Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron linac”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

LINAC Electrical Cabinet - Structural Analysis

Along LINAC s downstream path is a floor containing various cabinets above the LINAC. Of the dozens of cabinets are 4 specific cabinet types: PFN (pulse-forming network) Module, PFN Power Supply, Water Skid, and Marx. Each of these cabinets may contain some of the various contents that include electronics, wiring, circuits, and conduits. In addition, high voltage and low conductivity water (LCW) piping are also present within the cabinets. Occasionally, Lab Technicians perform maintenance and inspections of the cabinets and need to access every part, including the top section that is subject to the weight of the technician standing on top. To ensure the cabinet is structurally safe, a CAD model was developed for each cabinet and a Finite Element Analysis (FEA) was performed on each cabinet to confirm it is safe to stand on.

Blas, Efren↗

Scalable 3D reconstruction for X-ray single particle imaging with online machine learning

X-ray free-electron lasers offer unique capabilities for measuring the structure and dynamics of biomolecules, helping us understand the basic building blocks of life. Notably, high-repetition-rate free-electron lasers enable single particle imaging, where individual, weakly scattering biomolecules are imaged under near-physiological conditions with the opportunity to access fleeting states that cannot be captured in cryogenic or crystallized conditions. Existing X-ray single particle reconstruction algorithms, which estimate the particle orientation for each image independently, are slow and memory-intensive when handling the massive datasets generated by emerging free-electron lasers. Here, we introduce X-RAI (X-Ray single particle imaging with Amortized Inference), an online reconstruction framework that estimates the structure of 3D macromolecules from large X-ray single particle datasets. X-RAI consists of a convolutional encoder, which amortizes pose estimation over large datasets, as well as a physics-based decoder, which employs an implicit neural representation to enable high-quality 3D reconstruction in an end-to-end, self-supervised manner. We demonstrate that X-RAI achieves state-of-the-art performance for small-scale datasets in simulation and challenging experimental settings and demonstrate its unprecedented ability to process large datasets containing millions of diffraction images in an online fashion. These abilities signify a paradigm shift in X-ray single particle imaging towards real-time reconstruction.

Computer science↗

Imaging Wavepackets in Real-Space & Disentangling Ultrafast Solvation Dynamics with High-Energy Ultrafast X-ray Scattering

The microscopic information of solute and solute-solvent motions can be measured using ultrafast diffuse x-ray scattering, and compared to molecular dynamics simulations, as demonstrated in studies of solvated molecular systems done in X-ray free-electron lasers. However, for the typical photon energies used in these experiments, the photon momentum transfer range was limited to lower Q values where the signals arising from different parts of the studied system overlap significantly. Recently, this limitation was greatly alleviated by extending the photon energy at the Linac Coherent Light-Source (LCLS), significantly increasing the accessible momentum transfer range. This improvement is transformative for ultrafast diffuse x-ray scattering measurements, enabling for the first time to disentangle the solute scattering difference signal, that persists to higher Q values, from the bulk solvent and solute-solvent cross-terms difference signals. In addition, it enhances the prediction ability of modeling and simulation methods such as the hybrid QM/MM approach. The extended Q range also opens the way to resolve in real-space details regarding coherent wavepackets motions beyond their center-of-mass positions. Here, we present the first results on high-energy (18keV) diffuse x-ray scattering in solution, demonstrating high fidelity time-resolved scattering and analysis of the photoexcited model photocatalysts PtPOP ([Pt2(POP)4]4-), and IrDimen ([Ir2(dimen)4]2+) in several solvents. These complexes provide ideal systems for demonstrating the ability of high-Q ultrafast scattering and QM/MM simulations to decompose ultrafast solvation dynamics into specific changes in the solute-solvent pair distribution function with a particular focus on how electronically excited states change the interaction between the solvent and photo-catalytically active metal sites. We introduce an approach to further utilize the high-energy capability and demonstrate a single-shot ultra-wide-angle X-ray Scattering modality using two perpendicular detectors, spanning a scattering angle range of more than 100 degrees, allowing to extend the accessible momentum transfer range up to Q~14 Å-1. We develop a model-free method to invert the x-ray scattering signals and enable the recovery of multiple pair-density motions that happen simultaneously, allowing us to directly measure in real-space nuclear wavepacket motions. . [1] Natan, Adi. "Real-Space Inversion and Super-Resolution of Ultrafast X-ray Scattering using Natural Scattering Kernels." arXiv preprint arXiv:2107.05576 (2021)

Natan, Adi↗

Status of conceptual horizontal splitter design for FFA@CEBAF energy upgrade

Jefferson Lab’s Continuous Electron Beam Accelerator Facility (CEBAF) is currently investigating the feasibility of upgrading its maximum operating energy using Fixed-Field Alternating-gradient (FFA) recirculating arcs to increase the total number of recirculations the beam through the pair of LINACs. These FFA arcs will be composed of permanent magnets, with small Panofsky-style multipole correctors. Horizontal splitters are needed to control the beam parameters through these FFA arcs. The geometrical and physical constraints, as well as the beam matching requirements are very restrictive, complicating the design. This work will show the current status of the most mature design, which includes matching solutions, as well as options for extraction of the beam.

Accelerator Physics↗

Determination of excited state molecular structures from time-resolved gas-phase X-ray scattering

We present a comprehensive investigation of a recently introduced method to determine transient structures of molecules in excited electronic states with sub-ångstrom resolution from time-resolved gas-phase scattering signals. The method, which is examined using time-resolved X-ray scattering data measured on the molecule N-methylmorpholine (NMM) at the Linac Coherent Light Source (LCLS), compares the experimentally measured scattering patterns against the simulated patterns corresponding to a large pool of molecular structures to determine the full set of structural parameters. In addition, we examine the influence of vibrational state distributions and find the effect negligible within the current experimental detection limits, despite that the molecules have a comparatively high internal vibrational energy. Here, the excited state structures determined using three structure pools generated using three different computational methods are in good agreement, demonstrating that the procedure is largely independent of the computational chemistry method employed as long as the pool is sufficiently expansive in the vicinity of the sought structure and dense enough to yield good matches to the experimental patterns.

74 ATOMIC AND MOLECULAR PHYSICS↗

Current status of conceptual horizontal splitter design for FFA@CEBAF energy Upgrade

Jefferson Lab’s Continuous Electron Beam Accelerator Facility (CEBAF) is currently investigating the feasibility of upgrading its maximum operating energy using Fixed-Field Alternating-gradient (FFA) recirculating arcs to increase the total number of recirculations of the beam through the pair of LINACs. These FFA arcs will be composed of permanent magnets, with small Panofsky-style multipole correctors. In order to control the beam parameters through these FFA arcs, horizontal splitters must be used. The geometrical and physical constraints, as well as the beam matching requirements are very restrictive, complicating the design. This work will show the current status of the most mature design, which includes matching solutions, as well as options for extraction of the beam.

Accelerator Physics↗

EUV FEL light source based on energy recovery linac with on-orbit laser plasma injection

We report on a week-long study of a conceptual design of EUV FEL light source based on an energy recovery linac with on-orbit laser plasma accelerator injection scheme. We carried out this study during USPAS Summer 2023 session of Unifying Physics of Accelerators, Lasers and Plasma applying the art of inventiveness TRIZ. An ultrashort Ti-sapphire laser accelerates electron beams from a gas target with mean energy of 20 MeV, which are then ramped up to 1 GeV in a five-turn scheme with a series of fixed field alternating magnets and two superconducting RF cavities (100 MeV per cavity per turn). The electron beam is then bypassed to an undulator line optimized to generate EUV light of 13.5 nm at kW level in a single pass.

43 PARTICLE ACCELERATORS↗

Selected advances in the accelerator design of the Future Circular Electron-Positron Collider (FCC-ee)

In autumn 2023, the FCC Feasibility Study underwent a crucial “mid-term review”. We describe some accelerator performance risks for the proposed future circular electron-positron collider, FCC-ee, identified for, and during, the mid-term review. For the collider rings, these are the collective effects when running on the Z resonance – especially resistive wall, beam-beam, and electron cloud –, the beam lifetime, dynamic aperture, alignment tolerances, and beam-based alignment. For the booster, the primary concern is the vacuum system, with regard to impedance and effects of the residual gas. For the injector, the layout and the linac repetition rate are primary considerations. We discuss the various issues and report the planned mitigations.

43 PARTICLE ACCELERATORS↗

Multipacting analysis of the SNS drift tube linac (DTL) RF vacuum window using Spark3d

An ongoing study at the Spallation Neutron Source (SNS) seeks to better understand and address potential multipacting issues associated with the Drift Tube Linac (DTL) RF vacuum windows. An analysis of several failed operational windows showed indications of excessive RF heating on the TiN-coated alumina ceramics. Coupled with vacuum bursts and arcing during conditioning and/or operational periods, these problems have been attributed to electron activity likely caused by multipacting. The status of the study, 3-D electromagnetic simulation results, mitigating techniques and a future experimental plan for studying multipacting in the SNS DTL vacuum windows are presented.

Toby, George↗

Mo-99 Concentration and processing by Solvent Extraction and Ion Exchange

Normally derived from its transient-equilibrium parent molybdenum-99 ( 99 Mo) (t½ = 66 h), the short-lived isotope technetium-99m ( 99m Tc) (t ½ = 6.0 h) is the most widely used medical isotope in diagnostic imaging today. The National Nuclear Security Administration’s (NNSA’s) Material Management and Minimization (M3) program—established under the auspices of the American Medical Isotope Production Act—has been tasked with facilitating the work of domestic 99 Mo suppliers that do not use highly enriched uranium (HEU). Superconducting electron linear accelerators that employ high-Z converter targets can generate bremsstrahlung photons and neutron fluxes that can induce photonuclear reactions and uranium (U) fission. Argonne, in collaboration with industrial partners, has been developing the process chemistry for superconducting linear accelerator (LINAC)-irradiated triuranium octoxide (U 3 O 8 ) targets to produce 99 Mo. In short, the process involves dissolving the irradiated targets in nitric acid, which simultaneously releases valuable fission products (xenon and iodine). After adjusting the acid concentration, producers process the feed using tri-n-butyl phosphate (TBP), then mix the raffinate derived from this extraction cycle with a phosphinic acid such as Cyanex 272 or di(2-ethylhexyl) phosphoric acid (HDEHP), which is selective for Mo (molybdenum liquid liquid extraction [MoLLE]). In the next step, a concentration column comprising an anion exchange platform is used to decontaminate the remaining fission products, generating a pure 99 Mo stream in sodium hydroxide (NaOH)/sodium chloride (NaCl).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

GEANT4 Simulations on Faraday Cup Design for PIP-II Laser Wire Scanner System

The PIP-II accelerator upgrade at Fermilab represents a groundbreaking leap forward in high-energy physics research. This ambitious initiative involves enhancing Fermilab's accelerator complex by replacing the current linear accelerator with a warm front end (WFE) capable of accelerating H- beams up to 2.1 MeV. Subsequently, a superconducting linac further accelerates these beams up to 800 MeV. To precisely measure the transverse beam profile, a combination of traditional wire scanners at the WFE section and Laser wire scanners along the superconducting linac are planned for implementation. This investigation centers on refining the Faraday cup design for the PIP-II Laser wire scanners by utilizing GEANT4, a Monte Carlo simulation toolkit. Leveraging this method enables a comprehensive analysis of particle trajectories, energy deposition, secondary electron emission, backscattering, etc., facilitating optimization through adjustments to cup geometries, materials, and placement to maximize its efficiency.

43 PARTICLE ACCELERATORS↗

22 GeV CEBAF with Novel Fixed Field Alternating Gradient Design

Extending the energy reach of CEBAF up to 22 GeV within the existing tunnel is being explored. Proposed energy upgrade can be achieved by increasing the number of recirculations, while using the existing CEBAF SRF cavity system. Presented scheme is based on an exciting new approach to acceleratie electrons efficiently with multiple passes in a single FFA beam line. Encouraged by recent success of the CBETA Test Accelerator, a proposal was formulated raise CEBAF energy by replacing the highest-energy arcs with Fixed Field Alternating Gradient (FFA) arcs. The new pair of arcs configured with FFA lattice would support simultaneous transport of additional 6 passes with energies spanning a factor of two, using the non-scaling FFA principle implemented with Halbach-derived permanent magnets - a novel magnet technology that significantly saves energy and lowers operating costs. One of the challenges of the multi-pass (11) linac optics is to provide uniform focusing in a vast range of energies, using fixed field lattice. Here, we propose a triplet lattice scaled up with increasing momentum along the linac. This would provide a stable periodic solution covering energy ratio of 1:33. The current CEBAF configured with a 123 MeV injector, makes optical matching in the first linac virtually impossible due to extremely high energy span ratio (1:175). Therefore, we envision replacement of the current injector with a 650 MeV 3-pass recirculating injector based on the existing LERF facility. Finally, the 22 GeV CEBAF would promise to deliver in 10-passes a beam with normalized emittance of 80 mm·mrad and with a relative energy spread of 1.5 × 10-3. Further recirculation beyond 22 GeV is limited by large, 974 MeV per electron, energy loss due to synchrotron radiation.

Bogacz, Slawomir↗

Mixed gain detector configurations for time-resolved X-ray solution scattering

X-ray detection at X-ray free-electron lasers is challenging in part due to the XFEL's extremely short and intense X-ray pulses. Experimental measurements are further complicated by the large fluctuations inherent to the self-amplified spontaneous emission process producing the X-rays. At the Linac Coherent Light Source the ePix10ka2M detector offers multiple gain modes, and auto-ranging between these, to increase the dynamic range while retaining low noise. For diffuse scattering techniques, such as time-resolved X-ray solution scattering, where the shape of the scattering pattern largely does not change between exposures, a fixed mix of different gain modes offers many of the same advantages as auto-ranging. We find that configuring individual ASICs in separate gain modes does not impact the intensity linearity of the gain response and has a limited effect on the effective dynamic range in regions with different gain mode settings while avoiding the complexities of auto-ranging. Small (<5%) non-linear gain contributions arise when pixels on the same ASIC are configured in different gain modes. We present a configuration scheme that is designed to select the optimal mixed gain configuration to minimize effects of saturation in the high-/medium-gain region, while maximizing the number of pixels with higher gain to improve the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Concept and Applications of a Dual Energy Storage Ring

A dual energy electron storage ring configuration is initially proposed as an electron cooler to cool the ion beam in a collider. It consists of two energy loops, the electron beam in the high energy loop undergoes the synchrotron radiation damping to obtain the desired beam property and the beam in the low energy loop is for cooling of the ion beam. The two different energy loops are connected by an energy recovery linac. A lattice design of such a dual energy storage ring has been completed and beam stability conditions are established. We performed numerical simulations to demonstrate the beam qualities and evaluated the cooling performance. In this paper, we present the study results and discuss possible applications of such a concept in many physics research and medical fields.

Dhital, B.↗

Three-dimensional theory of superradiant free-electron lasers

The solitonlike superradiant regime of free-electron lasers (FEL) offers a promising path towards ultrashort pulses, beyond the natural limit dictated by the bandwidth of the high-gain FEL instability. In this work we present a three-dimensional theory of the superradiant regime, including the effects of beam emittance and energy spread. Our work takes advantage of recent developments in nonlinear FEL theory to provide a fully analytical description of solitonlike superradiance. Our theory proves the existence of a diffraction-dominated steady-state regime in which the superradiant peak power grows indefinitely while leaving the pulse duration and on-axis intensity almost unchanged. These results are in excellent agreement with three-dimensional simulations and are supported by recent experimental results at the Linac Coherent Light Source. This work advances nonlinear FEL theory and provides a theoretical framework for the next generation of attosecond x-ray FELs. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Tensile behavior of dual-phase titanium alloys under high-intensity proton beam exposure: radiation-induced omega phase transformation in Ti-6Al-4V

A high-intensity proton beam exposure with 181 MeV energy has been conducted at Brookhaven Linac Isotope Producer facility on various material specimens for accelerator targetry applications, including titanium alloys as a beam window material. The radiation damage level of the analyzed capsule was 0.25 dpa at the beam center region with an irradiation temperature around 120 oC. Tensile tests showed increased hardness and a large decrease in ductility for the dual a+ß-phase Ti-6Al-4V Grade-5 and Grade-23 extra low interstitial alloys, with the near a-phase Ti-3Al-2.5V Grade-9 alloy still exhibiting uniform elongation of a few % after irradiation. Transmission Electron Microscope analyses on Ti-6Al-4V indicated clear evidence of a high-density of defect clusters with size less than 2 nm in each a-phase grain. The ß-phase grains did not contain any visible defects such as loops or black dots, while the diffraction patterns clearly indicated ?-phase precipitation in an advanced formation stage. The radiation-induced ?-phase transformation in the ß-phase could lead to greater loss of ductility in Ti-6Al-4V alloys in comparison with Ti-3Al-2.5V alloy with less ß-phase.google scho

Tensile Test, titanium, acclerator, proton beam↗

A New Design of a Dressed Balloon Cavity with Superior Mechanical Properties

Superconducting spoke cavities are prone to multipactor - resonant raise of a number of electrons due to secondary emission. Recently proposed and tested by TRIUMF balloon-type spoke cavity showed an outstanding multipactor (MP) suppression property but unfortunately serious Q degradation at high fields. A new fully developed design of a dressed balloon cavity which can be used for any proton linac SSR2 section is developed. The design incorporates additional EP ports for high Q-factor demonstration. Superior properties are demonstrated, such as effective multipactor suppression, 40% lower Lorentz force coefficient, zero sensitivity to external pressure. This paper presents the results of coupled structural Multiphysics analysis, and engineering design of the dressed balloon cavity with EP ports.

43 PARTICLE ACCELERATORS↗

The chemRIXS Instrument for Solution-Phase Resonant Inelastic X-ray Scattering at the Linac Coherent Light Source

The chemRIXS instrument at the Linac Coherent Light Source (LCLS) offers new opportunities for studying solution-phase systems with time-resolved soft X-ray spectroscopic methods such as resonant inelastic X-ray scattering (RIXS) using the recently commissioned high-repetition-rate LCLS-II X-ray free electron laser. The orders-of-magnitude X-ray flux improvement provided by the superconducting accelerator, combined with corresponding advances in the optical laser system and the liquid jet recirculation system, enables studies on dilute systems with high signal-to-noise compared to what was possible with the LCLS-I copper accelerator. These capabilities open up time-resolved X-ray absorption spectroscopy and RIXS to entirely new classes of samples, as well as enabling the development of new soft X-ray spectroscopic methods on liquid samples. An overview of the beamline components and the first LCLS-II commissioning results are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗