Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluid loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Vapor Compression Distillation Subsystem (VCDS) component enhancement, testing and expert fault diagnostics development, volume 1

Vapor compression distillation technology for phase change recovery of potable water from wastewater has evolved as a technically mature approach for use aboard the Space Station. A program to parametrically test an advanced preprototype Vapor Compression Distillation Subsystem (VCDS) was completed during 1985 and 1986. In parallel with parametric testing, a hardware improvement program was initiated to test the feasibility of incorporating several key improvements into the advanced preprototype VCDS following initial parametric tests. Specific areas of improvement included long-life, self-lubricated bearings, a lightweight, highly-efficient compressor, and a long-life magnetic drive. With the exception of the self-lubricated bearings, these improvements are incorporated. The advanced preprototype VCDS was designed to reclaim 95 percent of the available wastewater at a nominal water recovery rate of 1.36 kg/h achieved at a solids concentration of 2.3 percent and 308 K condenser temperature. While this performance was maintained for the initial testing, a 300 percent improvement in water production rate with a corresponding lower specific energy was achieved following incorporation of the improvements. Testing involved the characterization of key VCDS performance factors as a function of recycle loop solids concentration, distillation unit temperature and fluids pump speed. The objective of this effort was to expand the VCDS data base to enable defining optimum performance characteristics for flight hardware development.

Kovach, L. S.↗

Thermal management of advanced fuel cell power systems

It is shown that fuel cell devices are particularly attractive for the high-efficiency, high-reliability space hardware necessary to support upcoming space missions. These low-temperature hydrogen-oxygen systems necessarily operate with two-phase water. In either PEMFCs (proton exchange membrane fuel cells) or AFCs (alkaline fuel cells), engineering design must be critically focused on both stack temperature control and on the relative humidity control necessary to sustain appropriate conductivity within the ionic conductor. Water must also be removed promptly from the hardware. Present designs for AFC space hardware accomplish thermal management through two coupled cooling loops, both driven by a heat transfer fluid, and involve a recirculation fan to remove water and heat from the stack. There appears to be a certain advantage in using product water for these purposes within PEM hardware, because in that case a single fluid can serve both to control stack temperature, operating simultaneously as a heat transfer medium and through evaporation, and to provide the gas-phase moisture levels necessary to set the ionic conductor at appropriate performance levels. Moreover, the humidification cooling process automatically follows current loads. This design may remove the necessity for recirculation gas fans, thus demonstrating the long-term reliability essential for future space power hardware.

Vanderborgh, N. E.↗

Comprehensive Testing of a Neon Cryogenic Capillary Pumped Loop

This paper describes a comprehensive test program of a cryogenic capillary pumped loop (CCPL) using neon as the working fluid in the temperature range between 30 K and 40 K. The test article was originally designed to be used with nitrogen in the 70 K to 100 K temperature range, and was refurbished for testing with neon. Tests performed included start up from a supercritical state, power cycle, sink temperature cycle, heat transport limit, low power limit, reservoir set point change and long duration operation. The neon CCPL has demonstrated excellent performance under various conditions.

Kobel, Mark C.↗

SERFE Thermal Performance Results

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is underdevelopment to support missions to the International Space Station (ISS) and also to the Moon. Improvements in the life and robustness of the Portable Life Support System (PLSS) has been a major objective of these efforts. The Suit Water Membrance Evaporator (SWME) was chosen as the technology to provide cooling to the xEMU and has undergone several iterations of development over this period. An ISS flight experiment centered around the SWME and other thermal loop technologies was developed and has been under test in an ISS EXpedite PRocessing of Experiments to the Space Station (EXPRESS) rack since November of 2020. In addition to the SWME, The SWME EXPRESS Rack Flight Experiment (SERFE) contains several technology demonstrations from the xEMU project and has been demonstrating their performance in micro-gravity and over an extended duration. In addition to the SWME, these include two dissimilar water pumps, custom check valves, custom bypass relieve valves, a custom thermal control valve, development pressure and temperature sensors, and the Thermal Loop Controller. This paper presents thermal and fluids testing results of the system as a whole and of key components.

SERFE↗

Experimentation on Finned-Tube Microchannel Heat Exchanger Incorporating Phase Change Material and R-410A

Integrating latent heat thermal energy storage, particularly phase change materials (PCM), in building heating, ventilation, air conditioning, and refrigeration (HVAC&R) systems, offers substantial benefits for peak load shifting and energy efficiency. While numerous studies explore PCM-embedded heat exchangers (PCM-HX) using single-phase heat transfer fluids, there needs to be more investigation regarding PCM-HX utilizing two-phase refrigerant flow. This gap is even more pronounced for microchannel heat exchanger (MCHX) configurations. In this study, an MCHX-based PCM-HX was built and tested to analyze and evaluate the performance of a PCM-HX operating with a two-phase refrigerant as the working fluid. A commercially available MCHX condenser unit was embedded with 2.6 kg of RT35 PCM and tested using R-410A as the working fluid, using an in-house test loop to control the refrigerant inlet conditions precisely. Thin and minimally invasive T-type thermocouples traced the temperature evolution along MCHX channels and tube banks. Additional larger T-type thermocouple probes at the refrigerant inlet and outlet measured the average power of the PCM-HX during condensing tests, ranging from 0.7 kW to 1.6 kW based on mass flow rates varying from 3.5 g/s to 8 g/s. This experimental study on MCHX-based PCM-HX with a two-phase refrigerant has the potential to offer practical design guidelines for the direct integration of PCM-TES in HVAC&R systems without the use of a secondary loop, while caution is advised to avoid a substantial increase in the refrigerant charge amount.

42 ENGINEERING↗

Results of closed cycle MHD power generation tests with a helium-cesium working fluid

The cross-sectional dimensions of the MHD channel in the NASA Lewis closed loop facility have been reduced to 3.8 x 11.4 cm. Tests were run in this channel using a helium-cesium working fluid at stagnation pressures of 1.6 x 10 to the 5th N/sq m, stagnation temperatures of 2000-2060 K and an entrance Mach number of 0.36. In these tests Faraday open circuit voltages of 200 V were measured which correspond to a Faraday field of 1750 V/m. Power generation tests were run for different groups of electrode configurations and channel lengths. Hall fields up to 1450 V/m were generated. Power extraction per electrode of 183 W and power densities of 1.7 MW/cu m have been obtained. A total power output of 2 kW was generated for tests with 14 electrodes. The power densities obtained in this channel represent a factor of 3 improvement over those reported for the m = 0.2 channel at the last EAM Symposium.

Sovie, R. J.↗

Evolution of electron and proton temperatures in a flaring loop. I - A case of thermal heating of electrons

A temperature difference between electrons and protons produced in a flaring loop was investigated experimentally by adopting a one-fluid, two-temperature model instead of a single-temperature model. Consideration was given to the case in which flare energy is released in the form of heating of electrons located in the top part of the loop. In this case, a large temperature difference appears in the corona in the energy-input phase of the flare. When the material evaporated from the chromosphere fills the corona, the temperature difference in the loop begins to shrink rapidly from below. Eventually, in the loop apex, the proton temperature exceeds the electron temperature mainly due to cooling of the electrons by conduction down the loop and heating of the protons by compression of the ascending material. In the late phase of the flare (about 15 min from the flare onset), the temperature difference becomes less than 2 pct of the mean temperature of electrons and protons at every point in the loop.

Nagai, F.↗

High-Power Liquid-Metal Heat-Transfer Loop

Proposed closed-loop system for transfer of thermal power operates at relatively high differential pressure between vapor and liquid phases of liquid-metal working fluid. Resembles "capillary-pumped" liquid-metal heat-transfer loop except electric field across permselective barrier of beta alumina keeps liquid and vapor separate at heat-input end. Increases output thermal power, contains no moving parts, highly reliable and well suited to long-term unattended operation.

Bhandari, Pradeep↗

The evolution of soft X-ray-emitting flare loops

We have constructed a numerical model for a cooling flare loop in which the complete set of single-fluid equations in a one-dimensional geometry (i.e., parallel to the magnetic field) is solved. Both evaporative and static boundary conditions for the chromosphere-corona interface have been developed. This model is used to investigate the effects of initial temperature and density, loop geometry, and boundary conditions on the form of the plasma evolution and the soft X-ray emission. The results are then compared with Skylab S-056 observations of the 1973 August 9 flare. For this comparison, and under the present assumptions, we conclude that even highly compact flares must have a multiloop structure similar to large flares, and that both radiative and conductive cooling are necessary to explain the observations. The data appear to be consistent with the predicted emission from a combination of evaporative cooling loops.

Antiochos, S. K.↗

Solar heat transport fluid

The development and delivery of noncorrosive fluid subsystems are reported that are compatible with closed-loop solar heating or combined heating and hot water systems. They are also compatible with both metallic and non-metallic plumbing systems. The performance testing of a number of fluids is described.

Source record↗

Non-Toxic, Low-Freezing, Drop-In Replacement Heat Transfer Fluids

A non-toxic, non-flammable, low-freezing heat transfer fluid is being developed for drop-in replacement within current and future heat transfer loops currently using water or alcohol-based coolants. Numerous water-soluble compounds were down-selected and screened for toxicological, physical, chemical, compatibility, thermodynamic, and heat transfer properties. Two fluids were developed, one with a freezing point near 0 C, and one with a suppressed freezing point. Both fluids contain an additive package to improve material compatibility and microbial resistance. The optimized sub-zero solution had a freezing point of 30 C, and a freezing volume expansion of 10-percent of water. The toxicity of the solutions was experimentally determined as LD(50) greater than 5g/kg. The solutions were found to produce minimal corrosion with materials identified by NASA as potentially existing in secondary cooling loops. Thermal/hydrodynamic performance exceeded that of glycol-based fluids with comparable freezing points for temperatures Tf greater than 20 C. The additive package was demonstrated as a buffering agent to compensate for CO2 absorption, and to prevent microbial growth. The optimized solutions were determined to have physically/chemically stable shelf lives for freeze/thaw cycles and longterm test loop tests.

Cutbirth, J. Michael↗

The Role of Asymmetries in Thermal Nonequilibrium

Thermal nonequilibrium (TNE) is a fascinating situation that occurs in coronal magnetic flux tubes (loops) for which no solution to the steady-state fluid equations exists. The plasma is constantly evolving even though the heating that produces the hot temperatures does not. This is a promising explanation for isolated phenomena such as prominences, coronal rain, and long-period pulsating loops, but it may also have much broader relevance. As known for some time, TNE requires that the heating be both (quasi-)steady and concentrated at low coronal altitudes. Recent studies indicate that asymmetries are also important, with large enough asymmetries in the heating and/or cross-sectional area resulting in steady flow rather than TNE. Using reasonable approximations, we have derived two formulae for quantifying the conditions necessary for TNE. As a rough rule of thumb, the ratio of apex to footpoint heating rates must be less than about 0.1, and asymmetries must be less than about a factor of 3. The precise values are case-dependent. We have tested our formulae with 1D hydrodynamic loop simulations and find a very acceptable agreement. These results are important for developing physical insight about TNE and assessing how widespread it may be on the Sun.

Klimchuk, James A.↗

Influence of Coronal Abundance Variations

The Multispecies loop modeling project addresses the modeling of TRACE and SOHO observations as a plasma rather than a single fluid. In the single-fluid approximation the effects of heavy species are considered in an averaged sense. Further, loop abundances are usually taken to be uniform throughout the loop, in spite of observational evidence for considerable variation in coroner abundances.

DeLuca, E. E.↗

Two Phase Technology Development Initiatives

Three promising thermal technology development initiatives, vapor compression thermal control system, electronics cooling, and electrohydrodynamics applications are outlined herein. These technologies will provide thermal engineers with additional tools to meet the thermal challenges presented by increased power densities and reduced architectural options that will be available in future spacecraft. Goddard Space Flight Center and the University of Maryland are fabricating and testing a 'proto- flight' vapor compression based thermal control system for the Ultra Long Duration Balloon (ULDB) Program. The vapor compression system will be capable of transporting approximately 400 W of heat while providing a temperature lift of 60C. The system is constructed of 'commercial off-the-shelf' hardware that is modified to meet the unique environmental requirements of the ULDB. A demonstration flight is planned for 1999 or early 2000. Goddard Space Flight Center has embarked upon a multi-discipline effort to address a number of design issues regarding spacecraft electronics. The program addressed the high priority design issues concerning the total mass of standard spacecraft electronics enclosures and the impact of design changes on thermal performance. This presentation reviews the pertinent results of the Lightweight Electronics Enclosure Program. Electronics cooling is a growing challenge to thermal engineers due to increasing power densities and spacecraft architecture. The space-flight qualification program and preliminary results of thermal performance tests of copper-water heat pipes are presented. Electrohydrodynamics (EHD) is an emerging technology that uses the secondary forces that result from the application of an electric field to a flowing fluid to enhance heat transfer and manage fluid flow. A brief review of current EHD capabilities regarding heat transfer enhancement of commercial heat exchangers and capillary pumped loops is presented. Goddard Space Flight Center research efforts applying this technique to fluid management and fluid pumping are discussed.

Didion, Jeffrey R.↗

The Production of Solar Cell Grade Silicon from Bromosilanes

A continuous Flow Reactor (CFR) process based on the hydrogen reduction of the bromosilanes SiBr4 and SiHBr3 was proposed. Initial experiments carried and directed at obtaining overall yield data for bromosilane reduction in the CFR, indicated the need for increased reactor residence time and deposition substrate particle packing density to fully characterize the kinetics (rate) and thermodynamics (yield) of observed silicon production. Fluidized bed experiments were therefore initiated to overcome these experimental difficulties, which showed both thermal decomposition and hydrogen reduction of SiHBr3 in a fluid bed reactor to present attractive closed-loop processes for producing solar cell grade polycrystalline silicon. No process selection could be made however due to the fact that preliminary optimization of 2 of 3 process stages in each case during the course of the experimental program showed comparable attainment of cost element objectives.

Schumacher, J. C.↗

The SCSE Organic Rankine engine

The engine is the heart of a Power Conversion Subsystem (PCS) located at the focal point of a sun-tracking parabolic dish concentrator. The ORC engine employs a single-stage axial-flow turbine driving a high speed alternator to produce up to 25 kW electrical output at the focus of each dish. The organic working fluid is toluene, circulating in a closed-loop system at temperatures up to 400 C (750 F). Design parameters, system description, predicted performance and program status are described.

Boda, F. P.↗