Search NASA⌕ Search

SEARCH · Search NASA

Results for “degradation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Interpreting accelerated tests on perovskite modules using photooxidation of MAPbI 3 as an example

Solar panels (modules) based on metal halide perovskites are following a fast track to commercialization. Unlike more established solar cell materials, there are not yet decades-long field observations to increase consumer confidence. The "physics and chemistry of failure" approach is used in other industries and estimates product degradation based on laboratory accelerated tests integrated with an understanding of degradation mechanisms. This work uses that approach to quantify the relationship between accelerated tests and projected product behavior for metal halide perovskite modules. Degradation involving photooxidation of methylammonium lead iodide is used to illustrate the method. Acceleration factors in common accelerated tests are found to be low. Conclusions emphasize that the accelerated tests on photovoltaics should not be interpreted as equivalent across module types or as a green light for commercialization unless supported by the appropriate field data or physics and chemistry of failure analysis.

14 SOLAR ENERGY↗

Hydrogen Peroxide-Water-Ethanol Monopropellant Blend for CubeSat Propulsion

Monopropellant propulsion that provides high performance and low hazards compared to state-of-art hydrazine are being investigated under NASA, DOD and commercially sponsored green propellant research and development programs. This NASA effort looks at phosphate stabilized 50% hydrogen peroxide/water –ethanol blends to evaluate their stability and combustion behavior in submillimeter diameter microtube combustion apparatus for cubesat propulsion applications. Exploratory 7-day stability tests find no pressure rise in a sealed test tube environment at room temperature indicating at least short term stability of the mixture. Temperature rise during combustion testing in resistively heated nickel microtube apparatus shows that micro-combustion is achieved in the tube. Propellant density is approximately 1.2 g/cu.cm compared to 1.0 g/cu.cm for hydrazine. Theoretical specific impulse of the stoichiometric blend is 219 s at a chamber pressure of 20 psia and an area ratio of 30:1. Density-specific impulse of this blend is 263 s while hydrazine is only about 215-220 s in small reaction control system thrusters. This provides about 20-22% more density-specific impulse for the cube sat compared to hydrazine. The the oretical combustion temperature is 2168°F, which is thermally compatible with stainless steel materials of construction and the nickel catalyst used in the tests. Combustion test results are given for stoichiometric, as well as fuel-lean and fuel-rich propellant formulations. These tests focus on thermally and catalytically supported combustion in the microtube, which requires a microtube preheat temperature of about 900°F and sufficient residence time to achieve combustion that is stable and anchored in the tube without blowing through the tube unreacted. Thrust class is expected to be in the 10 m N range based on flow rate and estimated specific impulse. Power requirements are generally below 25 W to heat the tube. Steady state combustion testing is typically conducted for 3 minutes and shows little degradation of the hardware over multiple test cycles indicating that there is little catalyst degradation over time and little catalyst deactivation due to the phosphate stabilizer in the hydrogen peroxide.

Monopropellant↗

Detecting Coastal Wetland Degradation by Combining Remote Sensing and Hydrologic Modeling

Sea-level rise and climate change stresses pose increasing threats to coastal wetlands that are vital to wildlife habitats, carbon sequestration, water supply, and other ecosystem services with global significance. However, existing studies are limited in individual sites, and large-scale mapping of coastal wetland degradation patterns over a long period is rare. Our study developed a new framework to detect spatial and temporal patterns of coastal wetland degradation by analyzing fine-scale, long-term remotely sensed Normalized Difference Vegetation Index (NDVI) data. Then, this framework was tested to track the degradation of coastal wetlands at the Alligator River National Wildlife Refuge (ARNWR) in North Carolina, United States, during the period from 1995 to 2019. We identified six types of coastal wetland degradation in the study area. Most of the detected degradation was located within 2 km from the shoreline and occurred in the past five years. Further, we used a state-of-the-art coastal hydrologic model, PIHM-Wetland, to investigate key hydrologic processes/variables that control the coastal wetland degradation. The temporal and spatial distributions of simulated coastal flooding and saltwater intrusion confirmed the location and timing of wetland degradation detected by remote sensing. The combined method also quantified the possible critical thresholds of water tables for wetland degradation. The remote sensing–hydrologic model integrated scheme proposed in this study provides a new tool for detecting and understanding coastal wetland degradation mechanisms. Our study approach can also be extended to other coastal wetland regions to understand how climate change and sea-level rise impact wetland transformations.

54 ENVIRONMENTAL SCIENCES↗

An Accelerated Life Testing Dataset for Lithium-Ion Batteries With Constant and Variable Loading Conditions

The dataset repository is organized into three main folders, each containing one group of life cycled battery packs. Within each folder individual battery packs own their dedicated csv file for continuous data logging, which are named with their respective battery pack number. The folders are named: - regular_alt_batteries: Containing one csv file for each battery pack cycled at the same load level or load range throughout lifetime - recommissioned_batteries: Containing one csv file for each battery pack cycled at different load levels at varying life stages - second_life_batteries: Containing one csv file for each second life battery pack cycled at constant current througout the second life

Li-ion Battery↗

Experimental investigation and model development of the Skylab ATM secondary nickel-cadmium batteries

The performance of a Ni-Cd battery was evaluated and the cyclic battery controls to be used on the ATM batteries were determined. Cell and battery performance models were developed which to predict the performance of the secondary Ni-Cd batteries on the ATM. Capacity degradation and charge acceptance characteristics were considered. Mathematical models for each of these operating areas were developed based on data from two separate test programs. The capacity degradation model describes the expected usable battery capacity as a function of time, temperature, and depth-of-discharge. The charge acceptance model describes the cell charge acceptance as a function of charge rate, temperature, and state of charge. The models were designed for computer use and to facilitate possible battery modification. They can be used to predict expected performance or to compare real time performance during flight.

Kirsch, W. W.↗

Long life testing of spare Mariner Venus '67 hardware

The faultless performance of the Mariner Venus '67 Power Conditioning Electronics (PCE) throughout six years of continuous operation in a simulated space environment is reported. Weekly functional tests supplemented by daily monitoring verified that the PCE equipment can perform to its intended functions for at least six years without apparent performance degradation. Performance throughout the test period was very stable, there are no circuit or redundancy improvements to be considered. When the equipment was examined after the test was completed, there was no evidence of any physical damage nor any difficulty in disconnecting the wiring connectors.

Silverman, S. W.↗

Dynamic Capability of an Operating Stirling Convertor

The NASA John H. Glenn Research Center and the US Department of Energy are currently developing a Stirling convertor for use as an advanced spacecraft power system for future NASA deep-space missions. NASA Headquarters has recently identified the Stirling technology generator for potential use as the spacecraft power system for two of NASA's new missions, the Europa Orbiter and the Solar Probe missions (planned for launch in 2006 and 2007 respectively). As part of the development of this power system, a Stirling Technology Demonstration Convertor was vibration tested at NASA John H. Glenn Research Center to verify its survivability and capability of withstanding the harsh dynamic environment typically seen by the spacecraft when it is launched by an expendable launch vehicle. The Technology Demonstration Convertor was fully operational (producing power) during the random vibration testing. The output power of the convertor and other convertor performance indicators were measured during the testing, and these results are discussed in this paper. Numerous accelerometers and force gauges also were used to provide information on the dynamic characteristics of the Technology Demonstration Convertor and as an indication of any possible damage due to the vibration. These measurements will also be discussed in this paper. The vibration testing of the Stirling Technology Demonstration Convertor was extremely successful. The Technology Demonstration Convertor survived all its vibration testing with no structural damage or functional performance degradation. As a result of this testing, the Stirling convertor's capability to withstand vibration has been demonstrated, enabling its usage in future spacecraft power systems.

Goodnight, Thomas W.↗

Vibration Testing of an Operating Stirling Convertor

The NASA John H. Glenn Research Center and the U.S. Department of Energy are currently developing a Stirling convertor for use as an advanced spacecraft power system for future NASA deep-space missions. As part of this development, a Stirling Technology Demonstrator Convertor (TDC) was recently tested to verify its survivability and capability of withstanding its expected launch random vibration environment. The TDC was fully operational (producing power) during the random vibration testing. The output power of the convertor was measured during the testing, and these results are discussed in this paper. Numerous accelerometers and force gauges were also present which provided information on the dynamic characteristics of the TDC and an indication of any possible damage due to vibration. These measurements will also be discussed in this paper. The vibration testing of the Stirling TDC was extremely successful. The TDC survived all its vibration testing with no structural damage or functional performance degradation. As a result of this testing, the Stirling convertor's capability to withstand vibration has been demonstrated, enabling its usage in future spacecraft power systems.

Hughes, William O.↗

Purging of a tank-mounted multilayer insulation system by gas diffusion

The investigation was conducted on a multilayer insulation (MLI) system mounted on a spherical liquid hydrogen propellant tank. The MLI consisted of two blankets of insulation each containing 15 double-aluminized Mylar radiation shields separated by double silk net spacers. The gaseous nitrogen initially contained within the MLI system and vacuum chamber was purged with gaseous helium introduced both underneath the MLI and into the vacuum chamber. The MLI panels were assumed to be purged primarily by means of gas diffusion. Overall, test results indicated that nitrogen concentrations well below 1 percent could be achieved everywhere within the MLI system. Typical times to achieve 1 percent nitrogen concentration within the MLI panels ranged from 69 minutes at the top of the tank to 158 minutes at the bottom of the tank. Four space-hold thermal performance tests indicated no significant thermal degradation of the MLI system had occurred due to the purge tests conducted. The final measured heat input attributed to the MLI was 7.23 watts as compared to 7.18 watts for the initial baseline thermal performance test.

Sumner, I. E.↗

Effects of hydraulic fluid CVCM on silver-Teflon

Changes in the solar absorptance of silver-Teflon (Ag/FEP) surfaces were measured after contamination by the outgassing products of hydraulic fluid and irradiation by solar simulators. Although radiator surfaces are selected for stability to the solar ultraviolet and particulate environment, contaminant deposition and their interaction with solar exposure can degrade their performance. The test procedure to deposit the hydraulic fluid collected volatile condensible material (CVCM), irradiate, and determine solar absorptance changes by reflectance measurements using a spectrophotometer and a solar simulator is described. The tests showed that for the estimated deposition rates on the Ag/FEP, the hydraulic fluid CVCM fraction remaining under normal conditions (above -40 C) would not degrade its performance. The residual CVCM can be easily removed from Ag/FEP by wiping with a solvent saturated flannel. The changes in solar absorptance with the CVCM film thickness and the radiation exposure duration are reported, concluding that vacuum ultraviolet radiation did not prevent easy removal of CVCM.

Muscari, J. A.↗

Three Year Aging of Prototype Flight Laser at 10 Khz and 1 Ns Pulses with External Frequency Doubler for the Icesat-2 Mission

We present the results of three year life-aging of a specially designed prototype flight source laser operating at 1064 nm, 10 kHz, 1ns, 15W average power and external frequency doubler. The Fibertek-designed, slightly pressurized air, enclosed-container source laser operated at 1064 nm in active Q-switching mode. The external frequency doubler was set in a clean room at a normal air pressure. The goal of the experiment was to measure degradation modes at 1064 and 532 nm discreetly. The external frequency doubler consisted of a Lithium triborate, LiB3O5, crystal operated at non-critical phase-matching. Due to 1064 nm diagnostic needs, the amount of fundamental frequency power available for doubling was 13.7W. The power generated at 532 nm was between 8.5W and 10W, depending on the level of stress and degradation. The life-aging consisted of double stress-step operation for doubler crystal, at 0.35 J/cm2 for almost 1 year, corresponding to normal conditions, and then at 0.93 J/cm2 for the rest of the experiment, corresponding to accelerated testing. We observed no degradation at the first step and linear degradation at the second step. The linear degradation at the second stress-step was related to doubler crystal output surface changes and linked to laser-assisted contamination. We discuss degradation model and estimate the expected lifetime for the flight laser at 532 nm. This work was done within the laser testing for NASA's Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) LIDAR at Goddard Space Flight Center in Greenbelt, MD with the goal of 1 trillion shots lifetime.

Frequency Doubling↗

Three Three-Year Aging of Prototype Flight Laser at 10 kHz and 1 ns Pulses With External Frequency Doubler for ICESat-2 Mission

We present the results of three year life-aging of a specially designed prototype flight source laser operating at 1064 nm, 10 kHz, 1ns, 15W average power and external frequency doubler. The Fibertek-designed, slightly pressurized air, enclosed-container source laser operated at 1064 nm in active Q-switching mode. The external frequency doubler was set in a clean room at a normal air pressure. The goal of the experiment was to measure degradation modes at 1064 and 532 nm discreetly. The external frequency doubler consisted of a Lithium triborate, LiB3O5, crystal operated at non-critical phase-matching. Due to 1064 nm diagnostic needs, the amount of fundamental frequency power available for doubling was 13.7W. The power generated at 532 nm was between 8.5W and 10W, depending on the level of stress and degradation. The life-aging consisted of double stress-step operation for doubler crystal, at 0.35 Jcm2 for almost 1 year, corresponding to normal conditions, and then at 0.93 Jcm2 for the rest of the experiment, corresponding to accelerated testing. We observed no degradation at the first step and linear degradation at the second step. The linear degradation at the second stress-step was related to doubler crystal output surface changes and linked to laser-assisted contamination. We discuss degradation model and estimate the expected lifetime for the flight laser at 532 nm. This work was done within the laser testing for NASAs Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) LIDAR at Goddard Space Flight Center in Greenbelt, MD with the goal of 1 trillion shots lifetime.

Lidar↗

Characterization and Accelerated Life Testing of a New Solid Oxide Electrolysis Cell

The project aims to develop mechanistic degradation models that realistically predict long-term Solid Oxide Electrolysis Cell (SOEC) durability, using input data from accelerated electrochemical life testing combined with quantitative microstructural and microchemical evaluation. A promising SOEC type will be further developed. The understanding achieved by combining experimental results and theory will be used to guide improvements in long-term SOEC durability, and validate that this technology can reach DOE H 2 production cost and durability targets. Planned outcomes include: (1) new experimental accelerated testing data on SOEC degradation at the oxygen electrode, fuel electrode, and electrolyte; (2) predictive theory of degradation developed based on the accelerated test data; (3) new electrode materials and processing methods that minimize degradation rate; (4) determination of the impact of SOEC electrolyte thickness and electrode composition/microstructure on performance and degradation; (5) determination of the operating conditions where degradation is minimized; and (6) validation of degradation models for extrapolating accelerated test data to predict long-term durability.

08 HYDROGEN↗

Space Shuttle Body Flap Actuator Bearing Testing For NASA Return to Flight

The Space Shuttle body flap is located beneath the main engine nozzles and is required for proper aerodynamic control during orbital descent. Routine inspection of one of four body flap actuatols found one of the actuator bearings had degraded and blackened balls. A test program was initiated to demonstrate that it is acceptable to operate bearings which are degraded from operation over several flights. This test exposed the bearing to predicted flight axial loads, speeds and temperatures. Testing has been completed, and results indicate the previously flown bearings are acceptable for up to 12 additional missions.

Jett, Timothy R.↗

Space Shuttle Body Flap Actuator Bearing Testing for NASA Return to Flight

The Space Shuttle body flap is located beneath the main engine nozzles and is required for proper aerodynamic control during orbital descent. Routine inspection of one of four body flap actuators found one of the actuator bearings had degraded and blackened balls. A test program was initiated to demonstrate that it is acceptable to operate bearings which are degraded from operation over several flights. This test exposed the bearing to predicted flight axial loads, speeds and temperatures. Testing at 140 F has been completed, and results indicate the previously flown bearings are acceptable for up to 12 additional missions. Additional testing is underway to determine the lubricant life at various temperatures and stresses and to further understand the mechanism that caused the blacken balls. Initial results of this testing indicates that bearing life is shorten at room temperature possibly due fact that higher temperature (140 F) accelerates the flow of grease and oil into the wear surface

Jett, Timothy R.↗

Hubble Space Telescope Degradation Data Used for Ground-Based Durability Projection of Insulation on the International Space Station

Ground-based environmental durability tests have indicated that exposing materials in accelerated tests to known spacecraft mission degradation sources predicted by an environmental model does not simulate the extent of damage that occurs in the space environment. The reasons for this may include the complex nature of the space environment, which is not simulated completely in any ground-based facility, the extreme differences in exposure rates in space and in ground tests, and inaccuracies in environmental models. One approach to overcoming the difficulties in simulating the space environment using ground-based testing is to calibrate the facility using data from actual space-exposed materials to determine exposure levels required to replicate degraded properties observed in space. Research was conducted at the NASA Glenn Research Center to develop a ground-to-space correlation method that determines the durability of Teflon-based insulation for the International Space Station (ISS) by using data obtained in a ground facility and degraded Teflon thermal insulation retrieved from the Hubble Space Telescope.

deGroh, Kim K.↗