Multi-Tone Millimeter-Wave Frequency Synthesizer for Atmospheric Propagation Studies

This paper presents the design and test results of a multi-tone millimeter-wave frequency synthesizer, based on a solid-state frequency comb generator. The intended application of the synthesizer is in a space-borne transmitter for radio wave atmospheric studies at Q-band (37-43 GHz). These studies would enable the design of robust high data rate space-to-ground satellite communication links.

Simons, Rainee N.↗

Multi-Tone Millimeter-Wave Frequency Synthesizer for Atmospheric Propagation Studies

The design and test results of a multi-tone millimeter-wave frequency synthesizer, based on a solid-state frequency comb generator is presented. The intended applications of the synthesizer is in a space-borne transmitter for radio wave atmospheric studies at Q-band (37 to 43 GHz). These studies would enable the design of robust high data rate space-to-ground satellite communication links.

Satellite Communications↗

Multi-Band Multi-Tone Tunable Millimeter-Wave Frequency Synthesizer For Satellite Beacon Transmitter

This paper presents the design and test results of a multi-band multi-tone tunable millimeter-wave frequency synthesizer, based on a solid-state frequency comb generator. The intended application of the synthesizer is in a satellite beacon transmitter for radio wave propagation studies at K-band (18 to 26.5 GHz), Q-band (37 to 42 GHz), and E-band (71 to 76 GHz). In addition, the architecture for a compact beacon transmitter, which includes the multi-tone synthesizer, polarizer, horn antenna, and power/control electronics, has been investigated for a notional space-to-ground radio wave propagation experiment payload on a small satellite. The above studies would enable the design of robust high throughput multi-Gbps data rate future space-to-ground satellite communication links.

Antenna↗

The NEID Precision Radial Velocity Spectrometer: Port Adapter Overview, Requirements, and Test Plan

The NEID spectrometer is an optical (380-930 nm), fiber-fed, precision Doppler spectrometer currently in development for the WIYN 3.5 m telescope at Kitt Peak National Observatory as part of the NN-EXPLORE partnership. Designed to achieve a radial velocity precision of < 30 cm/s, NEID will be sensitive enough to detect terrestrial-mass exoplanets around low-mass stars. Light from the target stars is focused by the telescope to a bent Cassegrain port at the edge of the primary mirror mechanical support. The specialized NEID "Port Adapter" system is mounted at this bent Cassegrain port and is responsible for delivering the incident light from the telescope to the NEID fibers. In order to provide stable, high-quality images to the science instrument, the Port Adapter houses several sub-components designed to acquire the target stars, correct for atmospheric dispersion, stabilize the light onto the science fibers, and calibrate the spectrometer by injecting known wavelength sources such as a laser frequency comb. Here we provide an overview of the overall opto-mechanical design and system requirements of the Port Adapter. We also describe the development of system error budgets and testplans to meet those requirements.

Cassegrain port↗

2023 Astrophotonics Roadmap: Pathways to Realizing Multi-Functional Integrated Astrophotonic Instruments

Photonic technologies offer numerous functionalities that can be used to realize astrophotonic instruments. The most spectacular example to date is the ESO Gravity instrument at the Very Large Telescope in Chile that combines the light-gathering power of four 8 m telescopes through a complex photonic interferometer. Fully integrated astrophotonic devices stand to offer critical advantages for instrument development, including extreme miniaturization when operating at the diffraction-limit, as well as integration, superior thermal and mechanical stabilization owing to the small footprint, and high replicability offering significant cost savings. Numerous astrophotonic technologies have been developed to address shortcomings of conventional instruments to date, including for example the development of photonic lanterns to convert from multimode inputs to single mode outputs, complex aperiodic fiber Bragg gratings to filter OH emission from the atmosphere, complex beam combiners to enable long baseline interferometry with for example, ESO Gravity, and laser frequency combs for high precision spectral calibration of spectrometers. Despite these successes, the facility implementation of photonic solutions in astronomical instrumentation is currently limited because of (1) low throughputs from coupling to fibers, coupling fibers to chips, propagation and bend losses, device losses, etc, (2) difficulties with scaling to large channel count devices needed for large bandwidths and high resolutions, and (3) efficient integration of photonics with detectors, to name a few. In this roadmap, we identify 24 key areas that need further development. We outline the challenges and advances needed across those areas covering design tools, simulation capabilities, fabrication processes, the need for entirely new components, integration and hybridization and the characterization of devices. To realize these advances the astrophotonics community will have to work cooperatively with industrial partners who have more advanced manufacturing capabilities. With the advances described herein, multi-functional integrated instruments will be realized leading to novel observing capabilities for both ground and space based platforms, enabling new scientific studies and discoveries.

astrophotonics↗

A Photonic Clockwork for Deployed Timing and Radar

We present an environmentally robust photonic RF/microwave clockwork with low size, weight, and power (SWaP) for next-generation, field-deployable timing and radar applications. Compared to microwave references, optical local oscillators offer superior fractional frequency stability and phase-noise performance. When transferred with high fidelity into the RF/microwave domain, this “optical advantage” promises unparalleled performance across both private-industry and government (e.g., defense and space-agency) applications including very-long-baseline interferometry (VLBI), alternative positioning, navigation, and timing (PNT), multi-static synthetic aperture radar (MSAR), and geodetic sensing. However, this potential has yet to be fully realized outside the metrology lab primarily due to the high-SWaP and excessive environmental susceptibility of both the optical reference itself as well as the optical frequency comb (OFC) required to transfer the optical stability into the RF/microwave domain. Here, we present two demonstrations of a low-SWaP, environmentally robust photonic clockwork used to make a high-fidelity optical-microwave link with the stability and phase-noise performance relevant to the applications described above. Additionally, operational-testing results of the OFC subsystem under application-relevant environmental conditions will be presented to show pathway to field deployment of this critical subsystem.

Guangning Yang↗

2012 ELECTRONIC SPECTROSCOPY & DYNAMICS GORDON RESEARCH CONFERENCE, JULY 22-27, 2012

Topics covered in this GRC include high-resolution spectroscopy, coherent electronic energy transport in biology, excited state theory and dynamics, excitonics, electronic spectroscopy of cold and ultracold molecules, and the spectroscopy of nanostructures. Several sessions will highlight innovative techniques such as time-resolved x-ray spectroscopy, frequency combs, and liquid microjet photoelectron spectroscopy that have forged stimulating new connections between gas-phase and condensed-phase work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved isotope-shift-based bounds on bosons beyond the Standard Model through measurements of the $^2$D$_{3/2} - ^2$D$_{5/2}$ interval in Ca$^+$

We perform high-resolution spectroscopy of the $3$d$~^2$D$_{3/2} - 3$d$~^2$D$_{5/2}$ interval in all stable even isotopes of $^A$Ca$^+$ (A = 40, 42, 44, 46 and 48) with an accuracy of $\sim$ 20 Hz using direct frequency-comb Raman spectroscopy. Combining these data with isotope shift measurements of the 4s$~^2$S$_{1/2} \leftrightarrow 3$d$~^2$D$_{5/2}$ transition, we carry out a King plot analysis with unprecedented sensitivity to coupling between electrons and neutrons by bosons beyond the Standard Model. Furthermore, we estimate the sensitivity to such bosons from equivalent spectroscopy in Ba$^+$ and Yb$^+$. Finally, the data yield isotope shifts of the 4s$~^2$S$_{1/2} \leftrightarrow 3$d$~^2$D$_{3/2}$ transition at 10 part-per-billion through combination with recent data of Knollmann et al (2019).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of the Hartmann–Tran profile to precise experimental data sets of 12 C 2 H 2

Self- and nitrogen-broadened line shape data for the P e (11) line of the ν₁ + ν₃ band of acetylene, recorded using a frequency comb-stabilized laser spectrometer, have been analyzed using the Hartmann–Tran profile (HTP) line shape model in a multispectrum fitting. In total, the data included measurements recorded at temperatures between 125 K and 296 K and at pressures between 4 and 760 Torr. New, sub-Doppler, frequency comb-referenced measurements of the positions of multiple underlying hot band lines have also been made. These underlying lines significantly affect the P e (11) line profile at temperatures above 240 K and poorly known frequencies previously introduced errors into the line shape analyses. Thus, the behavior of the HTP model was compared to the quadratic speed dependent Voigt profile (QSDVP) expressed in the frequency and time domains. A parameter uncertainty analysis was carried out using a Monte Carlo method based on the estimated pressure, transmittance and frequency measurement errors. From the analyses, the P e (11) line strength was estimated to be 1.2014(50) × 10 -20 in cm.molecules⁻¹ units at 296 K with the standard deviation in parenthesis. For analyzing these data, we found that a reduced form of the HTP, equivalent to the QSDVP, was most appropriate because the additional parameters included in the full HTP were not well determined. As a supplement to this work, expressions for analytic derivatives and a lineshape fitting code written in Matlab for the HTP are available.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Re-evaluation of ortho-para- dependence of self pressure-broadening in the ν 1 + ν 3 band of acetylene

Optical frequency comb-referenced measurements of self pressure-broadened line profiles of the R(8) to R(13) lines in the ν 1 + ν 3 combination band of acetylene near 1.52 µ m are reported. The analysis of the data found no evidence for a previously reported systematic alternation in self pressure-broadened line widths with the nuclear spin state of the molecule. This work brought out the need for the use of an accurate line profile model and careful accounting for weak background absorptions due to hot band and lower abundance isotopomer lines. The data were adequately fit using the quadratic speed-dependent Voigt profile model, neglecting the small speed-dependent shift. Parameters describing the most probable and speed-dependent pressure-broadening, most probable shift, and the line strength were determined for each line. Detailed modeling of the results of Iwakuni et al. showed that their neglect of collisional narrowing due to the speed-dependent broadening term combined with the strongly absorbing data recorded and analyzed in transmission mode were the reasons for their results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Frequency-domain modeling of floating wind arrays with shared mooring lines

A frequency-domain model for floating wind turbine dynamics has been extended to model floating wind farms with couplings from shared mooring systems. The model, called RAFT, could previously calculate the mean offsets and wave-induced response spectra for single floating wind turbines. Now, the model supports multiple floating wind turbines, each with their own properties and responses, along with mooring lines that run directly between floating wind turbines in the array, meaning that shared mooring lines or fully suspended dynamic power cables can be included. This capability is achieved by setting up an array-level solution of the system mean offsets and assembling the full system matrices for solving the dynamic response. The quasi-static mooring model MoorPy is used to linearize the mooring system properties. To compute the floating wind turbine relative motions, phase offsets are applied to each turbine's response as a function of wave frequency based on the wavelength and relative positions in the array. These differential motions are then applied to mooring system tension Jacobians to compute the tension loads in the shared mooring lines. Overall, the capability provides a frequency-domain analog to the modeling capabilities of the floating support structure in FAST.Farm. Mean offsets and power spectral density plots of responses are compared between RAFT and FAST.Farm to verify the implementation. The results indicate good agreement within the expectations of a frequency-domain modeling approach and suggest correct implementation of the shared mooring aspects. Additionally, a unique comb-like frequency response in the shared mooring line tensions has been observed. This phenomenon has a clear physical basis and may be an important design consideration for future shared mooring systems.

17 WIND ENERGY↗

Frequency measurements and self-broadening of sub-Doppler transitions in the v1 + v3 band of C 2 H 2

Here, frequency comb-referenced measurements of sub-Doppler laser saturation dip absorption lines in the v1 + v3 band of acetylene near 1:5 μm are reported. These measurements include transitions involving higher rotational levels than previously frequency measured in this band. The accuracy of the measured frequencies is typically better than 10 kHz. Measurements of the observed sub-Doppler line widths as a function of pressure showed that the self pressure-broadening coefficients are about 3.5 times larger than those derived from conventional pressure broadening of unsaturated Doppler-limited spectra. This is attributed to the contribution of velocity-changing collisions to the total dephasing rate in the low pressure sub-Doppler measurements. At higher pressures, when the homogeneous broadening becomes comparable to the typical Doppler shift per elastic collision, the velocity changing collisions cease to contribute significantly to the incremental pressure broadening. Lastly, a time-dependent soft collision model is developed to illustrate the transition between low and high pressure regimes of sub-Doppler pressure-broadening.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quadrupole splittings in the near-infrared spectrum of 14 NH 3

Sub-Doppler, saturation dip, spectra of lines in the v 1 + v 3 , v 1 + 2v 4 and v 3 + 2v 4 bands of 14 NH 3 have been measured by frequency comb-referenced diode laser absorption spectroscopy. The observed spectral line widths are dominated by transit time broadening, and show resolved or partially-resolved hyperfine splittings that are primarily determined by the 14 N quadrupole coupling. Modeling of the observed line shapes based on the known hyperfine level structure of the ground state of the molecule shows that, in nearly all cases, the excited state level has hyperfine splittings similar to the same rotational level in the ground state. The data provide accurate frequencies for the line positions and easily separate lines overlapped in Doppler-limited spectra. The observed hyperfine splittings can be used to make and confirm rotational assignments and ground state combination differences obtained from the measured frequencies are comparable in accuracy to those obtained from conventional microwave spectroscopy. Furthermore, several of the measured transitions do not show the quadrupole hyperfine splittings expected based on their existing rotational assignments. Either the assignments are incorrect or the upper levels involved are perturbed in a way that affects the nuclear hyperfine structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low-index-metamaterial for gain enhancement of planar terahertz antenna

We theoretically present a high gain planar antenna at terahertz (THz) frequencies by combing a conventional log-periodic antenna (LPA) with a low-index-metamaterial (LIM, |n| < 1). The LIM is realized by properly designing a fishnet metamaterial using full-wave finite-element simulation. Owing to the impedance matching, the LIM can be placed seamlessly on the substrate of the LPA without noticeable reflection. The effectiveness of using LIM for antenna gain enhancement is confirmed by comparing the antenna performance with and without LIM, where significantly improved half-power beam-width (3-dB beam-width) and more than 4 dB gain enhancement are seen within a certain frequency range. The presented LIM-enhanced planar THz antenna is compact, flat, low profile, and high gain, which has extensive applications in THz systems, including communications, radar, and spectroscopy.

36 MATERIALS SCIENCE↗

Burst-mode dual-comb spectroscopy

We introduce a new modality of dual-comb spectroscopy that enables a simplified and powerful new approach for time-resolved measurements with increased acquisition rates. This "burst mode" form of dual-comb spectroscopy (BM-DCS) relies on the multiplexing of each probe pulse into a short train of pulses. With this approach we demonstrate a time-resolved series of absorption-based spectroscopic measurements of a laser-induced plasma using only a single laser ablation shot and identify 22 Nd lines not previously reported in the literature. The transmission spectra spanned 3.1 THz and were acquired at an effective acquisition rate of 25 kHz with 40 ms time-resolution. This simple modification to 100 MHz level dual-comb systems provides a flexible approach for studying transient and low duty-cycle events such as laser-induced plasmas, combustion, and explosive reactions.

(280.5395) Plasma Diagnostics, broadband laser spe↗

Multi-species temperature and number density analysis of a laser-produced plasma using dual-comb spectroscopy

Dual-comb spectroscopy (DCS) represents a novel method of using absorption spectroscopy as a diagnostic tool for multispecies analysis of excitation temperatures and column densities in laser-produced plasmas (LPPs). DCS was performed on a LPP generated by ablating a multielement alloy containing Nd, Gd, and Fe. Transitions from all three elements were observed in absorption spectra measured from 530.08 to 535.19 nm at seven time-delays from 31 to 250 μs after ablation. The spectra were fit using a nonlinear regression algorithm to determine peak areas, and excitation temperatures and column densities were determined for the three atomic species separately using Boltzmann plots. The measured excitation temperatures of Nd I and Gd I showed good agreement at all time-delays, whereas the Fe I temperature was found to be higher, and the ratios between the column densities varied with delay. The observations are understood via effects of LPP spatial averaging, elemental fractionation, and molecular formation and are compared and contextualized with previous work studying LPPs using other spectroscopic techniques. A brief discussion of the precision and accuracy of the determined excitation temperatures and column densities is also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of neutral gadolinium oscillator strengths using dual-comb absorption spectroscopy in laser-produced plasmas

The oscillator strengths of 43 transitions of neutral gadolinium from 530 to 535 nm were determined based on high-resolution absorption spectra measured by probing a laser-produced plasma (LPP) using time-resolved dual-comb spectroscopy (DCS). Absorption spectra were measured at various time delays, ranging from 33 to 252 µs after the onset of the plasma formation, over which the temperature and number density varied as the ablation plume evolved. A Boltzmann analysis was used to determine the excitation temperature and column density of Gd in the ablation plume, based on measured absorption from 20 Gd I spectral lines with known oscillator strengths. Oscillator strengths were then determined for additional dipole-allowed Gd I transitions identified in the absorption spectra, 19 of which were previously unreported. Oscillator strengths of all measured transitions were compared with literature values when available and show good agreement in most cases. Time-resolved measurement of atomic absorption in the cooling plasma provides access to a range of excitation temperatures and optical densities for the atoms in the ablation plume, allowing repeated measurements under different conditions, thereby improving confidence in the results. The high spectral bandwidth and resolution capabilities of DCS make it well-suited to measuring the dense optical spectrum of Gd, and the technique is applicable to other elements, especially lanthanides and actinides.

(280.4788) Optical Sensing, (280.5395) Plasma Diag↗

Harmonic and Subharmonic RF Injection Locking of THz Metasurface Quantum-Cascade VECSEL

Harmonic and subharmonic RF injection locking is demonstrated in a terahertz (THz) quantum-cascade vertical-external-cavity surface-emitting laser (QC-VECSEL). By tuning the RF injection frequency around integer multiples and submultiples of the cavity round-trip frequency, different harmonic and subharmonic orders can be excited in the same device. Modulation-dependent behavior of the device has been studied with recorded lasing spectral broadening and locking bandwidths in each case. In particular, harmonic injection locking results in the observation of harmonic spectra with bandwidths over 200 GHz. A semiclassical Maxwell-density matrix formalism has been applied to interpret QC-VECSEL dynamics, which aligns well with experimental observations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗