Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrode array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Salt-Induced Self-Assembly of Bacteria on Nanowire Arrays

Studying bacteria-nanostructure interactions is crucial to gaining controllable interfacing of biotic and abiotic components in advanced biotechnologies. For bioelectrochemical systems, tunable cell-electrode architectures offer a path toward improving performance and discovering emergent properties. As such, Sporomusa ovata cells cultured on vertical silicon nanowire arrays formed filamentous cells and aligned parallel to the nanowires when grown in increasing ionic concentrations. In this work, we propose a model describing the kinetic and the thermodynamic driving forces of bacteria-nanowire interactions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Silicon-based three-dimensional microstructures for radiation dosimetry in hadrontherapy

In this work, we propose a solid-state-detector for use in radiation microdosimetry. This device improves the performance of existing dosimeters using customized 3D-cylindrical microstructures etched inside silicon. The microdosimeter consists of an array of micro-sensors that have 3D-cylindrical electrodes of 15 μm diameter and a depth of 5 μm within a silicon membrane, resulting in a well-defined micrometric radiation sensitive volume. These microdetectors have been characterized using an {sup 241}Am source to assess their performance as radiation detectors in a high-LET environment. This letter demonstrates the capability of this microdetector to be used to measure dose and LET in hadrontherapy centers for treatment plan verification as part of their patient-specific quality control program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Frost Sensor for HVAC Applications

Frost is a common problem in heating, ventilation, and air conditioning (HVAC) systems that can degrade their efficiencies, leading to excessive electricity consumption. Appropriate defrosting is therefore essential for heat pumps and refrigeration systems. However, these systems typically run the defrost cycle based on a predetermined time interval, a method that does not accurately identify the amount of frost and thus consume excessive electricity. To substantially improve defrosting initiation and termination, this paper describes development of a smart sensor based on a capacitive sensing technique that can quantify frost accumulation and difference between frost, ice, and water. The reported sensor adopts interdigitated comb electrodes and can be updated to a potential multifunctional sensor array for the enhancing identification of frost, ice, and water with the integrated measurement of surface temperature, frost capacitance, and resistance. The proposed frost sensor is potentially expected to have widespread applications in HVAC systems, including heat pumps, refrigerators, and commercial refrigeration systems.

Gao, Zhiming↗

Electrical sensing, tracking, and actuation of droplets

Devices, techniques, and processes are disclosed that use electrical impedance to detect of the presence and contents of droplets including cells, nucleic acids, proteins, or solute concentrations in an array of retrievable, trackable, trapped droplets in a fluidic system. Electrodes may be positioned underneath individual droplet traps in a microchannel to assay droplet contents and/or actuating droplets for the release of the droplets from corresponding traps. The disclosed technology may be used for detection of the results of solvent extraction processes including time-dependent quantification of metal ion concentration in the aqueous and organic phases, for wastewater treatment, heavy metal detection, pharmaceutical industry, and/or biotechnology, or for environmental monitoring of wastewater for toxic metal, monitoring of biological cell viability and proliferation, monitoring of extraction processes used in heavy metal mining, monitoring of extraction processes used in nuclear fuel processing, monitoring kinetics of enzyme processes, and/or assessing pharmacodynamics and drug efficacy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microelectrode Arrays for Electrochemical Cycling of Individual Battery Particles

The electrochemical characterization of battery materials is usually performed on porous electrodes containing conductive additives, binders, and ensembles of redox-active particles at densities as high as 10 15 cm –3 . These complex structures often obscure individual battery particles’ intrinsic properties, hindering insights into the fundamentals of battery electrochemistry. To address this challenge, we developed microelectrode arrays to enable the charge and discharge of individual battery particles in liquid electrolytes. In this Methods and Protocols paper, we describe the fabrication of the microelectrode array chips, the assembly of particles onto microelectrodes, and the different types of electrochemical techniques that can be used, including galvanostatic cycling, cyclic voltammetry, potentiostatic intermittent titration, and electrochemical impedance spectroscopy. We use micron-sized lithium cobalt oxide as a model system to showcase the reliability and versatility of single-particle electrochemical experiments enabled by our microelectrode array. In conclusion, we aim to provide a detailed description to promote future uses of microelectrode arrays in fundamental research of batteries and other electrochemical systems.

25 ENERGY STORAGE↗

Three-dimensional crossbar arrays of self-rectifying Si/SiO 2 /Si memristors

Memristors are promising building blocks for the next generation memory, unconventional computing systems and beyond. Currently common materials used to build memristors are not necessarily compatible with the silicon dominant complementary metal-oxide-semiconductor (CMOS) technology. Furthermore, external selector devices or circuits are usually required in order for large memristor arrays to function properly, resulting in increased circuit complexity. Here we demonstrate fully CMOS-compatible, all-silicon based and self-rectifying memristors that negate the need for external selectors in large arrays. It consists of p- and n-type doped single crystalline silicon electrodes and a thin chemically produced silicon oxide switching layer. The device exhibits repeatable resistance switching behavior with high rectifying ratio (10 5 ), high ON/OFF conductance ratio (10 4 ) and attractive retention at 300 °C. We further build a 5-layer 3-dimensional (3D) crossbar array of 100 nm memristors by stacking fluid supported silicon membranes. The CMOS compatibility and self-rectifying behavior open up opportunities for mass production of memristor arrays and 3D hybrid circuits on full-wafer scale silicon and flexible substrates without increasing circuit complexity.

36 MATERIALS SCIENCE↗

Electric-Field Assisted Assembly of Colloidal Particles into Ordered Nonclose-Packed Arrays

Nonclose-packed colloidal arrays have many potential applications ranging from plasmonic sensors, light trapping for photovoltaics, to transparent electrodes. However, scalable fabrication of those structures remains a challenge. In this Article, we investigate the robustness of an electric-field assisted approach systematically. A monolayer of nonclose-packed crystalline array is first created under a low-frequency alternating-current electric field in solution. We then apply a sequence of direct-current pulses to fix the particle array onto the substrate so that it remains intact even after both field removal and solvent evaporation. Key process parameters such as the alternating-current field strength, direct-current magnitude, particle concentration, and solvent-evaporation rate that affect both ordering and fixing of colloidal particles have been studied systematically. Here, we find that direct currents with an intermediate magnitude induce electrophoretic motion of particles toward the substrate and facilitate their permanent adhesion on the substrate due to strong van der Waals attraction. A higher current, however, causes lateral aggregation of particles arising from electroosmotic flow of solvent and destroys the periodic ordering between particles. This approach, in principle, can be conveniently adapted into the continuous convective assembly process, thus making the fabrication of nonclose-packed colloidal arrays scalable.

42 ENGINEERING↗

Mechanically and Chemically Robust Sandwich-Structured C@Si@C Nanotube Array Li-Ion Battery Anodes

Stability and high energy densities are essential qualities for emerging battery electrodes. Because of its high specific capacity, silicon has been considered a promising anode candidate. However, the several-fold volume changes during lithiation and delithiation leads to fractures and continuous formation of an unstable solid-electrolyte interphase (SEI) layer, resulting in rapid capacity decay. Here, we present a carbon–silicon–carbon (C@Si@C) nanotube sandwich structure that addresses the mechanical and chemical stability issues commonly associated with Si anodes. The C@Si@C nanotube array exhibits a capacity of ~2200 mAh g –1 (~750 mAh cm –3 ), which significantly exceeds that of a commercial graphite anode, and a nearly constant Coulombic efficiency of ~98% over 60 cycles. In addition, the C@Si@C nanotube array gives much better capacity and structure stability compared to the Si nanotubes without carbon coatings, the ZnO@C@Si@C nanorods, a Si thin film on Ni foam, and C@Si and Si@C nanotubes. In situ SEM during cycling shows that the tubes expand both inward and outward upon lithiation, as well as elongate, and then revert back to their initial size and shape after delithiation, suggesting stability during volume changes. The mechanical modeling indicates the overall plastic strain in a nanotube is much less than in a nanorod, which may significantly reduce low-cycle fatigue. Furthermore, the sandwich-structured nanotube design is quite general, and may serve as a guide for many emerging anode and cathode systems.

25 ENERGY STORAGE↗

Transparently wrap-gated semiconductor nanowire arrays for studies of gate-controlled photoluminescence

We present a technique to measure gate-controlled photoluminescence (PL) on arrays of semiconductor nanowire (NW) capacitors using a transparent film of Indium-Tin-Oxide (ITO) wrapping around the nanowires as the gate electrode. By tuning the wrap-gate voltage, it is possible to increase the PL peak intensity of an array of undoped InP NWs by more than an order of magnitude. The fine structure of the PL spectrum reveals three subpeaks whose relative peak intensities change with gate voltage. We interpret this as gate-controlled state-filling of luminescing quantum dot segments formed by zincblende stacking faults in the mainly wurtzite NW crystal structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High power density fuel cell comprising an array of microchannels

A phosphoric acid fuel cell according to one embodiment includes an array of microchannels defined by a porous electrolyte support structure extending between bottom and upper support layers, the microchannels including fuel and oxidant microchannels; fuel electrodes formed along some of the microchannels; and air electrodes formed along other of the microchannels. A method of making a phosphoric acid fuel cell according to one embodiment includes etching an array of microchannels in a substrate, thereby forming walls between the microchannels; processing the walls to make the walls porous, thereby forming a porous electrolyte support structure; forming anode electrodes along some of the walls; forming cathode electrodes along other of the walls; and filling the porous electrolyte support structure with a phosphoric acid electrolyte. Additional embodiments are also disclosed.

25 ENERGY STORAGE↗

Implosion dynamics of a megampere wire-array Z-pinch with an inner low-density foam shell at the Angara-5-1 facility

The implosion dynamics of a pinch with a highly inhomogeneous initial axial distribution of the load mass was studied experimentally. A cascade array consisting of a double nested tungsten wire array and a coaxial inner cylindrical shell located symmetrically with respect to the high-voltage electrodes was used as a load of the Angara-5-1 high-current generator. The cylindrical foam shell was half as long as the cathode− anode gap, and its diameter was equal to the diameter of the inner wire array. It is shown experimentally that two stages are typical of the implosion dynamics of such a load: the formation of two separate pinches formed as a result of implosion of the wire array near the cathode and anode and the subsequent implosion of the central part of the load containing the cylindrical foam shell. The conditions are determined at which the implosion of the central part of the pinch with the foam cylinder is preceded by intense irradiation of the foam with the soft X-ray (SXR) emission generated by the near-electrode pinches and converting it into the plasma state. Using such a load, which models the main elements of the scheme of a dynamic hohlraum for inertial confinement fusion, it is possible to increase the efficiency of interaction between the outer accelerated plasma sheath and the inner foam shell by preionizing the foam with the SXR emission of the near-electrode pinches.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Highly Uniform Resistive Switching in HfO 2 Films Embedded with Ordered Metal Nanoisland Arrays

Memristors enter a critical developmental stage where emerging large-scale integration methods face major challenges with severe switching instabilities in the oxide layer. In this work, the superior uniformity is achieved within HfO 2 films by embedding highly ordered metal nanoisland (NI) arrays. Embedded films exhibit a significant reduction in both SET and RESET while displaying enhanced uniformity in operating voltages and resistance states. This behavior is attributed to the concentration of electric fields along Pt and Ti NIs and their interactions with the surrounding oxide film matrix environment, which induce separate and distinct filamentary formation mechanisms that affect the stability. A method is reported to further optimize the uniformity of the SET voltage by translating the NI array position down the film-thickness dimension towards the bottom electrode. A comparison of the density and distribution of the oxygen vacancies responsible for the formation/dissolution of conducting filaments is made via combined electrostatic force microscopy and conductive atomic force microscopy (c-AFM) studies. Finally, complete observation of the morphological evolution of conducting filaments produced by Pt and Ti is enabled by 3D c-AFM nanotomography and cross-sectional scanning transmission electron microscopy–energy dispersive spectroscopy to provide direct correlations between NI-oxide interactions and overall switching performance.

36 MATERIALS SCIENCE↗

Formation of surface ionization waves in a plasma enhanced packed bed reactor for catalysis applications

Plasma enhanced packed bed reactors (PE-PBRs) intrinsically have complex geometries which makes it difficult to apply conventional scaling laws. For example, controlling the manner of discharge propagation between the micro-discharges (MDs) that occur between dielectrics in PE-PBRs and surface ionization waves (SIWs) that propagate along the dielectrics would aid in selectivity during plasma catalysis. An important parameter in that optimization is the pulse power format. In this work, we investigated the role of applied voltage amplitude and polarity on time resolved dynamics in an atmospheric pressure dielectric barrier discharge (DBD) operating in helium having surface topology resembling PE-PBRs using phase and space resolved optical emission spectroscopy (PROES). To enable systematic studies, the DBD uses an array of dielectric semi-spheres imaged through a top transparent electrode and imaged between the two electrodes from the side. The results were compared with 2-dimensional modeling. We identified three discharge mechanisms: filamentary micro-discharges (F-MDs) in the volume (the space between the surface of the dielectrics and the counter electrode), surface micro-discharges (S-MDs) between the dielectric semi-spheres near their contact points, and SIWs over the curved or flat dielectric surfaces. At the lowest voltages, only F-MDs are generated, once in each half cycle. At intermediate voltages, SIWs also appear which transform into S-MDs at the contact points. When voltage is further increased, several additional pulses are observed, which generate S-MDs at the contact points or a combination F-MDs and S-MDs. The voltage amplitude determines the frequency of these pulses. Modeling results show variations in plasma density and electron temperature for each of the three mechanisms which, in turn, impact production of reactive species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microplasma generator and methods therefor

A low-temperature, atmospheric-pressure microplasma generator comprises at least one strip of metal on a dielectric substrate. A first end of the strip is connected to a ground plane and the second end of the strip is adjacent to a grounded electrode, with a gap being defined between the second end of the strip and the grounded electrode. High frequency power is supplied to the strip. The frequency is selected so that the length of the strip is an odd integer multiple of 1/4 of the wavelength traveling on the strip. A microplasma forms in the gap between the second end of the strip and the grounded electrode due to electric fields in that region. A microplasma generator array comprises a plurality of strongly-coupled resonant strips in close proximity to one another. At least one of the strips has an input for high-frequency electrical power. The remaining strips resonate due to coupling from the at least one powered strip. The array can provide a continuous line or ring of plasma. The microplasma generator can be used to alter the surface of a substrate, such as by adding material (deposition), removal of material (etching), or modifying surface chemistry.

36 MATERIALS SCIENCE↗

Incorporating an optical waveguide into a neural interface

An optical waveguide integrated into a multielectrode array (MEA) neural interface includes a device body, at least one electrode in the device body, at least one electrically conducting lead coupled to the at least one electrode, at least one optical channel in the device body, and waveguide material in the at least one optical channel. The fabrication of a neural interface device includes the steps of providing a device body, providing at least one electrode in the device body, providing at least one electrically conducting lead coupled to the at least one electrode, providing at least one optical channel in the device body, and providing a waveguide material in the at least one optical channel.

42 ENGINEERING↗

Low ion energy RF reactor using an array of plasmas through a grounded grid

A reactor using localized remote plasma in a grid electrode is presented in this study. The aim is to reduce the ion bombardment energy inherent in RF capacitively coupled parallel plate reactors used to deposit large area thin film silicon solar cells. High ion bombardment energy could cause defects in silicon layers and deteriorate electrical interfaces, therefore, by reducing the ion bombardment energy, lower defect density might be obtained. In this study, the low ion bombardment energy results from the reactor design. By inserting a grounded grid close to the RF electrode of a parallel plate reactor, the electrode area asymmetry is increased while retaining the lateral uniformity required for large area deposition. This asymmetry causes a strong negative self-bias voltage, which reduces the time-averaged plasma potential and thus lowers the ion bombardment energy. In addition to the self-bias, the time evolution of plasma light emission and plasma potential RF waveform are also affected by the grid, thereby further reducing the time-averaged plasma potential and ion bombardment energy. Finally, a good correlation between the measured time-averaged plasma potential and measured low ion bombardment energy is found in a broad range of RF voltages.

36 MATERIALS SCIENCE↗

Atomically Dispersed Nickel(I) on an Alloy‐Encapsulated Nitrogen‐Doped Carbon Nanotube Array for High‐Performance Electrochemical CO 2 Reduction Reaction

Abstract Single‐atom catalysts (SACs) show great promise for electrochemical CO 2 reduction reaction (CRR), but the low density of active sites and the poor electrical conduction and mass transport of the single‐atom electrode greatly limit their performance. Herein, we prepared a nickel single‐atom electrode consisting of isolated, high‐density and low‐valent nickel(I) sites anchored on a self‐standing N‐doped carbon nanotube array with nickel–copper alloy encapsulation on a carbon‐fiber paper. The combination of single‐atom nickel(I) sites and self‐standing array structure gives rise to an excellent electrocatalytic CO 2 reduction performance. The introduction of copper tunes the d‐band electron configuration and enhances the adsorption of hydrogen, which impedes the hydrogen evolution reaction. The single‐nickel‐atom electrode exhibits a specific current density of −32.87 mA cm −2 and turnover frequency of 1962 h −1 at a mild overpotential of 620 mV for CO formation with 97 % Faradic efficiency.

Zhang, Tianyu↗