Search NASA⌕ Search

SEARCH · Search NASA

Results for “dosing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Development of a Reference Dose for Perchlorate: Current Issues and Status

The perchlorate anion (ClO4) is typically manufactured as the ammonium salt. The most common use of ammonium perchlorate is in the aerospace program as a component of solid rocket fuel. The perchlorate anion is exceedingly stable under environmental conditions and has been found in ground and surface waters in CA, NV, UT, AZ, TX, AK, NY, MD, WV and FL. The National Center for Environmental Assessment (NCEA) of the U.S. Environmental Protection Agency (US EPA) is in the process of developing an oral reference dose (RfD) for perchlorate. An oral RfD is a body-weight-adjusted dose that can be consumed daily over an entire lifetime with the expectation of no adverse health effects. Once developed, the new RfD will be used by US EPA as the basis of a safe-drinking-water level (SDWL) guideline. US EPA and regional regulatory agencies will then jointly or separately propose clean-up action levels for ground and surface waters at contaminated sites. The toxicological database on CIO4- as of March 1997 was determined by an expert peer-review panel to be inadequate for the purpose of deriving an oral RfD. For example, little or no experimental data existed on the subchronic, reproductive, or developmental toxicity of perchlorate. To fill gaps in the toxicological database, eight animal studies were designed by a government-industry consortium that included US EPA and AFRL. These studies were performed in 1997-1998. It has been known for many years that in the thyroid, high doses of perchlorate block the function of iodide by competing for iodide binding sites. Perchlorate was used in the 1950s-60s as a treatment for Graves' disease (a hyperthyroid condition). Because of what was already known about the pharmacological mode of action of perchlorate, specific concerns addressed in the design of the recent animal studies included the potential for developmental toxicity, notably neurological development. Upon review of complete study reports from four of the studies and incomplete data from the other two, US EPA/NCEA issued a document in December 1998 stating that the critical effects were hormone and histology data from the neurodevelopmental/behavioral toxicity study that had been performed in rats; an RfD was proposed based upon the observation of thyroid-follicular-cell hypertrophy in the 5-day-old pups (PND) of dams given perchlorate in drinking water at 0.1 mg/kg-day (the lowest dose tested) in this study. US EPA/NCEA also focused attention on a nonsignificant increase in motor activity observed in 14-day-old male pups in the same study at the same dose. In February 1999, a public workshop was convened at which an external peer-review panel determined that there was still insufficient data to support the development of a RfD. Additional studies were recommended. Since that time a clinical study revealed significant depression of thyroidal uptake of iodide in volunteers receiving potassium perchlorate at 10 mg/day for 14 days. Follow-up studies currently underway include a pathology working-group review of histology slides from the all of the previous studies, a motor activity study similar to the first behavioral study, an additional immunotoxicity study, male and female rat kinetic studies, a hormone interlaboratory study, and an effects study for thyroid and brain in developing rats. These studies are expected to be complete by mid-2000. A clinical study is planned to determine inhibition of iodide uptake and kinetic parameters in humans following 14-day perchlorate ingestion. The kinetics studies will provide data for developing physiologically based pharmacokinetic (PBPK) models for rats and humans needed to establish the RfD.

Pleus, R. C.↗

Absorbed Dose Determination Using Experimental and Analytical Predictions of X-Ray Spectra

Electron beam welding in a vacuum is a technology that NASA is investigating as a joining technique for manufacture of space structures. This investigation characterizes the x-ray environment due to operation of an in-vacuum electron beam welding tool and provides recommendations for adequate shielding for astronauts performing the in-vacuum electron beam welding. NASA, in a joint venture with the Russian Space Agency, was scheduled to perform a series of welding in space experiments on board the U.S. Space Shuttle. This series of experiments was named the international space welding experiment (ISWE). The hardware associated with the ISWE was leased to NASA by the Paton Welding Institute (PWI) in Ukraine for ground-based welding experiments in preparation for flight. Two ground tests were scheduled, using the ISWE electron beam welding tool, to characterize the radiation exposure to an astronaut during the operation of the ISWE. These radiation exposure tests used thermoluminescence dosimeters (TLD's) shielded with material currently used by astronauts during extravehicular activities to measure the radiation dose. The TLD's were exposed to x-ray radiation generated by operation of the ISWE in-vacuum electron beam welding tool. This investigation was the first known application of TLD's to measure absorbed dose from x rays of energy less than 10 keV. The ISWE hardware was returned to Ukraine before the issue of adequate shielding for the astronauts was completely verified. Therefore, alternate experimental and analytical methods were developed to measure and predict the x-ray spectral and intensity distribution generated by ISWE electron beam impact with metal. These x-ray spectra were normalized to an equivalent ISWE exposure, then used to calculate the absorbed radiation dose to astronauts. These absorbed dose values were compared to TLD measurements obtained during actual operation of the ISWE in-vacuum electron beam welding tool. The calculated absorbed dose values were found to be in agreement with the measured TLD values.

Edwards, D. L.↗

Effects of methiothepin on changes in brain serotonin release induced by repeated administration of high doses of anorectic serotoninergic drugs

We previously observed, using in vivo microdialysis, that the potassium-evoked release of frontocortical serotonin (5-HT) is suppressed after rats receive high doses (30 mg/kg, i.p., daily for 3 days) of fluoxetine, a selective blocker of 5-HT reuptake. We now describe similar impairments in 5-HT release after repeated administration of two other 5-HT uptake blockers, zimelidine and sertraline (both at 20 mg/kg, i.p. for 3 days) as well as after dexfenfluramine (7.5 mg/kg, i.p. daily for 3 days), a drug which both releases 5-HT and blocks its reuptake. Doses of these indirect serotonin agonists were about 4-6 times the drug's ED50 in producing anorexia, a serotonin-related behavior. In addition, methiothepin (20 microM), a non-selective receptor antagonist, locally perfused through the dialysis probe 24 h after the last drug injection, enhanced K(+)-evoked release of 5-HT at serotoninergic nerve terminals markedly in control rats and slightly in rats treated with high doses of dexfenfluramine or fluoxetine. On the other hand, pretreatment with methiothepin (10 mg/kg, i.p.) one hour before each of the daily doses of fluoxetine or dexfenfluramine given for 3 days, totally prevented the decrease in basal and K(+)-evoked release of 5-HT. Finally, when methiothepin was injected systemically the day before the first of 3 daily injections of dexfenfluramine, it partially attenuated the long-term depletion of brain 5-HT and 5-HIAA levels induced by repeated administration of high doses of dexfenfluramine. These data suggest that drugs which bring about the prolonged blockade of 5-HT reuptake - such as dexfenfluramine and fluoxetine - can, by causing prolonged increases in intrasynaptic 5-HT levels as measured by in vivo microdialysis, produce receptor-mediated long-term changes in the processes controlling serotonin levels and dynamics.

NASA Discipline Regulatory Physiology↗

Instrumentation for investigation of the depth-dose distribution by the Liulin-5 instrument of a human phantom on the Russian segment of ISS for estimation of the radiation risk during long term space flights

Described is the Liulin-5 experiment and instrumentation, developed for investigation of the space radiation doses depth distribution in a human phantom on the Russian Segment of the International Space Station (ISS). Liulin-5 experiment is a part of the international project MATROSHKA-R on ISS. The experiment MATROSHKA-R is aimed to study the depth dose distribution at the sites of critical organs of the human body, using models of human body-anthropomorphic and spherical tissue-equivalent phantoms. The aim of Liulin-5 experiment is long term (4-5 years) investigation of the radiation environment dynamics inside the spherical tissue-equivalent phantom, mounted in different places of the Russian Segment of ISS. Energy deposition spectra, linear energy transfer spectra, flux and dose rates for protons and the biologically-relevant heavy ion components of the galactic cosmic radiation will be measured simultaneously with near real time resolution at different depths of the phantom by a telescope of silicon detectors. Data obtained together with data from other active and passive dosimeters will be used to estimate the radiation risk to the crewmembers, verify the models of radiation environment in low Earth orbit, validate body transport model and correlate organ level dose to skin dose. Presented are the test results of the prototype unit. The spherical phantom will be flown on the ISS in 2004 year and Liulin-5 experiment is planned for 2005 year. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

Cosmic Radiation↗

M-BAND Analysis of Chromosome Aberration In Human Epithelial Cells exposed to Gamma-ray and Secondary Neutrons of Low Dose Rate

High-energy secondary neutrons, produced by the interaction of galactic cosmic rays with the atmosphere, spacecraft structure and planetary surfaces, contribute to a significant fraction to the dose equivalent in crew members and passengers during commercial aviation travel, and astronauts in space missions. The Los Alamos Nuclear Science Center (LANSCE) neutron facility's "30L" beam line is known to generate neutrons that simulate the secondary neutron spectrum of the Earth's atmosphere at high altitude. The neutron spectrum is also similar to that measured onboard spacecraft like the MIR and the International Space Station (ISS). To evaluate the biological damage, we exposed human epithelial cells in vitro to the LANSCE neutron beams at an entrance dose rate of 2.5 cGy/hr or gamma-ray at 1.7cGy/hr, and assessed the induction of chromosome aberrations that were identified with mBAND. With this technique, individually painted chromosomal bands on one chromosome allowed the identification of inter-chromosomal aberrations (translocation to unpainted chromosomes) and intra-chromosomal aberrations (inversions and deletions within a single painted chromosome). Compared to our previous results for gamma-rays and 600 MeV/nucleon Fe ions of high dose rate, the neutron data showed a higher frequency of chromosome aberrations. However, detailed analysis of the inversion type revealed that all of the three radiation types in the study induced a low incidence of simple inversions. The low dose rate gamma-rays induced a lower frequency of chromosome aberrations than high dose rate gamma-rays, but the inversion spectrum was similar for the same cytotoxic effect. The distribution of damage sites on chromosome 3 for different radiation types will also be discussed.

Hada, M.↗

Foods for a Mission to Mars: Investigations of Low-Dose Gamma Radiation Effects

Food must be safe, nutritious, and acceptable throughout a long duration mission to maintain the health, well-being, and productivity of the astronauts. In addition to a developing a stable pre-packaged food supply, research is required to better understand the ability to convert edible biomass into safe, nutritious, and acceptable food products in a closed system with many restrictions (mass, volume, power, crew time, etc.). An understanding of how storage conditions encountered in a long-term space mission, such as elevated radiation, will impact food quality is also needed. The focus of this project was to contribute to the development of the highest quality food system possible for the duration of a mission, considering shelf-stable extended shelf-life foods, bulk ingredients, and crops to be grown in space. The impacts of space-relevant radiation doses on food, bulk ingredient, and select candidate crop quality and antioxidant capacity were determined. Interestingly, increasing gamma-radiation doses (0 to 1000 Gy) did not always increase dose-related effects in foods. Intermediate radiation doses (10 to 800Gy) often had significantly larger impact on the stability of bulk ingredient oils than higher (1000Gy) radiation doses. Overall, most food, ingredient, and crop systems investigated showed no significant differences between control samples and those treated with 3 Gy of gamma radiation (the upper limit estimated for a mission to Mars). However, this does not mean that all foods will be stable for 3-5 years, nor does it mean that foods are stable to space radiation comprising more than gamma rays.

Gandolph, J.↗

Silver Foam: A Novel Approach for Long-Term Passive Dosing of Biocide in Spacecraft Potable Water Systems

A spacecraft water disinfection system, suitable for extended length space exploration, should prevent or control the growth of microbes, prevent or limit biofilm formation, and prevent microbiologically influenced corrosion. In addition, the system should have minimal maintenance requirements, be chemically compatible with all materials in contact with the water, be safe for human consumption, and be suitable to be shared across international spacecraft platforms and mission architectures. Silver ions are a proven broad-spectrum potable water biocide under investigation for future exploration missions. The competing technology for dosing silver ions in future water systems is based on actively dosing the ions via electrolytic production. Several challenges with this approach have prompted additional investigations into alternative dosing techniques. Control-release technology is an attractive option for developing a high-reliability passive silver dosing device. This paper describes the development of a nanoparticle/polyurethane (NP/PU) composite foam for the controlled release of silver ions, and is intended to build upon the 2020 International Conference onEnvironmental Systems (ICES) paper number 128. This paper provides the technical background and performance results from the updated silver chloride (AgCl) NP/PU. The ultimate goal of the project is to develop a stable and reliable passive dosing silver ion release device for use in future spacecraft potable water systems.

Tesia D. Irwin↗

Silver Foam: A Novel Approach for Long-Term Passive-Dosing of Biocide in Spacecraft Potable Water Systems – Update 2022

A spacecraft water disinfection system suitable for extended length space exploration should meet a list of requirements. It should prevent or control the growth of microbes, prevent or limit biofilm formation, and prevent microbiologically influenced corrosion. In addition, the system should have minimal maintenance requirements, be chemically compatible with all materials in contact with the water, be safe for human consumption, and be suitable to be shared across international spacecraft platforms and mission architectures. Silver ions are a proven broad-spectrum potable water biocide under investigation for future exploration missions. The competing technology for dosing silver ions in future water systems is based on actively dosing the ions via electrolytic production. Several challenges with this approach have prompted additional investigations into alternative dosing techniques. Control-release technology is an attractive option for developing a high-reliability passive silver dosing device. This paper describes the continued development of a nanoparticle/polyurethane (NP/PU) composite foam for the controlled release of silver ions and is intended to build upon previously published work. This paper provides the technical background and performance results (wash testing and ongoing long-term silver ion release testing) from the silver chloride (AgCl) NP/PU composite foams. The goal of the project is to develop a stable and reliable passive-dosing silver ion release device for use in future spacecraft potable water systems.

Tesia D Irwin↗

Silver Foam: A Novel Approach for Long-Term Passive Dosing of Biocide in Spacecraft Potable Water Systems – Update 2023

A spacecraft water disinfection system, suitable for extended length space exploration, should prevent or control the growth of microbes, prevent or limit biofilm formation, and prevent microbiologically influenced corrosion. In addition, the system should have minimal maintenance requirements, be chemically compatible with all materials in contact with the water, be safe for human consumption, and be suitable to be shared across international spacecraft platforms and mission architectures. Silver ions are a proven broad-spectrum potable water biocide under investigation for future exploration missions. The competing technology for dosing silver ions in future water systems is based on actively dosing the ions via electrolytic production. Several challenges with this approach have prompted additional investigations into alternative dosing techniques. Control-release technology is an attractive option for developing a high-reliability passive silver dosing device. This paper describes the continued development of a nanoparticle/polyurethane (NP/PU) composite foam for the controlled release of silver ions and is intended to build upon the 2022 International Conference on Environmental Systems (ICES) paper number 97. This paper provides the technical background and performance test results (ongoing long-term silver ion release testing and product variability testing) from the silver chloride (AgCl) NP/PU composite foams. The ultimate goal of the project is to develop a stable and reliable passive dosing silver ion release device for use in future spacecraft potable water systems.

Tesia D. Irwin↗

Silver Foam: A Novel Approach for Long-Term Passive Dosing of Biocide in Spacecraft Potable Water Systems – Update 2024

A spacecraft water disinfection system, suitable for extended length space exploration, should prevent or control the growth of microbes, prevent or limit biofilm formation, and prevent microbiologically influenced corrosion. In addition, the system should have minimal maintenance requirements, be chemically compatible with all materials in contact with the water, be safe for human consumption, and be suitable to be shared across international spacecraft platforms and mission architectures. Silver ions are a proven broad-spectrum potable water biocide under investigation for future exploration missions. The competing technology for dosing silver ions in future water systems is based on actively dosing the ions via electrolytic production. Several challenges with this approach have prompted additional investigations into alternative dosing techniques. Control-release technology is an attractive option for developing a high-reliability passive silver dosing device. This paper describes the continued development of a nanoparticle/polyurethane (NP/PU) composite foam for the controlled release of silver ions and is intended to build upon the 2023 International Conference on Environmental Systems (ICES) paper number 251. This paper provides the technical background and performance results for the product variability testing and microbial check valve (MCV) testing of the silver chloride (AgCl) NP/PU composite foams, referred to as AgFoams. The ultimate goal of the project is to develop a stable and reliable passive dosing silver ion release device for use in future spacecraft potable water systems.

Tesia D Irwin↗

Real-Time Dose Prediction for Artemis Missions

As large solar energetic particle (SEP) events can add significant radiation dose to astronauts in a short period of time and even induce acute clinical responses during missions, they present a concern for manned space flight operation. To assist the operations team in modeling and monitoring organ doses and any possible acute radiation-induced risks to astronauts during SEP events in real time, ARRT (Acute Radiation Risks Tool) 1.0 has been developed and successfully tested for Artemis I mission. The ARRT 2.0 described in this work integrates an established SEP forecasting model – UMASEP-100, further enabling real-time dose prediction for the upcoming Artemis II and following missions. With the new module linking with UMASEP-100 outputs in real time, the total BFO doses of most significant events can be communicated at the time of onset and hours before the peak. This is based on a flux-dose formula identified from comparing UMASEP-100 results with transport calculation for the events during 1994-2013 and validated with events outside that period. ARRT 2.0 also shows capability to distinguish minor events from significant ones to screen false alarms that will cause disruptions for space activities. This improvement provides additional information for operational teams to make timely decisions in contingent scenarios of severe SEP events to mitigate radiation exposure.

S Hu↗

Real-Time Dose Prediction for Artemis Missions

As large solar energetic particle (SEP) events can add significant radiation dose to astronauts in a short period of time and even induce acute clinical responses during missions, they present a concern for manned space flight operation. To assist the operations team in modeling and monitoring organ doses and any possible acute radiation-induced risks to astronauts during SEP events in real time, ARRT (Acute Radiation Risks Tool) 1.0 has been developed and successfully tested for Artemis I mission. The ARRT 2.0 described in this work integrates an established SEP forecasting model – UMASEP-100, further enabling real-time dose prediction for the upcoming Artemis II and following missions. With the new module linking with UMASEP-100 outputs in real time, the total BFO doses of most significant events can be communicated at the time of onset and hours before the peak. This is based on a flux-dose formula identified from comparing UMASEP-100 results with transport calculation for the events during 1994-2013 and validated with events outside that period. ARRT 2.0 also shows capability to distinguish minor events from significant ones to screen false alarms that will cause disruptions for space activities. This improvement provides additional information for operational teams to make timely decisions in contingent scenarios of severe SEP events to mitigate radiation exposure.

Shaowen Hu↗

Lunar Nuclear Reactor Neutron Fluence and Gamma Dose Estimates

NASA aims to deploy a fission reactor on the lunar surface by 2030 to generate 100 kWe of power for at least 10 years without maintenance or refueling. To assess system and subsystem survivability according to those requirements, a model of the reactor pallet was created in the radiation transport code MCNP to determine the neutron fluences and gamma doses that the materials and systems would be exposed to. The model was based on the 2025 government design. The model indicated that the control drum motors, Brayton cycle engines, and pipes and valves would be exposed to neutron fluences of 1×10 15 – 1×10 16 n/cm 2 per year and gamma doses ranging from 10 to 500 Mrad per year. The electronics box housing the instrumentation and control elements is expected to receive 1×10 14 – 1×10 15 n/cm 2 per year and gamma doses in the range of 1–5 Mrad per year. These doses necessitate that the control drum motors, Brayton cycle engines, valve components, control electronics, and other components be radiation-hardened (>10 16 n/cm 2 and >10 Mrad gamma dose) or additionally shielded to survive the 10-year lunar mission.

Radiation-Hardened Materials↗

AFRRI TRIGA Reactor Neutron and Gamma Dose Characterization Preliminary Results

Integral Experiment Request (IER) 484 is part of a series of dose characterization and nuclear accident dosimeter (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). The Armed Forces Radiobilogy Research Institute (AFRRI) 1.1 MW Training, Research, Isotopes, General Atomics (TRIGA) Mark-F reactor is the third facility to undergo a dose study to establish reference dose values. A preliminary measurement was performed earlier this year, where a variety of foils were irradiated and activation gamma rays were measured using a high-purity germanium (HPGe) detector. The data was taken and analyzed to calculate the neutron spectrum in the irradiation facility. This paper will present preliminary results of the neutron dose measured. The characterization of the AFRRI dose field is planned in August.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods to Track Effective Doses from Airborne Radioactive Emissions for Compliance with 40 CFR 61, SUBPART H

US Department of Energy national laboratories can play an integral role in not only the advancement of science but also in the treatment of various medical conditions through research and development activities conducted at radioisotope production facilities. Here, a project has been underway at Oak Ridge National Laboratory since 2016 whose mission is to produce and supply the radioisotope 227 Ac, which is used in a radiopharmaceutical developed to treat certain types of prostate cancer and bone metastases. Production activities result in the environmental release of airborne radioactive emissions, which are governed by Clean Air Act regulations described in 40 CFR Part 61, Subpart H. Stack 3039, the source that emits radioactive effluents from 227 Ac production, is subject to additional requirements outlined in American National Standards Institute (ANSI) N13.1-1969 due to its grandfathered status. Radioactive emissions are limited to levels below those that would cause annual compliance dose standards for members of the public to be exceeded and stack 3039 to lose its grandfathered status. To allow for maximum production of 227 Ac without exceeding relevant dose limits, monthly tracking of project emissions and resulting CAP88-PC modeled effective doses to a maximally exposed individual have been implemented. Four years of tracking data were compiled and analyzed to identify additional methods that could be used to estimate project doses more frequently, potentially further optimizing 227 Ac production while maintaining compliance with applicable regulations.

atmospheric emissions↗

Recommendations for Dose Selection for Adolescent Patients in Relevant Adult Oncology Clinical Trials

Our research supported the dose selection recommendations for adolescents in the US Food and Drug Administration (FDA) Guidance on Inclusion of Adolescent Patients in Adult Oncology Clinical Trials. The FDA Guidance states that for drugs administered as a flat dose in adults and data showing no clinically meaningful effect of body size on drug exposure and toxicity in adults, a minimum body weight threshold may need to be defined to prevent adolescents who have a lower body weight from exceeding adult exposures. Our review of adult population pharmacokinetic analyses of new molecular entities approved for oncology between January 2015 and March 2021 suggested that 40 kg (the approximate median body weight of a 12-year-old) is generally the lower end of the body weight range that has no clinically relevant effect on drug pharmacokinetics or safety. In conclusion, the minimum body weight threshold and selection of an appropriate dose for adolescents in relevant adult oncology clinical trials should ultimately be determined based on available data on pharmacokinetics or pharmacodynamics of the investigational drug with consideration of body size effect on drug exposure, toxicity, and efficacy data (if available), the therapeutic index of the drug, and dose- and exposure-response relationships in adults.

60 APPLIED LIFE SCIENCES↗

Shutdown dose rate analysis with the Shift Monte Carlo radiation transport code and modular verification workflow

Calculation of the shutdown dose rate is crucial for safe fusion reactor operations. The Rigorous-two-step (R2S) method is a method that requires connected neutron transport, activation, and gamma transport. Shift has integrated variance reduction with a deterministic solver Denovo, supports multiple geometry formats, and is scalable. These features make it an attractive transport solver choice for an R2S workflow. An R2S workflow for the Shift Monte Carlo code is developed and compared to the existing Oak Ridge National Laboratory Shutdown Dose Rate Code Suite (ORCS) workflow. Also, a Python framework for integrating two R2S workflows is developed to mix and match each step in the R2S workflow for improved collaboration and verification experience. In this study, results show that the Shift-Denovo R2S workflow and the ORCS workflow calculate the shutdown dose rate of the ITER Shutdown Dose Rate benchmark problem with an average relative error of 2.285%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Primer on Dose-Response Data Modeling in Radiation Therapy

An overview of common approaches used to assess a dose response for radiation therapy–associated endpoints is presented, using lung toxicity data sets analyzed as a part of the High Dose per Fraction, Hypofractionated Treatment Effects in the Clinic effort as an example. Each component presented (eg, data-driven analysis, dose-response analysis, and calculating uncertainties on model prediction) is addressed using established approaches. Specifically, the maximum likelihood method was used to calculate best parameter values of the commonly used logistic model, the profile-likelihood to calculate confidence intervals on model parameters, and the likelihood ratio to determine whether the observed data fit is statistically significant. The bootstrap method was used to calculate confidence intervals for model predictions. Correlated behavior of model parameters and implication for interpreting dose response are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗