Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Coal conversion systems design and process modeling. Volume 1: Application of MPPR and Aspen computer models

The development of a coal gasification system design and mass and energy balance simulation program for the TVA and other similar facilities is described. The materials-process-product model (MPPM) and the advanced system for process engineering (ASPEN) computer program were selected from available steady state and dynamic models. The MPPM was selected to serve as the basis for development of system level design model structure because it provided the capability for process block material and energy balance and high-level systems sizing and costing. The ASPEN simulation serves as the basis for assessing detailed component models for the system design modeling program. The ASPEN components were analyzed to identify particular process blocks and data packages (physical properties) which could be extracted and used in the system design modeling program. While ASPEN physical properties calculation routines are capable of generating physical properties required for process simulation, not all required physical property data are available, and must be user-entered.

Source record↗

Strong adsorption of guanidinium cations to the air–water interface

Combining Deep-UV second harmonic generation spectroscopy with molecular simulations, we confirm and quantify the specific adsorption of guanidinium cations to the air–water interface. Using a Langmuir analysis of measurements at multiple concentrations, we extract the Gibbs free energy of adsorption, finding it larger than typical thermal energies. Molecular simulations clarify the role of polarizability in tuning the thermodynamics of adsorption, and establish the preferential parallel alignment of guanidinium at the air–water interface. As a polyatomic cation, guanidinium represents one of the few examples of a positively charged species to exhibit a propensity for the air-water interface. As such, these results expand on the growing body of work on specific ion adsorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The GEWEX Process Evaluation Study: GEWEX-PROES

Progress in realistically simulating the energy and water cycles in weather and climate models has been slower than desirable. Climate models submitted to the Coupled Model Intercomparison Project Phase-5 (CMIP-5), while more comprehensive than their predecessors, have shown little to no improvement in their biases in simulating key features of the climate system. As a result, uncertainties in global climate and hydrological sensitivities, and in the simulation of regional climate change, have not been reduced significantly. It is time to make use of these opportunities to significantly advance our understanding of key energy and water cycle processes at a wide range of space and time scales, and to provide a more insightful evaluation of the representation of these processes within models. This will require new ways of both analyzing the observations and diagnosing model behavior. The keys to success will be in skillfully combining different data sets and exploring relationships between them, as well as in the ability of models to reproduce those relationships correctly. In response to this challenge, a new GEWEX-wide activity, the GEWEX Process Evaluation Study, will take advantage of the opportunities that the combination of many of the existing data sets provide.

climate models↗

Efficient simulation of optical spectra via machine learning and physical decomposition of environmental effects

Simulations of optical spectra can provide key insights to aid experimental interpretation of electronic excitation phenomena. For chromophores in the condensed phase, these spectra, which incorporate the coupling between electronic excitation and molecular and solvent nuclear motions, can be simulated using excitation energies obtained from molecular dynamics simulations of the chromophore and solvent. Here, we present a hybrid scheme that exploits machine learning and physically informed spectral densities to show that as few as 25 ground and excited state energetic gradient calculations can be used to construct models that accurately predict environment-influenced vibronic coupling in optical spectra. We demonstrate our approach for the green fluorescent protein chromophore in water and the cresyl violet chromophore in methanol. We show that our hybrid approach, employing a machine learning model for the high-frequency spectral density and an ab initio parameterized Debye spectral density for the low-frequency, results in a systematic improvement of the optical absorption lineshape, leading to a simple machine learning scheme that can be used for the simulation of spectral densities and optical spectra.

Snider, Andrew [Univ. of California, Merced, CA (U↗

Study of fuel cell on-site, integrated energy systems in residential/commercial applications

Three building applications were selected for a detailed study: a low rise apartment building; a retail store, and a hospital. Building design data were then specified for each application, based on the design and construction of typical, actual buildings. Finally, a computerized building loads analysis program was used to estimate hourly end use load profiles for each building. Conventional and fuel cell based energy systems were designed and simulated for each building in each location. Based on the results of a computer simulation of each energy system, levelized annual costs and annual energy consumptions were calculated for all systems.

Wakefield, R. A.↗

Study Of Compressibility Corrections To Turbulence Models

Effects on shear layers in simulated confined and unconfined flows studied. Report presents comparative study of some terms that correct for effects of compressibility in standard k-epsilon mathematical model of turbulence where k denotes turbulence kinetic energy and epsilon denotes rate of dissipation of turbulence kenetic energy. Involved simulation of flows by numerical solution of Reynolds-averaged Navier-Stokes equations.

Viegas, J. R.↗

On performing exobiology experiments on an earth-orbital platform with the Gas-Grain Simulation Facility

Laboratory simulations of gas-dust interactions performed on Space Station Freedom in the Gas-Grain Simulation Facility (GGSF) are considered for studying the nature of bodies in the solar system. The GGSF includes a 4-10 liter chamber for experiments with the capability for environmental control, measurement, levitation, and energy. The simulations can provide low gas pressure and dust density in a microgravitational environment.

Huntington, Judith L.↗

Agrivoltaic system design tools for managing trade-offs between energy production, crop productivity and water consumption

Abstract Agrivoltaic systems that locate crop production and photovoltaic energy generation on the same land have the potential to aid the transition to renewable energy by reducing the competition between food, habitat, and energy needs for land while reducing irrigation requirements. Experimental efforts to date have not adequately developed an understanding of the interaction among local climate, array design and crop selection sufficient to manage trade-offs in system design. This study simulates the energy production, crop productivity and water consumption impacts of agrivoltaic array design choices in arid and semi-arid environments in the Southwestern region of the United States. Using the Penman–Monteith evapotranspiration model, we predict agrivoltaics can reduce crop water consumption by 30%–40% of the array coverage level, depending on local climate. A crop model simulating productivity based on both light level and temperature identifies afternoon shading provided by agrivoltaic arrays as potentially beneficial for shade tolerant plants in hot, dry settings. At the locations considered, several designs and crop combinations exceed land equivalence ratio values of 2, indicating a doubling of the output per acre for the land resource. These results highlight key design axes for agrivoltaic systems and point to a decision support tool for their development.

Environmental Sciences & Ecology↗

From models to reality: a systematic review on simulated and measured residential heat pump energy savings

High-performance HVAC solutions are central to residential energy management. A substantial share of these are electric, reversible-cycle systems, with heat pumps representing the largest portion of current and near-term adoption. This review synthesizes peer-reviewed and grey literature on residential space heating and cooling heat pumps. The academic literature is dominated by modeling (73.8%), with limited field measurement (13.1%). Grey literature from United States serve as a supplemental resource providing measured savings. Conversions from electric-resistance heating consistently show the largest site energy reductions, while oil/propane baselines yield moderate savings, and gas baseline scenario often deliver small and region-dependent savings. This study cross-checks the grey literature measured data with simulation data filtered from the ResStock dataset. The comparison indicates a discrepancy between simulations and measured data: simulated site EUIs are typically lower than measured EUIs, but percentage energy savings fall in similar ranges, implying simulations capture directional effects while underestimating energy use. Factors associated with variability and model–measurement differences include system characterization and control representation (e.g., backup heat engagement, thermostat/setpoint strategies, commissioning/installation quality), occupant behavior, weather normalization, metering scope, and envelope characterization. This paper also outlines the proposed methodology for comparing simulation and measured data for heat pumps. It emphasizes the metrics used for comparison and units harmonization, building characteristics matching, and compact metadata are needed for simulations to match measured data. The proposed methodology is expected to improve the credibility of simulated savings as measured evidence grows.

Yu, Lili↗

Timescale Dependence of the Precipitation Response to CO 2 ‐Induced Warming in Millennial‐Length Climate Simulations

Abstract Previous work has shown that estimates of climate sensitivity vary over time in response to abrupt CO 2 forcing in climate model simulations. The energy fluxes that drive warming in response to increasing CO 2 also influence precipitation, which prompts the question: Does the precipitation response therefore also vary over time? We investigate by examining the response of precipitation to warming forced by greenhouse gases—the hydrological sensitivity—in a set of millennial‐length climate simulations with multiple climate models, Long Run Model Intercomparison Project (LongRunMIP). We compare hydrological sensitivity calculated from three different timescales of the simulations: years 1–20, 21–150, and 151–1000. We show that the hydrological sensitivity lacks a consistent dependence on timescale, in contrast to climate sensitivity. Decomposition of the surface energy budget reveals that the relative muting of the multi‐model mean hydrological sensitivity is driven by surface downwelling shortwave flux.

Him (Kinen) Kao, Wing↗

A digital computer simulation and study of a direct-energy-transfer power-conditioning system

A digital computer simulation technique, which can be used to study such composite power-conditioning systems, was applied to a spacecraft direct-energy-transfer power-processing system. The results obtained duplicate actual system performance with considerable accuracy. The validity of the approach and its usefulness in studying various aspects of system performance such as steady-state characteristics and transient responses to severely varying operating conditions are demonstrated experimentally.

Burns, W. W., III↗

Exploring Li-Air Batteries for High Specific Energy and High Power Applications: A Simulation Study

Commercialization of lithium-air batteries face many challenges, such as electrolyte decomposition, short cycle life, low energy efficiency, low power density, etc. However, commercialization of Li-air batteries for mass sensitive applications such as electric vehicles, portable power source, and drones is more challenging due to additional constraints of safety, electrolyte evaporation, high specific energy requirements, and reliable discharge times. In this presentation, we will present our finite element simulation results comparing Li-O2 and Li-air batteries using power density, energy density, specific power, and discharge times as metrics to evaluate different electrolytes and electrode geometry to reduce total mass and maximize discharge current. We use a finite element model and a discharge product model developed in which is based on porous electrode and concentrated electrolyte theories and the discharge product is modeled using quantum tunneling; for reaction kinetics and oxygen diffusion, an improved model was used. The electrolyte properties such as ion conductivity and ion diffusion were obtained from Molecular Dynamics (MD) simulations while the other parameters for the finite element model were calibrated to match experiments at high discharge current densities (>1.5 mA/cm2). The mass densities of different electrolytes were computed using MD simulations as well. For this presentation, we examine the practical electrochemical mass of a system at different current ratings, the sensitivity of mass to the use of ambient air as compared to pure oxygen as well as the electrolyte, which affects maximum current density and the total mass associated with the electrolyte (which includes the mass of additional components), and, the optimization of battery geometry for total discharge time, average discharge voltage, maximum discharge current, and minimum electrochemical mass.

Mehta, M.↗

Simulation of Aircraft Landing Gears with a Nonlinear Dynamic Finite Element Code

Recent advances in computational speed have made aircraft and spacecraft crash simulations using an explicit, nonlinear, transient-dynamic, finite element analysis code more feasible. This paper describes the development of a simple landing gear model, which accurately simulates the energy absorbed by the gear without adding substantial complexity to the model. For a crash model, the landing gear response is approximated with a spring where the force applied to the fuselage is computed in a user-written subroutine. Helicopter crash simulations using this approach are compared with previously acquired experimental data from a full-scale crash test of a composite helicopter.

Lyle, Karen H.↗

A Study of Mars Dust Environment Simulation at NASA Johnson Space Center Energy Systems Test Area Resource Conversion Test Facility

The dust environment on Mars is planned to be simulated in a 20 foot thermal-vacuum chamber at the Johnson Space Center, Energy Systems Test Area Resource Conversion Test Facility in Houston, Texas. This vacuum chamber will be used to perform tests and study the interactions between the dust in Martian air and ISPP hardware. This project is to research, theorize, quantify, and document the Mars dust/wind environment needed for the 20 foot simulation chamber. This simulation work is to support the safety, endurance, and cost reduction of the hardware for the future missions. The Martian dust environment conditions is discussed. Two issues of Martian dust, (1) Dust Contamination related hazards, and (2) Dust Charging caused electrical hazards, are of our interest. The different methods of dust particles measurement are given. The design trade off and feasibility were studied. A glass bell jar system is used to evaluate various concepts for the Mars dust/wind environment simulation. It was observed that the external dust source injection is the best method to introduce the dust into the simulation system. The dust concentration of 30 Mg/M3 should be employed for preparing for the worst possible Martian atmosphere condition in the future. Two approaches thermal-panel shroud for the hardware conditioning are discussed. It is suggested the wind tunnel approach be used to study the dust charging characteristics then to be apply to the close-system cyclone approach. For the operation cost reduction purpose, a dehumidified ambient air could be used to replace the expensive CO2 mixture for some tests.

Chen, Yuan-Liang Albert↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

A note on the maintenance of the atmospheric kinetic energy

The winter simulations of the GLAS climate model and the NCAR community climate model are used to examine the maintenance of the atmospheric kinetic energy. It is found that the kinetic energy is generated in the lower latitudes south of the maximum westerlies, transported northward and then, destroyed in the midlatitudes north of the maximum westerlies. Therefore, the atmospheric kinetic energy is maintained by the counterbalance between the divergence (convergence) of kinetic energy flux and generation (destruction) of kinetic energy in lower (middle) latitudes.

Chen, T.-C.↗

Informing electrification strategies of residential neighborhoods with urban building energy modeling

Electrifying end uses is a key strategy to reducing GHG emissions in buildings. However, it may increase peak electricity demand that triggers the need to upgrade the existing power distribution system, leading to delays in electrification and needs of significant investment. There is also concern that building electrification may cause an increase of energy costs, leading to further energy burden for low-income communities. This study uses the urban scale building modeling tool CityBES to assess the electrification impacts of more than 43,000 residential buildings in a neighborhood of Portland, Oregon, USA. Energy efficiency upgrades were investigated on their potential to mitigate the increase of peak electricity demand and energy burden. Simulation results from the calibrated EnergyPlus models show that electrification with heat pumps for space heating and cooling as well as for domestic water heating can reduce CO2e emissions by 38%, but increase peak electricity demand by about 9% from the baseline building stock. Combining electrification measures and energy efficiency upgrades can reduce CO2e emissions by 48% while reducing peak electricity demand by 6% and saving the median household energy costs by 28%. City and utility decision makers should consider integrating energy efficiency upgrades with electrification measures as an effective residential building electrification strategy, which significantly reduces carbon emissions, caps or even decreases peak demand while reducing energy burden of residents.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗