Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Self-scanned anode array with a microchannel plate electron multiplier - The SSANACON

A photoelectron counting detector utilizing a 128-element linear self-scanned anode array to collect the output of a dual microchannel plate electron multiplier is described. The operation of the detector, its spatial resolution and detection efficiency, and radiation behavior are discussed. The low-noise detector was developed for the Mariner Jupiter/Saturn mission UV spectrometer, and offers a large dynamic range and count rate of 0.003 per anode-sec. It can measure simultaneously two spatially separated signals differing by more than six orders of magnitude in count rate.

Broadfoot, A. L.↗

eXTP: Enhanced X-Ray Timing and Polarimetry Mission

eXTP is a science mission designed to study the state of matter under extreme conditions of density, gravity and magnetism. Primary goals are the determination of the equation of state of matter at supra-nuclear density, the measurement of QED effects in highly magnetized star, and the study of accretion in the strong-field regime of gravity. Primary targets include isolated and binary neutron stars, strong magnetic field systems like magnetars, and stellar-mass and supermassive black holes. The mission carries a unique and unprecedented suite of state-of-the-art scientific instruments enabling for the first time ever the simultaneous spectral-timing-polarimetry studies of cosmic sources in the energy range from 0.5-30 keV (and beyond). Key elements of the payload are: the Spectroscopic Focusing Array (SFA) - a set of 11 X-ray optics for a total effective area of approx. 0.9 m(exp. 2) and 0.6 m(exp. 2) at 2 keV and 6 keV respectively, equipped with Silicon Drift Detectors offering less than 180 eV spectral resolution; the Large Area Detector (LAD) - a deployable set of 640 Silicon Drift Detectors, for a total effective area of approx. 3.4 m(exp. 2), between 6 and 10 keV, and spectral resolution better than 250 eV; the Polarimetry Focusing Array (PFA) - a set of 2 X-ray telescope, for a total effective area of 250 cm(exp. 2) at 2 keV, equipped with imaging gas pixel photoelectric polarimeters; the Wide Field Monitor (WFM) - a set of 3 coded mask wide field units, equipped with position-sensitive Silicon Drift Detectors, each covering a 90 degrees x 90 degrees field of view. The eXTP international consortium includes major institutions of the Chinese Academy of Sciences and Universities in China, as well as major institutions in several European countries and the United States. The predecessor of eXTP, the XTP mission concept, has been selected and funded as one of the so-called background missions in the Strategic Priority Space Science Program of the Chinese Academy of Sciences since 2011. The strong European participation has significantly enhanced the scientific capabilities of eXTP. The planned launch date of the mission is earlier than 2025.

X-ray astronomy↗

Mass reconstruction of heavy neutral leptons from stopped mesons

Heavy neutral leptons (HNLs), depending on their mass and mixing, can be efficiently produced in meson decays from the target or absorber in short- to medium-baseline accelerator neutrino experiments, leaving detectable signals through their decays inside the neutrino detectors. We show that the currently running ICARUS experiment at Fermilab can reconstruct the HNL mass and explore new HNL parameter space in the mass range of 70–190 MeV. The mass reconstruction is enabled by two ingredients: (i) simple two-body kinematics of HNL production from stopped kaon decays at the NuMI absorber, followed by HNL decay into a charged-lepton pair and neutrino at the detector, and (ii) high resolution of Liquid Argon Time Projection Chamber (LArTPC) detectors in reconstructing final state particles. Our mass reconstruction method is robust under realistic energy resolution and angular smearing of the charged leptons, and is applicable to any LArTPC detector. We also discuss the synergy between ICARUS and future facilities like DUNE near detector and PIP-II beam dump in probing the HNL parameter space. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

AXAF/Chandra Capabilities

I will show some examples of what can be done with AXAF/Chandra, whose mirror has a subarcsecond angular resolution and whose detectors include Charge-Coupled Devices (CCDs) and microchannel plates with available high spectral resolution gratings.

Markevitch, M.↗

Impact of selenium addition to the cadmium-zinc-telluride matrix for producing high energy resolution X-and gamma-ray detectors

Abstract Both material quality and detector performance have been steadily improving over the past few years for the leading room temperature radiation detector material cadmium-zinc-telluride (CdZnTe). However, although tremendous progress being made, CdZnTe still suffers from high concentrations of performance-limiting defects, such as Te inclusions, networks of sub-grain boundaries and compositional inhomogeneity due to the higher segregation coefficient of Zn. Adding as low as 2% (atomic) Se into CdZnTe matrix was found to successfully mitigate many performance-limiting defects and provide improved compositional homogeneity. Here we report record-high performance of Virtual Frisch Grid (VFG) detector fabricated from as-grown Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 ingot grown by the Traveling Heater Method (THM). Benefiting from superior material quality, we achieved superb energy resolution of 0.77% at 662 keV (as-measured without charge-loss correction algorithms) registered at room temperature. The absence of residual thermal stress in the detector was revealed from white beam X-ray topographic images, which was also confirmed by Infra-Red (IR) transmission imaging under cross polarizers. Furthermore, neither sub-grain boundaries nor their networks were observed from the X-ray topographic image. However, large concentrations of extrinsic impurities were revealed in as-grown materials, suggesting a high likelihood for further reduction in the energy resolution after improved purification of the starting material.

36 MATERIALS SCIENCE↗

Comparing Thermal Neutron Scintillators for Use With SiPM-Readout Detectors

Scintillator-based thermal neutron detectors for scientific scattering facilities offer an effective combination of large-area coverage and good spatial resolution. At Oak Ridge National Laboratory, silicon photomultiplier (SiPM)-readout Anger cameras using 6 Li glass scintillators have been developed, but the spatial resolution of these detectors is limited by the relatively low light yield of the glass. Recently, several brighter scintillator compositions with sufficient 6 Li concentration have emerged as promising candidates for higher-resolution imaging. Here, in this work, we evaluate five scintillator materials: GS20, LiF/ZnS:Ag, LiF/ZnO:Zn, LiI:Eu, and Cs 2 LiYCl 6 :Ce, each mounted on a SiPM Anger camera. For each scintillator, the neutron detection efficiency, spatial resolution, and count rate capabilities were measured and compared. Each of the new compositions achieved a spatial resolution better than 0.5 mm, compared to 0.66 mm for GS20, with LiI:Eu reaching the best value of 0.32 mm. Although these compositions improve the spatial resolution of the Anger camera, their longer pulse decay times limit their use in high count rate applications, and the camera’s hardware must be optimized for the different properties of the new scintillators.

Neutron detectors↗

A new waveform analysis technique to extract good energy and position resolution from a dual-axis duo-lateral position-sensitive detector

The dual-axis duo-lateral position-sensitive silicon detector was developed to detect charged particles with high quality position and energy resolution. When these detectors were used with conventional signal processing electronics, an empirically determined correction was used to improve energy resolution. In this work, the waveforms from the detector after preamplification are studied in detail to investigate position information contained in the waveforms. A 7.22 MeV/nucleon alpha particle beam was impinged directly on a masked dual-axis duo-lateral detector. Data obtained using a 228 Th alpha particle source was also used. Here, by studying the waveform characteristics that give rise to the position-dependent distortions, a new summed trigger analysis method has been developed to significantly improve linearity in position reconstruction without sacrificing energy resolution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Space-Borne Observations of Intense Gamma-Ray Flashes Above Thunderstorms

Intense millisecond flashes of MeV photons were discovered with the space-borne detectors of the Burst and Transient Source Experiment (BATSE) aboard the Compton Gamma-Ray Observatory (CGRO). These flashes originate at altitudes above at least 30 km, in order to be observable by the orbiting detectors. Over the entire CGRO mission, from 1991 until 2000, about 70 of these events were observed. Nearly all TGFs had short (millisecond) durations and sub-ms rise-times and fall-times, however a small fraction of them had longer timescales associated with them. Most were single pulses, but about a dozen had double pulses and a few had more than two pulses. The TGFs are observed in a photon-by-photon recording mode, with each photon from eight independent detectors being tagged to the nearest two microseconds in four energy channels. The TGFs show very hard spectra, in most cases there are more photons recorded above 300 keV than below. Several of the TGFs were also recorded by the thicker (but smaller area) spectroscopy detectors that provided improved spectral resolution than the large area detectors. The temporal and spectral characteristics of the events and the capabilities of the detectors will be described in more detail than the in the original paper. The association of TGFs with thunderstorms is primarily statistical; the TGFs show a strong correlation with the global distribution of lightning, as observed with recent satellites. There has also been an association based upon coincidences with spheric events, however, this association is debatable due to the high spherics rate and the non-directionality of the detectors. This talk gives an update of the BATSE observations of TGFs were published by the BATSE instrument team over ten years ago.

Fishman, Jerry↗

Small area silicon diffused junction X-ray detectors

The low-temperature performance of silicon diffused junction detectors in the measurement of low energy X-rays is reported. The detectors have an area of 0.04 sq cm and a thickness of 100 microns. The spectral resolutions of these detectors were found to be in close agreement with expected values, indicating that the defects introduced by the high-temperature processing required in the device fabrication were not deleteriously affecting the detection of low-energy X-rays. Device performance over a temperature range of 77 K to 150 K is given. These detectors were designed to detect low-energy X-rays in the presence of minimum ionizing electrons. The successful application of silicon-diffused junction technology to X-ray detector fabrication may facilitate the development of other novel silicon X-ray detector designs.

Walton, J. T.↗

Investigation of defects in melt and solution grown perovskite CsPbBr 3 single crystals

Recently, there has been considerable interest in x-ray and gamma ray detectors with large volume and high energy resolution that operate at room temperature. To improve detector energy resolution, the carrier mobility-lifetime product needs to be increased, and the electronic trap state concentration needs to be minimized. Defect concentrations in the part per billion range can alter the charge transport and carrier recombination lifetime. In this work, thermally stimulated current spectroscopy measurements were systematically carried out in bulk halide perovskite single crystals of CsPbBr 3 over a temperature range of 80–320 K. The origins and trap parameters of CsPbBr 3 crystals from the solution growth and melt growth procedures were determined and compared. Trap concentrations were ranged from 1 × 10 11 to 1 × 10 16 cm –3 . Appreciable detector performance was observed for CsPbBr3 crystals with trap concentrations less than 1 × 10 14 cm –3 . The comparison of spectral responses of crystal samples grown using two different methods shows that, after purification, solution-grown crystals are comparable to melt-grown crystals in terms of low defect concentration and improved detector performance. Finally, for an improved mobility-lifetime product and enhanced spectral response to high energy radiation from fissile materials, trap states in either type of a crystal ingot must be reduced closer to 10 11 cm –3 .

36 MATERIALS SCIENCE↗

An alpha particle instrument with alpha, proton, and X-ray modes for planetary chemical analyses

The interaction of alpha particles with matter is employed in a compact instrument that could provide rather complete in-situ chemical analyses of surfaces and thin atmospheres of extraterrestrial bodies. The instrument is a miniaturized and improved version of the Surveyor lunar instrument. The backscattering of alpha particles and (alpha, p) reactions provide analytical data on the light elements (carbon-iron). An X-ray mode that detects the photons produced by the alpha sources provides sensitivity and resolution for the chemical elements heavier than about silicon. The X-rays are detected by semiconductor detectors having a resolution between 150 and 250 eV at 5.9 keV. Such an instrument can identify and determine with good accuracy 99 percent of the atoms (except hydrogen) in rocks. For many trace elements, the detecting sensitivity is a few ppm. Auxiliary sources could be used to enhance the sensitivities for elements of special interest. The instrument could probably withstand the acceleration involved in semi-hard landings.

Economou, T. E.↗

High resolution decoding techniques and single-chip decoders for multi-anode microchannel arrays

While the pixel size in a standard multianode microchannel array (MAMA) photon-counting detector is determined by the spacing of the anode array, the factor most fundamentally limiting pixel resolution is the spacing of the channels in the microchannel plate. Detector resolution can be improved by means of digitization followed by a centroiding procedure. The decoding hardware and the techniques for enhanced pixel resolution are presently discussed with a view to the factors of speed and complexity. A single-chip CMOS gate-array implementation of the decoder is devised and compared with existing multichip decoders' performance.

Kasle, David B.↗

URSIES - An ultravariable resolution single interferometer echelle scanner.

Use of a Fabry-Perot interferometer in a Ramsay mount in tandem with an echelle Hilger monochromator with pinholes instead of slits. The instrument, URSIES, is enclosed within a pressure chamber filled with Freon. Photoelectric pulse counting techniques and pressure scanning are used to record the spectrum. This design has four basic advantages: (1) the resolution of the scanner is variable from 5.0 to 0.005 A, and the effective wavelength range is quite broad, from 3500 to 13,000 A; (2) a light gain of ten over conventional grating scanners at resolutions of 0.1 A or better is achieved; (3) very low levels of light from outside the wavelength passband reach the detector; for a resolution of 0.03 A at 6000 A this level is 5%; and (4) there are very low levels of scattered light from the pinholes when extended sources are observed. The scattered light from the instrument at the edge of the solar disk is found to be less than 1% from 4000 to 11,000 A. Measurements demonstrating these advantages are discussed.

Wyller, A. A.↗

Effect of Space Radiation on TES Detectors Performance

The Athena mission and its X-IFU instrument (X-ray Integral Field Unit) will be positioned at the Sun-Earth Lagrangian point L1, where it will be subject to solar wind (low flux plasma of 95% protons and 5% alpha particles) with energy below 0.1 MeV, and to galactic cosmic rays and solar flares (energetic protons, alpha particles, and electrons) with energies up to hundreds of MeV for protons and the GeV for heavier ions. Some of these particles will go through the satellite and hit the focal plane assembly and hence the detectors. These detectors will be TES (Transition-edge sensor) microcalorimeters, flown for the first time in such an environment. In order to ensure the performance of this type of detectors throughout the duration of such mission, it is critical to study the impact of the radiation on their behavior. Indeed, although a lot of reference material exist for semiconductor detectors such as CCDs, little is currently known about the impact of radiation on TES detectors. These energetic events could cause local heating or damage to the detectors and affect their performance. In this work, we describe how we designed a test campaign to assess the impact of L1 radiation on TES detectors for Athena/X-IFU-like missions and present the results of the tests. Analyses includes assessing changes in the pulse shapes and energy resolution of the detectors measured at 55 mK after several radiation dose steps performed at 4 K.

Sophie Beaumont↗

Cesium lead bromide semiconductor radiation detectors: crystal growth, detector performance and polarization

Cesium lead bromide (CsPbBr 3 ) is an upcoming semiconductor radiation detector that has the potential to match the detection properties of cadmium zinc telluride (CZT) and thallium bromide (TlBr). In this paper, we report on CsPbBr 3 gamma detectors with an uncorrected energy resolution of 2% at 662 keV with photopeak-to-Compton ratios as high as 14.3 and hole mobility-lifetime products (μτ h ) as high as 1.7 × 10 –2 cm 2 V –1 . Furthermore, we demonstrate that the processes employed for material purification and crystal growth of high-performing devices are scalable, and large (up to 65 mm in diameter) ultrahigh purity CsPbBr 3 crystals have been successfully grown. Furthermore by using optimized growth conditions and detector fabrication processes, we were able to mitigate the polarization problem where it was revealed that the polarization process is highly dependent on the crystal quality and the electric field direction with respect to the orientation of the crystal.

30 DIRECT ENERGY CONVERSION↗

Lead and uranium group abundances in cosmic rays

The importance of Lead and Uranium group abundances in cosmic rays is discussed in understanding their evolution and propagation. The electronic detectors can provide good charge resolution but poor data statistics. The plastic detectors can provide somewhat better statistics but charge resolution deteriorates. The extraterrestrial crystals can provide good statistics but with poor charge resolution. Recent studies of extraterrestrial crystals regarding their calibration to accelerated uranium ion beam and track etch kinetics are discussed. It is hoped that a charge resolution of two charge units can be achieved provided an additional parameter is taken into account. The prospects to study abundances of Lead group, Uranium group and superheavy element in extraterrestrial crystals are discussed, and usefulness of these studies in the light of studies with electronic and plastic detectors is assessed.

Yadav, J. S.↗

Bevalac studies of magnet Cerenkov spectroscopy

The attempt was made to identify the various contributions to the velocity resolution of Cerenkov detectors such as might be used in Astromag, to measure the magnitude of these contributions and assess their effect on the mass resolution of an isotope spectrometer for Astromag, and to perform Bevalac tests of magnet/Cerenkov spectroscopy. A first version of a new 5 in. photomultiplier tube was also tested that is designed for use in large magnetic fields.

Source record↗