Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy conservation code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Jackson Park Hospital Green Building Medical Center

Jackson Park Hospital completed the construction of a new Medical Office Building on its campus this spring. The new building construction has adopted the City of Chicago's recent focus on protecting the environment, and conserving energy and resources, with the introduction of green building codes. Located in a poor, inner city neighborhood on the South side of Chicago, Jackson Park Hospital has chosen green building strategies to help make the area a better place to live and work. The new green building houses the hospital's Family Medicine Residency Program and Specialty Medical Offices. The residency program has been vital in attracting new, young physicians to this medically underserved area. The new outpatient center will also help to allure needed medical providers to the community. The facility also has areas designated to women's health and community education. The Community Education Conference Room will provide learning opportunities to area residents. Emphasis will be placed on conserving resources and protecting our environment, as well as providing information on healthcare access and preventive medicine. The new Medical Office Building was constructed with numerous energy saving features. The exterior cladding of the building is an innovative, locally-manufactured precast concrete panel system with integral insulation that achieves an R-value in excess of building code requirements. The roof is a 'green roof' covered by native plantings, lessening the impact solar heat gain on the building, and reducing air conditioning requirements. The windows are low-E, tinted, and insulated to reduce cooling requirements in summer and heating requirements in winter. The main entrance has an air lock to prevent unconditioned air from entering the building and impacting interior air temperatures. Since much of the traffic in and out of the office building comes from the adjacent Jackson Park Hospital, a pedestrian bridge connects the two buildings, further decreasing the amount of unconditioned air that enters the office building. The HVAC system has an Energy Efficiency Rating 29% greater than required. No CFC based refrigerants were used in the HVAC system, thus reducing the emission of compounds that contribute to ozone depletion and global warming. In addition, interior light fixtures employ the latest energy-efficient lamp and ballast technology. Interior lighting throughout the building is operated by sensors that will automatically turn off lights inside a room when the room is unoccupied. The electrical traction elevators use less energy than typical elevators, and they are made of 95% recycled material. Further, locally manufactured products were used throughout, minimizing the amount of energy required to construct this building. The primary objective was to construct a 30,000 square foot medical office building on the Jackson Park Hospital campus that would comply with newly adopted City of Chicago green building codes focusing on protecting the environment and conserving energy and resources. The energy saving systems demonstrate a state of the-art whole-building approach to energy efficient design and construction. The energy efficiency and green aspects of the building contribute to the community by emphasizing the environmental and economic benefits of conserving resources. The building highlights the integration of Chicago's new green building codes into a poor, inner city neighborhood project and it is designed to attract medical providers and physicians to a medically underserved area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DRACS thermal performance evaluation for FHR

Direct Reactor Auxiliary Cooling System (DRACS) is a passive decay heat removal system proposed for the Fluoride-salt-cooled High-temperature Reactor (FHR) that combines coated particle fuel and a graphite moderator with a liquid fluoride salt as the coolant. The DRACS features three coupled natural circulation/convection loops, relying completely on buoyancy as the driving force. These loops are coupled through two heat exchangers, namely, the DRACS Heat Exchanger and the Natural Draft Heat Exchanger. In addition, a fluidic diode is employed to minimize the parasitic flow into the DRACS primary loop and correspondingly the heat loss to the DRACS during normal operation of the reactor, and to keep the DRACS ready for activation, if needed, during accidents. To help with the design and thermal performance evaluation of the DRACS, a computer code using MATLAB has been developed. This code is based on a one-dimensional formulation and its principle is to solve the energy balance and integral momentum equations. By discretizing the DRACS system in the axial direction, a bulk mean temperature is assumed for each mesh cell. The temperatures of all the cells, as well as the mass flow rates in the DRACS loops, are predicted by solving the governing equations that are obtained by integrating the energy conservation equation over each cell and integrating the momentum conservation equation over each of the DRACS loops. In addition, an intermediate heat transfer loop equipped with a pump has also been modeled in the code. This enables the study of flow reversal phenomenon in the DRACS primary loop, associated with the pump trip process. Experimental data from a High-Temperature DRACS Test Facility (HTDF) are not available yet to benchmark the code. A preliminary code validation is performed by using natural circulation experimental data available in the literature, which are as closely relevant as possible. The code is subsequently applied to the HTDF that is under construction at the Ohio State University.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modeling cross-beam energy transfer with sector ray tracing

Ray-based cross-beam energy transfer (CBET) models are an essential feature of the radiation-hydrodynamic codes used to simulate inertial confinement fusion implosions, but full 3D ray-based CBET calculations can have a prohibitively high computational cost. Sector ray tracing can be used to reduce the cost by orders of magnitude in cases where the coronal plasma and laser drive can be approximated as spherically symmetric. An extension of sector ray tracing (section ray tracing) can be used to relax the assumption of a spherically symmetric drive while still retaining most of the computational savings of a sector ray trace. We discuss the foundations of sector and section ray tracing and compare them to full ray tracing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Alabama Residential Energy Code Field Study: Baseline Report

A research project in the state of Alabama identified opportunities to reduce homeowner utility bills in residential single-family new construction by increasing compliance with the state energy code. The study was initiated in March 2014 and continued through May 2014. During this period, research teams visited 134 homes during various stages of construction, resulting in a substantial data set based on observations made directly in the field. Analysis of the data has led to a better understanding of the energy features present in homes, and indicates nearly $1.3 million in potential savings to Alabama homeowners that could result from increased code compliance. Public and private entities within the state can use this information to justify and catalyze future investments in energy code training and related energy-efficiency programs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Tunnel Event 2020 (G-tunnel event modeling) [Slides]

HOSS (Hybrid Optimization Software Suite) is a fracture mechanics code that properly conserves mass, energy and momentum. HOSS-FSIS was utilized to conduct exploratory calculations (2D plane strain/3D) for the G-tunnel event 2020 where a pseudo NPE 1.1kt HE equivalent source is used. The purpose of this analysis is to determine if the HOSS fluid-solid coupling solver can capture relevant down-tunnel phenomenology.

42 ENGINEERING↗

A Better Handoff for Code Officials

The U.S. Department of Energy's Building Energy Codes Program has partnered with ICC to release the new Building Energy Codes Resource Guide: Code Officials Edition. We created this binder of practical materials for a simple reason: code officials are busy learning and enforcing several codes at once for the diverse buildings across their jurisdictions. This doesn’t leave much time to search www.energycodes.gov, www.iccsafe.org, or the range of other helpful web-based resources for the latest energy codes tools, support, and information. So, we decided to bring the most relevant materials to code officials in a way that works best with their daily routine, and point to where they can find even more. Like a coach’s game plan, the Resource Guide is an "energy playbook" for code officials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Cost-Effectiveness of ASHRAE Standard 90.1-2010 Compared to ASHRAE Standard 90.1-2007

The purpose of this analysis is to examine the cost-effectiveness of the 2010 edition of ANSI/ASHRAE/IES1 Standard 90.1. Standard 90.1 is the model energy standard for commercial and multifamily residential buildings over three floors (ECPA, Public Law 94-385). PNNL analyzed the cost-effectiveness of changes in Standard 90.1 from 90.1-2007 to 90.1-2010, as applied in the United States. During the development of new editions of Standard 90.1, the cost-effectiveness of individual changes (addenda) is often calculated to support the deliberations of Standard Standing Project Committee (SSPC) 90.1. The process does not include analysis of the cost-effectiveness of the entire package of addenda from one version of the standard to the next. Providing states with an analysis of cost-effectiveness may encourage more rapid adoption of newer editions of energy codes based on Standard 90.1. This information may also inform the development of future editions of Standard 90.1.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of Model Building Energy Codes

Pacific Northwest National Laboratory, funded by DOE, conducted an assessment of the prospective impacts of national model building energy codes from 2010 through 2040. A previous PNNL study evaluated the impact of the Building Energy Codes Program; this study looked more broadly at overall code impacts. This report describes the methodology used for the assessment and presents the impacts in terms of energy savings, consumer cost savings, and reduced CO 2 emissions at the state level and at aggregated levels.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

National Energy Code Lighting Power Limits: The Need for an Updated Calculation Process

Lighting energy codes throughout the US have become progressively more stringent due to increased interest in energy efficiency, and associated federal legislation. At the same time, the codes must, and are expected to allow for design flexibility. Historical code development for lighting has been mostly empirical with often limited observation to always make the best fit for the reality of design. With each iteration, the processes used to determine the codes and standards tries to become more closely representative of practical design and application. A natural challenge in this process is the number of variables associated with lighting design that challenges code writers to think critically about the visual needs of people, generally accepted lighting practices, and changes in the market that promote energy efficiency. Despite the issues, the code must keep designs from being wasteful and allow designers the artistic flexibility to achieve the lighting needs of the space. This paper provides a detailed look at these issues and how they affect the code development process through the development of one of the national lighting energy codes/standards. As new 2010 and beyond versions of the codes are in preparation, more detailed methods are being developed to walk that fine line between efficiency and design flexibility. The paper also explains some of the progression of the process of development of national lighting energy codes (ASHRAE/IES 90.1) and its effect on other codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ECsim-CYL: Energy Conserving Semi-Implicit particle in cell simulation in axially symmetric cylindrical coordinates

Based on the previously developed Energy Conserving Semi Implicit Method (ECsim) code, we present its cylindrical implementation, called ECsim-CYL, to be used for axially symmetric problems. The main motivation for the development of the cylindrical version is to greatly improve the computational speed by utilizing cylindrical symmetry. The ECsim-CYL discretizes the field equations in two-dimensional cylindrical coordinates using the finite volume method. For the particle mover, it uses a modification of ECsim’s mover for cylindrical coordinates by keeping track of all three components of velocity vectors, while only keeping radial and axial coordinates of particle positions. In this paper, we describe the details of the algorithm used in the ECsim-CYL and present a series of tests to validate the accuracy of the code including a wave spectrum in a homogeneous plasma inside a cylindrical waveguide and free expansion of a spherical plasma ball in vacuum. Finally, the ECsim-CYL retains the stability properties of ECsim and conserves the energy within machine precision, while accurately describing the plasma behavior in the test cases.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Explicit Modeling of Pebble Temperature in the Porous-medium Framework for Pebble-bed Reactors Applications

In this study, an explicit model for pebble temperature calculations in the framework of a porous-medium approach has been developed and implemented in the SAM code. The solid-phase energy conservation equation, including the explicit modeling of pebble temperature, is a multi-scale model, which can predict the macroscopic (pebble-bed) and microscopic (pebble) temperature distributions under both steady-state and transient conditions. Extensive and successful code verifications and demonstrations have been performed for this newly developed model. By explicitly modeling pebble temperatures, this new model addresses a major deficiency of the previously implemented model, which assumed a local solid-phase thermal equilibrium that is not appropriate for pebble-bed reactor design and safety analysis applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Laslo

The Laslo code solves the one dimensional mass, momentum, and energy conservation equations in Lagrangian form. The intended purpose of this code is to simplify the implementation of material models and the determination of optimal material parameters. Users can implement material models in Python (an open source interpreted language) without the need to recompile the code. Optimal material parameters are determined by providing the desired output and bounds on the parameter set.

Robbins, Joshua↗

Transforming Markets for Energy-Efficient Buildings in China: Final Report on Activity Conducted by the Institute for Market Transformation (IMT) Under Cooperative Agreement DE-FC01-00EE10672 with the U.S. Department of Energy (DOE)

This report summarizes activity conducted by the Institute for Market Transformation and a team of American and Chinese partners in development of a new building energy-efficiency code for the transitional climate zone in the People's Republic of China.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oregon Residential Energy Code Field Study

A research project in the state of Oregon identified opportunities to reduce homeowner utility bills in residential single-family new construction by increasing compliance with the state energy code. The study was initiated in November 2019; data collection began in November 2019 and continued through February 2020. Analysis of the data has led to a better understanding of the energy features present in homes and identified over $600,000 in potential annual savings to Oregon homeowners that could result from increased compliance with the 2017 Oregon Residential Specialty Code (2017 ORSC).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗