Search NASA⌕ Search

SEARCH · Search NASA

Results for “full scale testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

1- by 1-Foot Supersonic Wind Tunnel Sidewall Flowfield Compression Plate Study

A method for locally increasing the dynamic pressure in the test section of a supersonic wind tunnel is investigated from a theoretical, computational and experimental perspective, culminating in a reduced-scale, proof-of-concept test at Mach 3.44. Symmetric, variable-angle compression plates along the test section sidewalls generate oblique shockwaves to elevate the test section dynamic pressure (q). The experimental effort utilizes boundary-layer pitot rakes to sample the incoming flow near the floor, pitot and static rakes to measure the high-q core flow and numerous surface taps to map out the static pressure distribution along the floor, ceiling and sidewalls. A reliable and robust starting procedure is developed to establish supersonic flow in the test section and behind the compression plates. A characterization of the incoming floor boundary layer reveals previously documented features (such as a bulge toward the centerline) and an unexpected (and as-yet-unexplained) thickening of the boundary layer with increasing Reynolds number around total pressures of 40–60 psia. The high-q core flow is characterized for eight compression plate angles (4.0–8.0°), eight tunnel total pressures (20–139 psia) and three axial stations (24.95–27.35 inches). The peak dynamic pressure rise exceeds expectations. At conditions relevant to full-scale testing (6.0° and 139 psia), the dynamic pressure increases by a factor of 1.73, the Mach number becomes 2.85 and the total pressure drops imperceptibly. Basic distortion metrics show transverse non-uniformity of less than 5 %. Limited spatial resolution in the static rake measurements warrants additional, higher fidelity testing or computational analysis. Surface-mounted, fast-response instrumentation suggests minimal unsteadiness in the flow, less than a few percent of the mean (comparable to the sensor accuracy).

Wind tunnel testing, test techniques/methods, dyna↗

DC-10 composite vertical stabilizer ground test program

A review of the structural configuration and ground test program is presented. Particular emphasis is placed on the testing of a full-scale stub box test subcomponent and full span ground test unit. The stub box subcomponent was tested in an environmental chamber under ambient, cold/wet, and hot/wet conditions. The test program included design limit static loads, fatigue spectrum loading to approximately two service lifetimes (with and without damage), design limit damage tolerance tests, and a final residual strength test to a structural failure. The first full-scale ground test unit was tested under ambient conditions. The test unit was to have undergone static, fatigue, and damage tolerance tests but a premature structural failure occurred at design limit load during the third limit load test. A failure theory was developed which explains the similarity in types of failure and the large load discrepancy at failure between the two test articles. The theory attributes both failures to high stress concentrations at the edge of the lower rear spar access opening. A second full-scale ground test unit has been modified to incorporate the various changes resulting from the premature failure. The article has been assembled and is active in the test program.

Palmer, J. M., Jr.↗

Cumulative Measurement Errors for Dynamic Testing of Space Flight Hardware

Located at the NASA Johnson Space Center in Houston, TX, the Six-Degree-of-Freedom Dynamic Test System (SDTS) is a real-time, six degree-of-freedom, short range motion base simulator originally designed to simulate the relative dynamics of two bodies in space mating together (i.e., docking or berthing). The SDTS has the capability to test full scale docking and berthing systems utilizing a two body dynamic docking simulation for docking operations and a Space Station Remote Manipulator System (SSRMS) simulation for berthing operations. The SDTS can also be used for nonmating applications such as sensors and instruments evaluations requiring proximity or short range motion operations. The motion base is a hydraulic powered Stewart platform, capable of supporting a 3,500 lb payload with a positional accuracy of 0.03 inches. The SDTS is currently being used for the NASA Docking System testing and has been also used by other government agencies. The SDTS is also under consideration for use by commercial companies. Examples of tests include the verification of on-orbit robotic inspection systems, space vehicle assembly procedures and docking/berthing systems. The facility integrates a dynamic simulation of on-orbit spacecraft mating or de-mating using flight-like mechanical interface hardware. A force moment sensor is used for input during the contact phase, thus simulating the contact dynamics. While the verification of flight hardware presents unique challenges, one particular area of interest involves the use of external measurement systems to ensure accurate feedback of dynamic contact. The measurement systems for the test facility have two separate functions. The first is to take static measurements of facility and test hardware to determine both the static and moving frames used in the simulation and control system. The test hardware must be measured after each configuration change to determine both sets of reference frames. The second function is to take dynamic measurements during hardware motion and contact. While performing dynamic testing of an active docking system, researchers found that the data from the motion platform, test hardware and two external measurement systems exhibited frame offsets and rotational errors. While the errors were relatively small when considering the motion scale overall, they substantially exceeded the individual accuracies for each component. After evaluating both the static and dynamic measurements, researchers found that the static measurements introduced significantly more error into the system than the dynamic measurements even though, in theory, the static measurement errors should be smaller than the dynamic. In several cases, the magnitude of the errors varied widely for the static measurements. Upon further investigation, researchers found the larger errors to be a consequence of hardware alignment issues, frame location and measurement technique whereas the smaller errors were dependent on the number of measurement points. This paper details and quantifies the individual and cumulative errors of the docking system and describes methods for reducing the overall measurement error. The overall quality of the dynamic docking tests for flight hardware verification was improved by implementing these error reductions.

Winnitoy, Susan↗

Beryllium heat shield technology in the area of thermal protection devices

For future space applications, it is important that thermal protection systems be reusable for space shuttle flights. Beryllium offers a unique combination of properties for use as a heat shield material (stiffness, lightweight, ability to absorb heat). In order to adequately test these properties, it was necessary to fabricate heat shields. The concept used was a two-section test panel 99.1 x 99.1 cm (39 x 39 inch) with each section made of two 0.051 cm (0.020 inch) thick beryllium corrugations brazed together as a mirror image, with titanium (Ti-6Al-4V) used as standoffs to support the panel structure. The work prior to fabrication included brazability of both beryllium and titanium, forming of beryllium and titanium, machining processes involving beryllium and chem-milling beryllium. Sub-scale samples were made of all details before actual fabrication of the large panel. The full scale test panel was hot-formed at 950 K, chem-milled to 0.041 + or - 0.005 cm (0.016 + or - 0.002 inches), trimmed, vacuum brazed, drilled and assembled.

Muhl, A. E.↗

Design, development, and test of Shuttle/Centaur G-prime cryogenic tankage thermal protection systems

The thermal protection systems (TPS) for the Shuttle/Centaur were designed to provide fail-safe thermal protection during prelaunch, launch ascent, and on-orbit operations as well as during potential abort, where the Shuttle and Centaur would return to earth. The TPS selected used a helium-purged polyimide foam beneath three radiation shields for the liquid-hydrogen (LH2) tank and radiation shields only for the liquid-oxygen (LO2) tank. A double-walled vacuum bulkhead separated the two tanks. The LH2 tank had one 1.9 cm-thick layer of foam on the forward bulkhead and two layers on the larger-area sidewall. Full scale tests of the flight vehicle in a simulated Shuttle cargo bay gave total prelaunch heating rates of 29.5 and 12.9 kW for the LH2 and LO2 tanks, respectively. Calorimeter tests on a representative sample of the LH2 tank sidewall TPS indicated that the measured unit heating one would rapidly decrease from the prelaunch rate of about 300 W/sq m to a desired rate less than 4 W/sq m once on-orbit.

Macneil, Peter N.↗

Wind-tunnel investigation of the heat transfer to the X-15 airplane

Paper describes the wind tunnel test program which has provided a picture of the general distribution of heat transfer coefficients over the X-15 airplane. The tunnel tests have emphasized the importance of the interactions of the flow fields of components and have shown that in some cases, where the local flow direction and total pressure can be reasonably closely inferred, use of experimental pressures to compute flow conditions yields very good predictions of heat transfer rate. There are still some regions of the airplane for which the heat transfer could not be adequately studied because of the size or construction of the model. Such local regions will not necessarily limit the operation of the airplane but will require evaluation in the full-scale tests. (author)

Feller, William V↗

Design, development and test of shuttle/Centaur G-prime cryogenic tankage thermal protection systems

The thermal protection systems for the shuttle/Centaur would have had to provide fail-safe thermal protection during prelaunch, launch ascent, and on-orbit operations as well as during potential abort. The thermal protection systems selected used a helium-purged polyimide foam beneath three rediation shields for the liquid-hydrogen tank and radiation shields only for the liquid-oxygen tank (three shields on the tank sidewall and four on the aft bulkhead). A double-walled vacuum bulkhead separated the two tanks. The liquid-hydrogen tank had one 0.75-in-thick layer of foam on the forward bulkhead and two layers on the larger area sidewall. Full scale tests of the flight vehicle in a simulated shuttle cargo bay that was purged with gaseous nitrogen gave total prelaunch heating rates of 88,500 Btu/hr and 44,000 Btu/hr for the liquid-hydrogen and -oxygen tanks, respectively. Calorimeter tests on a representative sample of the liquid-hydrogen tank sidewall thermal protection system indicated that the measured unit heating rate would rapidly decrease from the prelaunch rate of approx 100 Btu/hr/sq ft to a desired rate of less than 1.3 Btu/hr/sq ft once on orbit.

Knoll, Richard H.↗

Development and test of the Shuttle/Centaur cryogenic tankage thermal protection system

The Thermal Protection System (TPS) for the Shuttle/Centaur had to provide fail-safe thermal protection during prelaunch, launch ascent, and on-orbit operations as well as during potential abort where the Shuttle and Centaur would return to earth. The TPS selected used a helium-purged polyimide foam beneath three radiation shields for the liquid hydrogen (LH2) tank and radiation shields only for the liquid oxygen (LO2) tank (three shields on the tank sidewall and four on the aft bulkhead). An evacuated common intermediate bulkhead separated the two tanks. The LH2 tank had one 1.9-cm thick layer of foam on the forward bulkhead and two layers on the larger area side-wall. Full scale tests of the flight vehicle in a simulated Shuttle cargo bay, that was purged with gaseous nitrogen, gave total prelaunch heating rates of 25.9 kW and 12.9 kW for LH2 and LO2 tanks, respectively. Calorimeter tests on a representative LH2 tank sidewall TPS sample indicated that the measured unit heating rate would rapidly decrease from the prelaunch rate of 300 W/sq m to a desired rate of less than 4 W/sq m once on-orbit.

Knoll, R. H.↗

Surface tension propellant control for Viking 75 Orbiter

The paper describes the selection, development and qualification of the surface tension system and includes results of low-g drop tower tests of scale models, 1-g simulation tests of low-g large ullage settling and liquid withdrawal, structural qualification tests, and propellant surface tension/contact angle studies. Subscale testing and analyses were used to evaluate the ability of the system to maintain or recover the desired propellant orientation following possible disturbances during the Viking mission. This effort included drop tower tests to demonstrate that valid wick paths exist for moving any displaced propellant back over the tank outlet. Variations in surface tension resulting from aging, temperature, and lubricant contamination were studied and the effects of surface finish, referee fluid exposure, aging, and lubricant contamination on contact angle were assessed. Results of movies of typical subscale drop tower tests and full scale slosh tests are discussed.

Dowdy, M. W.↗

Investigation of a Helicopter Individual Blade Control (IBC) System in Two Full-Scale Wind Tunnel Tests: Volume II—Tabulated Data

This volume presents the tabulated data acquired during the testing of an individual blade control (IBC) system for a full-scale BO-105 helicopter rotor in the NASA Ames 40- by 80-Foot Wind Tunnel. The data are divided into appendices according to the data type. Table 6 in Volume I presents a summary of the data acquired during the 1993 and 1994 IBC wind tunnel tests. The data have been tabulated according to test year, run number, and point number (e.g., 1993 IBC Test, Run 20, pt. 3). The 1993 and 1994 IBC tests were each started with a run number of 1. A new run number was assigned each time the wind tunnel and rotor were restarted, even if no data were acquired during the previous run. For this reason, some run numbers appear to be missing, yet all of the IBC data is included in the tabulated data, with one notable exception. The Fourier series data presented in Appendices H, L, and N are provided only for the data points identified with the ”•“ symbol in the last column of Table 6 in Volume I. This was done to keep the physical size of the data tables reasonable. The table below shows which data were included in these appendices; the data encompass the majority of the IBC inputs tested in the wind tunnel. Data for the points not included in Appendices H, L, and N have been retained in the BO-105 IBC database and are electronically available from NASA Ames Research Center.

Investigation↗

Thermal/Dynamic Characterization Test of the Solar Array Panel for Hubble Space Telescope

The Hubble Space Telescope has experienced a problem maintaining pointing accuracy during emergence of the spacecraft from the Earth's shadow. The problem has been attributed to the rapid thermal gradient that develops when the heat from the Sun strikes the cold solar arrays. The thermal gradient causes the solar arrays to deflect or bend and this motion is sufficient to disturb the pointing control system. In order to alleviate this problem, a new design for the solar arrays has been fabricated. These new solar arrays will replace the current solar arrays during a future Hubble servicing mission. The new solar arrays have been designed so that the effective net motion of the center of mass of each panel is essentially zero. Although the solar array thermal deflection problem has been studied extensively over a period of years, a full scale test of the actual flight panels was required in order to establish confidence in the analyses. This test was conducted in the JPL Solar Simulation Facility in April, 1999. This presentation will discuss the objectives and methods of the test and present some typical test data.

Jenkins, Kathleen↗

Lessons Learned from Recent Space Flight Assessments

This paper highlights four space flight assessments, each with an important lesson. The first assessment points to the challenge of material substitution for weight saving. Space Shuttle’s external tank stringers were changed from Al 2024 to Al 2090 without comprehensive analysis. Lack of understanding the low Short-Transverse (S-T) strength associated with Al 2090 led to widespread cracking. The second assessment addresses the failure to understand that time-dependent relationships and loading interactions of multiple disciplines can lead to non-conservative results. An aerodynamic test article of the Orion Multi-Purpose Crew Vehicle (MPCV) Launch Abort System (LAS) was analyzed for worst-case single discipline loads, showing positive structural margins. When disciplines were combined with time dependent loading, the analysis resulted in negative margins. The third assessment highlights the pitfalls of putting blind trust in historical architecture. The MPCV re-entry heat shield adopted the Apollo design approach despite fundamental differences between the two designs (e.g., the underlying substructure design, material differences, scale, and geometry). Manufacturing resulted in cracking along seams of the cured MPCV heat shield and produced lower mechanical properties of the Avcoat witness panels. Subsequently, the design was changed to a block architecture, which introduced unperceived technical, cost, and schedule risk. The fourth assessment shows how the lack of a comprehensive investigation of design modifications and inappropriate Finite Element Analyses (FEA) can lead to trouble. A mass reduction campaign eliminated highly critical internal struts on the ISS Node-1 pressurized module based on inadequate and uncorrelated FEA. High strains were noted and ignored as a modeling aberration. A system level high fidelity FEA discovered large plastic strains in the gussets of all four radial ports. These findings initiated a full-scale test campaign, new test correlated assembly-level FEA, and significant design modifications.

James P Smith↗

Status of the NERVA program.

NERVA program, reactor and nonnuclear component development, full-scale testing, engine program, facilities and materials research

NUCLEAR ROCKET↗

Design and development of pressure and repressurization purge system for reusable space shuttle multilayer insulation system

Preliminary design and analysis of purge system concepts and purge subsystem approaches are defined and evaluated. Acceptable purge subsystem approaches were combined into four predesign layouts which are presented for comparison and evaluation. Two predesigns were selected for further detailed design and evaluation for eventual selection of the best design for a full scale test configuration. An operation plan is included as an appendix for reference to shuttle-oriented operational parameters.

Source record↗

Preliminary design of a solar heat receiver for a Brayton cycle space power system

The preliminary design of a solar heat receiver for use as a heat source for an earth-orbiting 11-kWe Brayton-cycle engine is described. The result was a cavity heat receiver having the shape of a frustum of a cone. The wall of the cone is formed by 48 heat-transfer tubes, each tube containing pockets of lithium fluoride for storing heat for as much as 38 minutes of fullpower operation in the shade. Doors are provided in order to dump excess heat especially during operation in orbits with full sun exposure. The receiver material is predominantly columbium - 1-percent-zironium (Cb-1Zr) alloy. Full-scale testing of three heat-transfer tubes for more than 2000 hours and 1250 sun-shade cycles verified the design concept.

Cameron, H. M.↗

Flutter technology for space shuttle

The development of analytical and experimental techniques needed to predict space shuttle flutter boundaries and insure adequate flutter margins and anticipated problems associated with aeroelastic-model and full-scale testing to validate flutter clearance are considered. Results illustrating the best available tools for subsonic and supersonic flutter prediction are presented. Programs currently underway which will help overcome the difficult problems envisioned for the transonic wind-tunnel and flight flutter test program are also discussed.

Goetz, R. C.↗