Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Measurement of neutron dose equivalent outside and inside of the treatment vault of GRID therapy

Purpose: To evaluate the neutron and photon dose equivalent rates at the treatment vault entrance (H{sub n,D} and H{sub G}), and to study the secondary radiation to the patient in GRID therapy. The radiation activation on the grid was studied.Methods: A Varian Clinac 23EX accelerator was working at 18 MV mode with a grid manufactured by .decimal, Inc. The H{sub n,D} and H{sub G} were measured using an Andersson–Braun neutron REM meter, and a Geiger Müller counter. The radiation activation on the grid was measured after the irradiation with an ion chamber γ-ray survey meter. The secondary radiation dose equivalent to patient was evaluated by etched track detectors and OSL detectors on a RANDO{sup ®} phantom.Results: Within the measurement uncertainty, there is no significant difference between the H{sub n,D} and H{sub G} with and without a grid. However, the neutron dose equivalent to the patient with the grid is, on average, 35.3% lower than that without the grid when using the same field size and the same amount of monitor unit. The photon dose equivalent to the patient with the grid is, on average, 44.9% lower. The measured average half-life of the radiation activation in the grid is 12.0 (±0.9) min. The activation can be categorized into a fast decay component and a slow decay component with half-lives of 3.4 (±1.6) min and 15.3 (±4.0) min, respectively. There was no detectable radioactive contamination found on the surface of the grid through a wipe test.Conclusions: This work indicates that there is no significant change of the H{sub n,D} and H{sub G} in GRID therapy, compared with a conventional external beam therapy. However, the neutron and scattered photon dose equivalent to the patient decrease dramatically with the grid and can be clinical irrelevant. Meanwhile, the users of a grid should be aware of the possible high dose to the radiation worker from the radiation activation on the surface of the grid. A delay in handling the grid after the beam delivery is suggested.

61 RADIATION PROTECTION AND DOSIMETRY↗

Two-Stage Optimization Framework for Detecting and Correcting Parameter Cyber-Attacks in Power System State Estimation

One major tool of Energy Management Systems for monitoring the status of the power grid is State Estimation. Since the results of state estimation are used within the energy management system, the security of the state estimation process is most important. The focus research in this area is on detecting False Data Injection attacks on measurements. While this is important, State Estimation also rely on database that are used to describe the relationship between measurements and systems' states. This paper presents a two-stage programming framework to detect and correct attacks in the parameters of the measurement model used by the state estimation process in the Energy Management System. In the first stage, an estimate of the line parameters ratios are obtained. In the second stage, the estimated ratios from stage I are used in a Bi-Level model for obtaining a final estimate of the measurements' model parameters. Hence, the presented framework does not only unify the detection and correction in a single optimization run, but also provide a monitoring scheme for the SE database that is typically considered static. In addition, in the two stages, linear programming framework is preserved. For validation, the IEEE 118 bus system is used for implementation. The results of this paper illustrate the effectiveness of the proposed model for detecting attacks in the database used in the state estimation process.

state estimation, two-stage optimization, cyber-ph↗

Cyber–Physical System Security of Distribution Systems

The Information and Communications Technology (ICT) for control and monitoring of power systems is a layer on top of the physical power system infrastructure. The cyber system and physical power system components form a tightly coupled Cyber–Physical System (CPS). Sources of vulnerabilities arise from the computing and communication systems of the cyber–power grid. Cyber intrusions targeting the power grid are serious threats to the reliability of electricity supply that is critical to society and the economy. In a typical Information Technology environment, numerous attack scenarios have shown how unauthorized users can access and manipulate protected information from a network domain. The need for cyber security has led to industry standards that power grids must meet to ensure that the monitoring, operation, and control functions are not disrupted by cyber intrusions. Cyber security technologies such as encryption and authentication have been deployed on the CPS. Intrusion or anomaly detection and mitigation tools developed for power grids are emerging. Furthermore, this survey paper provides the basic concepts of cyber vulnerabilities of distribution systems and CPS security. The important ICT subjects for distribution systems covered in this paper include Supervisory Control And Data Acquisition, Distributed Energy Resources, including renewable energy and smart meters.

97 MATHEMATICS AND COMPUTING↗

SunEdison Photovoltaic Grid Integration Evaluation (CRADA Final Report)

Under this Agreement, NREL will work with SunEdison to monitor and analyze the performance of photovoltaic (PV) systems as they relate to grid integration. Initially this project will examine the performance of PV systems with respect to evaluating the benefits and impacts on the electric power grid.

14 SOLAR ENERGY↗

Quality Assurance Framework for Mini-Grids

Providing clean and affordable energy services to the more than 1 billion people globally who lack access to electricity is a critical driver for poverty reduction, economic development, improved health, and social outcomes. More than 84% of populations without electricity are located in rural areas where traditional grid extension may not be cost-effective; therefore, distributed energy solutions such as mini-grids are critical. To address some of the root challenges of providing safe, quality, and financially viable mini-grid power systems to remote customers, the U.S. Department of Energy (DOE) teamed with the National Renewable Energy Laboratory (NREL) to develop a Quality Assurance Framework (QAF) for isolated mini-grids. The QAF for mini-grids aims to address some root challenges of providing safe, quality, and affordable power to remote customers via financially viable mini-grids through two key components: (1) Levels of service: Defines a standard set of tiers of end-user service and links them to technical parameters of power quality, power availability, and power reliability. These levels of service span the entire energy ladder, from basic energy service to high-quality, high-reliability, and high-availability service (often considered 'grid parity'); (2) Accountability and performance reporting framework: Provides a clear process of validating power delivery by providing trusted information to customers, funders, and/or regulators. The performance reporting protocol can also serve as a robust monitoring and evaluation tool for mini-grid operators and funding organizations. The QAF will provide a flexible alternative to rigid top-down standards for mini-grids in energy access contexts, outlining tiers of end-user service and linking them to relevant technical parameters. In addition, data generated through implementation of the QAF will provide the foundation for comparisons across projects, assessment of impacts, and greater confidence that will drive investment and scale-up in this sector. The QAF implementation process also defines a set of implementation guidelines that help the deployment of mini-grids on a regional or national scale, helping to insure successful rapid deployment of these relatively new remote energy options. Note that the QAF is technology agnostic, addressing both alternating current (AC) and direct current (DC) mini-grids, and is also applicable to renewable, fossil-fuel, and hybrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Secure Interoperable Open Smart Grid Demonstration Project

The Consolidated Edison, Inc., of New York (Con Edison) Secure Interoperable Open Smart Grid Demonstration Project (SGDP), sponsored by the United States (US) Department of Energy (DOE), demonstrated that the reliability, efficiency, and flexibility of the grid can be improved through a combination of enhanced monitoring and control capabilities using systems and resources that interoperate within a secure services framework. The project demonstrated the capability to shift, balance, and reduce load where and when needed in response to system contingencies or emergencies by leveraging controllable field assets. The range of field assets includes curtailable customer loads, distributed generation (DG), battery storage, electric vehicle (EV) charging stations, building management systems (BMS), home area networks (HANs), high-voltage monitoring, and advanced metering infrastructure (AMI). The SGDP enables the seamless integration and control of these field assets through a common, cyber-secure, interoperable control platform, which integrates a number of existing legacy control and data systems, as well as new smart grid (SG) systems and applications. By integrating advanced technologies for monitoring and control, the SGDP helps target and reduce peak load growth, improves the reliability and efficiency of Con Edison’s grid, and increases the ability to accommodate the growing use of distributed resources. Con Edison is dedicated to lowering costs, improving reliability and customer service, and reducing its impact on the environment for its customers. These objectives also align with the policy objectives of New York State as a whole. To help meet these objectives, Con Edison’s long-term vision for the distribution grid relies on the successful integration and control of a growing penetration of distributed resources, including demand response (DR) resources, battery storage units, and DG. For example, Con Edison is expecting significant long-term growth of DG. The SGDP enables the efficient, flexible integration of these disparate resources and lays the architectural foundations for future scalability. Con Edison assembled an SGDP team of more than 16 different project partners, including technology vendors, and participating organizations, and the Con Edison team provided overall guidance and project management. Project team members are listed in Table 1-1.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Study of ion flow dynamics in an inertial electrostatic confinement device through sequential grid construction

Experiments were performed to understand the dynamics of the ion flow in an inertial electrostatic confinement (IEC) device. This was done by monitoring the fusion rate as the symmetry of the grid was increased starting with a single loop all the way until the entire grid is constructed. The fusion rate was observed to increase with grid symmetry and eventually saturate. A single loop grid was observed to generate a cylindrical ({approx}line) fusion source. The ion flow distribution was measured by introducing fine wires across a single loop of the grid in the form of a chord of a circle (chord wires). This study revealed that with increased symmetry of the cathode grid wires the convergence of the ions improves. The chord wires provided electrons for ionization even at low pressures ({approx}6.67 mPa) and helped sustain the plasma. The impinging ions heat these wires locally and the temperature of the wires was measured using an infrared thermometer that was used to understand the ion flow distribution across the cathode grid. The presence of the grid wires seems to affect the fusion rate more drastically than previously thought (was assumed to be uniform around the central grid). Most of the fusion reactions were observed to occur in the ion microchannels that form in gaps between the cathode wires. This work helps understand the fusion source regimes and calibrate the IEC device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scanned Carbon Pencil Beams for Tumor Therapy

At GSI a fully active beam application has been developed for tumor therapy with carbon ions. In this so-called rasterscan system the tumor volume is typically split into {approx}60 slices of iso-energies taken from a list of 252 energies ranging from {approx}90-430 MeV/u(range: 1.8-30.7 cm). The energies can be combined with variable beam diameters and intensities. For each iso-energy slice beam is requested from the synchrotron and delivered as a narrow pencil beam (beam's full width at half maximum 3-10 mm). For lateral target coverage this pencil beam is deflected to several hundreds of grid positions per iso-energy slice by orthogonal dipole magnets. At each grid position an optimized number of particles is deposited intensity-controlled, i.e. ionization chambers monitor the dose deposition and trigger deflection to the next grid position once the required dose level is achieved. This method allows intensity-modulated treatment fields necessary to deposit a uniform biological effective dose. Additionally, it allows for simultaneous optimization of multiple fields that allow better sparing of organs at risk partially or fully surrounded by the tumor. Scanned beam delivery facilitates target conformal and homogeneous dose delivery for stationary targets. For tumors located in the head and neck as well as tumors in the pelvic region very promising results were achieved in the carbon therapy pilot project started at GSI in 1993. A comparable project is conducted at Paul-Scherrer-Institut (PSI) in Switzerland with a scanned proton beam. One of the current research topics is the treatment of moving targets such as lung tumors. Scanned beam delivery requires but also offers possibilities to conformably irradiate moving target sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects-Based Monitoring of Geomagnetically-Induced Current Using a Convolutional Neural Network

Geomagnetically-induced current (GIC) due to space weather can flow in the power grid causing undesirable effects such as transformer overheating, misoperation of protection devices, and potential blackouts. It is therefore important to monitor GIC in the power grid to improve online situational awareness and decision-making of system operators during a geomagnetic disturbance. To avoid the costly installation of GIC monitors at transformers’ neutrals, it is desirable to find correlations between GIC and already-monitored parameters. Hence, this work proposed the use of a convolutional neural network (CNN) to compute GIC amplitudes from learned patterns in the time-series data of transformer even harmonic currents. Using an electromagnetic transient program, GIC injection simulations were performed for a modeled Dominion Energy Virginia (DEV) substation with two 504 MVA, 500/230 kV transformers. Data collected from these offline simulations were used to train the CNN to provide online GIC monitoring. Testing the CNN performance involved using real GIC measurements from published literature and from a physical GIC monitor in the DEV area. Finally, the results showed that the proposed method was able to provide GIC readings with a root mean squared error of 1.56 A/phase (equivalent to an average accuracy of 94%) for these real GIC waveforms.

42 ENGINEERING↗

CMS centres worldwide: A new collaborative infrastructure

The CMS Experiment at the LHC has established a network of more than fifty inter-connected 'CMS Centres' at CERN and in institutes in the Americas, Asia, Australasia, and Europe. These facilities are used by people doing CMS detector and computing grid operations, remote shifts, data quality monitoring and analysis, as well as education and outreach. We present the computing, software, and collaborative tools and videoconferencing systems. These include permanently running 'telepresence' video links (hardware-based H.323, EVO and Vidyo), Webcasts, and generic Web tools such as CMS-TV for broadcasting live monitoring and outreach information. Being Web-based and experiment-independent, these systems could easily be extended to other organizations. We describe the experiences of using CMS Centres Worldwide in the CMS data-taking operations as well as for major media events with several hundred TV channels, radio stations, and many more press journalists simultaneously around the world.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Introduction to the Special Section on Control and Management of Electric Power Systems With High Shares of Inverter-Based Resources

The growing interest in the integration of variable renewable energy (VRE) and distributed energy resources (DER) on both policy and economic grounds is driving the transformation of electric power systems. The significant deployment of VRE and DER can effectively displace the conventional synchronous generator-based power plants that for decades have been the foundation for power system generation and stability in electric power systems. Inverter-based resources (IBRs) introduce a high-level of uncertainty, variability, and complexity into the operation of electric power networks, and the transformation to IBRs raises a wide range of technical questions and operational challenges. The optimal coordination and control of these resources requires greater interoperability and necessitates significant upgrades of grid automation, including real-time monitoring.

distributed power generation↗

Distributed Dynamic State Estimation with Extended Kalman Filter

Increasing complexity associated with large-scale renewable resources and novel smart-grid technologies necessitates real-time monitoring and control. Our previous work applied the extended Kalman filter (EKF) with the use of phasor measurement data (PMU) for dynamic state estimation. However, high computation complexity creates significant challenges for real-time applications. In this paper, the problem of distributed dynamic state estimation is investigated. One domain decomposition method is proposed to utilize decentralized computing resources. The performance of distributed dynamic state estimation is tested on a 16-machine, 68-bus test system.

42 ENGINEERING↗

Role of the Reference Bus in Three-Phase State Estimation

As more and more renewable energy sources are being connected to the power grid at lower voltage levels, closer monitoring of distribution networks is becoming a necessity. This is accomplished by state estimation and deployment of Distribution Management Systems (DMS). Distribution feeders are typically untransposed with unbalance loads. Thus, their modeling and analysis show significant differences compared to those for transmission networks. This paper focuses on the state estimation problem and its formulation for unbalanced distribution systems. Specifically, it is concerned about the modeling and solution of three-phase networks without a fully balanced bus to be selected as the angle reference. It is shown that best results will be obtained via the use of a virtual symmetrical bus. Validation of the proposed formulation is carried out by simulations.

Langner, A. L.↗

Multi-Objective PMU Allocation for Resilient Power System Monitoring

Phasor measurement units (PMUs) enable better system monitoring and security enhancement in smart grids. In order to enhance power system resilience against outages and blackouts caused by extreme weather events or man-made attacks, it remains a major challenge to determine the optimal number and location of PMUs. In this paper, a multi-objective resilient PMU placement (MORPP) problem is formulated, and solved by a modified Teaching-Learning-Based optimization (MO-TLBO) algorithm. Three objectives are considered in the MORPP problem, minimizing the number of PMUs, maximizing the system observability, and minimizing the voltage stability index. The effectiveness of the proposed method is validated through testing on IEEE 14-bus, 30-bus, and 118-bus test systems. The advantage of the MO-TLBO-based MORPP is demonstrated through the comparison with other methods in the literature, in terms of iteration number, optimality and time of convergence.

Multi-Objective Optimization↗

Self-reported Impacts of LED Lighting Technology Compared to Fuel-based Lighting on Night Market Business Prosperity in Kenya

The notion of"productive use" is often invoked in discussions about whether new technologies improve productivity or otherwise enhance commerce in developing-country contexts. It an elusive concept,especially when quantitative measures are sought. Improved and more energy efficient illumination systems for off-gridapplication--the focus of the Lumina Project--provide a case in which a significant productivity benefit can be imagined, given the importance of light to the successful performance of many tasks, and the very low quality of baseline illumination provided by flame-based source. This Research Note summarizes self-reported quantitative and qualitative impacts of switching to LED lighting technology on the prosperity of night-market business owners and operators. The information was gathered in the context of our 2008 market testing field work in Kenya?s Rift Valley Province, which was performed in the towns of Maai Mahiu and Karagita by Arne Jacobson, Kristen Radecsky, Peter Johnstone, Maina Mumbi, and others. Maai Mahiu is a crossroads town; provision of services to travelers and freight carriers is a primary income source for the residents. In contrast, the primary income for Karagita's residents is from work in the large, factory style flower farms on the eastern shores of Lake Naivasha that specialize in producing cut flowers for export to the European market. According to residents, both towns had populations of 6,000 to 8,000 people in June 2008. We focused on quantifying the economics of fuel-based and LED lighting technology in the context of business use by night market vendors and shop keepers. Our research activities with the business owners and operators included baseline measurement of their fuel-based lighting use, an initial survey, offering for sale data logger equipped rechargeable LED lamps, monitoring the adoption of the LED lamps, and a follow-up survey.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The dynamic expansion and contraction of the Jovian plasma sheet

Observations suggesting the sequential expansion and compression of the Jovian plasma sheet are reported. Plasma flow in the vicinity of Jupiter was monitored by the four modulated-grid Faraday cups on board each of the Voyager spacecraft at times of closest Jupiter approach. Sensor measurements reveal the flow of magnetospheric plasma to be directed away from the equatorial current sheet near local noon and to be directed towards the sheet in the dusk to midnight sector. The observed flow patterns are interpreted in terms of short-time-scale perturbations of magnetic flux tubes due to the compression of the dayside magnetosphere by the solar wind. It is noted that such a dynamic motion is quite different from what would be expected of slower, quasi-static equilibrium plasma sheet expansion and contraction.

Belcher, J. W.↗

Telescience Support Center Data System Software

The Telescience Support Center (TSC) team has developed a databasedriven, increment-specific Data Require - ment Document (DRD) generation tool that automates much of the work required for generating and formatting the DRD. It creates a database to load the required changes to configure the TSC data system, thus eliminating a substantial amount of labor in database entry and formatting. The TSC database contains the TSC systems configuration, along with the experimental data, in which human physiological data must be de-commutated in real time. The data for each experiment also must be cataloged and archived for future retrieval. TSC software provides tools and resources for ground operation and data distribution to remote users consisting of PIs (principal investigators), bio-medical engineers, scientists, engineers, payload specialists, and computer scientists. Operations support is provided for computer systems access, detailed networking, and mathematical and computational problems of the International Space Station telemetry data. User training is provided for on-site staff and biomedical researchers and other remote personnel in the usage of the space-bound services via the Internet, which enables significant resource savings for the physical facility along with the time savings versus traveling to NASA sites. The software used in support of the TSC could easily be adapted to other Control Center applications. This would include not only other NASA payload monitoring facilities, but also other types of control activities, such as monitoring and control of the electric grid, chemical, or nuclear plant processes, air traffic control, and the like.

Rahman, Hasan↗

Lightning NOx Production in the Tropics as Determined Using OMI NO2 Retrievals and WWLLN Stroke Data

Nitrogen oxide (NOx) production by lightning in the tropics is estimated using tropospheric NOx amounts (LNOx*) over deep convective grid boxes derived from OMI (Ozone Monitoring Instrument) nitrogen dioxide (NO2) slant columns and detection efficiency adjusted WWLLN (World Wide Lightning Location Network) flashes. The lightning NOx production efficiency (LNOx PE) in the tropics is determined for the austral and boreal summers of 2007 to 2011 by regressing regional mean daily values of LNOx* for individual seasons against daily flash totals during flash windows prior to the OMI overpass. LNOx PE is determined to be approximately two times larger over marine locations than over continental locations possibly because marine flashes are more energetic. Overall, the mean LNOx PE for the tropics is calculated to be 170 ± 100 mol per flash with values over the tropical Pacific (low flash rate region) being largest. The main contributors to uncertainties in PE are uncertainties in WWLLN flash detection efficiency, upper tropospheric NOx lifetime in the near field of convection, and air mass factor biases.

Dale J. Allen↗