Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Passive Thermal Control of the Primordial Inflation Polarization Explorer (PIPER) Flight Electronics

The scientific balloon program at NASA offers an exciting and open area of opportunity for testing new technologies and for conducting meaningful experimentation at a fraction of the cost of a space mission. This paper outlines a simple thermal model developed and employed for the Primordial Inflation Polarization ExplorER (PIPER). The sub-orbital environment that PIPER operates in hosts an interesting mix of atmospheric and space thermal challenges. The work done was to mitigate thermal loads and passively cool the payload's exterior mounted electronics at an altitude of 36.6 km. This was done by characterizing the thermal environment and then designing solutions for the heat loads through a combined radiation and conduction passive cooling radiator system thermal model. Despite the simplicity and subsequent limitations of the model, as well as some unexpected payload operational events, the model produced results between 0.31% and 11.8% difference between the predicted values and measured average temperatures. From these results, the model was able to successfully provide estimates for the electronics temperatures. Additional flights will be needed to eliminate unknowns encountered in this flight in order to further refine the model for higher accuracy.

Walts, Alexander R.↗

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Loop Heat Pipe↗

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Thermal Modeling↗

The states of Cygnus X-1

HEAO 3 High Resolution Gamma-Ray Spectrometer observations of Cygnus X-1 in the 48-300 keV range, along with correlated 3-6 keV Ariel 5 data, have led to the identification of a new state for this object with low flux in both the soft and hard X-ray regions. This is followed by a slow increase in the hard X-ray flux to the normal low state of the source, characterized by a low intensity soft X-ray emission and a high intensity hard X-ray emission. The new 'superlow' state is interpreted in terms of the Compton model, where the X-ray emission arises from the scattering of low energy photons and one-billion K hot electrons. The superlow state may be seen as one extreme of a continuum of low state behavior, given that Compton cooling should begin to quench the hot electrons at higher soft X-ray fluxes, giving rise to the softer X-ray spectrum and to the anticorrelation in changes in the soft and hard X-ray fluxes.

Ling, J. C.↗

Apparatus for measuring the force of gravity on freely falling electrons

An apparatus and data analysis technique for measuring the gravitational force on freely falling electrons are described. The measurement required that all forces acting on the electrons be uniform and measurable to about ten to the negative 11th power eV/m. The electrical force along the axis of the 5-cm-diam, vertical copper tube used in the experiment was found to be about six times ten to the negative 11th power eV/m when the tube was cooled to 4.2 K. Forces on electrons due to magnetic field gradients were reduced well below the electrical ones by selecting only ground state electrons for measurement. The absence, at 4.2 K, of much stronger electric fields, which were expected to arise from the patch effect and from differential lattice components, contrasts strongly with measurements of electric fields near metal surfaces made at room temperature.

Witteborn, F. C.↗

Standing shocks in a two-fluid solar wind

We present a numerical study of the formation of standing shocks in the solar wind using a two-fluid time-dependent model in the presence of Alfven waves. Included in this model is the adiabatic cooling and thermal conduction of both electrons and protons. In this study, standing shocks develop in the flow when additional critical points form as a result of either localized momentum addition or rapid expansion of the flow tube below the existing sonic point. While the flow speed and density exhibit the same characteristics as found in earlier studies of the formation of standing shocks, the inclusion of electron and proton heat conduction produces different signatures in the electron and proton temperature profiles across the shock layer. Owing to the strong heat conduction, the electron temperature is nearly continuous across the shock, but its gradient has a negative jump across it, thus producing a net heat flux out of the shock layer. The proton temperature exhibits the same characteristics for shocks produced by momentum addition but behaves differently when the shock is formed by the rapid divergence of the flow tube. The adiabatic cooling in a rapidly diverging flow tube reduces the proton temperature so substantially that the proton heat conduction becomes negligible in the vicinity of the shock. As a result, protons experience a positive jump in temperature across the shock. While Alfven waves do not affect the formation of standing shocks, they contribute to the change of the mmomentum and energy balance across them. We also find that for this solar wind model the inclusion of thermal conduction and adiabatic cooling for the elctrons and protons increases significantly the range of parameters characterizing the formation of standing shocks over those previously found for isothermal and polytropic models.

Habbal, Shadia R.↗

Electron Temperature Maps of the Low Solar Corona: ISCORE Results from the Total Solar Eclipse of 1 August 2008 in China

We conducted an experiment in conjunction with the total solar eclipse of 1 August 2008 in China to determine the thermal electron temperature in the low solar corona close to the solar limb. The instrument, Imaging Spectrograph of Coronal Electrons (ISCORE), consisted of an 8 inch f/10 Schmidt Cassegrain telescope with a thermoelectrically cooled CCD camera at the focal plane. Results are electron temperatures of 1 MK at 1.08 R(solar system) and 1.13 R(solar system) from the Sun center in the polar and equatorial regions, respectively. This experiment confirms the results of an earlier experiment conducted in conjunction with the total eclipse of 29 March 2006 in Libya, and results are that at a given coronal height the electron temperature in the polar region is larger than at the equatorial region. In this paper we show the importance of using the correct photospheric spectrum pertinent to the solar activity phase at the time of the experiment, which is a required parameter for modeling the underlying theoretical concept for temperature interpretation of the measured intensity ratios using color filters.

Reginald, Nelson L.↗

Thermal equilibrium of a cryogenic magnetized pure electron plasma

The thermal equilibrium correlation properties of a magnetically confined pure electron plasma (McPEP) are related to those of a one-component plasma (OCP). The N-particle spatial distribution rho sub s and the Helmholtz free energy F are evaluated for the McPEP to O(lambda sub d-squared/a-squared), where lambda sub d is the thermal de Broglie wavelength and is an interparticle spacing. The electron gyromotion is allowed to be fully quantized while the guiding center motion is quasi-classical. The distribution rho sub s is shown to be identical to that of a classical OCP with a slightly modified potential. To O(lambda sub d-squared/a-squared) this modification does not affect that part of F that is caused by correlations, as long as certain requirements concerning the size of the plasma are met. This theory is motivated by a current series of experiments that involve the cooling of a magnetically confined pure electron plasma to the cryogenic temperature range.

Dubin, D. H. E.↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

Power System for Venus Surface Exploration

A radioisotope power and cooling system is designed to provide electrical power for a probe operating on the surface of Venus. Most foreseeable electronics devices and sensors cannot operate at the 450 C ambient surface temperature of Venus. Because the mission duration is substantially long and the use of thermal mass to maintain an operable temperature range is likely impractical, some type of active refrigeration may be required to keep electronic components at a temperature below ambient. The fundamental cooling parameters are the cold sink temperature, the hot sink temperature, and the amount of heat to be removed. In this instance, it is anticipated that electronics would have a nominal operating temperature of 300 C. Due to the highly thermal convective nature of the high-density (90 bar CO2) atmosphere, the hot sink temperature was assumed to be 50 C, which provided a 500 C temperature of the cooler's heat rejecter to the ambient atmosphere. The majority of the heat load on the cooler is from the high temperature ambient surface environment on Venus, with a small contribution of heat generation from electronics and sensors. Both thermoelectric (RTG) and dynamic power conversion systems were analyzed, based on use of a standard isotope (General-purpose heat source, or GPHS) brick. For the radioisotope Stirling power converter configuration designed, the Sage model predicts a thermodynamic power output capacity of 478.1 watts, which slightly exceeds the required 469.1 watts. The hot sink temperature is 1200 C, and the cold sink temperature is 500 C. The required heat input is 1740 watts. This gives a thermodynamic efficiency of 27.48 %. It is estimated that the mechanical efficiency of the power converter design is on the order of 85 %, based on experimental measurements taken from 500-watt power class, laboratory-tested Stirling engines. The overall efficiency is calculated to be 23.36 %. The mass of the power converter is estimated at approximately 21.6 kg. Additional information is included in the original extended abstract.

Landis, Geoffrey A.↗

The influence of autoionization accompanied by excitation on dielectronic recombination and ionization equilibrium

In the process of dielectronic recombination, the doubly excited state formed by radiationless capture may autoionize preferentially into an excited state of the recombining ion. This additional autoionization process has not been discussed in previous treatments of dielectronic recombination. The dielectronic recombination rates for certain nonhydrogenic Fe ions, although still larger than the direct radiative recombination rates, are found to be substantially reduced by the inclusion of the additional autoionization rate in the branching ratio for the stabilizing radiative transition. Consequently, the temperatures of maximum equilibrium abundance are significantly lower than those predicted by recent calculations. Finally, the radiative energy loss rate coefficients are calculated for radiation processes involving electron Fe-ion collisions in high-temperature plasmas. Electron impact excitation of resonance line radiation is the dominant radiative cooling mechanism in steady-state plasmas at temperatures where ions with bound electrons are abundant. However, it is found that the radiation emitted during dielectronic recombination can be more important than direct recombination radiation and bremsstrahlung.

Jacobs, V. L.↗

Automatic control of liquid cooling garment by cutaneous and external auditory meatus temperatures

An automatic control apparatus for a liquid cooling garment is described that is responsive to actual physiological needs during work and rest periods of a man clothed in the liquid cooling garment. Four skin temperature readings and a reading taken at the external portion of the auditory meatus are added and used in the control signal for a temperature control valve regulating inlet water temperature for the liquid cooling garment. The control apparatus comprises electronic circuits to which the temperatures are applied as control signals and an electro-pneumatic transducer attached to the control valve.

Fulcher, C. W. G.↗

Apollo experience report: Command and service module environmental control system

A comprehensive review is presented of the design philosophy of the Apollo environmental control system together with the development history of the total system and of selected components within the system. In particular, discussions are presented relative to the development history and to the problems associated with the equipment cooling coldplates, the evaporator and its electronic control system, and the space radiator system used for rejection of the spacecraft thermal loads. Apollo flight experience and operational difficulties associated with the spacecraft water system and the waste management system are discussed in detail to provide definition of the problem and the corrective action taken when applicable.

Samonski, F. H., Jr.↗

Design, construction and long life endurance testing of cathode assemblies for use in microwave high-power transmitting tubes

The cathode life test program sponsored by NASA Lewis Research Center at Watkins-Johnson Company has been in continuous operation since 1972. Its primary objective has been to evaluate the long life capability of barium dispenser cathodes to produce emission current densities of 2 A sq. cm. or more in an operational environment simulating that of a highpower microwave tube. The life test vehicles were equipped with convergent flow electron guns, drift space tubes with solenoid magnets for electron beam confinement and water-cooled depressed collectors. A variety of cathode types has been tested, including GE Tungstate, Litton Impregnated, Philips Type B and M, Semicon types S and M, and Spectra-Mat Type M. Recent emphasis has been on monitoring the performance of Philips Type M cathodes at 2 A sq. cm. and Sprectra-Mat and Semicon Type M cathodes at 4 A sq. cm. These cathodes have been operated at a constant current of 616 mA and a cathode anode voltage on the order of 10 kV. Cathode temperatures were maintained at 1010 C true as measured from black body holes in the backs of the cathodes. This report presents results of the cathode life test program from July l982 through April l986. The results include hours of operation and performance data in the form of normalized emission current density versus temperature curves (Miram plots).

Batra, R.↗

Radiative shock oscillations in AM Her cataclysmic binaries

The stability properties of radiative shocks in spherically symmetric accretion flows onto white dwarfs is discussed. Accretion rates that result in shock thicknesses ranging from thin to settling solutions are investigated. Models for white dwarf masses from 0.3 to 1.2 of the solar mass are presented. The effects of unequal ion and electron temperatures, electron thermal conduction, bremsstrahlung, and Compton cooling are included. It is shown that thick two-temperature shocks are unstable to oscillations in the fundamental mode for white dwarf mass up to and including 1.0 of the solar mass. The possibility that the 0.3 to 1.0 Hz optical Quasi-Periodic Oscillations (QPOs) observed in four AM Her type cataclysmic binaries are due to the first overtone instability. Low accretion rate shock instabilities may be responsible for the tens of seconds to several minute X-ray QPOs observed in some AM Her objects.

Wolff, M. T.↗

Neutron viscosity in accretion disks

Neutron viscosity is investigated as a possible mechanism for the dissipation of kinetic energy into luminosity in the innermost parts of accretion disks around compact objects. Simplified models are presented of the self-consistent, steady-state accretion flows in which viscosity is provided by neutron collisions with accreting ions. Ion temperatures are determined by balancing the heating of ions by viscous dissipation to their cooling by Coulomb collisions with the electrons, providing a self-consistent solution between neutron production and their impact on energy dissipation. The results indicate that neutrons can indeed provide the necessary dissipation to sustain the steady-state accretion of matter at rates of about 10 to the -8th solar mass/yr or less, and electron temperatures of about 100 keV-1 MeV. Neutrons thus present a promising way of modeling bright Galactic X-ray sources.

Guessoum, Nidhal↗