cells to determine the operating and destruct limits and to determine or set bounds on the lifetime of the cells in typical CPV operating conditions. As part of this effort a novel HALT system was built that enabled cells to be subjected to light at concentrations up to 80 W/cm 2 , (800 suns) while the cell temperature could be held or cycled between -100C and +180C. As part of the Phase 2 effort the system was modified to enable the light to the cell to be interrupted at a maximum rate of 10 times/second. Tests using interrupted light at >500 suns on cells held at 180C showed no evidence of failure after a total of >22 sun-years of operation at 100C. Another key outcome of the reliability efforts of the program was from high temperature storage tests done independently of the HALT test. There were two key outcomes of this activity: 1) single junction GaInNAs cells showed no evidence of failure under the equivalent of at least 100 years of on-sun time operating at 100C and 2) we can conclude with 95% confidence that the probability of device failure after 30 sun-years of operation at 100C is less than 1.5%, and mostly less than 0.5%. Based on these results there is no reason to believe that dilute nitrides in and of themselves pose a reliability problem for CPV applications and that 3J cells using dilute nitrides have very low probability of failure during the expected 20-30 year life of a CPV power plant.

14 SOLAR ENERGY↗

Preliminary Evaluation of Removing Used Nuclear Fuel from Shutdown Sites

This report presents a preliminary evaluation of removing used nuclear fuel (UNF) from 12 shutdown nuclear power plant sites. At these shutdown sites the nuclear power reactors have been permanently shut down and the sites have been decommissioned or are undergoing decommissioning. The shutdown sites are Maine Yankee, Yankee Rowe, Connecticut Yankee, Humboldt Bay, Big Rock Point, Rancho Seco, Trojan, La Crosse, Zion, Crystal River, Kewaunee, and San Onofre. The evaluation was divided into four components: characterization of the UNF and greater-than-Class C low-level radioactive waste (GTCC waste) inventory; a description of the on-site infrastructure and conditions relevant to transportation of UNF and GTCC waste; an evaluation of the near-site transportation infrastructure and experience relevant to shipping transportation casks containing UNF and GTCC waste, including identification of gaps in information; and, an evaluation of the actions necessary to prepare for and remove UNF and GTCC waste. The primary sources for the inventory of UNF and GTCC waste are the U.S. Department of Energy (DOE) RW-859 used nuclear fuel inventory database, industry sources such as StoreFUEL and SpentFUEL, and government sources such as the U.S. Nuclear Regulatory Commission. The primary sources for information on the conditions of site and near-site transportation infrastructure and experience included observations and information collected during visits to the Maine Yankee, Yankee Rowe, Connecticut Yankee, Humboldt Bay, Big Rock Point, Rancho Seco, Trojan, La Crosse, and Zion sites; information provided by managers at the shutdown sites; Facility Interface Data Sheets compiled for DOE in 2005; Services Planning Documents prepared for DOE in 1993 and 1994; industry publications such as Radwaste Solutions; and Google Earth. State and Regional Group representatives, a Tribal representative, and a Federal Railroad Administration representative participated in six of the shutdown site visits. Every site was found to have at least one off-site transportation mode option for removing its UNF and GTCC waste; some have multiple options. Experience removing large components during reactor decommissioning provided an important source of information used to identify the transportation mode options for the sites. Especially important in conducting the evaluation were site visits, through which information was obtained that would not have been available otherwise. Extensive photographs taken during the site visits proved to be particularly useful in documenting the current conditions at or near the sites. Additional conclusions from this evaluation include: The 12 shutdown sites use designs from 4 different suppliers involving 9 different (horizontal and vertical) dry storage systems that would require the use of 8 different transportation cask designs to remove the UNF and GTCC waste from the shutdown sites; Although there are common aspects, each site has some unique features and/or conditions; Although some regulatory actions will be required, all UNF at the initial 9 shutdown sites (Maine Yankee, Yankee Rowe, Connecticut Yankee, Humboldt Bay, Big Rock Point, Rancho Seco, Trojan, La Crosse, and Zion) is in licensed systems that can be transported, including a small amount of high-burnup fuel; Each site indicated that 2-3 years of advance time would be required for its preparations before shipments could begin; Most sites have more than one transportation option, e.g., rail, barge, or heavy haul truck, as well as constraints and preferences. It is expected that additional site visits will be conducted to add to the information presented in the evaluation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary Evaluation of Removing Used Nuclear Fuel from Shutdown Sites

A preliminary evaluation of removing spent nuclear fuel (SNF) from 13 shutdown nuclear power plant sites was performed. At these shutdown sites the nuclear power reactors have been permanently shut down and the sites have been decommissioned or are undergoing decommissioning. The shutdown sites were Maine Yankee, Yankee Rowe, Connecticut Yankee, Humboldt Bay, Big Rock Point, Rancho Seco, Trojan, La Crosse, Zion, Crystal River, Kewaunee, San Onofre, and Vermont Yankee. The evaluation was divided into four components: Characterization of the SNF and greater-than-Class C low-level radioactive waste (GTCC waste) inventory A description of the on-site infrastructure at the shutdown sites An evaluation of the near-site transportation infrastructure and transportation experience at the shutdown sites An evaluation of the actions necessary to prepare for and remove SNF and GTCC waste. The primary sources for the inventory of SNF and GTCC waste were the U.S. Department of Energy (DOE) spent nuclear fuel inventory database, industry publications such as StoreFUEL, and government sources such as the U.S. Nuclear Regulatory Commission. The primary sources for information on the conditions of on-site infrastructure and near-site transportation infrastructure and experience included information collected during site visits, information provided by managers at the shutdown sites, Facility Interface Data Sheets compiled for DOE in 2005, Services Planning Documents prepared for DOE in 1993 and 1994, industry publications such as Radwaste Solutions, and Google Earth. State staff, State Regional Group representatives, a Tribal representative, and a Federal Railroad Administration representative have participated in nine of the shutdown site visits. Every shutdown site was found to have at least one off-site transportation mode option for removing its SNF and GTCC waste; some have multiple options. Experience removing large components during reactor decommissioning provided an important source of information used to identify the transportation mode options for the sites. Especially important in conducting the evaluation were site visits, through which information was obtained that would not have been available otherwise. Extensive photographs taken during the site visits proved to be particularly useful in documenting the current conditions at or near the sites. Additional conclusions from this evaluation include: The 13 shutdown sites use designs from 4 different suppliers involving 11 different (horizontal and vertical) dry storage systems that would require the use of 9 different transportation cask designs to remove the SNF and GTCC waste from the shutdown sites. Although some changes to transportation certificates of compliance will be required, the SNF at the initial 9 shutdown sites (Maine Yankee, Yankee Rowe, Connecticut Yankee, Humboldt Bay, Big Rock Point, Rancho Seco, Trojan, La Crosse, and Zion) is in dual purpose dry storage canisters that can be transported, including a small amount of high-burnup fuel. Most sites indicated that 2-3 years of advance time would be required for its preparations before shipments could begin. Some sites could be ready in less time. As additional sites such as Fort Calhoun, Clinton, Quad Cities, Pilgrim, Oyster Creek, and Diablo Canyon shut down, these sites will be included in updates to the evaluation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cure Schedule for Stycast 2651/Catalyst 11.

The Henkel technical data sheet (TDS) for Stycast 2651/Catalyst 11 lists three alternate cure schedules for the material, each of which would result in a different state of reaction and different material properties. Here, a cure schedule that attains full reaction of the material is defined. The use of this cure schedule will eliminate variance in material properties due to changes in the cure state of the material, and the cure schedule will serve as the method to make material prior to characterizing properties. The following recommendation was motivated by (1) a desire to cure at a single temperature for ease of manufacture and (2) a desire to keep the cure temperature low (to minimize residual stress build-up associated with the cooldown from the cure temperature to room temperature) without excessively limiting the cure reaction due to vitrification (i.e., material glass transition temperature, T g , exceeding cure temperature).

36 MATERIALS SCIENCE↗

Cure Schedule for Stycast 2651/Catalyst 9.

The Emerson & Cuming technical data sheet (TDS) for Stycast 2651/Catalyst 9 lists three alternate cure schedules for the material, each of which would result in a different state of reaction and different material properties. Here, a cure schedule that attains full reaction of the material is defined. The use of this cure schedule will eliminate variance in material properties due to changes in the cure state of the material, and the cure schedule will serve as the method to make material prior to characterizing properties. The following recommendation uses one of the schedules within the TDS and adds a “post cure” to obtain full reaction.

36 MATERIALS SCIENCE↗

Document Release of CSAM 99-140 to DNFSB for Review, October 17, 2018

The data sheet on HFE-7200 from 3M is included in attachment 2. Unfortunately, at this time, the Criticality Safety Group cannot allow the replacement of TCE by HFE-7200 for the reasons discussed below. The moderating and reflecting properties of HFE-7200 were compared to trichloroethylene (TCE) and water. The results of several calculations are presented in attachment 1 and indicate that water is a far superior moderator than either HFE-7200 or TCE, but HFE-7200 results in significantly higher reactivity than TCE. The criticality safety evaluation for machining (CSM1020) credited the usage of TCE and this material was included in the Monte Carlo calculations to determine the reactivity of the upset conditions. Unfortunately, since the results of these calculations are relatively high, it cannot be determined without significant re-evaluation whether the replacement of conservatisms were employed in CSM1020 to simplify the calculations, it is likely that a re-evaluation considering less conservative models would allow the approval of HFE-7200. The Criticality Safety Group will include HFE-7200 when the evaluation for machining is upgraded to higher mass limits (with shape control).

61 RADIATION PROTECTION AND DOSIMETRY↗