Search NASA⌕ Search

SEARCH · Search NASA

Results for “electronics cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

NASA’s Quiet Electric ENgines (QUEEN): Thermal Analysis and Testing of the Electronic Speed Controller (ESC)

An electric ducted fan system was tested at the NASA Glenn Research Center. Main components of the system include a commercial-off-the-Shelf (COTS) fan and motor, electronic speed controller, and cooling system. Motor speed, voltage, current, and temperatures were measured in this static ground test of the propulsor. The thermal performance of the Electronic Speed Controller (ESC) was also measured using two different methods to cool the ESC: air cooling and cold plate cooling. This propulsor prototype is one of NASA’s Quiet Electric ENgines (QUEENs) and is designated the ‘QUEEN V1.’ The Quiet Electric Engines are being developed for the 25% scale model of the Subsonic Single Aft Engine (SUSAN) Flight Research Vehicle and are intended to explore the potential of distributed electric propulsion for large regional single-aisle aircraft. Lessons learned will be used to guide development of future QUEEN prototypes and thermal management systems.

Firas G Asfoor↗

Installation package for integrated programmable electronic controller and hydronic subsystem - solar heating and cooling

A description is given of the Installation, Operation, and Maintenance Manual and information on the power panel and programmable microprocessor, a hydronic solar pump system and a hydronic heating hot water pumping system. These systems are integrated into various configurations for usages in solar energy management, control and monitoring, lighting control, data logging and other solar related applications.

Source record↗

Performance of thermal adhesives in forced convection

Cooling is critical for the life and performance of electronic equipment. In most cases cooling may be achieved by natural convection but forced convection may be necessary for high wattage applications. Use of conventional type heat sinks may not be feasible from the viewpoint of specific applications and the costs involved. In a heat sink, fins can be attached to the well by ultrasonic welding, by soldering, or with a number of industrially available thermal adhesives. In this paper, the author investigates the heat transfer characteristics of several adhesives and compares them with ultrasonic welding and theoretically calculated values. This experiment was conducted in an air flow chamber. Heat was generated by using heaters mounted on the well. Thermstrate foil, Uniset A401, and Aremco 571 adhesives were tested along with an ultrasonically welded sample. Ultrasonic welding performed far better than the adhesives and Thermstrate foil. This type of experiment can be adapted for a laboratory exercise in an upper level heat transfer course. It gives students an exposure to industrial applications that help them appreciate the importance of the course material.

Kundu, Nikhil K.↗

Design and assembling status of the Mu2e electromagnetic calorimeter mechanical structures

The muon-to-electron conversion (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named disks ) positioned at the relative distance of 70 cm, downstream the aluminum target along the muon beamline, satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5 10^{10} n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10−4 Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 674 crystal matrices employs two aluminum hollow rings and parts made of open- cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 674 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal con- tact with the copper holders. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system. In this poster we will review the constraints on the calorimeter mechanical structures, the technological choices, and the status of assembling at Fermilab.

Pasciuto, D.↗

Exploring mounting solutions for cryogenically cooled thin crystal optics in high power density x-ray free electron lasers

This study investigates three mounting methods—clamping, soldering, and a hybrid clamping–soldering approach—for cryogenically cooled thin diamond crystals crucial to stable operation of X-ray Free Electron Laser (XFEL) systems. While clamping methods exhibit temperature resilience and flexibility, meticulous design is required to prevent stress-induced warping and reduce thermal contact area. Soldering methods offer reliable mechanical and thermal bonding but encounter challenges due to the coefficient of thermal expansion mismatch at cryogenic temperatures. The hybrid method, integrating clamping and soldering with strain relief cuts, effectively mitigates overall distortion caused by mounting and XFEL thermal loads. These findings offer a novel mounting solution for high-performance x-ray optics in XFEL research and applications, ensuring stability and optimal functionality in cryogenic conditions.

Instruments & Instrumentation↗

Hot melt adhesive pad surface attachment assembly concept for on-orbit operations

The use of a hot melt adhesive concept to develop a Surface Attachment Assembly (SAA) for on-orbit attachment and detachment operations for the Manned Maneuvering Unit (MMU) was investigated. The concept involved impregnation of the hot melt adhesive into a fiberglass covered pad which contained electrical heating and thermoelectric cooling devices. The polyamide hot melt adhesive selected can be repeatedly heated to its melting point in a vacuum and provide good adhesion to various surfaces, i.e., reusable surface insulation tiles, metals, and composites, when cooled. After a series of adhesive screening tests, Jet-Melt 3746 was selected from a group of commercially available thermoplastic adhesive candidates which met or exceeded many of the criteria established for the SAA system. The SAA system was designed and fabricted with the goal of proving the concept with a working model rather than attempting to optimize all facets of the system. This system evolved by investigating alternate attachment concepts, designing and fabricating electronic systems to heat and cool the adhesive, and then fabricating electronic systems to heat and cool the adhesive, and then fabricating and testing two prototype full-size units.

Progar, D. J.↗

Validation of multi-temperature nozzle flow code NOZNT

A computer code NOZNT (Nozzle in n-Temperatures), which calculates one-dimensional flows of partially dissociated and ionized air in an expanding nozzle, is tested against five existing sets of experimental data. The code accounts for: a) the differences among various temperatures, i.e., translational-rotational temperature, vibrational temperatures of individual molecular species, and electron-electronic temperature, b) radiative cooling, and c) the effects of impurities. The experimental data considered are: 1) the sodium line reversal and 2) the electron temperature and density data, both obtained in a shock tunnel, and 3) the spectroscopic emission data, 4) electron beam data on vibrational temperature, and 5) mass-spectrometric species concentration data, all obtained in arc-jet wind tunnels. It is shown that the impurities are most likely responsible for the observed phenomena in shock tunnels. For the arc-jet flows, impurities are inconsequential and the NOZNT code is validated by numerically reproducing the experimental data.

Park, Chul↗

Amplified Thermionic Cooling Using Arrays of Nanowires

A class of proposed thermionic cooling devices would incorporate precise arrays of metal nanowires as electron emitters. The proposed devices could be highly miniaturized, enabling removal of heat from locations, very close to electronic devices, that have previously been inaccessible for heat-removal purposes. The resulting enhancement of removal of heat would enable operation of the devices at higher power levels and higher clock speeds. Moreover, the mass, complexity, and bulk of electronic circuitry incorporating these highly miniaturized cooling devices could be considerably reduced, relative to otherwise equivalent circuitry cooled by conventional electromechanical, thermoelectric, and fluidic means. In thermionic cooling, one exploits the fact that because only the highest-energy electrons are thermionically emitted, collecting those electrons to prevent their return to the emitting electrode results in the net removal of heat from that electrode. Collection is effected by applying an appropriate positive bias potential to another electrode placed near the emitting electrode. The concept underlying the proposal is that the thermionic-emission current and, hence, the cooling effect attainable by use of an array of nanowires could be significantly greater than that attainable by use of a single emitting electrode or other electron- emitting surface. The wires in an array according to the proposal would protrude perpendicularly from a planar surface and their heights would be made uniform to within a sub-nanometer level of precision

Yang, Eui-Hyeok↗

Photoelectrons and lunar limb shocks

It is suggested that boundary conditions for solar wind/lunar limb interactions are active. The 'whole-moon' limb does not evoke a shock cone because warm solar wind electrons are replaced by cool photoelectrons that are ejected from the generally smooth areas of the lunar terminator illuminated at glancing angles by the sun. A localized volume of low thermal pressure is created in the solar wind by these cool photoelectrons. The solar wind expands into this volume without shock production. Directly illuminated highland areas exchange hot photoelectrons for warm solar wind electrons. The hot electrons generate a localized pressure increase in the adjacent solar wind flow which evokes a shock streamer in the solar wind. Shock streamers are identifiable by a coincident increase in the magnitude of the solar wind magnetic field. Shock occurrence is controlled by lunar topography, solar activity in the hard ultraviolet, solar wind electron density and thermal velocity, and the density of the solar wind magnetic field.

Criswell, D. R.↗

Resonant Compton cooling and annihilation line production in gamma-ray bursts

Attention is given to a synchrotron self-Compton emission model for gamma-ray bursts which produces narrow annihilation features for a variety of field strengths, primary electron injection energies, and injection rates. In this model, primary electrons are injected and cooled by synchrotron emission in a strong, homogeneous magnetic field, resulting in a pair cascade. Multiple resonant scattering with cyclotron photons efficiently traps and cools pairs in the ground state to an average energy where the Compton energy loss rate is zero, which is in agreement with previous estimates of a Compton temperature. The particle distributions in the ground state are determined by numerically solving the Fokker-Planck equation in the steady state. In the case of isotropic injection of primary electrons, a significant narrow-line feature appears in the overall emission. In the case of beamed injection, the annihilation line is broadened to the extent that it would not be observable.

Preece, R. D.↗

The effect of an isotopic non-equilibrium plasma on electron temperature measurements

Electron temperatures determined by electrostatic probe, diffuse resonance, and radar backscatter techniques in an isotropic two temperature plasma are presented. Plasma models corresponding to the addition of a minor component of energetic electrons, and models corresponding to a process that cools a fraction of the ionospheric electrons are considered. The diffuse resonance temperature is found to lie between the probe and radar backscatter temperatures. The isotropic models corresponding to the addition of energetic electrons cannot support the reported discrepancies between radio wave and probe electron temperature measurements. Temperature differences similar to the observed differences can be produced by models with a fraction of the electrons at a temperature cooler than that of the main component of electrons.

Benson, R. F.↗

Effect of an isotropic nonequilibrium plasma on electron temperature measurements.

The electron temperatures that would be determined (using the conventional single-temperature analysis) by the electrostatic probe, the diffuse resonance, and the radar backscatter techniques in an isotropic two-temperature plasma are presented. Plasma models corresponding to the addition of a minor component of energetic electrons and models corresponding to a process that cools a fraction of the ionospheric electrons are considered. The diffuse resonance temperature is found to lie between the probe and radar backscatter temperatures. The isotropic models corresponding to the addition of energetic electrons cannot support the reported discrepancies between radio wave and probe electron temperature measurements. Temperature differences similar to the observed differences can be produced by models with a fraction of the electrons at a temperature cooler than that of the main component of electrons. These models, however, are difficult to explain in terms of present understanding of the ionospheric plasma.

Benson, R. F.↗

A Polarized Universe

The CMB polarization was produced as light scattered off a primordial cloud of protons and electrons nearly 14 billion years ago, about 400,000 years after the Big Bang. This marks the moment of recombination, when the universe finally cooled enough to allow electrons to join protons. The CMB is the light that broke through the fog.

Wanjek, Christopher↗

Nonthermal electron-positron pair production and the 'universal' X-ray spectrum of active galactic nuclei

A nonthermal model for power-law X-ray and gamma-ray sources is considered. An initial, primary distribution of relativistic electrons is injected and cooled via Compton scattering of soft photons (produced either externally or by the synchrotron mechanism). The scattered photons, constituting a primary gamma-ray source, produce electron-positron pairs that act as a secondary electron injection, which in turn produce a secondary photon spectrum. Pairs formed by a part of the photon spectrum optically thin to pair production are taken into account. The distribution of particles and photons is obtained, and numerical results as well as analytical solutions to certain special cases are presented. For the case of a delta-function primary electron injection it is found that the photon spectrum in the X-ray region is well approximated by a power law, with the energy spectral index alpha(X) lying in the relatively narrow range 0.5-0.9 as the compactness parameter L(x)/R (where L(x) is the X-ray luminosity and R is the source radius) varies over many orders of magnitude. This is proposed as a possible mechanism to explain the universal X-ray spectra observed from active galactic nuclei.

Zdziarski, A. A.↗

Compact electron-beam source for formation of neutral beams of very low vapor pressure materials

In order to form metal vapors for neutral beam studies, an electron-beam heater and a power supply have been designed. The source, which measures about 30 x 50 x 70 mm, consists of a filament, accelerating plate (defined by pole pieces), and a supported target. The electrons from the filament are focused by the field penetration through a 2 mm slit in the high-voltage cage. They are then accelerated to about 5 kV to a ground plate. The electrons then follow a path in the magnetic field and strike the sample to be heated on its front surface. The assembly is attached to a water-cooled base plate. The electron beam source has produced beams of Ta and C particles with densities of about 10 to the 8th power/cu cm.

Rutherford, J. A.↗

Tritium Production Estimates in EIC Cooling Water Systems

Annual tritium production in EIC cooling water has been estimated in one sextant cooling system from expected electron beam and proton beam losses in the tunnel. Beam losses and the secondary particles they produce are the only source within the RHIC Tunnel for producing radioactivity in cooling water, including tritium. The need to estimate tritium production supports decisions on whether cooling water systems are required to meet Suffolk County Article 12 requirements (e.g., double-walled piping, leak detection and containment, etc.). Results are extended to the remaining sextant cooling water systems because of the similarity in tunnel cooling water loads and system volumes.

43 PARTICLE ACCELERATORS↗

Quantitative X-ray - UV Line and Continuum Spectroscopy with Application to AGN: State-Specific Hydrogenic Recombination Cooling Coefficients for a Wide Range of Conditions

Recombination cooling, in which a free electron emits light while being captured to an ion, is an important cooling process in photoionized clouds that are optically thick or have low metallicity. State specific rather than total recombination cooling rates are needed since the hydrogen atom tends to become optically thick in high-density regimes such as Active Galactic Nuclei. This paper builds upon previous work to derive the cooling rate over the full temperature range where the process can be a significant contributor in a photoionized plasma. We exploit the fact that the recombination and cooling rates are given by intrinsically similar formulae to express the cooling rate in terms of the closely related radiative recombination rate. We give an especially simple but accurate approximation that works for any high hydrogenic level and can be conveniently employed in large-scale numerical simulations.

LaMothe, J.↗