Space Shuttle SRM internal flows

Flow-visualization techniques were employed in a 1/8-scale model of the Shuttle SRM to investigate the dominant SRM internal flow patterns. The mode included the two aft segments, the aft dome, and the convergent portion of the gimballed nozzle. The effects of 'blowing', resulting from gases produced by the burning propellant, were simulated through the introduction, of a uniform distribution of water along simulated burn-back patterns representing the surface at three different times in a firing. It was found that the effects of vortices shed from protruding inhibitor sections were greatly diminished by the effects of wall injection. It was also found that the extent of circumferential flow resulting from the removal of a portion of protruding inhibitor was limited in scope. Strong circumferential flow in the aft dome was observed when no grain surface was present in the dome. This flow included nozzle-entrance vortices, the occurrence of which probably resulted from interactions between the submerged-nozzle flow and the boundary-layer flow in the aft dome of the case.

Waesche, R. H. Woodward↗

Effect of soot concentration on radiative transport in a 2 m JP-8 pool fire

Hubbard et al. (2024) investigated conjugate heat transfer in a 7.9 m JP-8 pool fire, utilizing both heavily sooting and non-sooting fuel models. Their findings indicated that all models produced pool radiative heat fluxes within the measurement uncertainty for large-scale outdoor experiments. This study aims to further investigate the influence of soot concentration on radiative transport. To this end, Large Eddy Simulations (LES) of a 2 m diameter JP-8 pool fire were conducted, employing four turbulent combustion chemistry models: the Eddy Dissipation Concept (EDC) and three variants of flamelet model. Additionally, three variations of the one-equation subgrid scale turbulence kinetic energy model, and multiple mesh resolutions were utilized. The primary validation metrics were pool radiative heat flux and plume radiative fraction, with simulation data compared to experimental results published by Blanchat et al. (2010). The EDC model produced high soot concentrations near the pool surface, resulting in a significant shielding effect. In contrast, the flamelet combustion model has different kinetic limiters for soot production, leading to soot formation higher in the flame, where it can be more readily oxidized. Flamelet models incorporating both acetylene and benzene contributions to soot growth demonstrated better agreement with experimental data. To assess the sensitivity of pool radiative heat flux to soot mass concentration, we used a one-dimensional approximation over a wide range of soot concentrations and compared it to three-dimensional solutions obtained using Discrete Ordinates. Furthermore, this analysis illustrates the impacts of soot shielding and Turbulence Radiation Interactions (TRI), with TRI emission enhancement factors predicted to be in the range of 3–5 near the edges of the plume.

Computational fluid dynamics↗

New fire retardant foams and intumescents

The development of fire retardant foams and intumescent paints for protection of commercial aircraft passengers in the event of fire is discussed. Recommended materials and methods for evaluating the effectiveness of the materials are presented. Typical problems resulting from aircraft fires and the basic protective mechanisms to cope with these problems are examined.

Parker, J. A.↗

STABILITY TESTS OF MONOPROPELLANTS EXPOSED TO FLAMES AND RIFLE FIRE

Tests of the stability of several monopropellants under the effects of impact and heat were conducted in order to assess the potential hazard in a propellant storage area from major fires and enemy attack. Hydrazine, hydrazine nitrate solution, n-propyl nitrate, and ethylene oxide were all tested in one-gallon aluminum containers (half of them filled to 25% and half to 95% capacity) by being subjected to oil bonfires and wood bonfires, and 20-mm incendiary, 20mm high explosive incendiary, and .30-caliber rifle fire. Aviation gasoline was tested in the same manner, for comparison. In the bonfire tests, all four monopropellants generally gave explosion intensities equivalent to one another regardless of the type of bonfire (oil or wood) or the amount of liquid in the test container. Occasionally, however, with hydrazine, hydrazine nitrate solution, and n-propyl nitrate, anomalous results occurred: there was either (a) no explosion or (b) an explosion of above average intensity. Ethylene oxide more nearly approximated the behavior of aviation gasoline than did the other monopropellants. In the rifle-fire tests, n-propyl nitrate appeared to be most shock- sensitive since it was exploded by all three types of ammunition. Hydrazine and hydrazine nitrate solution were exploded by the high-explosive ammunition, but not by the incendiary or .30-dber ammunition. Ethylene oxide was not exploded by any of the gunfire, but the liquid was ignited by both incendiary and high-explosive incendiary ammunition.

FIRING↗

In-time Safety Management Capabilities for Wildland Fire Management Aircraft Operations - A Gap Assessment

This study assesses the in-time safety management services, functions, and capabilities (SFCs)being investigated by NASA’s System Wide Safety (SWS) project to determine applicability to the project’s planned safety demonstrator (SD-1) for wildland fire management. The purpose of this work is to evaluate how effectively existing SFCs address the different hazards presented by a safety demonstrator operating in a wildland fire management scenario. This will help inform decision makers which SFCs would provide the most cost-effective solutions to fill the hazard gaps for further research. Hazards for the safety demonstrator wildland fire management scenario were collated, and the SFCs were evaluated for each hazard based on how applicable and effective the unmodified SFCs are at addressing the hazard. The SFCs are also evaluated for the gap type that needs to be addressed to improve the SFC effectiveness for the given hazard. The key finding of this assessment is that all the existing SFCs require at least some research and development to adapt to the safety demonstrator. No single SFC fully addresses any of the safety demonstrator operation hazards. The result of this study will be used to determine the performance of current SFCs and suggest strategies to adapt existing SFCs or add new SFCs.

Patricia Revolinsky↗

The geographical distribution of lightning: Forestry and range requirements and interests

In an attempt to reduce the response time of the initial attack forces to lightning-caused fire, a lightning detection system that effectively locates accurate directions to lightning discharges to over 200 miles from the detection equipment was developed. The system was first tested in Alaska in 1975. Since that time, further development and operational testing led to the implementation of wide area networks. For the 1979 fire season an eight station network in Alaska is to be implemented that will cover virtually all of the lightning-caused fire areas in the state. In the western United States, an eighteen station network that will cover approximately 85% of eleven states is to be implemented. For the first time, large scale ground discharge lightning distribution information is to be available.

Vance, D. L.↗

Fire extinguishment and inhibition in spacecraft environments

It was concluded that it is essential that NASA develop a comprehensive approach to fire extinguishment and inerting in spacecraft environments. Electronic equipment might be easily protected through use of an onboard inert gas generating system. The use of Halon 1301 presents serious technological challenges for agent cleanup and removal of the toxic and corrosive products of combustion. Nitrogen pressurization, while effective, probably presents a serious weight penality. The use of liquid water sprays appears to be the most effective approach to general purpose spacecraft fire protection.

Deris, John↗

Climate Change-Induced Peatland Drying in Southeast Asia

When organic peat soils are sufficiently dry, they become flammable. In Southeast Asian peatlands, widespread deforestation and associated drainage create dry conditions that, when coupled with El Niño-driven drought, result in catastrophic fire events that release large amounts of carbon and deadly smoke to the atmosphere. While the effects of anthropogenic degradation on peat moisture and fire risk have been extensively demonstrated, climate change impacts to peat flammability are poorly understood. These impacts are likely to be mediated primarily through changes in soil moisture. Here, we used neural networks (trained on data from the NASA Soil Moisture Active Passive satellite) to model soil moisture as a function of climate, degradation, and location. The neural networks were forced with regional climate model projections for 1985–2005 and 2040–2060 climate under RCP8.5 forcing to predict changes in soil moisture. We find that reduced precipitation and increased evaporative demand will lead to median soil moisture decreases about half as strong as those observed during recent El Niño droughts in 2015 and 2019. Based on previous studies, such reductions may be expected to accelerate peat carbon emissions. Our results also suggest that soil moisture in degraded areas with less tree cover may be more sensitive to climate change than in other land use types, motivating urgent peatland restoration. Climate change may play an important role in future soil moisture regimes and by extension, future peat fire in Southeast Asian peatlands.

VIIRS↗

Experimental Observations on a Low Strain Counter-Flow Diffusion Flame: Flow and Bouyancy Effects

Diffusion flames are of great interest in fire safety and many industrial processes. The counter-flow configuration provides a constant strain flow, and therefore is ideal to study the structure of diffusion flames. Most studies have concentrated on the high velocity, high strain limit, since buoyantly induced instabilities will disintegrate the planar flame as the velocity decreases. Only recently, experimental studies in microgravity conditions have begun to explore the low strain regimes. Numerical work has shown the coupling between gas phase reaction rates, soot reaction rates, and radiation. For these programs, size, geometry and experimental conditions have been chosen to keep the flame unaffected by the physical boundaries. When the physical boundaries can not be considered infinitely far from the reaction zone discrepancies arise. A computational study that includes boundary effects and accounts for the deviations occurring when the major potential flow assumptions are relaxed was presented by Borlik et al. This development properly incorporates all heat loss terms and shows the possibility of extinction in the low strain regime. A major constraint of studying the low strain regime is buoyancy. Buoyant instabilities have been shown to have a significant effect on the nature of reactants and heat transport, and can introduce instabilities on the flow that result in phenomena such as flickering or fingering. The counter-flow configuration has been shown to provide a flame with no symmetry disrupting instabilities for inlet velocities greater than 50 mm/s. As the velocity approaches this limit, the characteristic length of the experiment has to be reduced to a few millimetres so as to keep the Rayleigh number (Ra L = (β g 0 L 3 ∆T)/(𝑎v)) below 2000. In this work, a rectangular counter-flow burner was used to study a two-dimensional counter-flow diffusion flame. Flow visualisation and Particle Image Velocimetry served to describe the nature of the stagnation plane for strain rates smaller than 100 (1/s). These experiments were conducted with a non-reacting flow. Video images of a propane air diffusion flame were used to describe the behaviour of a diffusion flame in this regime. Flame geometry and pulsation frequency are described.

J. A. Sutula↗

Spiking Neurons for Analysis of Patterns

Artificial neural networks comprising spiking neurons of a novel type have been conceived as improved pattern-analysis and pattern-recognition computational systems. These neurons are represented by a mathematical model denoted the state-variable model (SVM), which among other things, exploits a computational parallelism inherent in spiking-neuron geometry. Networks of SVM neurons offer advantages of speed and computational efficiency, relative to traditional artificial neural networks. The SVM also overcomes some of the limitations of prior spiking-neuron models. There are numerous potential pattern-recognition, tracking, and data-reduction (data preprocessing) applications for these SVM neural networks on Earth and in exploration of remote planets. Spiking neurons imitate biological neurons more closely than do the neurons of traditional artificial neural networks. A spiking neuron includes a central cell body (soma) surrounded by a tree-like interconnection network (dendrites). Spiking neurons are so named because they generate trains of output pulses (spikes) in response to inputs received from sensors or from other neurons. They gain their speed advantage over traditional neural networks by using the timing of individual spikes for computation, whereas traditional artificial neurons use averages of activity levels over time. Moreover, spiking neurons use the delays inherent in dendritic processing in order to efficiently encode the information content of incoming signals. Because traditional artificial neurons fail to capture this encoding, they have less processing capability, and so it is necessary to use more gates when implementing traditional artificial neurons in electronic circuitry. Such higher-order functions as dynamic tasking are effected by use of pools (collections) of spiking neurons interconnected by spike-transmitting fibers. The SVM includes adaptive thresholds and submodels of transport of ions (in imitation of such transport in biological neurons). These features enable the neurons to adapt their responses to high-rate inputs from sensors, and to adapt their firing thresholds to mitigate noise or effects of potential sensor failure. The mathematical derivation of the SVM starts from a prior model, known in the art as the point soma model, which captures all of the salient properties of neuronal response while keeping the computational cost low. The point-soma latency time is modified to be an exponentially decaying function of the strength of the applied potential. Choosing computational efficiency over biological fidelity, the dendrites surrounding a neuron are represented by simplified compartmental submodels and there are no dendritic spines. Updates to the dendritic potential, calcium-ion concentrations and conductances, and potassium-ion conductances are done by use of equations similar to those of the point soma. Diffusion processes in dendrites are modeled by averaging among nearest-neighbor compartments. Inputs to each of the dendritic compartments come from sensors. Alternatively or in addition, when an affected neuron is part of a pool, inputs can come from other spiking neurons. At present, SVM neural networks are implemented by computational simulation, using algorithms that encode the SVM and its submodels. However, it should be possible to implement these neural networks in hardware: The differential equations for the dendritic and cellular processes in the SVM model of spiking neurons map to equivalent circuits that can be implemented directly in analog very-large-scale integrated (VLSI) circuits.

Huntsberger, Terrance↗

High-Temperature Oxidation Behavior of Wrought and Additive Manufactured H282 in Direct-Fired Supercritical CO2 Power Cycle Environments

Materials selection is a key concern for corrosion resistance in high temperature and pressure direct-fired supercritical CO2 power cycles. The effect of elevated pressure on corrosion resistance can be critical, as impurities within the supercritical fluid such as H2O and O2 can result in additional corrosion behaviors. Utilizing additive manufacturing (AM) methods for construction of power cycle components requiring both compact and complex designs could be advantageous. AM H282 produced by laser powder bed fusion was exposed to direct-fired conditions (95CO2 – 4H2O – 1 O2) at 750 °C at both atmospheric pressure and supercritical conditions (20 MPa) for up to 4,000 hours. Oxidation behavior, sub-surface carbide formation, and chromia scale volatilization was dependent upon AM preparation techniques and surface modifications. These results are discussed in terms of the potential compatibility issues that may arise when using AM alloys in high temperature regions of direct-fired sCO2 power cycles, particularly for thin-walled components.

Carney, Casey↗

Advanced spacecraft fire safety: Proposed projects and program plan

A detailed review identifies spacecraft fire safety issues and the efforts for their resolution, particularly for the threats posed by the increased on-orbit duration, size, and complexity of the Space Station Freedom. Suggestions provided by a survey of Wyle consultants and outside fire safety experts were combined into 30 research and engineering projects. The projects were then prioritized with respect to urgency to meet Freedom design goals, status of enabling technology, cost, and so on, to yield 14 highest priority projects, described in terms of background, work breakdown structure, and schedule. These highest priority projects can be grouped into the thematic areas of fire detection, fire extinguishment, risk assessment, toxicology and human effects, and ground based testing. Recommendations for overall program management stress the need for NASA Headquarters and field center coordination, with information exchange through spacecraft fire safety oversight committees.

Youngblood, Wallace W.↗

Trace Gas Measurements in Nascent, Aged and Cloud-processed Smoke from Africa Savanna Fires by Airborne Fourier Transform Infrared Spectroscopy (AFTIR)

We measured stable and reactive trace gases with an airborne Fourier transform infrared spectrometer (AFTIR) on the University of Washington Convair-580 research aircraft in August/September 2000 during the SAFARI 2000 dry season campaign in Southern Africa. The measurements included vertical profiles of C02, CO, H20, and CH4 up to 5.5 km on six occasions above instrumented ground sites and below the TERRA satellite and ER-2 high-flying research aircraft. We also measured the trace gas emissions from 10 African savanna fires. Five of these fires featured extensive ground-based fuel characterization, and two were in the humid savanna ecosystem that accounts for most African biomass burning. The major constituents we detected in nascent CH3OOH, HCHO, CH30H, HCN, NH3, HCOOH, and C2H2. These are the first quantitative measurements of the initial emissions of oxygenated volatile organic compounds (OVOC), NH3, and HCN from African savanna fires. On average, we measured 5.3 g/kg of OVOC and 3.6 g/kg of hydrocarbons (including CH4) in the initial emissions from the fires. Thus, the OVOC will have profound, largely unexplored effects on tropical tropospheric chemistry. The HCN emission factor was only weakly dependent on fire type; the average value (0.53 g/kg) is about 20 times that of a previous recommendation. HCN may be useful as a tracer for savanna fires. Delta O3/Delta CO and Delta CH3COO/Delta CO increased to as much as 9% in <1 h of photochemical processing downwind of fires. Direct measurements showed that cloud processing of smoke greatly reduced CH30H, NH3, CH3COOH, SO2, and NO2 levels, but significantly increased HCHO and NO.

Yokelson, Robert J.↗

Improving Nocturnal Fire Detection with the VIIRS Day-Night Band

Building on existing techniques for satellite remote sensing of fires, this paper takes advantage of the day-night band (DNB) aboard the Visible Infrared Imaging Radiometer Suite (VIIRS) to develop the Firelight Detection Algorithm (FILDA), which characterizes fire pixels based on both visible-light and infrared (IR) signatures at night. By adjusting fire pixel selection criteria to include visible-light signatures, FILDA allows for significantly improved detection of pixels with smaller and/or cooler subpixel hotspots than the operational Interface Data Processing System (IDPS) algorithm. VIIRS scenes with near-coincident Advanced Spaceborne Thermal Emission and Reflection (ASTER) overpasses are examined after applying the operational VIIRS fire product algorithm and including a modified "candidate fire pixel selection" approach from FILDA that lowers the 4-μm brightness temperature (BT) threshold but includes a minimum DNB radiance. FILDA is shown to be effective in detecting gas flares and characterizing fire lines during large forest fires (such as the Rim Fire in California and High Park fire in Colorado). Compared with the operational VIIRS fire algorithm for the study period, FILDA shows a large increase (up to 90%) in the number of detected fire pixels that can be verified with the finer resolution ASTER data (90 m). Part (30%) of this increase is likely due to a combined use of DNB and lower 4-μm BT thresholds for fire detection in FILDA. Although further studies are needed, quantitative use of the DNB to improve fire detection could lead to reduced response times to wildfires and better estimate of fire characteristics (smoldering and flaming) at night.

Day-night band↗

NFPA Distributed Energy Resources Safety Training (DERST) For Emergency Responders

The National Fire Protection Association, with support from the Department of Energy, executed a multi-year initiative to develop, enhance, and disseminate Distributed Energy Resources Safety Training (DERST) tools for U.S. emergency responders. As Distributed Energy Resources (DER)—such as solar photovoltaics, battery energy storage systems (ESS), electric vehicles (EVs), and associated infrastructure—become increasingly prevalent, the NFPA identified a critical need for up-to-date standardized, accessible, and effective safety training tailored for the fire service and related public safety professionals. The project delivered a comprehensive suite of educational resources to improve responders’ abilities to safely manage DER-related incidents. This included: • Revised Modular Training Courses: Updated classroom-based DER safety courses, now modular and accessible nationwide through fire academies and the North American Fire Training Directors (NAFTD) network. • Live Burn Testing & Research: A full-scale controlled burn of a DER-equipped residential structure provided real-world data and insights, forming the basis for updated best practices. • A Gamified Simulation Tool – Firefighters Incident Response Simulation Tool (FIRST): A first-of-its-kind, multiplayer, scenario-based simulation using the Unreal Engine 5.0 to train responders in a realistic virtual, multi-DER incident environment. • Field Familiarization Software Tools & Prop Guide: Digital DER field familiarization evolutions software guide and a prop development manual to support field-based DER training exercises, enhancing responders' hands-on familiarity with DER infrastructure and collaboration on virtual incident responses. • National Dissemination Strategy: Strategic partnerships with NAFTD, Vector Solutions, and others enabled wide-scale distribution, with over 5,000 departments accessing resources and 1,100+ departments adopting the simulator in the first seven months. Also provided a web portal for easy access to all training and simulation programs developed under this grant for the U.S. responder community. Key findings from the project—particularly from the burn test—led to paradigm shifts in fire response tactics. For example, traditional approaches to garage fires may be hazardous if DERs are present, due to explosive off gassing and thermal runaway risks. The new training emphasizes scene assessment, stand-off approaches, thermal imaging verification, and careful post-incident cooling of DER components to prevent reignition. This initiative has had a significant national impact, raising awareness, enhancing preparedness, and supporting safer DER incident response practices. Significant engagement from the media, public safety organizations, and PBS coverage has further amplified the reach and adoption of NFPA’s DER safety training, tools, and simulations.

14 SOLAR ENERGY↗

Space Experiment Concepts: Cup-Burner Flame Extinguishment

Space Fire Suppression Processes & Technology. Space experiment concepts of cup-burner flame extinguishment have been conceived to address to the key issues (i.e., organizing questions) in space fire suppression. Cup-burner flame extinguishment experiment can reveal physical and chemical suppression processes and provide agent effectiveness data useful for technology development of space fire suppression systems in various reduced-gravity platforms.

Takahashi, Fumiaki↗

Behavior of Windblown Sand on Mars: Results from Single-Particle Experiments

Experiments are investigating the behavior of individual sand grains in the high-energy martian aeolian regime. Energy partitioning during impact of a saltating grain determines grain longevity, but it also influences the way in which the bed becomes mobilized by reptation. When single grains of sand are fired into loose beds, the bed can absorb up to 90% of the impact energy by momentum transfer to other grains; it has been discovered that the impacting grains cause circular craters even at low impact angles. Hundreds of grains can be splashed by a single high-velocity (100 m/s) impact causing more bed disturbance through reptation than previously thought. The research is supported by NASA's PG&G Program. Because the martian aeolian environment in both high energy and of long duration, the most mobile fractions of windblown sand should have eradicated themselves by attrition, unless sand supply has kept pace with destruction. It is therefore important to understand the rate of grain attrition in order to make sense of the existence of vast dune fields on Mars. Attrition, has been addressed in other studies, but precise data for a single saltating grain striking a loose bed of sand have not been acquired -- the quintessential case to be understood for dunes on Mars. To acquire these data, we are employing a compound crossbow which has the bolt-firing mechanism replaced with a pneumatically-automated sabot system. The sabot can launch individual grains of sand of any size between several millimeters and about 50 microns, at velocities up to 100m/s. This is around the maximum velocity expected for saltating grains on Mars. The sabot sled is equipped with photoelectric sensors for measuring shot velocity. Baffling of the grain's exit orifice has enabled projection of single grains without significant aerodynamic effects from the sabot. Grains are fired into loose beds of sand at about 15 degrees from the horizontal (typical saltation trajectory at impact) while being filmed on high-speed video. High-intensity pulse illumination for the grains is triggered by the solenoid-operated bow trigger. A 45 degree mirror over the impact site provides simultaneous horizontal and vertical images of the impact on each video frame. UV fluorescence is enabling grain and grain-fragment recovery. At 100 m/s, grains of all sizes shatter into many fragments when the sand is replaced with a solid target. Kinetic energy of the grains at this velocity exceeds the critical energy for catastrophic failure of minerals. Although probably exceptional as a grain speed, it suggests that conditions on Mars might elevate materials into an attrition regime not encountered on other planets; individual grains blown across rock pavements on Mars will have short lifespans. When experimental grains impact loose (dune) sand, much, if not most of the kinetic energy is converted into momentum of other grains. Using high-speed filming, the energy involved in splashing grains at the impact site can be derived from the size of the crater, the speed of the splashed grains, and the rebound speed of the impactor. The amount of energy partitioned into material failure (as opposed to momentum) is too small a fraction of the total to be calculated under these circumstances. This does not necessarily mean that little damage occurs to the grains (the full extent of the damage has yet to be determined) because only a small fraction of the impact energy is required for inducing brittle fracture. Damage is orders of magnitude less than during impact against solid surfaces.

Marshall, J. R.↗

Proposition to Optimize Fire Stations for Wildfires

The rising trend in wildfire occurrence and severity has put a strain on wildfire management organizations by spreading out limited resources to meet increasing demand. There has been extensive prior research and data collection to determine the areas of highest risk and to predict regional wildfire damages based on historical trends. Our group aims to utilize this data to best determine fire station placement, optimizing where resources are allocated to reduce the time and investment needed to effectively mitigate wildfires. Using existing research, we are able to calculate optimal fire station locations by utilizing a single-objective facility location problem algorithm incentivized for cost reduction. Further work would be needed to refine the algorithm to accommodate for more realistic factors including access to water and roadways as well as better accounting for the costs involved, but our work serves as a proof of concept and lays the foundation for future research. Implementation of this algorithm would allow public fire planning agencies (such as CAL FIRE and Forest Service) to shift resources to where they would be most effective.