Generation of radioisotopes for medical applications using high-repetition, high-intensity lasers

We used the PW high-repetition laser facility VEGA-3 at Centro de Láseres Pulsados in Salamanca, with the goal of studying the generation of radioisotopes using laser-driven proton beams. Various types of targets have been irradiated, including in particular several targets containing boron to generate α-particles through the hydrogen–boron fusion reaction. We have successfully identified γ-ray lines from several radioisotopes created by irradiation using laser-generated α-particles or protons including 43 Sc, 44 Sc, 48 Sc, 7 Be, 11 C and 18 F. We show that radioisotope generation can be used as a diagnostic tool to evaluate α-particle generation in laser-driven proton–boron fusion experiments. We also show the production of 11 C radioisotopes, ≈ 6 × 10 6 , and of 44 Sc radioisotopes, ≈ 5 × 10 4 per laser shot. This result can open the way to develop laser-driven radiation sources of radioisotopes for medical applications.

gamma ray spectroscopy↗

Real-time nuclear activation detectors for measuring neutron angular distributions at the National Ignition Facility (invited)

The Real Time Nuclear Activation Detector (RTNAD) array at NIF measures the distribution of 14 MeV neutrons emitted by deuterium-tritium (DT) fueled inertial confinement fusion implosions. The uniformity of the neutron distribution is an important indication of implosion symmetry and DT shell integrity. The array consists of 48 LaBr 3 (Ce) crystal gamma-ray spectrometers mounted outside the NIF target chamber, which continuously monitor the slow decay of the 909 keV gamma-ray line from activated 89 Zr located in Zr cups surrounding each crystal. The measured decay rate dramatically increases during a DT implosion in proportion to the number of 14 MeV neutrons striking each Zr cup. The neutrons produce activated 89 Zr through an (n, 2n) reaction on 90 Zr, which is insensitive to low energy neutrons. The neutron flux along the detector line-of-sight at shot time is determined by extrapolating the fitted 909 keV decay curve back to shot time. Automatic analysis algorithms were developed to handle the non-stop data stream. The large number of detectors and the high statistical accuracy of the array enable the spherical harmonic modes of the neutron angular distribution to be measured up to L ≤ 4 to provide a better understanding of implosion dynamics. In addition, these data combined with measurements of the down-scattered neutrons can be used to derive fuel areal density distributions. This paper will describe the RTNAD hardware and analysis procedures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A scintillator attenuation spectrometer for intense gamma-rays

A new type of compact high-resolution high-sensitivity gamma-ray spectrometer for short-pulse intense gamma-rays (250 keV to 50 MeV) has been developed by combining the principles of scintillators and attenuation spectrometers. The first prototype of this scintillator attenuation spectrometer (SAS) was tested successfully in Trident laser experiments at LANL. Later versions have been used extensively in the Texas Petawatt laser experiments in Austin, TX, and more recently in OMEGA-EP laser experiments at LLE, Rochester, NY. The SAS is particularly useful for high-repetition-rate laser applications. Furthermore, we give a concise description of the design principles, capabilities, and sample preliminary results of the SAS.

47 OTHER INSTRUMENTATION↗

A perspective on the device physics of lead halide perovskite semiconducting detector for gamma and x-ray sensing

Metal-halide perovskites are emerging materials for radiation sensing featuring high absorption cross section, high charge mobility, and long carrier lifetime enabling superior detection efficiencies even at room temperature. Perovskite detector technologies are more complex involving different detecting modes and device architectures. Here, to elucidate the working principles, we provide a Perspective on the device structures and the operational principles of halide perovskite direct conversion detectors for radiation sensing. We will first discuss different detection modes and introduce the commonly used device architectures and their working principles. Based on our work and pioneer developments in the field, we will next compare the performances of the reported detectors. Additionally, we will summarize the single crystal detectors and polycrystalline thin film devices and discuss their advantages and disadvantages for different applications. Finally, we provide a future Perspective on the critical problems that must be addressed to commercialize this technology.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Design and Characterization of an Extremely-Sensitive, Large-Volume Gamma-Ray Spectrometer for Environmental Samples

A large volume gamma spectrometer was designed and constructed to analyze foodstuffs and environmental samples having low radionuclide concentrations. This system uses eight 11-cm × 42.5-cm × 5.5-cm NaI(Tl) detectors, chosen due to their relatively high sensitivity and availability and arranged in an octagonal configuration. The sensitive volume of the system is ~28 cm in diameter and ~42 cm deep. Shielding consists of an 86-cm × 86-cm square, 64-cm-tall lead brick enclosure with 18-cm-thick lead walls lined by 0.3-cm-thick copper plates. An aluminum top was machined to suspend the detectors within this shield. The shielding reduces background counts by 72% at 100 keV and 42% at 1,000 keV. The positional variability in sensitivity of the well was determined by both simulation and experiment. A 2.1-L volume of nearly uniform sensitivity, varying less than 10%, exists in the well's center. Energy resolutions of 14.6% and 7.8% were measured for 241 Am and 137 Cs, respectively. Energy resolution shows a 0.2% variation for both 241 Am and 137 Cs as a function of position within all regions of the well’s central sensitive volume. Dead time was also determined to be less than 35% for all sources measured in the system, the largest of which had an activity of 1,760 kBq. Simulated results for various source geometries show higher counts for smaller samples, especially at lower energies due to less attenuation of low energy photons. In conclusion, minimum detectable activities were determined for all source energies used, less than 5.1 Bq kg -1 for reasonable background and sample counting times.

47 OTHER INSTRUMENTATION↗

Potential neutron-induced γ-ray background on natural tellurium relevant to 130 Te 0 ν ββ decay searches at the CUORE and SNO+ detectors

Gamma-ray production cross-section data have been obtained for the inelastic neutron scattering reactions 126,128,130 Te(n,n'γ) at five neutron energies between 3.6 and 10 MeV. We report data for the γ-ray energy region relevant to 0ν ββ decay of 130 Te with a Q ββ value of 2527.515 keV, assuming natural-abundance tellurium, as used at CUORE and SNO+. The natural abundance of 130 Te, 128 Te, and 126 Te is 34%, 32%, and 19%, respectively. For CUORE the γ-ray cascades from the excited state in 130 Te at 2527.06 keV and in 126 Te at 2533.85 keV are of concern. For SNO+, accounting for its inferior energy resolution, an additional four levels are important in 130 Te, an additional nine levels in 128 Te, and an additional eight levels in 126 Te. Of these, we report neutron-induced γ-ray production cross sections for the strongest transitions: the 2581.15 keV level in 130 Te, the 2494.20, 2508.06, and 2630.14 keV levels in 128 Te, and the 2496.83 and 2585.46 keV level in 126 Te. Here, the largest cross-section values were found for cascade γ-ray transitions to the ground state, while direct transitions to the ground state are very weak and were not observed in the present work. Both the CUORE and SNO+ detectors, however, may not be able to distinguish between cascade transitions and direct transitions to the ground state, making the neutron-induced excitation of the 2527.06 keV state of 130 Te in particular a potential problem for 0νββ decay searches of 130Te, because it matches its Q ββ value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of B 11 and Ca 40 levels at 8–9 MeV by nuclear resonance fluorescence

Here, we report on the measurement of 11 B and 40 Ca levels between excitation energies of 8 and 9 MeV using nuclear resonance fluorescence (NRF). The experiment was carried out with nearly monoenergetic and linearly polarized photon beams provided by the High-Intensity γ-ray Source (HIγS) facility at the Triangle Universities Nuclear Laboratory (TUNL). States in 11 B are important for calibrations of NRF measurements, while the properties of 40 Ca levels impact potassium nucleosynthesis in globular clusters. For 40 Ca, we report on improved excitation energies and an unambiguous 2¯ assignment for the state at 8425 keV. For 11 B, we obtained improved values for γ-ray multipolarity mixing ratios and branching ratios of the 8920-keV level.

39 ≤ A ≤ 58↗

Coexistence of single-particle and collective excitation in Ni 61

Here, the high-spin states in 61 Ni have been studied using the fusion evaporation reaction, 50 Ti( 14 C, 3n) 61 Ni at an incident beam energy of 40 MeV. A Compton suppressed multi-HPGe detector setup, consisting of six clover detectors and three single-crystal HPGe detectors, was used to detect the de-exciting $\gamma$ rays from the excited states. The level scheme has been extended up to an excitation energy of 12.8 MeV and a tentative J π =35/2 + . The low-lying negative parity levels are found to be generated by single-particle excitation within the fp shell and also excitations to the g 9/2 orbitals as explained well with shell model calculations using the GXPF1Br+V MU (modified) interaction. Two rotational structures of regular E2 sequences with small to moderate axial deformation have been established at higher excitation energy. Most interestingly, two sequences of M1 transitions are reported for the first time and described as magnetic rotational bands. The shears mechanism for both the bands can be described satisfactorily by the geometrical model. The shell model calculation involving the cross shell excitation beyond the fp shell well reproduce the M1 and E2 sequences. The shell model predicted B(M1) values for the magnetic rotational band B1 show the decreasing trend with spin as expected with closing of the shears.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constraining the P 30 ( p , γ ) S 31 Reaction Rate in ONe Novae via the Weak, Low-Energy, β -Delayed Proton Decay of Cl 31

The 30 P(p,γ) 31 S reaction plays an important role in understanding the nucleosynthesis of A ≥ 30 nuclides in oxygen-neon novae. The Gaseous Detector with Germanium Tagging was used to measure 31 Cl β-delayed proton decay through the key J π = 3/2 + , 260-keV resonance. The intensity $I$$^{260}_{βp}$ = $8.3$$^{+1.2}_{–0.9}$ × 10 –6 represents the weakest β-delayed, charged-particle emission ever measured below 400 keV, resulting in a proton branching ratio of Γ p /Γ = $2.5$$^{+0.4}_{–0.3}$ × 10 –4 . Here, by combining this measurement with shell-model calculations for Γγ and past work on other resonances, the total 30 P(p,γ) 31 S rate has been determined with reduced uncertainty. The new rate has been used in hydrodynamic simulations to model the composition of nova ejecta, leading to a concrete prediction of 30 Si: 28 Si excesses in presolar nova grains and the calibration of nuclear thermometers.

79 ASTRONOMY AND ASTROPHYSICS↗

Gamma Decay of the 154 Sm Isovector Giant Dipole Resonance: Smekal-Raman Scattering as a Novel Probe of Nuclear Ground-State Deformation

𝛾 decays of the isovector giant dipole resonance (IVGDR) of the deformed nucleus 154 Sm were measured using 2$^{+}_{1}$-Smekal-Raman and elastic scattering of linearly polarized, quasimonochromatic photon beams. The two scattering processes were disentangled through their distinct angular distributions. Their branching ratio and cross sections were determined at six excitation energies covering the 154 Sm IVGDR. Both agree with the predictions of the geometrical model for the IVGDR and confirm 𝛾 decay as an observable sensitive to the structure of the resonance. Consequently, the data place strong constraints on the nuclear shape, including the degree of triaxiality. The derived 154 Sm shape parameters 𝛽 = 0.2925⁢(25) and 𝛾 = 5.0⁢(15)° agree well with other measurements and recent Monte Carlo shell-model calculations.

150 ≤ A ≤ 189↗

Enhanced sensitivity to trace 238 U impurity of sapphire via coincidence neutron activation analysis

Sapphire has mechanical and electrical properties that are advantageous for the construction of internal components of radiation detectors such as time projection chambers and bolometers. However, it has proved difficult to assess its 232 Th and 238 U content down to the picogram per gram level. Here, this work reports an experimental verification of a computational study that demonstrates 𝛾⁢𝛾 coincidence counting, coupled with neutron activation analysis (NAA), can reach ppt sensitivities. Combining results from 𝛾⁢𝛾 coincidence counting with those of earlier single-𝛾 counting based NAA shows that a sample of Saint Gobain sapphire has 232 Th and 238 U concentrations of <0.26 ppt and <2.3 ppt, respectively; the best constraints on the radiopurity of sapphire.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimization Simulations for a Gamma-Ray Calibration Standard for a Cyclic Neutron Activation Analysis Pneumatic System at the Penn State Breazeale Reactor

For new experimental setups, the initial testing and calibrations can be expensive and time consuming without prior optimization. However, these issues can be mitigated using realistic modeling and simulation studies of the proposed system a priori. Specifically, an experiment can be performed virtually using realistic simulations and the expected results evaluated to inform adjustments of the experimental setup to achieve optimum results. At the Penn State Breazeale Reactor, a new pneumatic transfer system has been developed for the detection and characterization of short-lived fission fragments to enhance and complement existing nuclear data. The system accomplishes this task by transporting samples cyclically between an assortment of gamma-ray/neutron detectors and the reactor-core vicinity with sub-second transit times. The measured neutron flux paired with simulations of detector response using Geant4 and a custom module for estimating cascade summing effects and corrections were used to select sample-material masses for system characterization. With the optimized sample masses, an experimental counting plan for characterizing the repeatability of the newly developed pneumatic system was developed. Finally, the predictions made with these simulations allowed for optimization of the irradiation sample characteristics and gamma-ray detection system.

cyclic neutron activation, gamma-ray spectroscopy↗

Correlations Between Panoramic Imagery and Gamma-Ray Background in an Urban Area

When searching for radiological sources in an urban area, a vehicle-borne detector system will often measure complex, varying backgrounds primarily from natural gamma-ray sources. Much work has been focused on developing spectral algorithms that retain sensitivity and minimize the false-positive rate even in the presence of such spectral and temporal variability. However, information about the environment surrounding the detector system might also provide useful clues about the expected background, which if incorporated into an algorithm, could improve performance. Recent work has focused on extensive measuring and modeling of urban areas with the goal of understanding how these complex backgrounds arise. This work presents an analysis of panoramic video images and gamma-ray background data collected in Oakland, California, by the radiological multisensor analysis platform (RadMAP) vehicle. Features were extracted from the panoramic images by semantically labeling the images and then convolving the labeled regions with the detector response. A linear model was used to relate the image-derived features to gamma-ray spectral features obtained using nonnegative matrix factorization (NMF) under different regularizations. Here we find some gamma-ray background features correlate strongly with image-derived features that measure the response-adjusted solid angle subtended by sky and buildings, and we discuss the implications for the development of future, contextually aware detection algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above 1.4×10 –48 cm 2 for a WIMP mass of 40GeV/c 2 and a 1000 days exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and bespoke detector systems to assay scintillator are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Erratum to: The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above 1.4 × 10 -48 cm 2 for a WIMP mass of 40 GeV/c 2 and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and be spoke detector systems to assay scintillator are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Geant4 based positron beam source (GPos) v1.0

GPos is a software that was created to determine the properties of positron beams resulting from the interaction of the LBNL BELLA center PetaWatt laser-driven plasma-capillary accelerated electron beam and the atoms of a thin solid target. GPos is written in C++, easily compiled with cmake and the spack package manager, which allows for multi-thread and MPI parallel computing. Its functions expand on the Geant4 toolkit library and allow for propagation of the modelled particles through vacuum drift distances with a focusing element (thin lens approximation). Users can change beam-foil-drift-lens parameters - to adapt GPos to other particle sources and infrastructures - in a simple input file. The code particle data output format, openPMD, which is compatible, for example, with the input of the ECP WarpX project code used to explore the physics of particle acceleration in plasmas. Using GPos in conjunction to WarpX allowed us to test various configurations for designing a high-quality and high-energy positron source at BELLA -required for us to address positron acceleration challenges in the development of future linear colliders. GPos can also be advantageous when tackling the physics of muon sources for future muon colliders as well as for the investigation of positron sources in lower energy regimes for applications like annihilation spectroscopy and astrophysical gamma-ray-bursts.

Pinto de Almeida Amorim, Ligia↗

Automated Internal Energy Calibration by OnTheFly for AGR-5/6/7

The software program, OnTheFly, was developed at Idaho National Laboratory (INL) to keep high-purity germanium (HPGe) detectors energy calibrated during very long experiments. Over time, spectra produced from a HPGe detector will slowly stretch or contract, causing the energy calibration to change. If the energy calibration changes too much, it will cause energy lines to be misidentified. The higher the energy line the more affected they are by this change. OnTheFly tracks and adjusts the slowly changing energy calibrations so the energy lines will not be misidentified. OnTheFly was used with the Fission Product Monitoring System (FPMS) during the AGR-5/6/7 irradiation experiment performed at INL’s Advanced Test Reactor (ATR). Five HPGe detectors were used to monitor the five capsules in AGR-5/6/7. There were also two extra HPGe detectors that were maintained as spares. Before each ATR cycle of the experiment, the HPGe detectors were energy calibrated with a thorium radioactive source. During each ATR cycle, each detector would acquire data for 8 hours and then reset and acquire data for another 8 hours. After each 8-hour run, the spectra would be saved and analyzed autonomously. The results were then read by OnTheFly and used to produce a new energy calibration for each detector. The new energy calibrations were compared to the current energy calibrations and, if certain criteria were met, the new energy calibration would replace the current energy calibration. The new energy calibration would be used for future spectra. OnTheFly was run at least every couple of days but could be run as much as after each 8-hour run. OnTheFly kept the spectra energy calibrated during the ATR cycles over the 2 years and 5 months that the AGR-5/6/7 experiment ran.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗