Search NASA⌕ Search

SEARCH · Search NASA

Results for “degradation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Pathways to IEC Standards for Heliostat Design Qualification and Site Acceptance in Central Receiver CSP Applications

This paper surveys the existing landscape of standards relevant to heliostats, identifies their gaps, and proposes a path forward to a comprehensive set of heliostat guidelines, technical specifications, and standards under the framework of International Electrotechnical Commission (IEC) TC 117. Gaps in existing guidelines and standards are surveyed using a three-tiered taxonomy: component-level, heliostat-level, and field-level. At each level, the gap analysis is followed by a proposal for a coordinated path forward on the development of standards. At the component level, advances in the understanding of wind loading should inform a technical specification for drives and structures. Reflectors require consolidation of measurement guidelines into existing standards documents. Communications & controls require technical standards to inform their selection and secure implementation. At the heliostat level, IEC 62817 (solar trackers) adequately characterizes drive systems, structures, and electronics, but requires adaptation to heliostats' use patterns, operating modes, and expected life cycles. IEC 62817 does not address heliostat beam quality and pointing accuracy, but the process for determining both is elaborated in the SolarPACES Guideline for Heliostat Performance Testing. This SolarPACES document requires two main modifications: adaptation to IEC language and inclusion of testing after heliostats which have undergone accelerated weathering and mechanical cycling (to understand performance degradation). At the field level, IEC 62862-4-2 addresses the function and control of heliostat fields but does not cover the statistically rigorous testing of heliostat groups, or field performance factors like security and soiling. The addition of documents under IEC-62862-4 is proposed to address this gap.

beam↗

Environmental Degradation in Advanced Reactor Environments

The Advanced Materials and Manufacturing Technologies (AMMT) program operating under the Department of Energy Office of Nuclear Energy is accelerating the qualification and deployment of additively manufactured materials in advanced reactor environments. Laser powder bed fusion (LPBF) has emerged as a promising additive manufacturing technique to fabricate complex components with the potential of tailored material properties. In the nuclear industry, metal additive manufacturing can offer numerous advantages, such as reduced lead times, streamlined quality assurance, and cost-effective low-volume production of new and replacement components with conventional or novel materials and geometries. The rapid and effective qualification of the effect of processing variability on the performance and degradation of additively manufactured materials is essential for the deployment of these components into advanced reactor environments. This talk presents an overview of the Environmental Effects area activities within AMMT. AMMT is performing irradiation and corrosion testing of several materials built by LPBF, including 316L and 316H stainless steels. Our irradiation efforts encompass neutron irradiation testing and ion irradiation testing to provide a robust technical basis for understanding the effect of process variability on materials degradation. We develop focused irradiation test plans that align well with risk-informed and technologically inclusive approaches to licensing. We will also discuss our plans and specific concerns for corrosion testing additively manufactured material, with a primary focus on molten salt and liquid sodium environments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Foam Degradation Model during Thermal Hypothetical Accident Conditions

Current practice in Safety Analysis Report for Packaging (SARP) thermal analysis for hypothetical accident conditions (HAC) of packages is to not explicitly model the consequence to the foam impact limiting material, but instead to make conservative estimates of those consequences and begin calculations from that point. This approach is typically used for the foam regression distance, which is the thickness of the degraded foam layer after the 30-minute fire event. Estimates for regression distance can come directly from package burn test results or from correlations based on one-dimensional testing by the foam manufacturer. In either case, this is a subjective process, and although it can be used to produce a conservative result, it is a significant approximation in the analysis. This paper describes testing and refinement of a simplified foam regression model. Comparisons are made against available data from laboratory experiments. Model refinements were tested until satisfactory agreement was achieved. The final modeling approach was then compared with post-test inspection results from HAC burn test data. A new model with an effective thermal conductivity based on foam to char density variation was shown successful in representing laboratory-scale foam thermal degradation experiments and full-scale burn tests of a current package. This model offers a technically defensible and predictive approach for modeling thermal degradation of rigid polyurethane insulation in transport packages.

36 MATERIALS SCIENCE↗

Reactor Pressure Vessel Fracture Mechanics Development and Concrete Application Testing for Grizzly

The Grizzly code is being developed to address degradation issues in nuclear reactor structures and components. For light-water reactors, Grizzly currently has capabilities to simulate degradation processes and their effects on structural integrity in two key areas: reactor pressure vessels (RPVs) and reinforced concrete structures. This report documents improvements made to Grizzly’s ability to address both of these structural systems. For RPVs, the reduced-order models (ROMs) used in fracture mechanics calculations have been expanded to allow their application over a broader range of the parameter space than was permitted by the previous models. The ROMs currently used in Grizzly for the evaluation of flaws that are fully embedded within the RPV (as opposed to surface-breaking flaws) are based on a model that is known to be conservative, indicating higher stress intensity factors than would be obtained from direct simulations. A more accurate model that eliminates these excess conservatisms has been recently included in the American Society of Mechanical Engineers Boiler and Pressure Vessel Code but was not applicable for flaws near the RPV surface, which is where the most critical flaws are usually located. That model has recently been extended for increased applicability in this near-surface region. The ROMs for embedded flaws in the Grizzly code have been expanded to include these recent extensions, which permit their use in a much broader set of cases than previously possible. Direct 3D simulations have been used to check these ROMs and have shown good agreement in most cases, although there are still some cases that need further investigation. There are considerable benefits to using these these more accurate and less conservative ROMs for embedded flaws. On a benchmark probabilistic fracture mechanics problem tested here, the conditional probability of fracture initiation computed for a population of flaws in a single plate in an RPV decreased by over a factor of 3. To address aging in reinforced concrete structures, a capability to simulate multiple degradation mechanisms, including alkali-silica reaction and radiation-induced volumetric expansion has been developed in Grizzly over the past several years. This had previously been demonstrated on laboratory-scale specimens but not on full-scale nuclear concrete structures with reinforcement. To demonstrate the applicability of Grizzly to the analysis of large-scale structures of interest, a full 3D model of a representative reinforced concrete structure, including a complex arrangement of reinforcing bars, was developed and demonstrated in Grizzly.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Potential induced degradation in c-Si glass-glass modules after extended damp heat stress

Traditional Glass-Backsheet (GB) photovoltaic (PV) modules have been the industry standard for a long time, but the Glass-Glass (GG) modules are quickly rising in popularity. PV modules installed in hot-humid climates with high string voltages can undergo potential induced degradation (PID). So far, to the best of our knowledge, only fresh modules with strong interfacial adhesion have been investigated for PID. However, in reality, the PV modules have weak interfacial adhesion after a few years of field exposure. Therefore, it is essential to evaluate PV modules with weakened interfaces. In this study, we investigated the PID susceptibility of PV modules with weakened interfaces after subjecting them to 2000 hours of damp heat (DH2000) at 85°C/85% relative humidity (RH) in an accelerated environmental chamber. Fresh GG modules were also stressed for PID to compare with PID degradation of DH-stressed modules. Pre- and post-characterization tests were done before, between, and after each stress method to determine the changes in electrical performance, cell metallization properties, and hotspot properties. It is observed that fresh GG modules showed little/no degradation (less than 1%) in maximum power (Pmax), whereas the GG modules that underwent sequential DH and PID degraded by 11% to 12%. Potential mechanisms for these degradations are also presented. Furthermore, the results presented in this study are critical for the industry, considering that the bifacial modules with GG construction will be dominant in the next 10 years.

14 SOLAR ENERGY↗

Accelerated aging of all-inorganic, interface-stabilized perovskite solar cells

To understand degradation routes and improve the stability of perovskite solar cells (PSCs), accelerated aging tests are needed. Here, we use elevated temperatures (up to 110°C) to quantify the accelerated degradation of encapsulated CsPbI 3 PSCs under constant illumination. Incorporating a two-dimensional (2D) Cs 2 PbI 2 Cl 2 capping layer between the perovskite active layer and hole-transport layer stabilizes the interface while increasing power conversion efficiency of the all-inorganic PSCs from 14.9 to 17.4%. Devices with this 2D capping layer did not degrade at 35°C and required >2100 hours at 110°C under constant illumination to degrade by 20% of their initial efficiency. Degradation acceleration factors based on the observed Arrhenius temperature dependence predict intrinsic lifetimes of 51,000 ± 7000 hours (>5 years) operating continuously at 35°C.

Science & Technology - Other Topics↗

Emissions mitigation technology for advanced water-lean solvent-based CO 2 capture processes

This technical final report submitted to DOE/NETL presents all the research activities performed during the entirety of DE-FE0031660 project-Emissions Mitigation Technology for Advanced Water-Lean Solvent-Based CO 2 Capture Processes which spans from October 2018 through March 2022. RTI International has been conducting studies from fundamental and operational aspects to reduce the overall amine emissions from the advanced Water-Lean Solvent (WLS) systems, specifically RTI’s Non-Aqueous Solvent (NAS). This technical final report will highlight the key findings from project which align closely to the project objectives which are: Identify the contribution of vapor loss, entrainment, and aerosols to the overall emissions of water-lean systems; Determine the significance of CO 2 capture system operating parameters to the amine emissions; Develop an emissions model based on critical operating parameters; Evaluate the effectiveness of emissions mitigation devices to reduce the amine emissions to <1 ppm under flue coal-fired flue gas; and, Determine the contribution of the ECTs to the overall CO 2 capture cost. The following are the key findings based on numerous tests using both lab-scale setups and parametric testing performed at RTI’s Bench-scale Gas Absorption System (BsGAS). During the BP1, the aerosol generation system and monitoring equipment were installed at BsGAS to produce and determine the aerosol characteristics during the NAS CO 2 capture process. The aerosol produced by this setup produced aerosols with the peak diameter and concentration of 50 micron and 1.2E10 7 cm -3 , respectively. These particle sizes and concentrations are matched to those observed in the actual coal-fired power plant flue gases and expected to be found at the absorber inlet of the CO 2 capture system. Over 1,300 hours of parametric testing have been conducted to evaluate the impact of the aerosols and operating conditions during the CO 2 capture with NAS on the overall amine emissions in the treated flue gas. At the worse condition tested, the presence of the aerosols in the flue gas could increase the overall emissions by 10X compared to the baseline emissions from NAS’s vapor pressure. CO 2 capture rate was found to be a main factor impacting the overall emissions as well as aerosol size and concentrations in the absorber off-gas. The higher CO 2 capture rate, the higher amine emissions in the treated gas. The temperature difference between the temperature bulge seen in the absorber and the water wash temperature also impacts the particle growth where the larger the temperature difference, the more amine emissions from aerosols in the treated gas. The majority of the aerosols did not grow substantially in the system, and the particle concentrations remained nearly constant between the absorber inlet and wash outlet. Only a small portion of the particles were found to grow significantly. The high efficiency demister with mesh size of 5-10 micron can be installed to remove a portion of the aerosols from the gas stream leaving the water wash. Overall, these results from parametric testing have established the emission baseline and validate our assumption on the need of emission control technologies (ECT) in order to minimize the emissions from the baseline NAS CO 2 capture process. Over 2,000 of BsGAS operating hours was used to investigate a handful of process improvements which led to a selection of the vital few changes that effectively control the amine emissions. These process improvements are lime-coated-filters for absorber gas inlet, advanced demister at the top of the absorber, a second water wash with amine recovery unit were designed, installed, and tested at BsGAS at the end of BP1. The result showed that the NAS CO 2 capture process with these additional emission control devices could lower the amine emission in the treated gas to about 1 ppm using a simulated coal-fire flue gas stream. The main contributor in lowering the amine emission came from the second water wash with amine recovery unit where the amine concentration in the scrubbing water was kept below 2 wt% through a continuous amine removal via an adsorbent bed, resulting in a low amine vapor pressure. The adsorbent bed was regenerated via a direct steam regeneration and the recover amine was returned to the absorber to minimize wastewater and makeup amine. A flue gas generation system was designed and installed during the first half of BP2 to support the emission testing using a real coal-derived flue gas. The system is capable of generating both coal- and natural gas- derived flue gases with the composition of the gaseous species highly resemble to that of the power plant flue gases. The particulates detected in the coal-derived flue gas showed the mean diameter of 1 micron. The CO 2 capture operating was then proceed using the real coal-derived flue gas where the amine emission was controlled to be about 0-3 ppm for the total run time of about 200 hours. Similar testing was conducted with natural gas-derived flue gas and the result showed a highly amine emission of 30 ppm under the total run time of 200 hours. The Principal Component Analysis (PCA) and the Partial Least Squares Projection to Latent Structures (PLS) techniques were applied to the parametric testing data to derive a multivariate statistical model. The model was validated and trained with half of the data collected, and the predictive ability of the model was evaluated using the remaining half of the data. The resulting empirical model was capable of predicting the overall emissions from the NAS process without the ECTs with ±15% accuracy (average absolute deviation, AAD) in BP1. As more emission data were obtained under the real coal-flue gas in the BP2, the model incorporated these new set of data to reflect the final process configuration, operating parameters, and amine emission. This results in the updated empirical model predicting the amine emission from the NAS CO 2 capture process with 84% goodness-of-fit (R 2 ), 85% predictability (Q 2 ), and 15% AAD. The study evaluates the use of RTI’s Non-Aqueous Solvent technology for 90% CO 2 capture from a net 650 MWe pulverized coal power plant, downstream of the flue-gas desulfurization unit. The captured CO 2 has a purity of > 95% CO 2 , and is dried, compressed to 15.3 MPa (2,215 psia), ready for sequestration. The analysis uses Case B12B from the DOE Baseline study on Bituminous Coal, Revision 4 where the Cansolv CO 2 capture plant is replaced by the RTI CO 2 Capture plant. The CO 2 capture plant has been sized to capture >90% CO 2 from flue gas derived from a net 650 MWe supercritical pulverized coal power plant. The CO 2 capture plant is equipped with emission control technologies that limits the amine emissions to < 1 ppm. Two different cases were evaluated for the technoeconomic study. The key difference between the two cases is the regenerator pressure. In Case 1, the regenerator operates at 0.195 MPa (28.3 psia), whereas in Case 2, the regenerator pressure is 0.44 MPa (64 psia) thus removing the need for the first stage of compression of the eight-stage compression train. Results from the TEA are compared against the DOE reference cases for SCPC plant with and without CO 2 Capture (Case B12A and Case B12B of the DOE Baseline study, respectively). Case 2 with CO 2 regeneration at higher pressure results in the lower cost of CO 2 capture. The total capital cost of the capture process has been estimated using 2018 dollars in Aspen Process Economic Analyzer and was estimated to be $579 MM. The capture plant operation leads to a total parasitic power loss rate of 96 MWe, resulting in a decrease in pulverized coal power plant efficiency of 7.8% points. The resulting cost of electric power increases from 64.4 mills/kWh, for no capture, to 97.5 mills/kWh, with 90% capture, an increase of 51% in the COE. The cost of capturing 90% CO 2 was estimated to be $38.2/tonne-CO 2 , and meets the DOE target of $40/t-CO 2 . Emission control technologies (ECT) investigated in this project includes a second water wash with use of activated carbon beds for removal of amine from the wash water prior to recirculation in the water wash. These ECT allow operation of the CO 2 capture plant with < 1 ppm amine emissions with the treated flue gas and contributes to $2.4/t-CO 2 captured. Amine emissions derived from thermal and oxidative degradations were investigated under this project along with the emissions derived from aerosols for the NAS system. The thermally degraded of the lean NAS showed less than 4% decreased of the original total amine content in the NAS at 150 °C while the result obtained at 120 °C showed no drop in total amine content, suggesting that thermal degradation of the NAS is minimal. These results also suggested that the thermally degraded species are not likely formed and contributed to the emissions due to the low regeneration temperature of the NAS at 90-105 °C. The oxidative degradation, on the other hand, could become problematic as some of these oxidative degraded species were observed during the NAS-5 testing at National Carbon Capture Center (NCCC) and SINTEF in our previous project. The rapid screening of selected inhibitors suggested that oxidative degradation of NAS can be suppressed using thiol containing compounds in amounts of at least 1 mol%. The detailed mechanistic degradation pathway was conceived for a specific amine used in NAS formulation during BP2. he reduction of the nitrosamines caused by the NO x present in the flue gas was also examined. The study suggested that the thermo-chemical treatment of the NAS solvent would be a more effective and economically viable compared to removing NO x at the DCC.

01 COAL, LIGNITE, AND PEAT↗

Degradation Dynamics of Perovskite Solar Cells Under Fixed Reverse Current Injection

Previous studies of reverse-bias stability in perovskite solar cells have focused primarily on voltage controlled reverse-bias tests. Here we instead present an investigation of perovskite solar cell degradation under well-defined, constant reverse-current stress. We show that the choice of hole-transport layer dictates the dominant degradation pathway: cells using thick poly(triphenylamine) (PTAA) layers with better indium-doped tin oxide (ITO) coverage can tolerate high reverse bias but quickly undergo catastrophic breakdown under fixed reverse current near their one-sun maximum power-point. In contrast, cells modified with the phosphonic-acid interface layer MeO-2PACz, with poorer ITO coverage compared to PTAA, exhibit soft, gradual, and largely recoverable degradation, regardless of the shading conditions. For MeO-2PACz devices, degradation increases with both current magnitude and duration. Importantly, when normalized by injected charge (current times duration), lower currents applied over longer times cause more severe degradation than higher currents over shorter periods. Combining electrical measurements with spatially resolved photoluminescence imaging, we argue against shunt formation and instead support an ion- and charge-mediated interfacial electrochemical degradation mode.

Applied Physics (physics.app-ph)↗

Mitigation of Boiling-Induced Thermal Degradation Using Microporous Nickel Inverse Opals Structures

Engineered microporous structures have received much attention in high-heat-flux electronics cooling due to their high thermal conductivity and permeability, and large surface area for heat transfer, but are susceptible to boiling-induced thermal degradation. Here, this study investigates the efficacy of nickel inverse opals (NiIOs) in mitigating structural degradation caused by corrosion-assisted erosion during pool boiling with water as the working fluid. First, we compared the reliability of NiIOs to copper inverse opals (CuIOs) for a 3-day pool boiling test at constant heat flux. The NiIOs demonstrated superior resistance to thermal degradation due to their inherent corrosion resistance and mechanical strength. Subsequently, we conducted a more controlled experiment to show the effect of heat flux on the degradation of the NiIOs while excluding the effect of temperature variations. Pool boiling tests of 20-μm-thickness NiIOs covering an area of ∼11 × 11 mm 2 with a 2.5 × 2.5 mm 2 heater at the center were conducted at heat flux levels of 20%, 40%, and 60% of the critical heat flux (CHF) for 3 days. The NiIOs subjected to heat flux levels of 20% and 40% CHF showed minimal degradation, while the sample subjected to 60% CHF showed erosion on the top surface due to higher bubble formation and departure rate. These results show the potential of NiIOs as a promising solution for long-term thermal management in high-power electronic devices, although design considerations for maximum allowable heat flux are necessary for reliable operation.

36 MATERIALS SCIENCE↗

Effects of forest degradation classification on the uncertainty of aboveground carbon estimates in the Amazon

Tropical forests are critical for the global carbon budget, yet they have been threatened by deforestation and forest degradation by fire, selective logging, and fragmentation. Existing uncertainties on land cover classification and in biomass estimates hinder accurate attribution of carbon emissions to specific forest classes. In this study, we used textural metrics derived from PlanetScope images to implement a probabilistic classification framework to identify intact, logged and burned forests in three Amazonian sites. We also estimated biomass for these forest classes using airborne lidar and compared biomass uncertainties using the lidar-derived estimates only to biomass uncertainties considering the forest degradation classification as well. Our classification approach reached overall accuracy of 0.86, with accuracy at individual sites varying from 0.69 to 0.93. Logged forests showed variable biomass changes, while burned forests showed an average carbon loss of 35%. We found that including uncertainty in forest degradation classification significantly increased uncertainty and decreased estimates of mean carbon density in two of the three test sites. Our findings indicate that the attribution of biomass changes to forest degradation classes needs to account for the uncertainty in forest degradation classification. By combining very high-resolution images with lidar data, we could attribute carbon stock changes to specific pathways of forest degradation. This approach also allows quantifying uncertainties of carbon emissions associated with forest degradation through logging and fire. Both the attribution and uncertainty quantification provide critical information for national greenhouse gas inventories.

54 ENVIRONMENTAL SCIENCES↗

Nafion Passivation of c-Si Surface and Edge for Electron Paramagnetic Resonance

Effective surface passivation of crystalline silicon (c-Si) surface by reducing the carrier recombination rate has led to modern c-Si solar cells with efficiencies > 25% in both laboratory and industrial settings. Typical mainstream surface passivation techniques include high-temperature silicon oxide (SiOx), amorphous silicon (a-Si:H), hydrogen-rich silicon nitride (SiNx), and aluminum oxide (Al2O3) [1]. They have demonstrated excellent surface recombination velocity of < 1 cm/s owing to both chemical passivation (via the hydrogen saturation of Si dangling bonds at the c-Si surface), and field-effect passivation (via the band bending from the fixed charge of the dielectric layers). Recently, several groups have studied solution-based organic materials for c-Si passivation, including bis(trifluoromethane)sulfonimide (TFSI), polystyrenesulfonate, and Nafion [2, 3] via spin or dip coating. All films were processed at ambient room temperature, and a high lifetime of 12 ms, as well as a low saturation current density (J0) of 16 fA/cm2, have been demonstrated using Nafion passivation [2]. However, despite the air instability, Nafion has several advantages when introduced to PV applications: (a) Wafer quality can be measured at high throughput after several process stages. (b) It is compatible with PL mapping, compared to HF liquid passivation which cannot be performed in room ambient. (c) Nafion process is fast and poses fewer constraints on process complexity, and cleanness, compared to Al2O3 and a-Si:H passivation. (d) Nafion is the ideal room temperature passivation, which can be applied onto a small fragment of a degraded module to investigate microscopic mechanisms when studying degradation mechanisms. Edge passivation is needed for advanced characterization tests such as Electron Paramagnetic Resonance (EPR), Electrically Detected Magnetic Resonance (EDMR), Deep Level Transient Spectroscopy (DLTS), local cell current-voltage (J-V), and Suns-Voc. In such cases, the laser-damaged minicell edges will obscure the true degradation mechanisms, and Nafion can effectively passivate them without causing further degradation through elevated-temperature processes. In this contribution, we show the passivation results of Nafion on bare nCz and compare it with a Al2O3 witness. We highlight the importance of edge pre-treatment before Nafion to achieve good passivation. We show that Nafion can reach decent passivation without undergoing high-temperature processes. We also explore the temperature dependency of Nafion through photoluminescence (PL) study and demonstrate the application of Nafion under cryogenic temperature (~6 K) through EPR. Our results reveal that Nafion can reduce surface and edge Si dangling bonds at low temperatures. Thus, it can be used as an effective room temperature passivation technique for advanced characterization methods.

c-Si↗

Impact of Porous Transport Layer Morphology on the Performance of Proton Exchange Membrane Water Electrolyzers with Ultra-Low Iridium Loadings

Reducing Ir loadings in proton exchange membrane water electrolyzer anodes is critical for lowering capital expenses. Loading reduction could be achieved by improving the Ir activity via doping/alloying and/or the development of advanced microstructures. However, the anode porous transport layer (PTL) is a comparatively simple component whose properties also impact Ir utilization. Therefore, well-designed PTLs may also enable reduced Ir loadings. In this work, we survey eight PTLs from various manufacturers to observe their impact on cell performance at low (0.4 mg Ir cm -2 ) and ultralow (0.1 mg Ir cm -2 ) Ir loadings. The PTLs were characterized by their microstructural properties, including porosity, particle size distribution, and pore size distribution. Electrochemical cell performance was correlated to PTL morphology, and it was found that PTLs with lower porosities and smaller particle and pore radii enabled good performance even at ultralow Ir loadings. 1000-h durability testing indicated that using lower porosity PTLs can significantly improve durability behavior. A runaway voltage phenomenon was observed during durability testing of cells with ultralow Ir loadings, which was caused by increases in both anode and cathode overpotentials. Furthermore, we observed that the beginning of test performance of 0.1 mg Ir cm -2 cells correlates to the 1000-h degradation rates of 0.4 mg Ir cm -2 cells, suggesting that for the Ir catalyst used in this work, short-term testing at ultralow loadings can be used as an indicator of long-term degradation at higher loadings.

08 HYDROGEN↗

A New UV Spot Test for Quality Control

Here, we present a fast, low-cost ultraviolet (UV) spot test to screen photovoltaic modules for UV-induced degradation (UVID). The measurement is based on a fiber-coupled arc lamp that delivers a highly accelerated local UV dose-approximately five years of equivalent field exposure in less than a day. Spot-exposed areas are evaluated using electroluminescence imaging. We test a “known bad” product, which was observed to experience UVID in the field, and a “known good” product which did not exhibit UVID in the field. Results indicate that the method may be useful as a quick and relatively inexpensive quality control screening tool for customers and manufacturers.

14 SOLAR ENERGY↗

Hydroxyl Conducting Hydrogels Enable Low-Maintenance Commercially Sized Rechargeable Zn–MnO2 Batteries for Use in Solar Microgrids

Zinc (Zn)–manganese dioxide (MnO2) rechargeable batteries have attracted research interest because of high specific theoretical capacity as well as being environmentally friendly, intrinsically safe and low-cost. Liquid electrolytes, such as potassium hydroxide, are historically used in these batteries; however, many failure mechanisms of the Zn–MnO2 battery chemistry result from the use of liquid electrolytes, including the formation of electrochemically inert phases such as hetaerolite (ZnMn2O4) and the promotion of shape change of the Zn electrode. This manuscript reports on the fundamental and commercial results of gel electrolytes for use in rechargeable Zn–MnO2 batteries as an alternative to liquid electrolytes. The manuscript also reports on novel properties of the gelled electrolyte such as limiting the overdischarge of Zn anodes, which is a problem in liquid electrolyte, and finally its use in solar microgrid applications, which is a first in academic literature. Potentiostatic and galvanostatic tests with the optimized gel electrolyte showed higher capacity retention compared to the tests with the liquid electrolyte, suggesting that gel electrolyte helps reduce Mn3+ dissolution and zincate ion migration from the Zn anode, improving reversibility. Cycling tests for commercially sized prismatic cells showed the gel electrolyte had exceptional cycle life, showing 100% capacity retention for >700 cycles at 9.5 Ah and for >300 cycles at 19 Ah, while the 19 Ah prismatic cell with a liquid electrolyte showed discharge capacity degradation at 100th cycle. We also performed overdischarge protection tests, in which a commercialized prismatic cell with the gel electrolyte was discharged to 0 V and achieved stable discharge capacities, while the liquid electrolyte cell showed discharge capacity fade in the first few cycles. Finally, the gel electrolyte batteries were tested under IEC solar off-grid protocol. It was noted that the gelled Zn–MnO2 batteries outperformed the Pb–acid batteries. Additionally, a designed system nameplated at 2 kWh with a 12 V system with 72 prismatic cells was tested with the same protocol, and it has entered its third year of cycling. This suggests that Zn–MnO2 rechargeable batteries with the gel electrolyte will be an ideal candidate for solar microgrid systems and grid storage in general.

25 ENERGY STORAGE↗

A Custom High-Throughput Optical Mapping Instrument (OMI) for Accelerated Stress Testing of PV Module Materials

The performance and integrity of photovoltaic (PV) modules and materials may be assessed through optical characterizations. We have developed a custom Optical Mapping Instrument (OMI) to improve measurement throughput time, facilitate automated measurements, and obtain spatial information relative to commercial benchtop spectrophotometer instruments. Both the key components and the methods used to improve the measurements are described. The measurement precision for the OMI is benchmarked for hemispherical transmittance relative to a previous round-robin study for commercial spectrophotometers. Example mapping measurements and their implications are given for specimens from other studies, including: (1) the depletion of the UV absorber is revealed for specimens beyond a certain size after standardized artificial ultraviolet (UV) weathering, (2) an optical degradation by internal haze formation is confirmed following Damp Heat (85°C/85% relative humidity) testing, (3) the better uniformity of the wear pattern for falling sand abrasion is used to select the DIN 52348 fixture over the ASTM D968 fixture, and (4) the local (millimeter-scale) heterogeneity of surface contamination in the soiling-prone location of Dubai relative to Kuwait. The results of the UV study have already been used to improve the standardized weathering of encapsulants. The example for Damp Heat testing is given to increase awareness of a degradation believed to be ubiquitously occurring in safety and design-type qualification testing of PV modules.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Evaluation of Zero-Net-Rate Pumping Tests

Accurately estimating the distribution of aquifer properties is key to understanding contaminant movement in the subsurface. The distribution of aquifer properties is typically addressed using slug or constant-rate well tests, and the pros and cons of these tests are well known. Slug tests are appealing because they avoid removing contaminated water, but their results are affected by well skin and the small volume of displaced water limits the volume of aquifer that can be evaluated. Constant-rate well tests have the disadvantage of requiring disposal of potentially contaminated water, but they can generate properties that are more representative than slug tests, and they can be used to estimate well efficiency and storativity, which are difficult to characterize using slug tests. Periodic pumping tests are appealing because they have many of the advantages and few of the disadvantages of slug and constant-rate well tests. Periodic pumping tests involve cycling the pumping rate with a regular period and measuring the resulting response in monitoring wells. Some of these tests involve imposing a periodic rate on a constant mean rate. However, other tests involve moving water out and back into the well at rates that are balanced so the net rate after each period is zero. Some zero-net-rate (ZNR) well tests use rates that follow a sinusoidal pattern, whereas others use a square wave pattern that switches between a constant rate of pumping and a constant rate of injection to achieve a zero-net rate. ZNR well tests appear to be a useful compromise between slug and constant rate tests, but methods for conducting and analyzing the results from these tests have received limited evaluation. Periodic pumping tests are typically evaluated through recorded pressure responses to a disturbance source. Recent work has demonstrated that the strain field in the vadose zone shows a response to disturbances in the underlying aquifer. Various instrument designs are available that can record vertical and horizontal strain to very precise resolutions (10-9 ε). Measuring the strain in the vadose zone can present lower costs than measuring pressure in a monitoring well, so using strain could improve the resolution of ZNR tests, as well as make these tests potentially cheaper. A ZNR periodic pumping system was constructed and used to perform tests in the Clemson, South Carolina area. The system was designed to pump and inject with a periodic square-wave, so pumping occurs at a constant rate for half the period and is followed by injection at the same rate for half the period resulting in no net gain or loss of water from the aquifer. The system is designed to generate flow rates from 1 to 3.5 gallons per minute (gpm) with a capacity of 875-gallon per half period. Pressure and strain monitoring points are located in the vicinity of the pumping well. A series of 10 ZNR periodic pumping tests were conducted at the field site, with periods ranging from 2 to 540 minutes. Pressure data were collected and recorded in four monitoring wells in various locations around the pumping well. In addition, vertical and horizontal strain and tilt data were recorded in various locations around the pumping well. Traditional aquifer tests, including slug tests and constant-rate pumping tests were conducted at the field site to provide a baseline of aquifer parameter estimates that are compared the results of ZNR tests. Pressure data measured at monitoring wells during ZNR tests were analyzed utilizing an analytical solution (Streltsova, 1988) that assumes a confined aquifer and estimates hydraulic diffusivity and transmissivity using the time lag and amplitude of the pressure signal. The storativity can be separated out from the hydraulic diffusivity using the transmissivity estimate. The time-lag and amplitude of the pressure signals were estimated using a Fourier transform. The time-lag of the primary period of the pressure increases as a linear function of distance from the pumping well, and it increases as the square root of the period of the ZNR test over a range of periods spanning two orders of magnitudes. The first few harmonics follow similar trends, but the higher frequency harmonics diverge from this trend. Strain and tilt data from various instruments in the vadose and saturated zones are periodic during ZNR tests. The time lags of the strain components increase roughly linearly with distance from the well. Many of the time lags of the strain data from the vadose zone are similar to the time lags observed in the pressure data from a similar distance and pumping period. Theoretical experiments were performed to understand how pressure and strain responds to ZNR periodic pumping. The time-lags of the simulated pressure responses match the field data trends. The results were used to validate the Streltsova (1988) solution for periodic pumping to estimate hydraulic diffusivity. Hydraulic diffusivity was estimated to be 1.8 x 10-2 m2s-1 < Dh < 9.0 x 10-2 m2s-1 using pressure data from all the wells during ZNR tests. Transmissivity was estimated to be 0.8 x 10-4 m2s-1 < T < 4.3 x 10-4 m2s-1. Assuming Storativity = T/Dh gives 1.1 x 10-3 < S < 19 x10-3. Transmissivity is used to estimate the hydraulic conductivity, K, by dividing by the assumed aquifer thickness. Two constant-rate pumping tests were conducted and analyzed using two conceptual models: The Hantush (1961) solution was used to analyze data assuming confined conditions and the Neuman (1974) solution was used to analyze data assuming unconfined conditions. The Hantush (1961) solution estimated transmissivity to be 1.6 x 10-4 m2s-1 < T < 1.8 x 10-4 m2s-1 when using data from all the wells. Storativity was estimated to be 4.4 x 10-3 < S < 8.2 x 10-3. Assuming Dh = T/S gives 0.22 x 10-2 m2s-1 < Dh < 3.6 x 10-2 m2s-1. The Neuman (1974) solution estimated transmissivity to be 0.80 x 10-4 m2s-1 < T < 0.84 x 10-4 m2s-1. Total storativity (S + Sy) was estimated to be 22 x 10-3 < S < 110 x 10-3. Storativity excluding the Sy term was estimated to be 2.2 x 10-3 < S < 2.5 x 10-3. Assuming Dh = T/S gives 0.073 x 10-2 m2s-1 < S < 0.36 x 10-2 m2s-1. Two slug tests were performed on the pumping well, PW-2. The Bouwer and Rice (1976) solution for slug tests was used to analyze the data. This solution works for both confined and unconfined conditions, so both conceptual models were covered through the analysis. Hydraulic conductivity was estimated to be 1.95 x 10-6 ms-1 < K < 2.49 x 10-6 ms-1. Statistical comparison show generally no significant difference in the estimates of Dh, K, or S made using ZNR and conventional pumping tests.. However, the total storage estimated by the Neuman (1974) solution for unconfined settings is larger than that estimate using the Streltsove analysis applied to the ZNR tests. This is likely because the Neuman solution considers delayed yield from storage that the water table, whereas the Streltsova (1988) solution assumes confined conditions. The analysis also indicates that there is a statistically significant difference between parameters estimated with conventional slug tests and those measured with either constant-rate pumping tests or ZNR tests. Hydraulic diffusivity is estimated from the time-lag and the distance from the well. The time-lags of the strain data from the vadose zone are similar to the lags of the pressure data from a similar distance. This indicates that hydraulic diffusivities estimated from the strain data measured in the vadose zone would be similar to the estimates from the pressure data measured in the aquifer. There appear to be sign reversals in some of the strain data that were corrected to estimate the time lag. The dissolved oxygen (CO) concentration was measured during several ZNR tests to evaluate the feasibility of using the procedure to increase contaminant degradation kinetics that are related to DO. The results indicate that DO can be increased during the cycling of ZNR tests in some cases.

Smith-Jones, Austin↗

Organic Evaporation and Oxidation Testing in Support of Hanford Sample-and-Send

The Hanford site has approximately 56 million gallons of radioactive mixed waste stored in 177 underground storage tanks. The Hanford Waste Treatment and Immobilization Plant (WTP) is being built to treat and immobilize the tank waste. The baseline method for immobilization of Low Activity Waste (LAW) through the WTP is vitrification, but additional immobilization capacity is needed to supplement the initial LAW melters. An alternative cementitious waste form is being investigated for that future immobilization method to supplement vitrification. However, one impediment to a cementitious waste form is the presence of Land Disposal Restricted (LDR) organic chemicals in tank waste. This work evaluates potential avenues to eliminate that impediment to permit possible use of a cementitious waste form and work towards a decision whether additional LDR organic pretreatment would be required. Savannah River National Laboratory (SRNL) performed testing using simulants to examine evaporation as a method to remove some prevalent organics from LAW. Spiking the caustic LAW simulant with selected regulated organic chemicals found one that clearly decomposes because of caustic instability. Oxidation testing of other organic chemicals found some LDR organics degrade as desired and others are stable in the presence of peroxide and permanganate. In addition to studies with simulants, a literature review was performed to evaluate radiological stability of LDR organics. Descriptions of the experimental details, equipment, and results are included in this report. Evaporation testing consisted of preparing the LAW simulant, spiking that simulant with organic chemicals, and evaporating the mixture via differential distillation. The apparatus was a laboratory-scale vacuum evaporator operated at 60 ±5 torr absolute (vacuum evaporation) and also at atmospheric pressure. The LAW simulant represented the liquid expected to be retrieved from the Hanford tank farms at approximately 4.0 M [Na + ] total sodium ion concentration. The concentration of the organic chemicals added was significantly higher than typically found in the tank waste samples since the higher levels were necessary to assist in analytical measurement and tracking of the spiked species. Organic chemicals were chosen for the work with a consideration of how their volatility compares with that of methanol. This was done by comparing the ratio of the pure water Henry’s law coefficient (K h ) of methanol to that of the compound in question (hereafter termed the K h ratio), where ratios above unity indicated less volatility than methanol. Methanol was chosen because it is a common regulated chemical with relatively low volatility but which has been removed by evaporation in previous laboratory work. While organic separation results depend on evaporator design, laboratory experiments verified that organic partitioning to the overhead condensate stream by evaporation is a practical process. The work reported here found difficulties in quantitative analysis of the organic chemicals in aqueous samples. Most of the time there was insufficient analysis to close a mass balance for evaporator runs, but qualitative evidence of carryover was obtained. The methods were also able to show whether organic chemicals were susceptible or resistant to solution oxidation in permanganate or hydrogen peroxide tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Degradation Effects at the Porous Transport Layer/Catalyst Layer Interface in Polymer Electrolyte Membrane Water Electrolyzer

The porous transport layer (PTL)/catalyst layer (CL) interface plays a crucial role in the achievement of high performance and efficiency in polymer electrolyte membrane water electrolyzers (PEMWEs). This study investigated the effects of the PTL/CL interface on the degradation of membrane electrode assemblies (MEAs) during a 4000 h test, comparing the MEAs assembled with uncoated and Ir-coated Ti PTLs. Our results show that compared to an uncoated PTL/CL interface, an optimized interface formed when using a platinum group metal (PGM) coating, i.e., an iridium layer at the PTL/CL interface, and reduced the degradation of the MEA. The agglomeration and formation of voids and cracks could be found for both MEAs after the long-term test, but the incorporation of an Ir coating on the PTL did not affect the morphology change or oxidation of IrO x in the catalyst layer. In addition, our studies suggest that the ionomer loss and restructuring of the anodic MEA can also be reduced by Ir coating of the PTL/CL interface. Optimization of the PTL/CL interface improves the performance and durability of a PEMWE.

30 DIRECT ENERGY CONVERSION↗