Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron beam imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Relationship of Topside Ionospheric Ion Outflows to Auroral Forms and Precipitation, Plasma Waves, and Convection Observed by Polar

The POLAR satellite often observes upflowing ionospheric ions (UFIs) in and near the aurora] oval on southern perigee (approx. 5000 km altitude) passes. We present the UFI features observed by the thermal ion dynamics experiment (TIDE) and the toroidal imaging mass angle spectrograph (TIMAS) in the dusk-dawn sector under two different geomagnetic activity conditions in order to elicit their relationships with auroral forms, wave emissions, and convection pattern from additional POLAR instruments. During the active interval, the ultraviolet imager (UVI) observed a bright discrete aurora on the duskside after the substorm onset and then observed a small isolated aurora form and diffuse auroras on the dawnside during the recovery phase. The UFIs showed clear conic distributions when the plasma wave instrument (PWI) detected strong broadband wave emissions below approx. 10 kHz, while no significant auroral activities were observed by UVI. At higher latitudes, the low-energy UFI conics gradually changed to the polar wind component with decreasing intensity of the broadband emissions. V-shaped auroral kilometric radiation (AKR) signatures observed above -200 kHz by PWI coincided with the region where the discrete aurora and the UFI beams were detected. The latitude of these features was lower than that of the UFI conics. During the observations of the UFI beams and conics, the lower-frequency fluctuations observed by the electric field instrument were also enhanced, and the convection directions exhibited large fluctuations. It is evident that large electrostatic potential drops produced the precipitating electrons and discrete auroras, the UFI beams, and the AKR, which is also supported by the energetic plasma data from HYDRA. Since the intense broadband emissions were also observed with the UFIs, the ionospheric ions could be energized transversely before or during the parallel acceleration due to the potential drops.

Hirahara, M.↗

Relationship of Topside Ionospheric Ion Outflows to Auroral Forms and Precipitations, Plasma Waves, and Convection Observed by POLAR

The POLAR satellite often observes upflowing ionospheric ions (UFls) in and near the auroral oval on southern perigee (approximately 5000 km altitude) passes. We present the UFI features observed by the thermal ion dynamics experiment (TIDE) and the toroidal imaging mass-angle spectrograph (TIMAS) in the dusk-dawn sector under two different geomagnetic activity conditions in order to elicit their relationships with auroral forms, wave emissions, and convection pattern from additional POLAR instruments. During the active interval, the ultraviolet imager (UVI) observed a bright discrete aurora on the dusk side after the substorm onset and then observed a small isolated aurora form and diffuse auroras on the dawn side during the recovery phase. The UFls showed clear conic distributions when the plasma wave instrument (PWI) detected strong broadband wave emissions below approximately 10 kHz, while no significant auroral activities were observed by UVI. At higher latitudes, the low-energy UFI conics gradually changed to the polar wind component with decreasing intensity of the broadband emissions. V-shaped auroral kilometric radiation (AKR) signatures observed above approximately 200 kHz by PWI coincided with the region where the discrete aurora and the UFI beams were detected. The latitude of these features was lower than that of the UFI conics. During the observations of the UFI beams and conics, the lower-frequency fluctuations observed by the electric field instrument (EFI) were also enhanced, and the convection directions exhibited large fluctuations. It is evident that large electrostatic potential drops produced the precipitating electrons and discrete auroras, the UFI beams, and the AKR, which is also supported by the energetic plasma data from HYDRA. Since the intense broadband emissions were also observed with the UFIs. the ionospheric ions could be energized transversely before or during the parallel acceleration due to the potential drops.

Hirahara, M.↗

Multi-Bandwidth Frequency Selective Surfaces for Near Infrared Filtering: Design and Optimization

Frequency selective surfaces are widely used in the microwave and millimeter wave regions of the spectrum for filtering signals. They are used in telecommunication systems for multi-frequency operation or in instrument detectors for spectroscopy. The frequency selective surface operation depends on a periodic array of elements resonating at prescribed wavelengths producing a filter response. The size of the elements is on the order of half the electrical wavelength, and the array period is typically less than a wavelength for efficient operation. When operating in the optical region, diffraction gratings are used for filtering. In this regime the period of the grating may be several wavelengths producing multiple orders of light in reflection or transmission. In regions between these bands (specifically in the infrared band) frequency selective filters consisting of patterned metal layers fabricated using electron beam lithography are beginning to be developed. The operation is completely analogous to surfaces made in the microwave and millimeter wave region except for the choice of materials used and the fabrication process. In addition, the lithography process allows an arbitrary distribution of patterns corresponding to resonances at various wavelengths to be produced. The design of sub-millimeter filters follows the design methods used in the microwave region. Exacting modal matching, integral equation or finite element methods can be used for design. A major difference though is the introduction of material parameters and thicknesses that may not be important in longer wavelength designs. This paper describes the design of multi- bandwidth filters operating in the 1-5 micrometer wavelength range. This work follows on a previous design. In this paper extensions based on further optimization and an examination of the specific shape of the element in the periodic cell will be reported. Results from the design, manufacture and test of linear wedge filters built using microlithographic techniques and used in spectral imaging applications will be presented.

Cwik, Tom↗

Allochthonous Addition of Meteoritic Organics to the Lunar Regolith

Preparation of lunar samples 74220,861 was discussed in detail in [3, 4]. Our analysis sequence was as follows: optical microscopy, UV fluorescence imaging, -Raman, FESEM-EDX imaging and mapping, FETEMEDX imaging and mapping of a Focused Ion Beam (FIB) extracted section, and NanoSIMs analysis. We observed fluffytextured C-rich regions of interest (ROI) on three different volcanic glass beads. Each ROI was several m2 in size and fluoresced when exposed to UV. Using FESEM/EDX, the largest ROI measured ~36 m and was located on an edge of a plateau located on the uppermost surface of the bead. The ROI was covered on one edge by a siliceous filament emanating from the plateau surface indicating it was attached to the bead while on the Moon. EDX mapping of the ROI shows it is composed primarily of heterogeneously distributed C. Embedded with the carbonaceous phase are localized concentrations of Si, Fe, Al and Ti indicating the presence of glass and/or minerals grains. -Raman showed strong D- and G-bands and their associated second order bands; intensity and location of these bands indicates the carbonaceous matter is structurally disorganized. A TEM thin section was extracted from the surface of a glass bead using FIB microscopy. High resolution TEM imaging and selected area electron diffraction demonstrate the carbonaceous layer to be amorphous; it lacked any long or short range order characteristic of micro- or nanocrystalline graphite. Additionally TEM imaging also revealed the presence of submicron mineral grains, typically < 50 nm in size, dispersed within the carbonaceous layer. NanoSIMs data will be presented and discussed at the meeting. Given the noted similarities between the carbonaceous matter present on 74220 glass beads and meteoritic kerogen, we suggest the allochthonous addition of meteoritic organics as the most probable source for the C-rich ROIs.

Thomas-Keprta, K. L.↗

Multi-Bandwidth Frequency Selective Surfaces for Near Infrared Filtering: Design and Optimization

Frequency selective surfaces are widely used in the microwave and millimeter wave regions of the spectrum for filtering signals. They are used in telecommunication systems for multi-frequency operation or in instrument detectors for spectroscopy. The frequency selective surface operation depends on a periodic array of elements resonating at prescribed wavelengths producing a filter response. The size of the elements is on the order of half the electrical wavelength, and the array period is typically less than a wavelength for efficient operation. When operating in the optical region, diffraction gratings are used for filtering. In this regime the period of the grating may be several wavelengths producing multiple orders of light in reflection or transmission. In regions between these bands (specifically in the infrared band) frequency selective filters consisting of patterned metal layers fabricated using electron beam lithography are beginning to be developed. The operation is completely analogous to surfaces made in the microwave and millimeter wave region except for the choice of materials used and the fabrication process. In addition, the lithography process allows an arbitrary distribution of patterns corresponding to resonances at various wavelengths to be produced. The design of sub-millimeter filters follows the design methods used in the microwave region. Exacting modal matching, integral equation or finite element methods can be used for design. A major difference though is the introduction of material parameters and thicknesses tha_ may not be important in longer wavelength designs. This paper describes the design of multi-bandwidth filters operating in the I-5 micrometer wavelength range. This work follows on previous design [1,2]. In this paper extensions based on further optimization and an examination of the specific shape of the element in the periodic cell will be reported. Results from the design, manufacture and test of linear wedge filters built using micro-lithographic techniques and used ir spectral imaging applications will be presented.

Cwik, Tom↗

Fabrication of Phononic Filter Structures for Far-IR/sub-mm Detector Applications

A photon noise limited sub-mm/far-IR cold telescope in space will require detectors with noise equivalent power (NEP) less than 1x10-19W/Hz1/2for imaging applications and at least an order of magnitude lower for spectroscopic studies. The detector NEP can be reduced by lowering the operation temperature and improving the thermal isolation between the bolometer and a heat bath. We report on the fabrication of membrane isolated transition edge sensor bolometers incorporating compact (<50 μm) thermal isolation beams based on phononic filters. Phononic filters are created by etching quasi-periodic nanoscale structures into supporting thermo-mechanical beams. The cross-sectional dimensions of the etched features are less than the thermal wavelength at the operating temperature, enabling coherent phonon transport to take place in one dimension. The phonon stop-band can be tuned by adjusting the scale of the quasi-periodic structures. Cascading multiple filter stages can increase bandwidth and provide improved thermal isolation similar to the function of a multi-stage electrical filter. We describe the fabrication of AlMn based transition edge sensor bolometers on silicon and silicon nitride membranes isolated by one-and two-dimensional phononic filters. The phononic filters are patterned through electron beam lithography and isolated with deep reactive ion etching.

Phononic↗

Quasi-Periodic Fluctuations and Chromospheric Evaporation in a Solar Flare Ribbon Observed by Hinode/EIS, IRIS, and RHESSI

The Hinode/Extreme-ultraviolet Imaging Spectrometer (EIS) obtained rapid cadence (11.2 s) EUV stare spectra of an M7.3 flare ribbon in AR 12036 on 2014 April 18. Quasi-periodic (P approx. = 75.6 +/- 9.2 s) intensity fluctuations occurred in emission lines of O IV, Mg VI, Mg VII, Si VII, Fe XIV, and Fe XVI during the flare's impulsive rise, and ended when the maximum intensity in Fe XXIII was reached. The profiles of the O IV- Fe XVI lines reveal that they were all redshifted during most of the interval of quasi-periodic intensity fluctuations, while the Fe XXIII profile revealed multiple components including one or two highly blueshifted ones. This indicates that the flare underwent explosive chromospheric evaporation during its impulsive rise. Fluctuations in the relative Doppler velocities were seen, but their amplitudes were too subtle to extract significant quasi-periodicities. RHESSI detected 25-100 keV hard-X-ray sources in the ribbon near the EIS slit's pointing position during the peaks in the EIS intensity fluctuations. The observations are consistent with a series of energy injections into the chromosphere by nonthermal particle beams. Electron densities derived with Fe XIV (4.6 x 10(exp 10) per cu cm) and Mg VII (7.8 x 10(exp 9) per cu cm) average line intensity ratios during the interval of quasi-periodic intensity fluctuations, combined with the radiative loss function of an optically thin plasma, yield radiative cooling times of 32 s at 2.0 x 10(exp 6) K, and 46 s at 6.3 x 10(exp 5) K (about half the quasi-period); assuming Fe XIV's density for Fe XXIII yields a radiative cooling time of 10(exp 3) s (13 times the quasi-period) at 1.4 x 10(exp 7) K.

Brosius, Jeffrey W.↗

Long-Wave Infrared Dyson Spectrometer

Preliminary results are presented for an ultra compact long-wave infrared slit spectrometer based on the dyson concentric design. The dyson spectrometer has been integrated in a dewar environment with a quantum well infrared photodetecor (QWIP), concave electron beam fabricated diffraction grating and ultra precision slit. The entire system is cooled to cryogenic temperatures to maximize signal to noise ratio performance, hence eliminating thermal signal from transmissive elements and internal stray light. All of this is done while maintaining QWIP thermal control. A general description is given of the spectrometer, alignment technique and predicated performance. The spectrometer has been designed for optimal performance with respect to smile and keystone distortion. A spectral calibration is performed with NIST traceable targets. A 2-point non-uniformity correction is performed with a precision blackbody source to provide radiometric accuracy. Preliminary laboratory results show excellent agreement with modeled noise equivalent delta temperature and detector linearity over a broad temperature range.

imaging↗

Development of Leaky Wave Antennas for Layered Ridge Dielectric Waveguide

The millimeter wave, especially above 100 GHz, and the submillimeter wave frequency spectrum offers the possibility for narrow-beam, high-resolution antennas which are critical for high definition radars required for space debris tracking, airport ground avoidance radars, and missile tracking. In addition, the frequency which most atmospheric constituents may be detected lie in this part of the frequency spectrum. Therefore, the development of electronic components for millimeter/submillimeter wave passive sensors is required for environmental monitoring of the Earth's atmosphere. Typical microwave transmission lines such as microstrip and coplanar waveguide rely on two or more electrical conductors to concentrate and guide the electromagnetic energy. Unfortunately, the surface resistance of the conductors increases as the square root of frequency. In addition, the circuit dimensions must be decreased with increasing frequency to maintain a single mode transmission line which further increases the conductor loss. An alternative family of transmission lines are formed from two or more insulating materials and rely on the differences in the permittivities between the two materials to guide the wave. No metal conductors are required although some dielectric waveguides do utilize a metallic ground plane to facilitate the interconnections of active electrical elements or to reduce the transmission line size. Examples of such transmission lines are image guides, insulated image guides, trapped image guides, ridge guide, and layered ridge dielectric waveguide (LRDW). Although most dielectric waveguides have dimensions on the order of lambda to provide sufficient field confinement, the LRDW has been shown to provide good field confinement for electrically small lines. This offers an advantage in circuit integration. It has been shown that a periodic array of metallic strips placed either along or on top of a dielectric waveguide forms an effective radiator. This antenna is easy to fabricate and there is good background of microstrip type antenna design information in the literature. This paper reports the development of the first frequency scanning antenna fed by a LRDW.

Ponchak, George E.↗

Velocity Characteristics of Evaporated Plasma using Hinode/EIS

This paper presents a detailed study of chromospheric evaporation using the EUV Imaging Spectrometer (EIS) onboard Hinode in conjunction with HXR observat,ions from RHESSI. The advanced capabilities of EIS were used to measure Doppler shifts in 15 emission lines covering the temperature range T=0.05-16 MK during the impulsive phase of a C-class flare on 2007 December 14. Blueshifts indicative of the evaporated material were observed in six emission lines from Fe XIV-XXIV (2-16 MK). Upflow velocity was found to scale with temperature as v(sub up) (kilometers per second) approximately equal to 5-17 T (MK). Although the hottest emission lines, Fe XXIII and Fe XXIV, exhibited upflows of greater than 200 kilometers per second, their line profiles were found to be dominated by a stationary component in stark contrast to the predictions of the standard flare model. Emission from O VI-Fe XIII lines (0.5-1.5 MK) was found to be redshifted by v(sub down) (kilometers per second) approximately equal to 60-17 T (MK) and was interpreted as the downward-moving 'plug' characteristic of explosive evaporation. These downflows occur at temperatures significantly higher than previously expected. Both upflows and downflows were spatially and temporally correlated with HXR emission observed by RHESSI that provided the properties of the electron beam deemed to be the driver of the evaporation. The energy contained in the electron beam was found to be greater than or equal to 10(sup 11) ergs per square centimeter per second consistent with the value required to drive explosive chromospheric evaporation from hydrodynamic simulations.

Milligan, Ryan O.↗

NASA Tech Briefs, May 2008

Topics covered inclde: Deployable Wireless Camera Penetrators; Hand-Held Units for Short-Range Wireless Biotelemetry; Wearable Wireless Telemetry System for Implantable BioMEMS Sensors; Electronic Escape Trails for Firefighters; Architecture for a High-to-Medium-Voltage Power Converter; 24-Way Radial Power Combiner/Divider for 31 to 36 GHz; Three-Stage InP Submillimeter-Wave MMIC Amplifier; Fast Electromechanical Switches Based on Carbon Nanotubes; Solid-State High-Temperature Power Cells; Fast Offset Laser Phase-Locking System; Fabricating High-Resolution X-Ray Collimators; Embossed Teflon AF Laminate Membrane Microfluidic Diaphragm Valves; Flipperons for Improved Aerodynamic Performance; System Estimates Radius of Curvature of a Segmented Mirror; Refractory Ceramic Foams for Novel Applications; Self-Deploying Trusses Containing Shape-Memory Polymers; Fuel-Cell Electrolytes Based on Organosilica Hybrid Proton Conductors; Molecules for Fluorescence Detection of Specific Chemicals; Cell-Detection Technique for Automated Patch Clamping; Redesigned Human Metabolic Simulator; Compact, Highly Stable Ion Atomic Clock; LiGa(OTf)(sub 4) as an Electrolyte Salt for Li-Ion Cells; Compact Dielectric-Rod White-Light Delay Lines; Single-Mode WGM Resonators Fabricated by Diamond Turning; Mitigating Photon Jitter in Optical PPM Communication; MACOS Version 3.31; Fiber-Optic Determination of N2, O2, and Fuel Vapor in the Ullage of Liquid-Fuel Tanks; Spiking Neurons for Analysis of Patterns; Symmetric Phase-Only Filtering in Particle-Image Velocimetry; Efficient Coupler for a Bessel Beam Dispersive Element; and Attitude and Translation Control of a Solar Sail Vehicle.

Source record↗

Coordinated Microstructural and Isotopic Characterization of Diamond Inclusions within the Kenna Ureilite

Introduction: The origin of diamonds in ureilitic meteorites, a major family of ultramafic achondrites, has long been debated, with various formation mechanisms inferred, including: 1) shock conversion of preexisting graphite due to a hypervelocity impact on the ureilite parent body [e.g., 1]; 2) vapor deposition during condensation of the solar nebula [e.g., 2]; or 3) static transformation in the mantle of a large planetesimal (>1000 km in diameter) [e.g., 3]. The Kenna ureilite is a 10.9 kg stone that was found in Kansas in 1972 and is dominantly composed of olivine and pigeonite (68% and 22% modal abundance, respectively), together with minor metal and carbon-rich regions. Within the carbon-rich domains researchers have identified microdiamonds up to ~10 µm in size [4]. Methods: Due to the proximity of the extremely hard microdiamonds with soft graphite and moderately hard silicates, achieving an appropriately flat surface for electron backscatter diffraction (EBSD) analysis has proven challenging. We have, therefore, employed a Hitachi ArBlade 5000 broad beam Ar ion milling system to prepare a sample with an adequately uniform surface flatness across the various minerals. The ion milling dramatically im-proved indexing of the EBSD patterns and facilitated high-resolution microstructural analysis of the carbon-rich domains. After microstructural EBSD analyses using an Oxford Symmetry detector we collected coordinated hy-perspectral cathodoluminescence (CL) analyses using a Gatan Monarc system mounted on a JEOL 7900F field emission (FE) scanning electron microscope at NASA Johnson Space Center. A focused ion beam (FIB) foil was extracted from a region of interest and analyzed using a JEOL 2500 FE scanning transmission electron microscope (STEM). In situ carbon and nitrogen isotopic analyses were collected from diamond-bearing domains using a Cameca NanoSIMS 50L at NASA JSC. Results: The carbon rich regions occur as tabular domains between polygonal olivine and pigeonite, and are composed of aggregates of micrometer-scale diamond with intermediate graphite, oxides and metal grains. Within the microdiamonds, {111} twins are abundant, many of which form ragged lamellae consistent with mechanical twinning. The microdiamond assemblages appear to pseudomorph tabular graphite habits, which together with the abundant deformation twins, support a shock transformation mechanism for microdiamond formation within the Kenna meteorite. Further supporting this observation, the diamond laths show close alignment of <111> and <110> between domains, consistent with a solid-state transformation from graphite along <0001> and <1-210>, respec-tively [5]. A FIB foil was extracted from a region with mechanical twins, and high resolution STEM analyses reveal cross-cutting veins of graphite and oriented kamacite crystals together with additional sets of {111} nano-twins formed in at least three orientations. Isotopic analyses of C and N reveal sector zoning patterns [cf. 3] that are unre-lated to the diamond substructure identified by EBSD yet consistent with hyperspectral CL images. Conclusions: These data provide new constraints on microdiamond formation within ureilites. The microdia-monds exhibit orientation variants defined by aligned <111> and <110> axes consistent with inherited crystallo-graphic orientations from transformation of a single hexagonal graphite parent crystal [5]. Crosscutting the micro-diamonds are veins of graphite and kamacite, together with additional {111} nanotwins. Taken together these data suggest that microdiamonds from ureilites formed from a solid state, diffusionless transformation from graphite, likely associated with a major shock event, which was subject to subsequent reversion either during decompression or a later deformation event. The N and C isotopic sector zoning is unrelated to diamond microstructures and likely reflects inheritance from the parent graphite crystal.

Ureilite↗

NASA Tech Briefs, July 2012

Topics covered include: Instrument Suite for Vertical Characterization of the Ionosphere-Thermosphere System; Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure; Pattern Recognition Algorithm for High-Sensitivity Odorant Detection in Unknown Environments; Determining Performance Acceptability of Electrochemical Oxygen Sensors; Versatile Controller for Infrared Lamp and Heater Arrays; High-Speed Scanning Interferometer Using CMOS Image Sensor and FPGA Based on Multifrequency Phase-Tracking Detection; Ultra-Low-Power MEMS Selective Gas Sensors; Compact Receiver Front Ends for Submillimeter-Wave Applications; Dynamically Reconfigurable Systolic Array Accelerator; Blocking Losses With a Photon Counter; Motion-Capture-Enabled Software for Gestural Control of 3D Mod; Orbit Software Suite; CoNNeCT Baseband Processor Module Boot Code SoftWare (BCSW); Trajectory Software With Upper Atmosphere Model; ALSSAT Version 6.0; Employing a Grinding Technology to Assess the Microbial Density for Encapsulated Organisms; Demonstration of Minimally Machined Honeycomb Silicon Carbide Mirrors; Polyimide Aerogel Thin Films; Nanoengineered Thermal Materials Based on Carbon Nanotube Array Composites; Composite Laminate With Coefficient of Thermal Expansion Matching D263 Glass; Robust Tensioned Kevlar Suspension Design; Focal Plane Alignment Utilizing Optical CMM; Purifying, Separating, and Concentrating Cells From a Sample Low in Biomass; Virtual Ultrasound Guidance for Inexperienced Operators; Beat-to-Beat Blood Pressure Monitor; Non-Contact Conductivity Measurement for Automated Sample Processing Systems; An MSK Radar Waveform; Telescope Alignment From Sparsely Sampled Wavefront Measurements Over Pupil Subapertures; Method to Remove Particulate Matter from Dusty Gases at Low Pressures; Terahertz Quantum Cascade Laser With Efficient Coupling and Beam Profile; Measurement Via Optical Near-Nulling and Subaperture Stitching; 885-nm Pumped Ceramic Nd:YAG Master Oscillator Power Amplifier Laser System; Airborne Hyperspectral Imaging System; Heat Shield Employing Cured Thermal Protection Material Blocks Bonded in a Large-Cell Honeycomb Matrix; and Asymmetric Supercapacitor for Long-Duration Power Storage.

Source record↗

RadSTAR L-Band Imaging Scatterometer: Performance Assessment

RadSTAR is an instrument development program aimed at combining a radiometer and a scatterometer system into a highly compact configuration that uses a single, electronically scanned antenna to provide co-located and simultaneous measurements of emission and backscatter for airborne and spaceborne applications [I]. The program was designed to map soil moisture and ocean salinity, both important components of the water cycle, and to map sea ice density and thickness, an important factor in ocean-atmosphere heat exchange in Polar Regions. The accuracy in estimation of these and a number of other Earth science parameters can be greatly enhanced by providing the co-aligned radar/radiometer microwave measurements. For instance, radiometer estimates of soil moisture from soil emission are affected by emission from vegetation, and from the roughness of the surface. Complementary measurements using the scatterometer can be used to evaluate the vegetation and surface roughness effects. Hence, the combined observations can provide an improved estimate. As with soil moisture, the ocean salinity is a function of the microwave emission from the sea surface temperature (SST) and sea roughness. There, the addition of radar backscatter measurements of sea roughness enables the correction of the emissivity and provide more accurate estimates of ocean salinity. Similar arguments can be made for other important Earth science parameters. This paper discusses the RadSTAR program, the radar system design, calibration, and digital beamforming techniques, and presents preliminary analysis of the data collected during the test flights. The data sets obtained during the flights and during the radar calibration in the anechoic chamber are also employed to asses the performance of the radar. The paper also discusses the Digital Beamforming Synthetic Aperture Radar (DBSAR) processor, a real-time processor recently developed for the LIS instrument which enables beam synthesis, fine resolutions, and large swaths.

Rincon, Rafael↗

Spectral Evidence for Heating at Large Column Mass in Umbral Solar Flare Kernels. I. IRIS Near-UV Spectra of the X1 Solar Flare of 2014 October 25

The GOES X1 flare SOL2014-10-25T17:08:00 was a three-ribbon solar flare observed with the Interface Region Imaging Spectrograph (IRIS)in the near-UV(NUV)and far-UV. One of the flare ribbons crossed a sunspot umbra, producing a dramatic, ∼1000% increase in the NUV continuum radiation. We comprehensively analyze the UV spectral data of the umbral flare brightenings, which provide new challenges for radiative−hydrodynamic modeling of the chromospheric velocity field and the white-light continuum radiation. The emission line profiles in the umbral flare brightenings exhibit redshifts and profile asymmetries, but these are significantly smaller than in another, well-studied X-class solar flare. We present a ratio of the NUV continuum intensity to the FeIIλ2814.45intensity. This continuum-to-line ratio is a new spectral diagnostic of significant heating at high column mass (log m/[gcm−2]>−2) during solar flares because the continuum and emission line radiation originate from relatively similar temperatures but moderately different optical depths. The full spectral readout of these IRIS data also allow for a comprehensive survey of the flaring NUV landscape: in addition to many lines of Fe II and Cr II, we identify a new solar flare emission line, HeIλ2829.91(as previously identified in laboratory and early-type stellar spectra). The Fermi/GBM hard X-ray data provide inputs to radiative−hydrodynamic models (which will be presented in Paper II) in order to better understand the large continuum-to-line ratios, the origin of the white-light continuum radiation, and the role of electron beam heating in the low atmosphere.

Adam F Kowalski↗

Soil Moisture Active and Passive (SMAP) White-Painted Expanded Polystyrene (EPS) Radome Survivability Test

NASA's SMAP Mission launched in January 2015 into a 685 km near-polar, sun-synchronous orbit. The SMAP instrument architecture incorporates an L-band radar and radiometer which share a common feedhorn and mesh reflector. The instrument rotates about the nadir axis at approximately 15 rpm, thereby providing a conically scanning wide swath antenna beam that is capable of achieving global coverage within three days. The radiometer and its associated electronics have tight thermal stability requirements in order to meet the required surface emittance measurement precision from space. Maintaining the thermal stabilities is quite challenging because the radiometer is located on a spinning platform that can either be in full sunlight or eclipse, and thus exposed to a highly transient environment. Stability requirements were met by integrating a light-weight Expanded Polystyrene (EPS) radome into the design to prevent solar illumination of the feed horn interior. The radome was painted white since the thermo-optical properties of bare sunlit EPS degrade rapidly over the three-year mission. Milling of the EPS and solvent within the white paint created cavities on the EPS surface which may introduce localized hot spots possibly violating the EPS glass transition temperature of 96degC and leading to structural integrity concerns. A three-day thermal test was conducted in a vacuum chamber to verify survivability of the radome during a simulated non-spin fault condition at end of mission. A portable solar simulator illuminated the test article and the beam irradiance was kept nearly constant during the entire 50 hour test, except during the first hour which simulated the expected 79degC on-orbit surface temperature of the radome. The test article survived based on the established pass criteria for three separate metrics: dimensional, optical property, and color. If any hot spots exist locally, they did not cause any observable permanent deformation when compared to pre- and post-test images. The test results increase confidence that there is a high probability that the radome will survive the worst-case scenario of a no-spin fault condition at the end of mission.

Mikhaylov, Rebecca↗

Quantitative Measurement of Oxygen in Microgravity Combustion

A low-gravity environment, in space or in ground-based facilities such as drop towers, provides a unique setting for studying combustion mechanisms. Understanding the physical phenomena controlling the ignition and spread of flames in microgravity has importance for space safety as well as for better characterization of dynamical and chemical combustion processes which are normally masked by buoyancy and other gravity-related effects. Due to restrictions associated with performing measurements in reduced gravity, diagnostic methods which have been applied to microgravity combustion studies have generally been limited to capture of flame emissions on film or video, laser Schlieren imaging and (intrusive) temperature measurements using thermocouples. Given the development of detailed theoretical models, more sophisticated diagnostic methods are needed to provide the kind of quantitative data necessary to characterize the properties of microgravity combustion processes as well as provide accurate feedback to improve the predictive capabilities of the models. When the demands of space flight are considered, the need for improved diagnostic systems which are rugged, compact, reliable, and operate at low power becomes apparent. The objective of this research is twofold. First, we want to develop a better understanding of the relative roles of diffusion and reaction of oxygen in microgravity combustion. As the primary oxidizer species, oxygen plays a major role in controlling the observed properties of flames, including flame front speed (in solid or liquid flames), extinguishment characteristics, flame size and flame temperature. The second objective is to develop better diagnostics based on diode laser absorption which can be of real value in both microgravity combustion research and as a sensor on-board Spacelab as either an air quality monitor or as part of a fire detection system. In our prior microgravity work, an eight line-of-sight fiber optic system measured water vapor mole fractions in the NASA Lewis 2.2-sec Drop Tower. In that system, the laser and all electronics resided at the top of the drop tower and was connected via a fiber optic cable to the rig, on which a 'pitch and catch' set of fiber collimating lenses were used to transmit the laser beam across a jet diffusion flame. This system required eight independent detection/demodulation units and had poor spatial resolution. This research builds on this earlier work, resulting in an improved capability for quantitative, nonintrusive measurement of major combustion species. A vertical cavity surface-emitting diode laser (VCSEL) and a continuous spatial scanning method permit the measurement of temporal and spatial profiles of the concentrations and temperatures of molecular oxygen. High detection sensitivity is achieved with wavelength modulation spectroscopy (WMS). One-g experiments are performed using a slot diffusion flame. Microgravity measurements on a solid fuel (cellulose sheet) system are planned for the NASA Lewis 2.2-second Drop Tower Facility.

Silver, Joel A.↗

A Semi-Empirical Scheme for Bathymetric Mapping in Shallow Water by ICESat-2 and Sentinel-2: A Case Study in the South China Sea

To derive shallow water bathymetry for coastal areas, a common approach is to deploy a scanning airborne bathymetric light detection and ranging (LiDAR) system or a shipborne echosounder for ground surveys. However, recent advancements in satellite remote sensing, including the Ice, Cloud and land Elevation Satellite-2 (ICESat-2) offer new tools for generating satellite derived bathymetry (SDB). The key payload onboard ICESat-2 is the Advanced Topographic Laser Altimeter System (ATLAS), a micro-pulse, photon-counting LiDAR system, simultaneously emitting six separate 532 nm beams at 10 kHz pulse rate. However, despite its high resolution, the major limitation for bathymetry is that ICESat-2 only provides along-track height profiles, leaving observation gaps between the parallel ground tracks. Merging ICESat-2 observations with optical multispectral imagery, as demonstrated herein, provides an effective solution for deriving a full scene of water depth in light of the spectral attenuation behavior. This study aims to combine ICESat-2 and Sentinel-2 optical data to derive shallow water bathymetry (depth <20 m) at six islands and reefs in the South China Sea. ICESat-2 ATL03 point clouds of georeferenced photons are first filtered to determine the seafloor elevation along the ground track. Results indicate a root-mean-square error (RMSE) of 0.26–0.61 m as compared with independent observations from an airborne LiDAR campaign. Next, three semi-empirical functions, namely the Modified Linear/Polynomial/Exponential Ratio Models with its kernel formed by the log ratio between Sentinel-2′s green and blue bands, are used to fit the spectral data with ICESat-2 height profiles. After water depth mapping using the trained model, independent ICESat-2 point clouds are used to validate the Sentinel-2 derived bathymetry. The RMSE values of the three models using the weighted average of multiple images for these six islands are within 0.50–0.90 m in 0–15 m deep. We also demonstrate that a synthesis of satellite laser altimetry and optical remote sensing can produce SDB results that potentially meet the requirement of category C in Zones of Confidence (ZOC) of the Electronic Navigational Chart (ENC) in 0–8 m deep. It is foreseen that ICESat-2 will be a helpful tool for mapping coastal and shallow waters around the world especially where bathymetric data are unavailable.

Coastal Bathymetry↗