Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluorescent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Hyperspectral Detection of the Fluorescence Shift between Chirality-Sorted Empty and Water-Filled Single-Wall Carbon Nanotube Enantiomers

Single-wall carbon nanotubes (SWCNTs) have extraordinary electronic and optical properties that depend strongly on their exact chiral structure and their interaction with their inner and outer environment. The fluorescence (PL) of semiconducting SWCNTs, for instance, will shift depending on the molecules with which the SWCNT’s hollow core is filled. These interaction-induced shifts are challenging to resolve on the ensemble level in samples containing a mixture of different filling contents due to the relatively large inhomogeneous line width of the ensemble SWCNT PL compared to the size of these shifts. To circumvent this inhomogeneous broadening, single-tube spectroscopy and hyperspectral imaging are often applied, which until now required time-consuming statistical studies. Here, we present hyperspectral PL microscopy combined with automated SWCNT segmenting based on either principal component analysis or a convolutional neural network, capable of both spatially and spectrally resolving the PL along the length of many individual SWCNTs at the same time and automatically fitting peak positions and line widths of individual SWCNTs. The methodology is demonstrated by accurately determining the emission shifts and line widths of thousands of left- and right-handed empty and water-filled SWCNTs coated with a chiral surfactant, resulting in four statistical distributions which cannot be resolved in ensemble spectroscopy of unsorted samples. The results demonstrate a robust method to quickly probe ensemble properties with single-enantiomer spectral resolution. Moreover, it promises to be an absolute quantitative method to characterize the relative abundances of SWCNTs with different handedness or filling content in macroscopic samples, simply by counting individual species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diurnal and Seasonal Dynamics of Solar-Induced Chlorophyll Fluorescence, Vegetation Indices, and Gross Primary Productivity in the Boreal Forest

Remote sensing of solar-induced chlorophyll fluorescence (SIF) provides a powerful proxy for gross primary productivity (GPP). It is particularly promising in boreal ecosystems where seasonal downregulation of photosynthesis occurs without significant changes in canopy structure or chlorophyll content. The use of SIF as a proxy for GPP is complicated by inherent non-linearities due to both physical (illumination effects) and ecophysiological (light use efficiencies) controls at fine spatial (tower/leaf) and temporal (half-hourly) scales. Here, to study the SIF-GPP relationship, we investigated the diurnal and seasonal dynamics of continuous tower-based measurements of SIF, GPP, and common vegetation indices at the Southern Old Black Spruce Site (SOBS) in Saskatchewan, CA over the course of two years. We find that SIF outperforms other vegetation indices as a proxy for GPP at all temporal scales but shows a non-linear relationship with GPP at a half-hourly resolution. At small temporal scales, SIF and GPP are predominantly driven by light and non-linearity between SIF and GPP is due to the light saturation of GPP. Averaged over daily and monthly scales, the relationship between SIF and GPP is linear due to a reduction in the observed PAR range. Seasonal changes in the light responses of SIF and GPP are driven by changes in light use efficiency which co-vary with changes in temperature, while illumination and canopy structure partially linearize the SIF-GPP relationship. Additionally, we find that the SIF-GPP relationship has a seasonal dependency. Our results help clarify the utility of SIF for estimating carbon assimilation in boreal forests.

59 BASIC BIOLOGICAL SCIENCES↗

Quantifying Seasonal and Diurnal Cycles of Solar‐Induced Fluorescence With a Novel Hyperspectral Imager

Abstract Solar‐induced fluorescence (SIF) is a proxy of ecosystem photosynthesis that often scales linearly with gross primary productivity (GPP) at the canopy scale. However, the mechanistic relationship between GPP and SIF is still uncertain, especially at smaller temporal and spatial scales. We deployed a ultra‐hyperspectral imager over two grassland sites in California throughout a soil moisture dry down. The imager has high spatial resolution that limits mixed pixels, enabling differentiation between plants and leaves within one scene. We find that imager SIF correlates well with diurnal changes in leaf‐level physiology and gross primary productivity under well‐watered conditions. These relationships deteriorate throughout the dry down event. Our results demonstrate an advancement in SIF imaging with new possibilities in remotely sensing plant canopies from the leaf to the ecosystem. These data can be used to resolve outstanding questions regarding SIF's meaning and usefulness in terrestrial ecosystem monitoring.

60 APPLIED LIFE SCIENCES↗

A database of thermally activated delayed fluorescent molecules auto-generated from scientific literature with ChemDataExtractor

A database of thermally activated delayed fluorescent (TADF) molecules was automatically generated from the scientific literature. It consists of 25,482 data records with an overall precision of 82%. Among these, 5,349 records have chemical names in the form of SMILES strings which are represented with 91% accuracy; these are grouped in a subsidiary database. Each data record contains one of the following four properties: maximum emission wavelength (λ EM ), photoluminescence quantum yield (PLQY), singlet-triplet energy splitting (ΔE ST ), and delayed lifetime (τ D ). The databases were created through text mining using ChemDataExtractor, a chemistry-aware natural-language-processing toolkit, which has been adapted for TADF research. The text-mined corpus consisted of 2,733 papers from the Royal Society of Chemistry and Elsevier. To the best of our knowledge, these databases are the first databases that have been auto-generated for TADF molecules from existing publications. The databases have been publicly released for experimental and computational applications in the TADF research field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diffusion of Hydrophilic to Hydrophobic Forms of Nile Red in Aqueous C 12 EO 10 Gels by Variable Area Fluorescence Correlation Spectroscopy

In this work, solute diffusion within lyotropic liquid crystal gels prepared from a series of water and decaethylene glycol monododecyl ether (C 12 EO 10 ) mixtures was explored by variable area fluorescence correlation spectroscopy. Aqueous C 12 EO 10 gels were prepared in concentrations ranging from 55:45 to 70:30 wt% of surfactant and water. Small angle X-ray scattering revealed that these gels comprise hexagonal mesophases of cylindrical micelles. Micelle spacing was found to decrease with increasing C 12 EO 10 concentration. Three different Nile red (NR) dyes were employed as model solutes and were separately doped into the gels at nanomolar levels. These include a hydrophilic form of NR incorporating an anionic sulfonate group (NRSO 3 - ), a hydrophobic form incorporating a fourteen-carbon alkane tail (NRC 14 ), and commercial NR as an intermediate case. FCS data acquired from the gels revealed that NRSO 3 - diffused primarily in 3D. Its diffusion coefficient exhibited a monotonic decrease with increasing gel concentration and micelle packing density, consistent with confinement of its motions as a result of its exclusion from the micelle cores. NRC 14 exhibited the smallest diffusion coefficient, most likely due to its larger size and enhanced interactions with the micelle cores. NR yielded an intermediate diffusion coefficient and the most anomalous behavior of the three dyes, attributable to its facile partitioning between core and corona regions, and greater participation by 1D diffusion. The results of these studies afford an improved understanding of molecular mass transport through soft-matter nanomaterials like those being developed for use in drug delivery and membrane based chemical separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser-induced fluorescence measurements of ion fluctuations in electron and ion presheaths

Electrostatic flow-driven instabilities have been predicted in the presheath region of low-temperature plasmas for both ion and electron rich sheaths. The ion-acoustic fluctuations that arise from these instabilities can influence transport through an enhanced collision rate. In this work, ion fluctuation spectra were measured using laser-induced fluorescence (LIF) in the presheath region for both sheath polarities. Furthermore, the non-invasive nature of LIF compared to that of probes is particularly valuable for these measurements because the sheath and presheath around a probe may generate their own flow-driven instabilities, which obscure the measurement. Measurements were made using a recently implemented field programmable gate array-based system able to measure ion fluctuation spectra up to 1 MHz using a two-point correlation function technique. Narrow bandwidth ion fluctuations were observed near 0:46 f pi (460 kHz) for both sheath polarities, where f pi is the ion plasma frequency. The observed fluctuations were significantly stronger in the electron sheath case and were observed over a larger volume of plasma. Fluctuations were measured in the ion sheath case at locations far enough from the sheath that linear theory predicts stability, suggesting that ion-acoustic instabilities generated in the relatively small unstable region near the boundary reflect from the sheath and perturb a much larger volume of the plasma. This is expected to affect probes with both ion and electron rich sheaths, meaning any dc biased probe may effectively act as an ion-acoustic wave antenna. These measurements are consistent with the recent theory and particle-in-cell results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact, portable, laser induced fluorescence diagnostic for laboratory plasma sources

As diagnostic groups are increasingly called upon to participate in experimental campaigns at remote facilities, there is a need to develop portable versions of plasma diagnostic systems. One such diagnostic is laser induced fluorescence (LIF). Here, we describe a portable LIF apparatus that eliminates the need for an optical table, beam splitters, and an optical chopper. All of the light exiting the laser system is coupled through optical fibers to the experiment and housekeeping diagnostics. Here, the collected light is coupled through an optical fiber as well. A key feature is modulation of the tapered amplifier current instead of physical modulation of the laser output. Using this portable LIF system, measurements of ion temperature, ion flow, and relative metastable ion density are reported for two different remote experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-photon absorption laser induced fluorescence measurements of absolute neutral deuterium density, temperature, and bulk flow in Proto-MPEX

Neutral particle control is critical for fusion fueling and confinement. Neutral diagnostics for fusion-relevant plasmas are commonly restricted to line-integrated or ex situ methods. A non-perturbative, two-photon absorption laser induced fluorescence (TALIF) diagnostic is implemented on the Prototype Material Plasma Exposure eXperiment (Proto-MPEX) to probe neutral atomic deuterium in a fusion-relevant plasma at 1 cm intervals along the radius of the vacuum vessel. The diagnostic is situated ~20 m from the vacuum vessel, and a signal is collected along the laser injection axis, requiring only one line-of-sight. TALIF measurements are absolutely calibrated using xenon and krypton. Absolute atomic densities derived from xenon calibration are compared to absolute atomic densities derived from krypton calibration. In this work, preliminary measurements of absolute atomic deuterium density, temperature, and local bulk flow dependence on radial location and input power in Proto-MPEX are presented. Neutral atomic deuterium velocity distribution functions are measured throughout a one-second plasma pulse with a time resolution of 250 ms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatiotemporal measurements of striations in a glow discharge’s positive column using laser-collisional induced fluorescence

Here we have observed the behavior of striations caused by ionization waves propagating in low-pressure helium DC discharges using the non-invasive laser-collision induced fluorescence (LCIF) diagnostic. To achieve this, we developed an analytic fit of collisional radiative model (CRM) predictions to interpret the LCIF data and recover quantitative two-dimensional spatial maps of the electron density, n e , and the ratios of LCIF emission states that can be correlated with T e with the use of accurate distribution functions at localized positions within striated helium discharges at 500 mTorr, 750 mTorr, and 1 Torr. To our knowledge, these are the first spatiotemporal, laser-based, experimental measurements of n e in DC striations. The n e and 447:588 ratio distributions align closely with striation theory. Constriction of the positive column appears to occur with decreased gas pressure, as shown by the radial n e distribution. We identify a transition from a slow ionization wave to a fast ionization wave between 750 mTorr and 1 Torr. These experiments validate our analytic fit of n e , allowing the implementation of an LCIF diagnostic in helium without the need to develop a CRM.

42 ENGINEERING↗

High repetition rate mapping of the interaction between a laser plasma and magnetized background plasma via laser induced fluorescence

In this work, the laminar coupling of energy between a laser-produced plasma and a background magnetized plasma was investigated via planar laser induced fluorescence diagnostic and magnetic flux probes. Experiments performed on the Large Plasma Device at the University of California, Los Angeles, mapped out the two-dimensional spatiotemporal evolution of the laser-plasma (debris) ion velocity distribution function (VDF) to assess debris-background coupling in a sub-Alfvénic regime. The acquisition of these data necessitates high repetition rate (1 Hz) as each dataset is the accumulation of thousands of laser shots, which would not be feasible in single-shot experiments. Fully kinetic, three-dimensional particle-in-cell simulations are compared to the measured VDFs to provide a framework in which we can understand the coupling of a sub-Alfvénic plasma flow through a preformed, magnetized plasma. The simulations display the same departure from the expected gyromotion of the debris plasma as observed in the experimental data, and in conjunction with the measured magnetic field traces, have led to the direct observation of the collisionless coupling via laminar fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrafast two-photon fluorescence imaging of cerebral blood circulation in the mouse brain in vivo

Characterizing blood flow dynamics in vivo is critical to understanding the function of the vascular network under physiological and pathological conditions. Existing methods for hemodynamic imaging have insufficient spatial and temporal resolution to monitor blood flow at the cellular level in large blood vessels. By using an ultrafast line-scanning module based on free-space angular chirped enhanced delay, we achieved two-photon fluorescence imaging of cortical blood flow at 1,000 two-dimensional (2D) frames and 1,000,000 one-dimensional line scans per second in the awake mouse. This orders-of-magnitude increase in temporal resolution allowed us to measure cerebral blood flow at up to 49 mm/s and observe pulsatile blood flow at harmonics of heart rate. Directly visualizing red blood cell (RBC) flow through vessels down to >800 µm in depth, we characterized cortical layer–dependent flow velocity distributions of capillaries, obtained radial velocity profiles and kilohertz 2D velocity mapping of multifile blood flow, and performed RBC flux measurements from penetrating blood vessels.

59 BASIC BIOLOGICAL SCIENCES↗

OH density, flux and loss probability measurements in a room temperature atmospheric pressure surface discharge by microscopic laser induced fluorescence

Many applications involving atmospheric pressure plasma-substrate interactions are enabled by the large fluxes of short-lived reactive species such as OH radicals to the substrate, nonetheless, the accurate measurement of radical densities and fluxes at substrates at atmospheric pressure has received little attention to date, particularly for surface ionization waves. We report the measurement of the OH density distribution in a surface discharge on a fused silica (quartz) substrate generated by an impinging atmospheric pressure plasma jet in dry and humid helium. The OH density is measured by microscopic laser induced fluorescence with a spatial resolution of 10 µm in the direction perpendicular to the quartz substrate. The measured OH diffusive flux varied for the investigated experimental conditions by almost three orders of magnitude and had a maximum value of 1.7 × 10 15 cm -2 s -1 . The corresponding surface loss probability of OH on the quartz surface was determined to be ~0.01. The high spatial resolution was required to accurately resolve the near surface gradient of OH radicals.

plasma-surface interactions↗

Variable energy X-ray fluorescence source

Here we detail the design of a variable energy, x-ray fluorescence source using a low activity (1.8×10 6 dpm) 99 Tc β source that irradiates thin foils. By rotating the source among foils of Ti, Zn, Nb, Ag, and Au, the device produces x rays between 4 and 70 keV at a rate near 1 Hz. When the source is placed in a storage position, the external radiation is non-detectable. The design of the shielding and rotation mechanism permits use in vacuum and at liquid nitrogen temperature. The design is intended for the study of the low energy response to radiation impinging upon Ge detector surfaces. The source will be useful for understanding the detector response in large-scale Ge arrays such as MAJORANA and LEGEND.

47 OTHER INSTRUMENTATION↗

A physiological signal derived from sun-induced chlorophyll fluorescence quantifies crop physiological response to environmental stresses in the U.S. Corn Belt

Sun-induced chlorophyll fluorescence (SIF) measurements have shown unique potential for quantifying plant physiological stress. However, recent investigations found canopy structure and radiation largely control SIF, and physiological relevance of SIF remains yet to be fully understood. This study aims to evaluate whether the SIF-derived physiological signal improves quantification of crop responses to environmental stresses, by analyzing data at three different spatial scales within the U.S. Corn Belt, i.e. experiment plot, field, and regional scales, where ground-based portable, stationary and space-borne hyperspectral sensing systems are used, respectively. We found that, when controlling for variations in incoming radiation and canopy structure, crop SIF signals can be decomposed into non-physiological (i.e. canopy structure and radiation, 60% ~ 82%) and physiological information (i.e. physiological SIF yield, Φ F , 17% ~ 31%), which confirms the contribution of physiological variation to SIF. We further evaluated whether Φ F indicated plant responses under high-temperature and high vapor pressure deficit (VPD) stresses. The plot-scale data showed that Φ F responded to the proxy for physiological stress (partial correlation coefficient, r p = 0.40, p < 0.001) while non-physiological signals of SIF did not respond ( p > 0.1). The field-scale Φ F data showed water deficit stress from the comparison between irrigated and rainfed fields, and Φ F was positively correlated with canopy-scale stomatal conductance, a reliable indicator of plant physiological condition (correlation coefficient r = 0.60 and 0.56 for an irrigated and rainfed sites, respectively). The regional-scale data showed Φ F was more strongly correlated spatially with air temperature and VPD ( r = 0.23 and 0.39) than SIF ( r = 0.11 and 0.34) for the U.S. Corn Belt. The lines of evidence suggested that Φ F reflects crop physiological responses to environmental stresses with greater sensitivity to stress factors than SIF, and the stress quantification capability of Φ F is spatially scalable. Utilizing Φ F for physiological investigations will contribute to improve our understanding of vegetation responses to high-temperature and high-VPD stresses.

54 ENVIRONMENTAL SCIENCES↗

The HIGH CHLOROPHYLL FLUORESCENCE 244 homolog CrHCF244 is required for psbA (D1) translation in Chlamydomonas reinhardtii

Translation of psbA, the chloroplast gene that encodes the D1 subunit of PSII, is important for both PSII biogenesis and repair. The translation of psbA transcripts in the chloroplast is under the control of nuclear gene products. Using a forward genetic screen and whole-genome sequencing of the alga Chlamydomonas reinhardtii , we found a mutant defective in PSII activity and mapped the causative gene to be the homolog of Arabidopsis HIGH CHLOROPHYLL FLUORESCENCE 244 (HCF244) , namely CrHCF244 . We then demonstrated that CrHCF244 is required for psbA translation in the alga, consistent with the function of HCF244 in Arabidopsis, and found that AtHCF244 also partially complemented the algal mutant. These results experimentally support the functional conservation of the homologs in green algae and land plants. Intriguingly, the CrHCF244 mutant also exhibited a relatively high rate of suppressor mutants, pointing to the presence of alternative factor(s)/pathway(s) for D1 translational control. The establishment of CrHCF244 as a psbA translation factor in C. reinhardti i shows the similarities in psbA translation regulation in algae and plants. The future identification of the alternative factor(s) in this alga will provide insights on psbA translation in plants.

Arabidopsis↗

A reliable workflow for improving nanoscale X-ray fluorescence tomographic analysis on nanoparticle-treated HeLa cells

Abstract Scanning X-ray fluorescence (XRF) tomography provides powerful characterization capabilities in evaluating elemental distribution and differentiating their inter- and intra-cellular interactions in a three-dimensional (3D) space. Scanning XRF tomography encounters practical challenges from the sample itself, where the range of rotation angles is limited by geometric constraints, involving sample substrates or nearby features either blocking or converging into the field of view. This study aims to develop a reliable and efficient workflow that can (1) expand the experimental window for nanoscale tomographic analysis of local areas of interest within a laterally extended specimen, and (2) bridge 3D analysis at micrometer and nanoscales on the same specimen. We demonstrate the workflow using a specimen of HeLa cells exposed to iron oxide core and titanium dioxide shell (Fe3O4/TiO2) nanocomposites. The workflow utilizes iterative and multiscale XRF data collection with intermediate sample processing by focused ion beam (FIB) sample preparation between measurements at different length scales. Initial assessment combined with precise sample manipulation via FIB allows direct removal of sample regions that are obstacles to both incident X-ray beam and outgoing XRF signals, which considerably improves the subsequent nanoscale tomography analysis. This multiscale analysis workflow has advanced bio-nanotechnology studies by providing deep insights into the interaction between nanocomposites and single cells at a subcellular level as well as statistical assessments from measuring a population of cells.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Geminate exciton fusion fluorescence as a probe of triplet exciton transport after singlet fission

The geminate annihilation of two triplet excitons created by singlet exciton fission is affected by the dimensionality of transport as determined by typically anisotropic triplet exciton mobilities in organic molecular crystals. We analyze this process using a random-walk model where the time dynamics of the geminate annihilation probability is determined by the average exciton hopping times along the crystallographic directions. Here, the model is then applied to the geminate fluorescence dynamics in rubrene, where the main channel for triplet-triplet annihilation is via triplet fusion and subsequent photon emission, and we identify the transitions between transport in one, two, and three dimensions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ROI-Finder : machine learning to guide region-of-interest scanning for X-ray fluorescence microscopy

The microscopy research at the Bionanoprobe (currently at beamline 9-ID and later 2-ID after APS-U) of Argonne National Laboratory focuses on applying synchrotron X-ray fluorescence (XRF) techniques to obtain trace elemental mappings of cryogenic biological samples to gain insights about their role in critical biological activities. The elemental mappings and the morphological aspects of the biological samples, in this instance, the bacterium Escherichia coli ( E. Coli ), also serve as label-free biological fingerprints to identify E. coli cells that have been treated differently. The key limitations of achieving good identification performance are the extraction of cells from raw XRF measurements via binary conversion, definition of features, noise floor and proportion of cells treated differently in the measurement. Automating cell extraction from raw XRF measurements across different types of chemical treatment and the implementation of machine-learning models to distinguish cells from the background and their differing treatments are described. Principal components are calculated from domain knowledge specific features and clustered to distinguish healthy and poisoned cells from the background without manual annotation. The cells are ranked via fuzzy clustering to recommend regions of interest for automated experimentation. The effects of dwell time and the amount of data required on the usability of the software are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗