Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic solar control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

258 records · Page 15

Reducing Cost of Chlorinated Volatile Organic Compound Remediation by Transitioning from Active to Passive Soil Vapor Extraction - 20157

Areas of high chlorinated volatile organic compound (cVOC) contamination at the Savannah River Site (SRS) have been undergoing remediation via soil vapor extraction, sometimes coupled with thermal treatments to enhance extraction rates. These active systems are effective in removing large amounts of contaminant mass from the subsurface and mitigating the impacts to groundwater. However, as extraction rates decline, costs must be evaluated with respect to the benefit of continued active operation. A decision framework for identifying conditions when a transition to a more passive remediation is appropriate has been developed with state and federal regulatory agencies. Two remediation areas have recently been transitioned from active soil vapor extraction (ASVE) to passive soil vapor extraction (PSVE) at the SRS. Performance evaluation goals including plume stabilization, overall mass removal trends, environmental sustainability and costs were considered in transitioning from active remediation to passive technologies at both sites. At the Dynamic Underground Stripping (DUS) project at the M-Area Settling Basin, ASVE was combined with steam injection to extract cVOCs during active operations. Steam injection occurred from September 2005 to September 2009. DUS utilized 63 steam injection wells, 34 active vapor extraction wells, and 3 active soil vapor extraction units (SVEUs). Two active SVEUs had 60 horsepower blowers; the third had a 25-horsepower blower. Mass removal was closely tracked during DUS operations; over 181,437 kilograms (400,000 pounds) of cVOCs were removed while active steam injection occurred. After steaming was stopped, ASVE continued. The 34 active wells were evaluated in 2012. The ASVE wells were grouped into categories of high, medium, and low extraction rates. High producing wells remained connected to a single active SVEU. Low producing wells were abandoned, and the medium producing wells were transitioned to PSVE (Microblowers{sup TM}). Microblowers{sup TM} utilize a dedicated blower per well and are solar powered. This passive technology provides energy, maintenance, and operation costs savings while still providing an efficient reduction in cVOC migration to groundwater. In 2018, the remaining ASVE wells were evaluated again. The purpose of this testing was to identify which wells removed the most mass. An optimal well configuration was determined. The criteria to discontinue ASVE was removal of less than 18 kilograms (40 pounds) per week of cVOCs. After 3 months of shutdown (rebound conditions), 2.7 kilograms (5.9 pounds) of cVOCs per week were being removed. Data from the rebound test justified ending ASVE and transitioning wells with higher extraction rates to PSVE. Wells that had depleted the cVOC mass within their zone of influence were abandoned. Performance data from existing PSVE wells justified ending PSVE at wells with depleted extraction rates. Currently the system has 16 PSVE wells operating. Another ASVE system was being used to treat cVOC contaminated soil at the A-Area Miscellaneous Rubble Pile (AMRP) at SRS. System operation began in 2004, with 7 ASVE wells connected to a 60- horsepower blower. Mass removal rates and contaminant concentrations remained consistently low over the ASVE lifespan at AMRP. This indicated that mass removal was diffusion limited. With this data, the 7 ASVE wells were transitioned to PSVE in 2017. Twelve pressure monitoring points were also transitioned to PSVE wells. AMRP currently has 19 PSVE wells operating. Both transitions from active to passive remediation had concurrence from the United States Environmental Protection Agency and the South Carolina Department of Health and Environmental Control. These transitions ensure that only the necessary amount of energy is being exerted to remediate the environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Why are Lead Iodide‐Based Perovskite Precursor Inks Yellow?

A challenge faced by metal halide perovskite (MHP) photovoltaics is scaling up solution deposition processes to realize rapid and inexpensive manufacturing. The challenge lies in completely understanding and controlling solution speciation, nucleation, and self-assembly of iodoplumbate complexes during solvent evaporation as the liquid transforms into gels and solids. An accurate description of solution species, at all points in the transformation, is a prerequisite to design robust and reliable processes. Here, in this study, the common assumption that initial monoplumbate solution species typically invoked (e.g., [PbI 6 ] 4− ) are certainly not the origin of optical absorbance at >400 nm wavelengths is disproved, as are many large particles of common “intermediate” iodoplumbate phases with face- or edge-sharing connectivity. Instead, a new perspective is offered, involving (partially) corner-sharing iodo(poly)plumbates (>1 Pb 2+ per complex) that experience highly dynamic chemical environments. It is outlined how the MHP field would benefit by elucidating these phenomena. Future work is required to determine the size and kinetic behavior of polyplumbate species, and contextualize these findings in relation to broader trends in materials chemistry beyond MHPs. Ultimately, a complete explanation for the solution speciation, optical absorbance signatures, and the color of MHP precursor inks remains an open challenge to the community.

14 SOLAR ENERGY↗

Polariton Control of Molecular Charge Transfer in Perylene Diimide Semiconductors

We report the modulation of molecular charge transfer in a bay-substituted perylene diimide derivative embedded in a planar distributed Bragg reflector microcavity. Angle-resolved reflectance spectra confirm the formation of upper and lower polaritons with clear Rabi splitting, indicating strong coupling between the cavity mode and molecular excitons. Using broadband transient absorption spectroscopy, we compare the ultrafast dynamics of cavity and non-cavity films. While excited-state absorption and stimulated emission pathways remain largely unchanged, kinetic modeling reveals a moderate increase in the charge transfer rate and yield under strong coupling. This enhancement is attributed to a reduction in the effective driving force via the formation of the lower polariton, placing the system deeper into the Marcus inverted regime. Our results demonstrate a promising non-chemical method leveraging cavity quantum electrodynamics to modulate charge separation processes in molecular semiconductors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of the IES Plug-and-Play Framework

This report discusses the status of the flexible plug-and-play framework development currently ongoing that aims to integrate Modelica/Dymola with the Risk Analysis and Virtual ENvironment (RAVEN) software in terms of both Functional Mock-Up Interface (FMI)/Functional Mock-Up Unit (FMU) construction and repository structures that aim to ease the sharing and simulation of complex dynamic models. This report aims to provide an overview of all the performed activities resolving around the deployment of methods, software infrastructures, guidelines and workflow for the construction and usage of models, encapsulated using the FMI/FMU protocols and standards. In particular, the report is organized in three main macro-subjects, which are connected to each other: - FMI/FMU adaptors for modelica models - HYBRID repository new structure and open-source deployment - RAVEN FMI/FMU exporting capabilities and Artificial Intelligence (AI)-based analysis acceleration. The first part of the report discusses the FMI/FMU adaptors that have been created within the HYBRID repository to allow users to quickly export models, such as FMUs. Several examples are shown that highlight the step-by-step process of converting an existing Modelica model into an FMU for use within the Dymola platform. Simulation results demonstrate that, while minor differences may occur, the overall control, trends, and solution integrity are maintained between standard Modelica simulation and FMU simulation results. However, it is worth noting that, for small systems, the FMU results have a slower simulation time than the Modelica only simulation. Using this process, a company can provide models that contain proprietary information to entities without disclosing any of the information about the model that could be considered business sensitive. Such an ability would allow institutions to bypass the necessity of “whitewashing” data. In the second part of the report, the new structure of the HYBRID repository is discussed with a major focus on the series of updates that has been completed. These updates include the addition of Modelica system-level regression tests and software quality assurance documentation that ensure that modifications to the Modelica models do not alter system-level model results. The third and final part of the report aims to report the work that has been performed for the deployment of methods and workflows for the construction of RAVEN AI-based models compliant with the FMI/FMU standard. Such development represents the key for the deployment of the concept of “Flexible ecosystem” since it allows for the replacement of high-fidelity modelica models (or any other FMI/FMU compliant model) with RAVEN generated AI surrogate models. Overall, extensive work has been completed on developing FMUs and FMIs from existing models, understanding the requirements and limitations of FMUs, and open-sourcing the HYBRID repository with an integrated regression system.

14 SOLAR ENERGY↗

Monthly averages of ED2 model simulations initialized with airborne lidar structure, Jan 1981-Dec 2018, Brazilian Amazon

Deforestation and forest degradation (selective logging, fires, fragmentation) have impacted nearly 40% of the original extent of the Brazilian Amazon, and have markedly impacted forest structure across the region. To date, few studies analysed how shifts in forest structure from degradation influence the forest sensitivity to climate extremes, because of the complex interactions between forest structure and micro-environmental conditions. To address this knowledge gap, we carried out a series of simulations across the Brazilian Amazon using the Ecosystem Demography Model (ED2), using observed forest structure derived from 541 airborne lidar transects (375 ha each) and two scenarios representing forest recovery and expansion of degradation to investigate how shifts in forest structure impact ecosystem function under near-average and extreme climate conditions, as part of the manuscript Longo et al 2025 "Degradation and Deforestation Increase the Sensitivity of the Amazon Forest to Climate Extremes". This dataset provides the output results from the ED2 model simulations for the three simulations at monthly time scales, in NetCDF format. For all simulations, we used bias-corrected hourly reanalyses (WFDE5) for most meteorological drivers, except for precipitation, which was obtained from CHIRPS. The meteorological drivers used in the study span 38 years (Jan 1981–Dec 2018). The output results correspond to the last 38 years of simulation (one full cycle of meteorological drivers), in which ED2 simulations used static stand structure (i.e., the forest structure was held constant). The following files are provided:ED2_emean_Global_R004_BrAmaz_s1c0t0l0f0.nc. This corresponds to the Control simulation. The forest structure was obtained from the airborne lidar.ED2_emean_Global_R005_BrAmaz_s1c0t1l1f0.nc. This corresponds to the Degraded simulation. The forest structure was obtained from a spin-up simulation initialized with airborne lidar and a scenario that expanded deforestation and selective logging across the Amazon.ED2_emean_Global_R006_BrAmaz_s1c0t1l0f0.nc. This corresponds to the Recovery simulation. The forest structure was obtained from a spin-up simulation initialized with airborne lidar and a scenario that completely halted deforestation and degradation, allowing degraded forests to recover for 38 years.We also provide file ED2_zones_R004_BrAmaz_s1c0t0l0f0.nc, which classifies each grid cell into zones used in the reference manuscript: 1: Southeast. 2: South. 3: West. 4: Central. 5: Northeast. 6: North. 7: Northwest". Index 0 corresponds to grid cells excluded from sub-region analyses because they were dominated by flooded forests, deforestation, and naturally non-forest vegetation.

54 ENVIRONMENTAL SCIENCES↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗