Search NASA⌕ Search

SEARCH · Search NASA

Results for “electronics analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Techniques and Tools of NASA's Space Shuttle Columbia Accident Investigation

The Space Shuttle Columbia accident investigation was a fusion of many disciplines into a single effort. From the recovery and reconstruction of the debris, Figure 1, to the analysis, both destructive and nondestructive, of chemical and metallurgical samples, Figure 2, a multitude of analytical techniques and tools were employed. Destructive and non-destructive testing were utilized in tandem to determine if a breach in the left wing of the Orbiter had occurred, and if so, the path of the resultant high temperature plasma flow. Nondestructive analysis included topometric scanning, laser mapping, and real-time radiography. These techniques were useful in constructing a three dimensional virtual representation of the reconstruction project, specifically the left wing leading edge reinforced carbon/carbon heat protectant panels. Similarly, they were beneficial in determining where sampling should be performed on the debris. Analytic testing included such techniques as Energy Dispersive Electron Microprobe Analysis (EMPA), Electron Spectroscopy Chemical Analysis (ESCA), and X-Ray dot mapping; these techniques related the characteristics of intermetallics deposited on the leading edge of the left wing adjacent to the location of a suspected plasma breach during reentry. The methods and results of the various analyses, along with their implications into the accident, are discussed, along with the findings and recommendations of the Columbia Accident Investigation Board. Likewise, NASA's Return To Flight efforts are highlighted.

McDanels, Steve J.↗

Liquid oxygen LOX compatibility evaluations of aluminum lithium (Al-Li) alloys: Investigation of the Alcoa 2090 and MMC weldalite 049 alloys

The behavior of liquid oxygen (LOX) compatibility of aluminum lithium (Al-Li) alloys is investigated. Alloy systems of Alcoa 2090, vintages 1 to 3, and of Martin Marietta Corporation (MMC) Weldalite 049 were evaluated for their behavior related to the LOX compatibility employing liquid oxygen impact test conditions under ambient pressures and up to 1000 psi. The developments of these aluminum lithium alloys are of critical and significant interest because of their lower densities and higher specific strengths and improved mechanical properties at cryogenic temperatures. Of the different LOX impact tests carried out at the Marshall Space Flight Center (MSFC), it is seen that in certain test conditions at higher pressures, not all Al-Li alloys are LOX compatible. In case of any reactivity, it appears that lithium makes the material more sensitive at grain boundaries due to microstructural inhomogeneities and associated precipitate free zones (PFZ). The objectives were to identify and rationalize the microstructural mechanisms that could be relaxed to LOX compatibility behavior of the alloy system in consideration. The LOX compatibility behavior of Al-Li 2090 and Weldalite 049 is analyzed in detail using microstructural characterization techniques with light optical metallography, scanning electron microscopy (SEM), electron microprobe analysis, and surface studies using secondary ion mass spectrometry (SIMS), electron spectroscopy in chemical analysis (ESCA) and Auger electron spectroscopy (AES). Differences in the behavior of these aluminum lithium alloys are assessed and related to their chemistry, heat treatment conditions, and microstructural effects.

Diwan, Ravinder M.↗

High Penetration Power Electronics Grid: Modeling and Simulation Gap Analysis

Increased penetration of power electronics in the grid is happening through development of high-power drives (like in Type 3 or 4 wind turbines, industrial drives, etc.), high-voltage direct current (HVdc) systems, flexible alternating current transmission systems (FACTS), energy storage systems (ESSs), inverter-based renewables like solar and wind, electric vehicle chargers, and other technologies. Ongoing research and development in new power electronic technologies including, but not limited to, solid-state power substations (SSPS), extreme fast charging (XFC), solid-state transformers, and multi-port power electronics that integrate multiple sources/loads will further increase penetration levels. To ensure stakeholders can integrate high penetration of power electronic technologies safely and reliably requires tools and methods to assess and evaluate their impact on the grid. Objectives: This report surveys, assesses, and analyzes commercially available and open-source tools that can support the assessment and evaluation of power electronics in future grids with high penetration levels. The study includes aspects that range from power flow analysis to dynamics evaluation (including hardware-in-the-loop – HIL testing) for such systems. The challenges and gaps associated with the current generation of toolsets available to assess the technical impact of introducing high penetration of power electronics are reported. The method is summarized in Figure ES-1.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A new paradigm in electron microscopy: Automated microstructure analysis utilizing a dynamic segmentation convolutional neutral network

Over the past half century, the transmission electron microscope enabled insight into the fundamental arrangements and structures of materials. State-of-the-art electron microscopes can acquire large image datasets across multiple imaging modalities. However, the manual annotation process for feature or defect quantification may not be feasible with the modern microscope. Convolutional neural networks emerged to characterize individual microstructural features from an image in a cost-effective, consistent manner. However, many of these neural network approaches rely on thousands to hundreds of thousands of manual annotations of each feature type across hundreds of images to train the network for adequate performance. This work focused on the development and application of a pixel-wise defect detection machine-learning dynamic segmentation convolutional neural network with associated automated acquisition and postprocessing to identify microstructural features rapidly and quantitatively from a small initial dataset incorporating multiple imaging modes. The approach was demonstrated for characterization of superalloy 718 from both single image acquisition on multiple detectors to in-situ evolution captured with a single detector on a standard desktop computer to demonstrate the low barrier to entry required for widespread adoption. Pixel-by-pixel class identification was excellent with strong identification of chemically distinct phases, structurally distinct phases, and defect structures, thus demonstrating the new paradigm of machine learning-assisted characterization.

36 MATERIALS SCIENCE↗

Analysis of proton and electron spectrometer data from OGO-5 spacecraft

The interaction between the geomagnetic and interplanetary magnetic fields is studied through its effects upon the intensities of solar electrons reaching the polar caps during times of strongly anisotropic electron fluxes in the magnetosheath. During the particle event of November 18, 1968, electrons of solar origin were observed outside the magnetopause with detectors aboard OGO-5. Correlative studies of these satellite observations and concurrent measurements by riometers and ionospheric forward scatter systems in both polar regions revealed that the initial stage of the associated polar cap absorption event is attributable to the arrival of solar electrons. Evidence of a north-south asymmetry in the solar electron flux, at a time when the interplanetary magnetic field vector was nearly parallel with the ecliptic plane, supports an open magnetospheric model. The analysis indicates that an anisotropic electron flux may be isotropized at the magnetopause before propagating into the polar regions.

Pomerantz, M. A.↗

Microstructure Experiments-Enabled MARMOT Simulations of SiC/SiC-based Accident Tolerant Nuclear Fuel System

We have undertaken an experimental-computational project that addresses a few key technology gaps associated with the use of SiC/SiC composites for light water reactor fuel cladding. Two principal endeavors in this project are to assess the irradiation-induced microstructural changes and swelling in SiC/SiC composites, and to characterize and model the porous oxide surface layer (when exposed to steam) along SiC recession that is detrimental to the clad integrity under accident conditions. The project tasks are: (i) ion irradiation and characterization (University of Tennessee, Knoxville), (ii) mechanical tests and analysis (University of South Carolina), (iii) steam exposure tests (Oak Ridge National Laboratory), (iv) electron microscopy and spectroscopic characterization (NC State University), (v) x-ray microscopy and reconstruction (University of South Carolina and NC State University), (vi) phase field modeling and simulations (NC State University and Idaho National Laboratory). The effects of 10 MeV Au ion irradiation at 350°C on the microstructure evolution in SiC/SiC composites are investigated at doses up to 400 displacements per atom (dpa) at the University of Tennessee, Knoxville. Atomic force microscopy and optical profilometry reveal irradiation induced axial and radial shrinkage of the fibers for doses greater than 10 dpa. Based on detailed electron microscopy characterization, the primary cause of the fiber shrinkage is attributed to irradiation-induced loss of carbon packets. Additionally, the multilayer PyC interface is observed to portray high resistance to irradiation damage. The mechanical response and failure mechanisms of un-irradiated samples is also assessed through loading tests and X-ray imaging at the University of South Carolina. Steam exposure tests are performed at the Oak Ridge National Laboratory in a facility that represents a reactor pressure vessel under a loss-of-coolant-accident scenario. The samples that are analyzed methodically in this report are tested for 32/31 hours at 1200°C with a velocity of 0.25 cm/s for the pressures: 0.1 MPa, 0.45 MPa, 0.92 MPa and 1.38 MPa. Scanning/transmission electron microscopy analysis conducted at the NC State University (NCSU) shows that the oxide layer thickness increases with the steam pressure. While the oxide layer is crystalline (α- cristobalite) for the pressures 0.45 MPa, 0.92 MPa and 1.38 MPa, the layer is amorphous at 0.1 MPa. Results from Raman spectroscopy have also confirmed the formation of α-cristobalite phase of SiO₂. The abrupt increase in the integrated Raman intensity ratio between steam pressures 0.1 and 0.45 MPa suggests the onset of accelerated crystallization. Non-destructive three dimensional X-ray microscopy/tomography (XCT) and computational image processing techniques are employed by the University of South Carolina to probe the porous oxidation features on SiC samples at varying pressures. Interestingly, most pores are observed to be located away from the surface as well as the oxide-SiC interface. The average oxide layer thickness assessed from the XCT analysis is seen to be in excellent agreement with the values determined through scanning electron microscopy analysis for the highest pressures where the oxide layer is relatively more uniform. A phase-field model developed by the NC State University and Idaho National Laboratory for simulating oxidation of SiC by steam captures the paralinear kinetics of SiC oxidation with a high degree of fidelity. Results from quasi-one-dimensional and two dimensional simulations show that the pores with oxidizing species lead to a higher volatilization rate. These simulations indicate that the enhanced apparent volatilization rates at higher pressures observed in experiments can be rationalized by the increased volatilization from the pores. The project team has also successfully developed the capability to import images from experiments for realistic evolution of the oxidizing microstructure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Determination of bulk diffusion lengths for angle-lapped semiconductor material via the scanning electron microscope: A theoretical analysis

A standard procedure for the determination of the minority carrier diffusion length by means of a scanning electron microscope (SEM) consists in scanning across an angle-lapped surface of a P-N junction and measuring the resultant short circuit current I sub sc as a function of beam position. A detailed analysis of the I sub sc originating from this configuration is presented. It is found that, for a point source excitation, the I sub sc depends very simply on x, the variable distance between the surface and the junction edge. The expression for the I sub sc of a planar junction device is well known. If d, the constant distance between the plane of the surface of the semiconductor and the junction edge in the expression for the I of a planar junction is merely replaced by x, the variable distance of the corresponding angle-lapped junction, an expression results which is correct to within a small fraction of a percent as long as the angle between the surfaces, 2 theta sub 1, is smaller than 10 deg.

Vonroos, O.↗

Ultrasensitive Label-free Electronic Chip for DNA Analysis Using Carbon Nanotube Nanoelectrode Arrays

There is a strong need for faster, cheaper, and simpler methods for nucleic acid analysis in today s clinical tests. Nanotechnologies can potentially provide solutions to these requirements by integrating nanomaterials with biofunctionalities. Dramatic improvement in the sensitivity and multiplexing can be achieved through the high-degree miniaturization. Here, we present our study in the development of an ultrasensitive label-free electronic chip for DNA/RNA analysis based on carbon nanotube nanoelectrode arrays. A reliable nanoelectrode array based on vertically aligned multi-walled carbon nanotubes (MWNTs) embedded in a SiO2 matrix is fabricated using a bottom-up approach. Characteristic nanoelectrode behavior is observed with a low-density MWNT nanoelectrode array in measuring both the bulk and surface immobilized redox species. The open-end of MWNTs are found to present similar properties as graphite edge-plane electrodes, with a wide potential window, flexible chemical functionalities, and good biocompatibility. A BRCA1 related oligonucleotide probe with 18 bases is covalently functionalized at the open ends of the MWNTs and specifically hybridized with an oligonucleotide target as well as a PCR amplicon. The guanine bases in the target molecules are employed as the signal moieties for the electrochemical measurements. Ru(bpy)3(2+) mediator is used to further amplify the guanine oxidation signal. This technique has been employed for direct electrochemical detection of label-free PCR amplicon through specific hybridization with the BRCAl probe. The detection limit is estimated to be less than approximately 1000 DNA molecules, approaching the limit of the sensitivity by laser-based fluorescence techniques in DNA microarray. This system provides a general electronic platform for rapid molecular diagnostics in applications requiring ultrahigh sensitivity, high-degree of miniaturization, simple sample preparation, and low- cost operation.

Li, Jun↗

Calibration of a two-color soft x-ray diagnostic for electron temperature measurement

The two-color soft x-ray (SXR) tomography diagnostic on the Madison Symmetric Torus is capable of making electron temperature measurements via the double-filter technique; however, there has been a 15% systematic discrepancy between the SXR double-filter (SXR{sub DF}) temperature and Thomson scattering (TS) temperature. Here we discuss calibration of the Be filters used in the SXR{sub DF} measurement using empirical measurements of the transmission function versus energy at the BESSY II electron storage ring, electron microprobe analysis of filter contaminants, and measurement of the effective density. The calibration does not account for the TS and SXR{sub DF} discrepancy, and evidence from experiments indicates that this discrepancy is due to physics missing from the SXR{sub DF} analysis rather than instrumentation effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved electron spectroscopy for chemical analysis of photodissociation: Photoelectron spectra of Fe(CO) 5 , Fe(CO) 4 , and Fe(CO) 3

The prototypical photoinduced dissociation of Fe(CO) 5 in the gas phase is used to test time-resolved x-ray photoelectron spectroscopy for studying photochemical reactions. Upon one-photon excitation at 266 nm, Fe(CO) 5 successively dissociates to Fe(CO) 4 and Fe(CO) 3 along a pathway where both fragments retain the singlet multiplicity of Fe(CO) 5 . The x-ray free-electron laser FLASH is used to probe the reaction intermediates Fe(CO) 4 and Fe(CO) 3 with time-resolved valence and core-level photoelectron spectroscopy, and experimental results are interpreted with ab initio quantum chemical calculations. Changes in the valence photoelectron spectra are shown to reflect changes in the valence-orbital interactions upon Fe–CO dissociation, thereby validating fundamental theoretical concepts in Fe–CO bonding. Chemical shifts of CO 3σ inner-valence and Fe 3p core-level binding energies are shown to correlate with changes in the coordination number of the Fe center. We interpret this with coordination-dependent charge localization and core-hole screening based on calculated changes in electron densities upon core-hole creation in the final ionic states. This extends the established capabilities of steady-state electron spectroscopy for chemical analysis to time-resolved investigations. Lastly, it could also serve as a benchmark for how charge and spin density changes in molecular dissociation and excited-state dynamics are expressed in valence and core-level photoelectron spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of bunching of an electron beam at optical wavelengths

This paper presents an analysis of the bunching of an electron beam at optical wavelengths by means of the inverse Cerenkov effect. A laser light beam is used to modulate the velocity of the electrons, and this velocity modulation becomes charge-density modulation after an appropriate drift distance. The effects of energy and angular spread of the electrons are included, as well as the impact of scatterings in the index-matching medium. Bunching can occur with reasonable parameter values and the drift distance is of the order of several centimeters.

Chen, C. K.↗

Elementary review of electron microprobe techniques and correction requirements

Report contains requirements for correction of instrumented data on the chemical composition of a specimen, obtained by electron microprobe analysis. A condensed review of electron microprobe techniques is presented, including background material for obtaining X ray intensity data corrections and absorption, atomic number, and fluorescence corrections.

Hart, R. K.↗

The Del Rio ataxite, Texas

Basic data are presented on the Del Rio, Nordheim, and Monahans ataxites found in Texas. Results are reported for bulk-chemistry analysis, metallographic observations, and electron-microprobe analysis of the Del Rio meteorite. It is shown that Del Rio is distinctly different from the other two ataxites in terms of nickel, phosphorous, and carbon content, and is composed of at least three coarse grains in different crystallographic orientations. All the kamacite in Del Rio is found to have transformation structures that are probable shock products, and minor inclusions of daubreelite, schreibersite, and troilite are observed. It is concluded that Del Rio was apparently mildly shocked prior to its fall.

Henderson, E. P.↗

Spectral shape variation of interstellar electrons at high energies

The high energy electron spectrum analysis has shown that the electron intensity inside the H2 cloud region, or in a spiral arm, should be much lower than that outside it and the observed electron energy spectrum should flatten again at about 1 TeV. In the framework of the leady box model the recently established rigidity dependence of the escape pathlength of cosmic rays would predict a high energy electron spectrum which is flatter than the observed one. This divergence is explained by assuming that the leaky box model can only apply to cosmic ray heavy nuclei, and light nuclei and electrons in cosmic rays may have different behaviors in the interstellar propagation. Therefore, the measured data on high energy electrons should be analyzed based on the proposed nonuniform galactic disk (NUGD) mode.

Tan, L. C.↗

Distribution of siderophile and other trace elements in melt rock at the Chicxulub impact structure

Recent isotopic and mineralogical studies have demonstrated a temporal and chemical link between the Chicxulub multiring impact basin and ejecta at the Cretaceous-Tertiary boundary. A fundamental problem yet to be resolved, however, is identification of the projectile responsible for this cataclysmic event. Drill core samples of impact melt rock from the Chichxulub structure contain Ir and Os abundances and Re-Os isotopic ratios indicating the presence of up to approx. 3 percent meteoritic material. We have used a technique involving microdrilling and high sensitivity instrumental neutron activation analysis (INAA) in conjunction with electron microprobe analysis to characterize further the distribution of siderophile and other trace elements among phases within the C1-N10 melt rock.

Schuraytz, B. C.↗