Search NASA⌕ Search

SEARCH · Search NASA

Results for “fans”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

In Vivo Entombment of Bacteria and Fungi during Calcium Oxalate, Brushite, and Struvite Urolithiasis

Human kidney stones form via repeated events of mineral precipitation, partial dissolution, and reprecipitation, which are directly analogous to similar processes in other natural and manmade environments, where resident microbiomes strongly influence biomineralization. High-resolution microscopy and high-fidelity metagenomic (microscopy-to-omics) analyses, applicable to all forms of biomineralization, have been applied to assemble definitive evidence of in vivo microbiome entombment during urolithiasis. Stone fragments were collected from a randomly chosen cohort of 20 patients using standard percutaneous nephrolithotomy (PCNL). Fourier transform infrared (FTIR) spectroscopy indicated that 18 of these patients were calcium oxalate (CaOx) stone formers, whereas one patient formed each formed brushite and struvite stones. This apportionment is consistent with global stone mineralogy distributions. Stone fragments from seven of these 20 patients (five CaOx, one brushite, and one struvite) were thin sectioned and analyzed using brightfield (BF), polarization (POL), confocal, super-resolution autofluorescence (SRAF), and Raman techniques. DNA from remaining fragments, grouped according to each of the 20 patients, were analyzed with amplicon sequencing of 16S rRNA gene sequences (V1–V3, V3–V5) and internal transcribed spacer (ITS1, ITS2) regions. Bulk-entombed DNA was sequenced from stone fragments in 11 of the 18 patients who formed CaOx stones, and the patients who formed brushite and struvite stones. These analyses confirmed the presence of an entombed low-diversity community of bacteria and fungi, including Actinobacteria, Bacteroidetes, Firmicutes, Proteobacteria, and Aspergillus niger. Bacterial cells approximately 1 μm in diameter were also optically observed to be entombed and well preserved in amorphous hydroxyapatite spherules and fans of needle-like crystals of brushite and struvite. In conclusion, these results indicate a microbiome is entombed during in vivo CaOx stone formation. Similar processes are implied for brushite and struvite stones. This evidence lays the groundwork for future in vitro and in vivo experimentation to determine how the microbiome may actively and/or passively influence kidney stone biomineralization.

59 BASIC BIOLOGICAL SCIENCES↗

Ozone Gas: Scientific Justification and Practical Guidelines for Improvised Disinfection using Consumer-Grade Ozone Generators and Plastic Storage Boxes

Here, we describe direct measurements of ozone concentration achievable in small enclosed containers (plastic storage boxes) for use as improvised decontamination systems for small articles such as disposable PPE (N95 masks, nitrile gloves, etc.), clothing, mail and small packages, food, and other miscellaneous articles. The emphasis is on the reliable and sustained generation of ozone gas concentrations of sufficient concentration and duration to create an effective virucidal environment to achieve more than 95% to 99% viral inactivation, based upon the data already published in the peer-review literature on this topic. The suggestion that ozone be used to inactivate virus is certainly not a new idea. Our objective in this report is to make clear that the necessary levels of ozone can be improvised using simple, easy-to-use, inexpensive, and widely available supplies, and that there is every theoretical and experimental reason to believe that this approach is as highly effective in viral inactivation by ozone as are the far more expensive, complex, cumbersome, and less available equivalent ozone (and other) disinfectant systems that have themselves become unavailable during times of pandemic crisis. Using multiple types of readily available commercial ozone generators, concentration in the tested improvised enclosure is tracked over time to assess ozone charging and decay rates, and the ozone quenching effects of items placed in the box. Generator performance is compared against published ozone dosage values for virucidal and antimicrobial activity. Bubbler and box-fan-type ozone generators were found to be effective at achieving and maintaining target concentrations of 10ppm ozone or higher, whereas automotive cigarette lighter and universal serial bus type plug in “air freshener” ozone generators could not achieve the target concentrations in these experiments. Calculations and practical guidelines for assembly and effective use of an ozone box for improvised decontamination are offered. The majority of this report is directed toward the scientific justification and rationale for this approach. The end of the document summarizes the findings and offers simplified designs for the construction and use of ozone boxes as an improvised method of disinfection.

60 APPLIED LIFE SCIENCES↗

The Global Magneto-ionic Medium Survey: A Faraday Depth Survey of the Northern Sky Covering 1280–1750 MHz

The Galactic interstellar medium hosts a significant magnetic field, which can be probed through the synchrotron emission produced from its interaction with relativistic electrons. Linearly polarized synchrotron emission is generated throughout the Galaxy and, at longer wavelengths, modified along nearly every path by Faraday rotation in the intervening magneto-ionic medium. Full characterization of the polarized emission requires wideband observations with many frequency channels. We have surveyed polarized radio emission from the Northern sky over the range 1280–1750 MHz, with channel width 236.8 kHz, using the John A. Galt Telescope (diameter 25.6 m) at the Dominion Radio Astrophysical Observatory, as part of the Global Magneto-Ionic Medium Survey. The survey covered 72% of the sky, decl. −30° to +87° at all R.A. The intensity scale was absolutely calibrated, based on the flux density and spectral index of Cygnus A. Polarization angle was calibrated using the extended polarized emission of the Fan Region. Data are presented as brightness temperatures with angular resolution 40′. Sensitivity in Stokes Q and U is 45 mK rms in a 1.18 MHz band. We have applied rotation measure synthesis to the data to obtain a Faraday depth cube of resolution 150 rad m{sup −2} and sensitivity 3 mK rms of polarized intensity. Features in Faraday depth up to a width of 110 rad m{sup −2} are represented. The maximum detectable Faraday depth is ±2 × 10{sup 4} rad m{sup −2}. The survey data are available at the Canadian Astronomy Data Centre.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ion-rich Acceleration during an Eruptive Flux Rope Event in a Multiple Null-point Configuration

We report on the γ-ray emission above 100 MeV from the GOES M3.3 flare SOL2012-06-03. The hard X-ray (HXR) and microwave emissions have typical time profiles with a fast rise to a well-defined peak followed by a slower decay. The >100 MeV emission during the prompt phase displayed a double-peaked temporal structure with the first peak following the HXR and microwaves, and the second one, about 3 times stronger, occurring 17 ± 2 s later. The time profiles seem to indicate two separate acceleration mechanisms at work, where the second γ-ray peak reveals a potentially pure or at least largely dominant ion acceleration. The Atmospheric Imaging Assembly imaging shows a bright elliptical ribbon and a transient brightening in the northwestern (NW) region. Nonlinear force-free extrapolations at the time of the impulsive peaks show closed field lines connecting the NW region to the southeastern part of the ribbon, and the magnetic topology revealed clusters of nulls. These observations suggest a spine-and-fan geometry, and based on these observations, we interpret the second γ-ray peak as being due to the predominant acceleration of ions in a region with multiple null points. The >100 MeV emission from this flare also exhibits a delayed phase with an exponential decay of roughly 350 s. We find that the delayed emission is consistent with ions being trapped in a closed flux tube with gradual escape via their loss cone to the chromosphere.

Pesce-Rollins, Melissa [Istituto Nazionale di Fisi↗

Evidence of Recent Material Transport within a Binary Asteroid System

Images acquired by the Double Asteroid Redirection Test (DART) before its impact into Dimorphos—the moon of the Didymos binary asteroid system—unexpectedly reveal a set of discontinuous rays spanning the imaged surface. These albedo features are visible only after correcting for lighting differences, which normalize the effects of the pervasive boulders that cover the surface. Comparison to physical experiments and numerical simulations shows that these bright, fan-shaped albedo features are consistent with the aftermath of a low-velocity impact into a field of boulders and provide our first direct evidence for the transfer of material in a binary asteroid system due to the shedding material from radiative torques. Parts of these and possible additional albedo markings from the reentry of boulders after the DART impact may be visible to the Hera mission when it explores the post-DART Didymos system.

Astronomy and AstroPhysics↗

An improved mechanistic model for ammonia volatilization in Earth system models: Flow of Agricultural Nitrogen version 2 (FANv2)

Abstract. Volatilization of ammonia (NH 3 ) from fertilizers and livestock wastes forms a significant pathway of nitrogen losses in agricultural ecosystems and constitutes the largest source of atmospheric emissions of NH 3 . This paper describes a major update to the process model FAN (Flow of Agricultural Nitrogen), which evaluates NH 3 emissions interactively within an Earth system model; in this work, the Community Earth System Model (CESM) is used. The updated version (FANv2) includes a more detailed treatment of both physical and agricultural processes, which allows the model to differentiate between the volatilization losses from animal housings, manure storage, grazed pastures, and the application of manure and different types of mineral fertilizers. The modeled ammonia emissions are first evaluated at a local scale against experimental data for various types of fertilizers and manure, and they are subsequently run globally to evaluate NH3 emissions for 2010–2015 based on gridded datasets of fertilizer use and livestock populations. Comparison of regional emissions shows that FANv2 agrees with previous inventories for North America and Europe and is within the range of previous inventories for China. However, due to higher NH 3 emissions in Africa, India, and Latin America, the global emissions simulated by FANv2 (48 Tg N) are 30 %–40 % higher than in the existing inventories.

Vira, Julius↗

A Dual-Mode Hybrid System Combining Solar Thermal With Pumped Thermal Energy Storage

A hybrid system that delivers renewable electricity generation and electricity storage capabilities is introduced. This dual-mode hybrid system is based on Pumped Thermal Energy Storage (PTES) which uses a heat pump to convert electricity into thermal energy that is trans-ferred to silica particles which are stored in concrete silos. The stored heat is later converted back to electricity in a heat engine. The heat pump and heat engine use a closed Joule-Brayton cycle and fluidized bed heat exchangers. If the PTES system is co-located with an array of concentrating solar mirrors and a particle receiver, then the silica particles may also be heated up by the concentrating solar power (CSP) system. The PTES heat engine may also be used to convert the stored solar heat into electricity, thereby sharing this system between the PTES and CSP systems and reducing costs. However, this requires careful management of the heat engine off-design parameters. A thermodynamic model is used to evaluate the performance of the dual mode PTES-CSP hybrid system. The model accounts for turbomachinery effi-ciency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The hybrid system also requires the evaluation of the turbomachinery efficiency and pressure ratio at off-design conditions since the CSP system operates over different temperature ratios than the Carnot Battery. Several design variables and design modifications are investigated, such as pressure ratios and maximum temperatures.

14 SOLAR ENERGY↗

A 1D Lyman-alpha Profile Camera for Plasma Edge Neutral Studies on the DIII-D Tokamak

A one dimensional, absolutely calibrated pinhole camera system was installed on the DIII-D tokamak to measure edge Lyman-alpha (Ly-a) emission from hydrogenic isotopes which can be used to infer neutral density and ionization rate proles. The system is composed of two cameras, each providing a toroidal fan of twenty lines of sight, viewing the plasma edge on the inboard and outboard side of DIII-D. The cameras' views lie in a horizontal plane 77 cm below the midplane. At its tangency radius, each channel provides a radial resolution of approximately 2 cm full width at half maximum (FWHM) with a total coverage of 22 cm. Each camera consists of a rectangular pinhole, Ly-a reflective mirror, narrow-band Ly-a transmission fiter, and a 20 channel AXUV photodetector. The combined mirror and transmission fiter have a FWHM of 5 nm, centered near the Ly-a wavelength of 121.6 nm and is capable of rejecting significant, parasitic carbon-III (C-III) emission from intrinsic plasma impurities. To provide a high spatial resolution measurement in a compact footprint, the camera utilizes advanced engineering and manufacturing techniques including 3D printing, high stability mirror mounts, and a novel alignment procedure. Absolutely calibrated, spatially resolved Ly-a brightness measurements utilize a bright, isolated line with low parasitic surface reflections and enable quantitative comparison to modeling to study divertor neutral leakage, main chamber fueling and radial particle transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Making Better Use of On-Site PV Generation: Direct Distribution of DC Power in Buildings

With the increasing availability of Direct Current (DC) power from on-site solar systems, building designers now have the option of direct distribution of DC power to energy storage systems and end-use loads such as lighting, electronics, and motors. Research shows that direct-DC can reduce building distribution losses by 5-15%, while improving power reliability. A readily available way to implement direct-DC distribution is Power over Ethernet (PoE), which typically has provided low-voltage DC to power office equipment such as WiFi access points. With recent updates to the PoE standard, equipment such as network-controlled LED lighting, thin client and computer workstations, HVAC controllers, fans, motors, and actuators can now be powered by PoE and are commercially available. This paper presents results from a DOE-funded project that is demonstrating PoE technologies and describes a DC modeling and design tool that is intended to help building designers properly evaluate and design DC distribution systems in buildings. The tool provides designers of DC power systems with estimates of both power system losses and indirect effects on building heating and cooling. The results of this research demonstrate that the design methods and products are available to implement DC power in buildings today.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial building loads providing ancillary services In PJM

The adoption of low carbon energy technologies such as variable renewable energy and electric vehicles, coupled with the efficacy of energy efficiency to reduce traditional base load has increased the uncertainty inherent in the net load shape. Handling this variability with slower, traditional resources leads to inefficient system dispatch, and in some cases may compromise reliability. Grid operators are looking to future energy technologies, such as automated demand response (DR), to provide capacity-based reliability services as the need for these services increase. While DR resources are expected to have the flexibility characteristics operators are looking for, demonstrations are necessary to build confidence in their capabilities. Additionally, building owners are uncertain of the monetary value and operational burden of providing these services. To address this, the present study demonstrates the ability of demand response resources providing two ancillary services in the PJM territory, synchronous reserve and regulation, using an OpenADR 2.0b signaling architecture. The loads under control include HVAC and lighting at a big box retail store and variable frequency fan loads. The study examines performance characteristics of the resource: the speed of response, communications latencies in the architecture, and accuracy of response. It also examines the frequency and duration of events and the value in the marketplace which can be used to examine if the opportunity is sufficient to entice building owners to participate.

MacDonald, Jason↗

Process Heating Assessments Using DOE’s Manufacturing Energy Assessment Software for Utility Reduction (MEASUR) Tool Suite

Process heating is the most energy-intensive manufacturing process for most sectors of industry. To quantify energy savings from various energy conservation measures, the Department of Energy (DOE) sponsored the development of the Process Heating Assessment and Survey Tool (PHAST) and similar tools for other industrial systems in the early 2000s. It has been used extensively in the Save Energy Now Program’s Energy Savings Assessments and the Better Plants Program’s In-Plant Trainings. Since the initial development of the legacy tools, both computer operating systems and software development have evolved significantly. Thus, DOE has invested in the modernization of PHAST and other legacy software tools to create the Manufacturing Energy Assessment Software for Utility Reduction (MEASUR) tool suite. MEASUR offers a collection of software tools that can aid manufacturing facilities in improving the efficiency of energy systems and equipment (specifically pumps, fans, steam, and process heating) and in conducting “Energy Treasure Hunts”. Eventually, the tool will also add compressed air and process cooling systems. The Process Heating Assessment (PHA) module of MEASUR is an upgrade of the PHAST tool. PHA provides the means to model fuel-fired, steam-based, and electric process heating systems, covering process heating for most industrial plants in manufacturing sector. It also includes several key upgrades, including the ability to consider multi-component charge loads and account for several different areas of energy losses. The new tool includes a comprehensive flue gas calculator to quantify available heat and heat loss for various gaseous, liquid, and solid fuels and new heat loss calculators. It generates a report and a dynamic Sankey diagram to show the energy consumption in various areas of energy use. MEASUR has significantly improved the user experience by adopting a modern software design. This paper details the structure and workflow of PHA and presents a real-world case study to demonstrate energy savings quantification and MEASUR’s outstanding reporting capabilities.

Nimbalkar, Sachin U.↗

Micro environmental control system

A micro environmental control system that can remove or add 30W from or to the near range personal microenvironment of a user. For cooling, the μX uses a micro vapor compression system during the un-occupied period to freeze a phase-change-material in a thermal storage module. A fan then moves air over the phase-change-material to deliver cooled air. Heating is delivered by a small electric heater integrated into a condensing unit. The resulting system is inexpensive to build and uses a limited amount of energy.

42 ENGINEERING↗

An Approach to High-Performance Affordable Housing Using Point-Source Space Conditioning

In cooperation with the Building America Program, The Levy Partnership explored a variety of options to reduce space-conditioning energy consumption, working with partners to design, manu- facture, and build test homes in three states. The Levy Partnership tested the use of minisplit ductless heat pumps in combi- nation with small through-wall transfer fans to provide space conditioning in small single-story homes, including manufactured homes and homes built by Habitat for Humanity. The team set out to achieve 50% less energy consumption, compared to the 2009 International Energy Conservation Code, while maintaining home afford- ability and thermal comfort. The strategy also included a highly efficient thermal envelope to reduce space-conditioning loads.

30 DIRECT ENERGY CONVERSION↗

Self-powered Heating: Efficiency Analysis

Conventional fuel-fired heating devices such as furnaces, boilers, and water heaters have fuel efficiency less than 100% on the basis of higher heating value. They also require electricity from the electric grid to power parasitic loads such as blowers, pumps, fans, and ignitors. The primary energy efficiency of the device accounts for both fuel used on-site and primary energy used off-site to produce electric power used by the device. This work compares conventional fuel-fired heating devices to two types of self-powered devices. A self-powered device (SPD) integrates a power cycle onboard to eliminate consumption of grid electricity. We assume that all heat rejected by the onboard power cycle is added to the process fluid, so that, compared with a conventional device, the same amount of heat is provided to the process fluid and the same amount of fuel is consumed, but grid electricity consumption is eliminated. The first SPD type is the basic one: exactly the electricity required is generated. The second type considered is the SPD with heat pump (SPD-HP), in which the power cycle generates more electricity than needed for parasitic loads, and the excess electricity is used to power a heat pump. The heat pump extracts additional heat from the ambient to boost efficiency. Both SPD and SPD-HP self-consume all the generated electricity, in contrast to combined heat and power (CHP) systems that export electricity. In this work, equations are derived to express the efficiency of three classes of heating devices: conventional (consuming grid electricity), self-powered (consuming no grid electricity), and self-powered with heat pump. The efficiency of each is derived as a function of up to six factors: (1) the fraction of combustion heat captured, (2) the rate of parasitic power consumption, (3) the fraction of electric energy dissipated as useful heat, (4) the power cycle conversion efficiency, (5) the grid efficiency, when applicable, and (6) the heat pump COP, when applicable. Scenarios are identified in which it is possible to achieve efficiency greater than 100% on a higher heating value basis. Plausible configurations using existing technology options are outlined.

Gluesenkamp, Kyle↗

Numerical Investigation of Two-Stage Vapor Compression System with Simultaneous Vapor and Liquid Injection

Two-stage vapor compression systems can be advantageous over single-stage systems by providing improved system performance, lower discharge temperature and reduced throttling losses. These systems employ various intermediate configurations, such as liquid injection and vapor injection. This paper presents a configuration for a R1234ze(E) two-stage air-conditioning system using a turbo compressor with two injection ports, one for vapor injection and the second for liquid injection. The liquid injection is used to cool the motor and electronics. A component-based representation and solution approach was used to simulate the two-stage compression system with simultaneous vapor and liquid injection at steady state. The turbo compressor was represented using a customized performance map. The condenser and the evaporator were modeled using finite-volume approach. A parametric study was conducted to assess the impact of the following three variables on the system performance: vapor injection ratio, condenser air flow rate, and discharge pipe pressure drop. The simulation results show that as the vapor injection ratio increased, the system performance undergoes a tradeoff between an enhanced subcooling effect (and thus enhanced unit refrigeration capacity) and a decreased suction mass flow rate. Maximum COP occurs when the vapor injection ratio was 0.1. The results also show that as the condenser air flow rate increased, both the capacity and power consumption (including fan power) increased monotonically, and COP increased first and then decreased. At 75% load, the COP improvement at the optimum flow rate was marginally less than 0.5%. Lastly, higher discharge pipe pressure drop increased the discharge pressure. It showed very small effect on the overall system performance at the condition selected for the current study.

component-based steady-state simulation↗

Cooling methods for medium voltage drive systems

In one aspect, a medium voltage power converter includes a cabinet having: a power cube bay to house a plurality of power cubes, each of the plurality of power cubes adapted within a corresponding enclosure and comprising a low frequency front end stage, a DC link and a high frequency back end stage, the plurality of power cubes to couple to a high speed machine; and a plurality of first barriers adapted to isolate and direct a first flow of cooling air through one of the plurality of power cubes; and a transformer bay having at least one transformer to couple between a utility connection and the plurality of power cubes, the transformer bay including a plurality of cooling fans to cool the at least one transformer.

Ledezma, Enrique↗

Draft Environmental Impact Statement for Proposed Energy Conservation Standards for Manufactured Housing

This draft environmental impact statement (EIS) analyzes the impacts related to DOE’s proposed energy conservation standards for manufactured homes. DOE’s proposed energy conservation standards are based on the 2021 International Energy Conservation Code (IECC) and relate to the building thermal envelope; air sealing; installation of insulation; duct sealing; heating, ventilation and air conditioning (HVAC); service hot water systems; mechanical ventilation fan efficacy; and heating and cooling equipment sizing. The draft EIS evaluates DOE’s proposed action (energy conservation standards tiered based the manufacturers retail list price), alternatives to the proposed action (including energy conservation standards tiered based on size of the manufactured home and untiered standards), and a no action alternative. The draft EIS presents analysis of impacts related to (1) energy resources; (2) air resources (including greenhouse gases, climate change, ambient air quality and indoor air quality); (3) health and safety; (4) socioeconomics; and (5) environmental justice.

MacDonell, Margaret↗

Critical Analysis of Replacements for R-410A in Heat Pump Applications

Using low-GWP refrigerants can reduce the Green House Gas (GHG) emission of HVAC systems. Research has shown that using heat exchangers with small diameter tubes is a promising solution to meet the performance goals of heat pump using low-GWP refrigerants due to reduced refrigerant charge, reduced flammable impact and environmental impact. However, application of small diameter tube requires in-depth component design optimization to make the new system adapt to low-GWP refrigerants.In this paper, multi-objective optimizations using Particle Swarm Optimization (PSO) algorithm on a R-410A residential 5-ton air source heat pump is performed for improved system performance and reduced material cost. Five R-410A alternatives, i.e., R-32, R-454A, R-454B, R-454C and R-455A are investigated. R-455A and R-454C have GWP lower than 150. As a result of optimization, 12.4%-19.1% Energy Efficiency Ratio (EER) improvement and up to 71% HXs material cost saving is achieved. Life Cycle Climate Performance (LCCP) analysis shows that optimized systems reduce total CO2 emission by 13%-33% depending on the choice of refrigerant and climate zone.The optimal heat exchangers resulting from this research can fit into the original R-410A fan-coil units. The proposed heat pump design method establishes a production and installation path to produce cost-effective low-GWP heat pumps easily accepted by end users.

Li, Zhenning↗