Search NASA⌕ Search

SEARCH · Search NASA

Results for “demagnetization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

268 records · Page 15

Vibration-Heating in ADR Kevlar Suspension Systems

The cryogenics group at NASA's Goddard Space Flight Center has a long-standing development and test program for laboratory and space-flight adiabatic demagnetization refrigerators (ADRs). These devices are used to cool components to temperatures as low as 0.05 K. At such low temperatures the ADR systems can provide a few micro-Watts of cooling power, so it is important to minimize the conduction of heat to these cold stages from the surroundings. The cold ADR elements are held in place by thin tensioned strings made of Kevlar, chosen for its high strength and stiffness and low thermal conductivity. During laboratory testing, we have observed that occasional significant additional heat loads on the coldest ADR stages correlate with unusually high vibration levels in the cryostat due to a noisy mechanical cryocooler. We theorized that this heat results from plastic deformation of the Kevlar fibers and frictional interactions among them, driven by the cryostat vibrations. We describe tests and calculations performed in attempt to confirm this source of the heating, and we discuss possible strategies to reduce this effect in future ADR suspension systems.

Vibration-heating↗

High Temperature Superconductor Lead Assemblies for XRISM

The RESOLVE instrument on the upcoming XRISM mission is a rebuild of the SXS instrument that successfully demonstrated high resolution X-ray spectroscopy on the Hitomi mission using a microcalorimeter array at 50 mK. As with SXS, the RESOLVE instrument requires High Temperature Superconductor (HTS) lead assemblies to carry high current to the Adiabatic Demagnetization Refrigerator (ADR) while meeting a very stringent heat conductance budget. For the RESOLVE HTS lead assemblies, we have used new materials and processes to improve the stability and consistency of solder joints to the HTS material. We have also designed a new thermal strap that eliminates stress concentrations on the HTS tapes. We present the results of testing on the engineering model and flight model units, as well as the results of long term testing on prototype solder joints.

Canavan, Edgar R.↗

Electron Diffusion Regions in Magnetotail Reconnection Under Varying Guide Fields

Kinetic structures of electron diffusion regions (EDRs) under finite guide fields in magnetotail reconnection are reported. The EDRs with guide fields 0.14–0.5 (in unit of the reconnecting component) are detected by the Magnetospheric Multiscale spacecraft. The key new features include the following: (1) cold inflowing electrons accelerated along the guide field and demagnetized at the magnetic field minimum while remaining a coherent population with a low perpendicular temperature, (2) wave fluctuations generating strong perpendicular electron flows followed by alternating parallel flows inside the reconnecting current sheet under an intermediate guide field, and (3) gyrophase bunched electrons with high parallel speeds leaving the X‐line region. The normalized reconnection rates for the three EDRs range from 0.05 to 0.3. The measurements reveal that finite guide fields introduce new mechanisms to break the electron frozen‐in condition.

Chen, L.‐J.↗

Sub-Kelvin Cooling for Two Kilopixel Bolometer Arrays in the PIPER Receiver

The Primordial Inflation Polarization Explorer (PIPER) is a balloon-borne telescope mission to search for inflationary gravitational waves from the early universe. PIPER employs two 32 × 40 arrays of superconducting transition-edge sensors, which operate at 100 mK. An open bucket Dewar of liquid helium maintains the receiver and telescope optics at 1.7 K. We describe the thermal design of the receiver and sub-Kelvin cooling with a continuous adiabatic demagnetization refrigerator (CADR). The CADR operates between 70 and 130 mK and provides ≈10 μW cooling power at 100 mK, nearly five times the loading of the two detector assemblies. We describe electronics and software to robustly control the CADR, overall CADR performance in flightlike integrated receiver testing, and practical considerations for implementation in the balloon float environment.

Switzer, E. R.↗

Lynx X-Ray Microcalorimeter Cryogenic System

The Lynx x-ray microcalorimeter instrument on the Lynx X-ray Observatory requires a state-of-the-art cryogenic system to enable high-precision and high-resolution x-ray spectroscopy. The cryogenic system and components described provide the required environment using cooling technologies that are already at relatively high technology readiness levels and are progressing toward flight-compatible subsystems. These subsystems comprise a cryostat, a 4.5-K mechanical cryocooler, and an adiabatic demagnetization refrigerator that provides substantial cooling power at 50 mK.

DiPirro, Michael↗

Twinned magnetite in granitic samples from the Siljan impact structure, Sweden

Impact cratering is a ubiquitous process throughout the solar system and has played a key role for the geologic evolution of Earth and other planets [1]. Magnetic anomalies are common characteristics of impact craters [2], so understanding how magnetite (Fe23+Fe2+O42-), an important magnetic carrier in both terrestrial and extraterrestrial rocks, is affected by shock waves, especially structurally and magnetically, is crucial. Magnetic minerals have been studied to gain insight into the geologic evolution of Mars, with specific focus including understanding the Martian crustal structure and the oxidization state of Martian rocks (e.g., [3,4,5]). Shock waves permanently alter the intrinsic magnetic properties of rocks (e.g., [6]), as do twinning in natural environments with less extreme P/T conditions [7]. In fact, pressure conditions induced by impacts have been suggested to explain demagnetization signatures observed around Martian impact basins [8]. It is still poorly understood what effects shock has on the crystallographic structure of magnetite and thus it’s intrinsic magnetic properties, and , how that affects the bulk magnetic properties of rocks (e.g., [9]). Limited experimental studies have investigated the effects of shock compression on magnetite, especially with the aim of describing crystallographic deformation (e.g., [9] and references therein). In this work we report preliminary results of an investigation of microstructures in magnetite, an “unconventional” mineral in shock studies, in granitic samples from the ca. 380 Ma ~52 km-in-diameter Siljan impact structure, located in south-central Sweden.

shock metamorphism↗

Finding and Fixing a Small Low Temperature Leak - A Case Study on XRISM/Resolve

The Resolve instrument on the X-Ray Imaging and Spectroscopy Mission (XRISM) uses an Adiabatic Demagnetization Refrigerator (ADR) to cool extremely sensitive x-ray microcalorimeters to 50 mK. A 40-liter superfluid helium dewar and a 4.5 K Joule Thomson (JT)/Stirling cryocooler serve as heat sinks for the ADR and staged cooling for the dewar. The superfluid helium lifetime is required to last at least 3 years on orbit with margin. The superfluid helium dewar developed a small leak (~5e-7 Pa m^3/s) at low temperature which compromised the dewar vacuum in two days of ground testing. It turns out that this leak disappears completely at room temperature (<5e-13 Pa m^3/s). This presentation describes the lengthy process of characterizing, isolating, and ultimately, repairing this leak.

Michael DiPirro↗

Magnetospheric Multiscale Observations of an Expanding Oxygen Wave in Magnetic Reconnection

Heavier plasma species such as oxygen ions can have a large impact on the magnetic reconnection process. It has been hypothesized that the acceleration of demagnetized oxygen ions by the Hall electric field will lead to the formation of an oxygen wave that expands into the exhaust. By comparing data from NASA's Magnetospheric Multiscale mission to a fully kinetic particle-in-cell simulation, we can for the first time provide observational evidence of such an expanding oxygen wave. The wave is characterized by an oxygen jet consisting of cold ions directed toward the neutral sheet associated with a density cavity. This density cavity forms as the EO are subject to collective acceleration by the Hall electric field leaving behind a region of low-density oxygen ions. Our results are important for the understanding of the role and effect of oxygen ions in magnetic reconnection.

Hakon Midthun Kolsto↗

Critical Current Stability of 2G REBCO Tape for Space-Flight HTS Leads

High reliability is an essential requirement for all spaceflight hardware. XRISM, a follow-on mission to the Hitomi x-ray observatory, also uses 2G REBCO tapes as current leads for the superconducting magnets that are a key component of the Adiabatic Demagnetization Refrigerator (ADR) that cools the detector array. While the Hitomi Soft X-ray Spectrometer (SXS) worked flawlessly in orbit, during its development there were indications that the critical current of its specialized REBCO tapes could degrade over time when exposed to normal-humidity air. To demonstrate that the updates to the XRISM HTS lead assemblies had mitigated this risk, a series of tests were carried out to measure the stability of Ic of dozens of samples over a period greater than the flight assemblies were exposed to air during integration and test. The test rig allowed not only the measurement of the sample Ic, but also the localization of the voltage rise as the current approached Ic. We will discuss the trends in the critical current of the samples, as well as localization of lower Ic regions.

Edgar R. Canavan↗

A Four-Stage Continuous ADR for Space Missions

The cryogenics group at NASA-Goddard has provided adiabatic demagnetization refrigerators (ADRs) for cooling detectors to sub-Kelvin temperatures in space. These ADRs were single-shot devices that produced cooling at 0.05 K for tens of hours before needing to be recycled. Our group also developed a four-stage laboratory ADR system which holds one stage continuously at 0.05K, or colder, while using the other stages to pump heat from the continuous stage up to a heat sink near 4K. This continuous ADR (CADR) provides a useful cooling power that is more than 10 times greater at 0.050 K than what was required by the single-shot space systems. Over the past several years, this system was updated so that it can withstand the rigors of a launch into space. We describe this development process and report its final results.

Continuous ADR↗

A Four-Stage Continuous ADR for Space Missions

The cryogenics group at NASA-Goddard has provided adiabatic demagnetization refrigerators (ADRs) for cooling detectors to sub-Kelvin temperatures in space. These ADRs were single-shot devices that produced cooling at 0.05 K for tens of hours before needing to be recycled. Our group also developed a four-stage laboratory ADR system which holds one stage continuously at 0.05K, or colder, while using the other stages to pump heat from the continuous stage up to a heat sink near 4K. This continuous ADR (CADR) provides a useful cooling power that is more than 10 times greater at 0.050 K than what was required by the single-shot space systems. Over the past several years, this system was updated so that it can withstand the rigors of a launch into space. We describe this development process and report its final results.

Continuous ADR↗

Cryogenics and Fluids at NASA-Goddard Space Flight Center

Abstract: Spacecraft thermal design presents unique thermal and fluid challenges caused by a variety of harsh spacecraft thermal environments. In addition, at cryogenic temperatures (i.e., less than 123 K (-150° C), and sometimes as low as 50 milliKelvin), more challenges arise, such as the increasing importance of mitigating thermal radiation, the effects of coefficient of thermal expansion mismatches between different materials, changes in the physics behavior of materials, and increasing thermodynamic difficulty of lifting heat up large temperature gradients. In this talk, Dr. Rueger will present a broad overview of spacecraft thermal environments; cryogenic design practices; components of interest for the Cryogenics and Fluids Branch (e.g., cryocoolers, adiabatic demagnetization refrigerators, heat switches, and superconducting leads); cryogenic considerations in some current NASA mission examples (e.g., the DragonFly mission to Titan and the X-ray Imaging and Spectroscopy Mission); and capabilities of the Cryogenics and Fluids Branch at NASA.

Paul Rueger↗

Measuring the Liquid Helium Volume on XRISM and Predicting the Liquid Lifetime

The XRISM/Resolve instrument uses an adiabatic demagnetization refrigerator (ADR) to cool microcalorimeters to 50 mK. The cryogenic system to support the ADR consists of a liquid helium dewar and 5 cryocoolers that provide a semi-redundant system. Operation of the ADR requires either a liquid helium heat sink at 1.2 K or 4.5 K heat sink provided by a multi-stage cryocooler system. The 5 cryocoolers also provide thermal protection to the liquid helium dewar. To calculate the expected lifetime of the liquid helium system, the liquid helium volume was measured before launch and several techniques were employed to determine on-orbit boil off rate.

Michael Dipirro↗

Development and Testing of a Superconducting Ground Plane on Transition Edge Sensors

Much of the normal matter in the universe is thought to exist as diffuse hot gas near 1.0 × 10 6 K, which can be detected through its 0.1–0.5 keV line emission. Distinguishing among multiple temperature regions and emission mechanisms along a line of sight requires resolving individual spectral lines in this particularly crowded spectral range. This requires 1–2 eV spectral resolution, which is currently only possible using grating spectrometers, which are suitable only for point sources, but not for the diffuse sources we wish to observe. We aim to measure individual spectral lines in this energy band using transition edge sensors (TES) that have the required 1–2 eV non-dispersive spectral resolution on a sounding rocket. While TESs offer sufficient energy resolution, they are very sensitive to ambient magnetic fields, e.g. from earth’s field and stray fields from the adiabatic demagnetization refrigerator (ADR) that is used to cool TESs to their ∼70 mK transition temperature. Strict space and weight limitations on the sounding rocket payload will limit the use of conventional high permeability magnetic shielding. Further design challenges arise in designing shielding with at least a 45∘ field of view, which is required to maintain a large enough throughput to obtain a useful spectrum on a brief (∼300 s) sounding rocket flight. Here we explore adding a superconducting ground plane (SGP) to the backside of the TES to reduce its field sensitivity and minimize attenuation requirements for the external shielding, which is based on prior work from (de Wit et al. 2022). We tested the feasibility of SGPs with novel materials, geometries, and on larger TESs with different biasing conditions.

Astrophysics↗

Thermodynamic Analysis of the 3-Stage ADR for the Astro-H Soft X-Ray Spectrometer Instrument

The Soft X-ray Spectrometer (SXS) instrument on Astro-H will use a 3-stage ADR to cool the microcalorimeter array to 50 mK. In the primary operating mode, two stages of the ADR cool the detectors using superfluid helium at 1.20 K as the heat sink. In the secondary mode, which is activated when the liquid helium is depleted, two of the stages continuously cool the (empty) helium tank using a 4.5 K Joule-Thomson cooler as the heat sink, and the third stage cools the detectors. In the design phase, a high-fidelity model of the ADR was developed in order to predict both the cooling capacity and heat rejection rates in both operating modes. The primary sources of heat flow are from the salt pills, hysteresis heat from the magnets and magnetic shields, and power dissipated by the heat switches. The flight instrument dewar, ADR, detectors and electronics were integrated in mid-2014 and have since undergone extensive performance testing, in part to validate the performance model. This paper will present the thermodynamic performance of the ADR, including cooling capacity, heat rejection to the heat sinks, and various measures of efficiency.

space cryogenics↗

Thermodynamic Performance of the 3-Stage ADR for the Astro-H Soft X-Ray Spectrometer Instrument

The Soft X-ray Spectrometer (SXS) instrument[1] on Astro-H[2] will use a 3-stage ADR[3] to cool the microcalorimeter array to 50 mK. In the primary operating mode, two stages of the ADR cool the detectors using superfluid helium at ≤1.20 K as the heat sink[4]. In the secondary mode, which is activated when the liquid helium is depleted, the ADR uses a 4.5 K Joule-Thomson cooler as its heat sink. In this mode, all three stages operate together to continuously cool the (empty) helium tank and singleshot cool the detectors. The flight instrument - dewar, ADR, detectors and electronics - were integrated in 2014 and have since undergone extensive performance testing. This paper presents a thermodynamic analysis of the ADR's operation, including cooling capacity, heat rejection to the heat sinks, and various measures of efficiency.

adiabatic demagnetization refrigerator↗