Search NASA⌕ Search

SEARCH · Search NASA

Results for “duct system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Pennsylvania and Delaware Energy Code Field Studies (Final Technical Report (FTR)

Led by Northeast Energy Efficiency Partnerships (NEEP) in partnership with Performance Systems Development (PSD), the project aimed to conduct energy code compliance field studies for single-family residential buildings in Pennsylvania and Delaware, as well as multifamily and commercial buildings in Pennsylvania. Using U.S. Department of Energy (DOE) approved methodologies, trained field teams conducted on-site observations and testing to document compliance with key energy efficiency measures, including building envelope insulation, air sealing, duct leakage, windows, and mechanical systems. Data from these studies would then be analyzed to identify construction trends and compliance gaps. The goals included published baseline data for each study, and a training roadmap tailored to each state’s needs. This roadmap would have guided outreach and training for builders, code officials, and other stakeholders on the specific code requirements that offered the greatest opportunity for improvement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exit plane H2O concentration measurements correlated with OH PLIF near-injector mixing measurements for scramjet flows

Mixing and combusting high enthalpy flows, similar to those encountered in scramjet engines, were investigated using a shock tunnel to produce the flow in conjunction with non-intrusive optical diagnostics which monitored the performance of two injector configurations. The shock tunnel is configured to produce Mach 3 flow and stagnation enthalpies corresponding to flight equivalent Mach numbers between 7 and 11. A pulsed hydrogen injection capability and interchangeable injector blocks provide a means of examining high speed, high enthalpy reacting flows. Planar laser induced fluorescence (PLIF) of OH molecules in the near injector region produced images which show the combusting and mixing zones for the reacting flow. Line-of-sight exit plane measurement of water concentration and temperature were used to provide a unique method of monitoring exit plane products. These results demonstrated that a velocity matched axial injection system produced a fuel jet that lifted off the floor of the duct. Mixing was observed to increase for this system as a velocity mismatch was introduced. Comparison of exit plane water concentrations for a wall jet injection system and a velocity matched injection system indicated similar mixing performance but an accurate pressure measurement is necessary to further validate the result. In addition, exit plane measurements indicated an approximate steady-state condition was achieved during the 1 to 2 ms test times.

Parker, T. E.↗

Development and Demonstration of Active Noise Control Concepts

This report details design methods for and feasibility of an Active Noise Control (ANC) system using flush-wall-mounted sensors and actuators to reduce turbofan engine rotor-stator interaction noise. ANC concepts capable of suppressing discrete-tone spinning modes containing several cut-on radial mode were identified, developed analytically, and evaluated. Separate ANC systems that suppressed at least three radial modes in a cylindrical inlet duct and three radial modes in an exhaust annulus were developed. These designs resulted in inlet duct and exhaust duct tests that were performed at NASA on the 4-ft ANC Fan in the NASA Glenn AAPL facility. Effective suppression of 2-BPF spinning mode m = 2 tone noise was achieved over a range of fan speeds 1800 to 2450 rpm, where up to 4 radials were present. In the inlet duct, up to 12 dB reduction was obtained for 3 radial modes, and up to 4 dB was obtained with 4 radial modes. In the exhaust duct, up to 15 dB PWL reduction was obtained with either two or three radial modes present. Thus, the ability to suppress multiple radial modes for tones in both the inlet and exhaust ducts has been successfully demonstrated. Implications of ANC system design requirements on installation and system integration issues for ANC systems capable of suppressing higher order radial mode content when applied to a 767 using twin CF6 engines were evaluated analytically. The analytical results indicated an ANC system must be part of an integrated design to be effective.

Kraft, R.↗

Lightweight Exhaust Manifold and Exhaust Pipe Ducting for Internal Combustion Engines

An improved exhaust system for an internal combustion gasoline-and/or diesel-fueled engine includes an engine exhaust manifold which has been fabricated from carbon- carbon composite materials in operative association with an exhaust pipe ducting which has been fabricated from carbon-carbon composite materials. When compared to conventional steel. cast iron. or ceramic-lined iron paris. the use of carbon-carbon composite exhaust-gas manifolds and exhaust pipe ducting reduces the overall weight of the engine. which allows for improved acceleration and fuel efficiency: permits operation at higher temperatures without a loss of strength: reduces the "through-the wall" heat loss, which increases engine cycle and turbocharger efficiency and ensures faster "light-off" of catalytic converters: and, with an optional thermal reactor, reduces emission of major pollutants, i.e. hydrocarbons and carbon monoxide.

Northam, G. Burton↗

Fire-station solar-energy system--Kansas City, Missouri

Screen-walled, flat-plate air collectors are part of award-winning architectural design; concrete-box storage subsystem, domestic hot-water preheat tank, blowers, pumps, heat exchangers, ducting, controls, and plumbing complete solar system. Design provides half of space heating and 75 percent of heat for domestic hot-water for fire station. Report includes historical narrative of project along with detailed drawings, charts, and product literature.

Source record↗

Apparatuses and methods for generating carbon particles and exhaust gas used by gas turbine systems

Apparatuses for generating carbon particles and exhaust gas used by gas turbine systems are disclosed. One apparatus may include a decarbonization component combusting or reacting a mixture of a fuel and a mixing gas to generate the carbon particles and the exhaust gas and an exhaust conduit to receive the exhaust gas generated by the decarbonization component. The apparatus may also include a mixing duct in fluid communication with the exhaust conduit and the gas turbine system. The mixing duct may receive the exhaust gas and provide the exhaust gas to the gas turbine system to be used to produce a working fluid within the gas turbine system. The apparatus may further include a carbon particle collection component for receiving and storing the generated carbon particles.

Berry, Jonathan Dwight↗

Rotating Rake Mode Measurements Over Passive Treatment in a Ducted Fan

The NASA Glenn Research Center s Rotating Rake mode measurement system has been successful in measuring the modal content propagating in hardwall ducts. This paper proposes an extension of the Rotating Rake measurement and analysis technique to treated sections by developing basis functions based on wall impedance boundary conditions for flow conditions (i.e., constant duct area and Mach number) where the closed form analytical solution exists. Analytical equations developed to estimate mode power are incorporated. This method is verified by decomposing and analyzing radial pressure profiles generated numerically by the Eversman propagation code. Several modes, frequencies and impedances are evaluated. Data from a low-speed ducted fan with several different impedance conditions was acquired and reduced to determine the best fit to the data. Using the impedance boundary conditions result in better mode measurement solutions.

Sutliff, Daniel L.↗

Active Control of Fan Noise: Feasibility Study: Theoretical Analysis for Coupling of Active Noise Control Actuator Ring Sources to an Annular Duct with Flow - Volume 6

The objective of this effort is to develop an analytical model for the coupling of active noise control (ANC) piston-type actuators that are mounted flush to the inner and outer walls of an annular duct to the modes in the duct generated by the actuator motion. The analysis will be used to couple the ANC actuators to the modal analysis propagation computer program for the annular duct, to predict the effects of active suppression of fan-generated engine noise sources. This combined program will then be available to assist in the design or evaluation of ANC systems in fan engine annular exhaust ducts. An analysis has been developed to predict the modes generated in an annular duct due to the coupling of flush-mounted ring actuators on the inner and outer walls of the duct. The analysis has been combined with a previous analysis for the coupling of modes to a cylindrical duct in a FORTRAN computer program to perform the computations. The method includes the effects of uniform mean flow in the duct. The program can be used for design or evaluation purposes for active noise control hardware for turbofan engines. Predictions for some sample cases modeled after the geometry of the NASA Lewis ANC Fan indicate very efficient coupling in both the inlet and exhaust ducts for the m = 6 spinning mode at frequencies where only a single radial mode is cut-on. Radial mode content in higher order cut-off modes at the source plane and the required actuator displacement amplitude to achieve 110 dB SPL levels in the desired mode were predicted. Equivalent cases with and without flow were examined for the cylindrical and annular geometry, and little difference was found for a duct flow Mach number of 0.1. The actuator ring coupling program will be adapted as a subroutine to the cylindrical duct modal analysis and the exhaust duct modal analysis. This will allow the fan source to be defined in terms of characteristic modes at the fan source plane and predict the propagation to the arbitrarily-located ANC source plane. The actuator velocities can then be determined to generate the anti-phase mode. The resulting combined fan source/ANC pressure can then be calculated at any desired wall sensor position. The actuator velocities can be determined manually or using a simulation of a control system feedback loop. This will provide a very useful ANC system design and evaluation tool.

Kraft, R. E.↗

Coupling of Low Speed Fan Stator Vane Unsteady Pressures to Duct Modes: Measured versus Predicted

Uniform-flow annular-duct Green's functions are the essential elements of the classical acoustic analogy approach to the problem of computing the noise generated by rotor-stator interaction inside the fan duct. This paper investigates the accuracy of this class of Green's functions for predicting the duct noise levels when measured stator vane unsteady surface pressures are used as input to the theoretical formulation. The accuracy of the method is evaluated by comparing the predicted and measured acoustic power levels for the NASA 48 inch low speed Active Noise Control Fan. The unsteady surface pressures are measured,by an array of microphones imbedded in the suction and pressure sides of a single vane, while the duct mode levels are measured using a rotating rake system installed in the inlet and exhaust sections of the fan duct. The predicted levels are computed using properly weighted integrals of measured surface pressure distribution. The data-theory comparisons are generally quite good particularly when the mode cut-off criterion is carefully interpreted. This suggests that, at least for low speed fans, the uniform-flow annular-duct Green's function theory can be reliably used for prediction of duct mode levels if the cascade surface pressure distribution is accurately known.

Sutliff, Daniel L.↗

Study of an engine flow diverter system for a large scale ejector powered aircraft model

Requirements were established for a conceptual design study to analyze and design an engine flow diverter system and to include accommodations for an ejector system in an existing 3/4 scale fighter model equipped with YJ-79 engines. Model constraints were identified and cost-effective limited modification was proposed to accept the ejectors, ducting and flow diverter valves. Complete system performance was calculated and a versatile computer program capable of analyzing any ejector system was developed.

Springer, R. J.↗

Mid Infra-Red Laser Sensor for Continuous Sulfur Trioxide Monitoring to Improve Coal-Fired Power Plant Performance during Flexible Operations

During the course of this project, we performed exhaustive research and development of SO3/H2SO4 sensing technology for coal-fired power plant applications (Figure 1). The development culminated in a successful field campaign of a prototype continuous real-time H2SO4 monitor at a coal-fired power plant (TRL 6) accomplishing the primary goal of the project. The developed sensors utilize tunable laser absorption spectroscopy (TLAS) operating in the mid-infrared (Mid-IR) wavelength region, which is the so-called “molecular fingerprint” region. Systems operating in the Mid-IR have orders of magnitude more sensitivity than systems operating at shorter wavelengths, such as near-infrared (NIR). However, NIR systems are more widespread due to more mature supporting technology (e.g., fiber optics, optical components, etc.). In this project, we not only produced a specific Mid-IR sensor, we also advanced Mid-IR sensor technology in general through the development and demonstration of such supporting technology. In this project, we also developed proprietary broad tuning lasers enabling the ability to effectively measure SO3, H2SO4, H2O, and SO2. Different molecular species have unique spectral signatures that can be probed with lasers operating at different wavelengths. Standard TLAS uses relatively narrow wavelength tuning distributed feedback (DFB) lasers, which can typically only target a single species with narrow features, and are not appropriate for species with broad features, such as SO3 or H2SO4. In contrast, by developing unique, broad-tuning laser technology, we were able to measure these species, as well as SO2 and H2O simultaneously. Furthermore, to enable real-time analysis at a power plant, we modified a commercially available heated gas cell to operate in the Mid-IR wavelength range and fiber coupled the lasers to enable remote delivery of the beams. To generate reference data (library spectra), our collaborators at the University of California Irvine (UCI) developed a catalytic SO3 generation facility. It is worth mentioning that representative H2SO4 and SO3 Mid-IR spectra are not a part of any publicly available database and the data generated under this project is a valuable resource in and of itself. In addition, based on the UCI study we determined that detection of SO3 is complicated by the very strong SO2 absorption. For that reason, we concentrated on H2SO4 detection. Since SO3 and H2SO4 exist in a flue gas in a state of equilibrium, which depends on temperature and humidity, by measuring water concentration and controlling the temperature of the gas cell, we developed an approach to determine SO3 concentration from the H2SO4 measurement. During the development phase of the project, we performed three testing campaigns at our collaborator’s FERCo flue gas facility with conditions representative of the coal-fired power plant (~ 40ppm SO3, 1700ppm to 2800 ppm SO2, 10% water) with the exception of particulate matter. After three test campaigns at FERCo we performed field testing at Harrison Power Station. The final system was mounted on a duct and measured H2SO4, SO2 and water. The tests were highly successful with a demonstrated real-time H2SO4 precision of 1 ppm with a 1 second update. Our collaborators at EPRI conducted an industry survey and determined that there is a very high interest for the SO3/H2SO4 monitoring in the power generation industry as well as in heavy industries in general. Furthermore, work performed by OptoKnowledge beyond the scope of this project under a synergistic DOE SBIR determined another approach to SO3 detection. We applied for Phase II on this SBIR for development a of versatile SO3/H2SO4 sensor but were not selected. We are currently looking for another opportunity to leverage all the technological advancements produced by this project including but not limited to the flue gas facility at UCI, the hardware and software developed, and relationships with FERCo, EPRI CEMTEK, and Harrison Station.

01 COAL, LIGNITE, AND PEAT↗

Numerical techniques in linear duct acoustics

Both finite difference and finite element analyses of small amplitude (linear) sound propagation in straight and variable area ducts with flow, as might be found in a typical turboject engine duct, muffler, or industrial ventilation system, are reviewed. Both steady state and transient theories are discussed. Emphasis is placed on the advantages and limitations associated with the various numerical techniques. Examples of practical problems are given for which the numerical techniques have been applied.

Baumeister, K. J.↗

Numerical techniques in linear duct acoustics - A status report

A review is presented covering both finite difference and finite element analysis of small amplitude (linear) sound propagation in straight and variable area ducts with flow, as might be found in a typical turbojet engine duct, muffer, or industrial ventilation system. Both 'steady' state and transient theories are discussed. Emphasis is placed on the advantages and limitations associated with the various numerical techniques. Examples of practical problems are given for which the numerical techniques have been applied.

Baumeister, K. J.↗

Fabrication of a graphite/epoxy composite leading edge for laminar flow control

Lockheed, under NASA contract, has recently completed the first phase of a program to evaluate laminar flow control concepts for transport aircraft. Achievement of laminar flow over a wing surface requires a system of slots, metering holes, ducts and pumps to be used to remove the turbulent air adjacent to the surface. This requirement poses severe restrictions on conventional metallic structure. Graphite/epoxy composite with its unique properties appears to be the material that might solve the very complex structural problems associated with a laminar flow control aircraft. A six-foot span graphite/epoxy test article incorporating provisions for leading edge cleaning, deicing and laminar flow control was designed, fabricated and tested.

Beall, R. T.↗

Computer Software Management and Information Center

Computer programs for passive anti-roll tank, earth resources laboratory applications, the NIMBUS-7 coastal zone color scanner derived products, transportable applications executive, plastic and failure analysis of composites, velocity gradient method for calculating velocities in an axisymmetric annular duct, an integrated procurement management system, data I/O PRON for the Motorola exorcisor, aerodynamic shock-layer shape, kinematic modeling, hardware library for a graphics computer, and a file archival system are documented.

Source record↗

Calculation of flow about posts and powerhead model

A three dimensional analysis of the non-uniform flow around the liquid oxygen (LOX) posts in the Space Shuttle Main Engine (SSME) powerhead was performed to determine possible factors contributing to the failure of the posts. Also performed was three dimensional numerical fluid flow analysis of the high pressure fuel turbopump (HPFTP) exhaust system, consisting of the turnaround duct (TAD), two-duct hot gas manifold (HGM), and the Version B transfer ducts. The analysis was conducted in the following manner: (1) modeling the flow around a single and small clusters (2 to 10) of posts; (2) modeling the velocity field in the cross plane; and (3) modeling the entire flow region with a three dimensional network type model. Shear stress functions which will permit viscous analysis without requiring excessive numbers of computational grid points were developed. These wall functions, laminar and turbulent, have been compared to standard Blasius solutions and are directly applicable to the cylinder in cross flow class of problems to which the LOX post problem belongs.

Anderson, P. G.↗

Removing Welding Fumes

Portable exhaust duct for machining and welding shops removes oil mist, dust, smoke, and fumes. Duct used with shop exhaust system, inlets of which placed at various convenient locations in shop floor. Flanged connector on underside of wheeled base links flexible tube to exhaust system under floor. Made especially for welding in room with low ceiling.

Moore, Lloyd J.↗