Search NASA⌕ Search

SEARCH · Search NASA

Results for “heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Mesoscale evolution of voids and microstructural changes in HMX-based explosives during heating through the β-δ phase transition

HMX-based explosives LX-10 and PBX-9501 were heated through the β-δ phase transition. Ultra-small angle x-ray scattering (USAXS) and molecular diffraction were simultaneously recorded as the HMX was heated. Mesoscale voids and structure dramatically change promptly with the β-δ phase transition, rather than with other thermal effects. Also, x-ray induced damage, observed in the USAXS, occurs more readily at elevated temperatures; as such, the dose was reduced to mitigate this effect. Optical microscopy performed during a similar heating cycle gives an indication of changes on longer length scales, while x-ray microtomography, performed before and after heating, shows the character of extensive microstructural damage resulting from the temperature cycle and solid-state phase transition.

36 MATERIALS SCIENCE↗

Effect of the scrape-off layer in AORSA full wave simulations of fast wave minority, mid/high harmonic, and helicon heating regimes

Several experiments on different machines and in different fast wave (FW) heating regimes, such as hydrogen minority heating and high harmonic fast waves, have found strong interactions between radio-frequency (RF) waves and the scrape-off layer (SOL) region. This paper examines the propagation and the power loss in the SOL by using the full wave code AORSA, in which the edge plasma beyond the last closed flux surface (LCFS) is included in the solution domain and a collisional damping parameter is used as a proxy to represent the real, and most likely nonlinear, damping processes. 3D AORSA results for the National Spherical Torus eXperiment (NSTX), where a full antenna spectrum is reconstructed, are shown, confirming the same behavior found for a single toroidal mode results in Bertelli et al, Nucl. Fusion, 54 083004, 2014, namely, a strong transition to higher SOL power losses (driven by the RF field) when the FW cut-off is moved away from in front of the antenna by increasing the edge density. Additionally, full wave simulations have been extended to “conventional” tokamaks with higher aspect ratios, such as the DIII-D, Alcator C-Mod, and EAST devices. DIII-D results show similar behavior found in NSTX and NSTX-U, consistent with previous DIII-D experimental observations. In contrast, a different behavior has been found for Alcator C-Mod and EAST, which operate in the minority heating regime unlike NSTX/NSTX-U and DIII-D, which operate in the mid/high harmonic regime. A substantial discussion of some of the main aspects, such as (i) the pitch angle of the magnetic field; (ii) minority heating vs. mid/high harmonic regimes is presented showing the different behavior of the RF field in the SOL region for NSTX-U scenarios with different plasma current. Finally, the preliminary results of the impact of the SOL region on the evaluation of the helicon current drive efficiency in DIII-D is presented for the first time and briefly compared with the different regimes mentioned above.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extreme ultra-violet burst, particle heating, and whistler wave emission in fast magnetic reconnection induced by kink-driven Rayleigh-Taylor instability

A spatially localized energetic extreme ultra-violet (EUV) burst is imaged at the presumed position of fast magnetic reconnection in a plasma jet produced by a coaxial helicity injection source; this EUV burst indicates strong localized electron heating. A circularly polarized high frequency magnetic field perturbation is simultaneously observed at some distance from the reconnection region indicating that the reconnection emits whistler waves and that Hall dynamics likely governs the reconnection. Spectroscopic measurement also shows simultaneous fast ion heating. The electron heating is consistent with Ohmic dissipation, while the ion heating is consistent with ion trajectories becoming stochastic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysing the effects of heating and gas puffing in Proto-MPEX helicon and auxiliary heated plasmas

The Material Plasma Exposure Experiment (MPEX) is being constructed at Oak Ridge National Laboratory to investigate critical fusion reactor issues, such as plasma–material interactions (PMIs) under reactor-relevant conditions and time scales. The linear device Proto-MPEX was used as a test bed to address anticipated research and development issues associated with heating scenarios and establish the physics basis for MPEX. The SOLPS-ITER code suite has been applied to understand plasma and neutral transport in Proto-MPEX and to increase confidence in predictive simulations for MPEX. Coupling between COMSOL and SOLPS is performed to implement a 2D electron heating profile of the helicon source. The simulations show reasonable agreement with the experimental data for plasma with helicon and auxiliary electron cyclotron heating (ECH). Both Bohm and constant diffusion (D$_\perp$: 0.5 m 2 s –1 and $\chi_\perp$: 1 m 2 s –1 ) simulations show similar levels of agreement with respect to the sparse experimental data available, assuming a few per cent impurity concentration. ECH significantly increases the target electron temperature, however, the target electron density is reduced compared to helicon-only heated plasmas due to an increase in flow velocity and radial losses. The simulations show that further increasing the ECH power results in an increase in the target electron density due to increased recycling flux and ionization. The results indicate that ECH significantly enhances the target heat flux, with ECH power of 50 kW increasing the target heat flux from 0.4 to 17 MW m –2 . It is found that a small amount of gas puffing (GP) near the target plate can further increase the target heat fluxes at the higher ECH power cases, but the target heat flux is reduced at higher GP conditions due to a significant reduction in electron temperature via radiation. ECH and GP scenarios can generate a higher target flux, facilitating improved PMI studies with more reactor-relevant plasma conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demand Response for Thermal Fairness in District Heating Networks

District Heating (DH) networks are complex thermal grids wherein a centrally heated fluid is circulated through a network of pipes and heat exchangers to meet the heating needs of residential and commercial buildings. Several factors can lead to inefficient and unfair energy distribution among consumers in these networks. These include varying levels of building insulation, distance of individual buildings from the central energy source, and thermal losses in network pipes. Moreover, shortage of energy at the central energy source and extreme weather conditions can exacerbate these issues, leading to differing levels of thermal comfort and customer disgruntlement in the long run. In this paper, we propose and study a demand response scheme that attempts to ensure thermal fairness among energy consumers in modern thermal grids. We develop optimization formulations based on thermodynamic models of DH networks, which determine optimal energy flow for individual buildings in order to achieve thermal fairness across the network. Our experimental results using physics based models for DH networks show that it is possible to achieve network level thermal fairness based social welfare objectives by controlling network parameters such as mass flow rates of water to the consumer premises and the supply water temperature, even when some network parameters like building thermal characteristics remain unknown.

Bhattacharya, Saptarshi↗

A software package for plasma facing component analysis and design: the Heat flux Engineering Analysis Toolkit (HEAT)

The engineering limits of plasma facing components (PFCs) constrain the allowable operational space of tokamaks. Poorly managed heat fluxes that push the PFCs beyond their limits not only degrade core plasma performance via elevated impurities, but can also result in PFC failure due to thermal stresses or melting. Simple axisymmetric assumptions fail to capture the complex interaction between 3D PFC geometry and 2D or 3D plasmas. This results in fusion systems that must either operate with increased risk or reduce PFC loads, potentially through lower core plasma performance, to maintain a nominal safety factor. High precision 3D heat flux predictions are necessary to accurately ascertain the state of a PFC given the evolution of the magnetic equilibrium. A new code, the Heat flux Engineering Analysis Toolkit (HEAT), has been developed to provide high precision 3D predictions and analysis for PFCs. HEAT couples many otherwise disparate computational tools together into a single open source python package. Magnetic equilibrium, engineering CAD, finite volume solvers, scrape off layer plasma physics, visualization, high performace computing, and more, are connected in a single web-based user interface. Linux users may use HEAT without any software prerequisites via an appImage. This manuscript introduces HEAT, discusses the software architecture, presents first HEAT results, and outlines physics modules in development.

divertor physics↗

RELAP5-3D Modeling of Heat Transfer Components (Intermediate Heat Exchanger and Helical-Coil Steam Generator) for NGNP Application

The Next Generation Nuclear Plant project is aimed at the research and development of a helium-cooled high-temperature gas reactor that could generate both electricity and process heat for the production of hydrogen. The heat from the high-temperature primary loop must be transferred via an intermediate heat exchanger to a secondary loop. Using RELAP5-3D, a model was developed for two of the heat exchanger options a printed-circuit heat exchanger and a helical-coil steam generator. The RELAP5-3D models were used to simulate an exponential decrease in pressure over a 20 second period. The results of this loss of coolant analysis indicate that heat is initially transferred from the primary loop to the secondary loop, but after the decrease in pressure in the primary loop the heat is transferred from the secondary loop to the primary loop. A high-temperature gas reactor model should be developed and connected to the heat transfer component to simulate other transients.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Influence of building heat distribution temperatures on the energy performance and sizing of 5th generation district heating and cooling networks

This paper investigates the energy performance and sizing criteria of 5th generation district heating and cooling (5GDHC) networks as a function of the heat distribution temperature in the building systems connected to the district network. An energy simulation model of a 5GDHC network was developed in Modelica for a case study located in Denmark. Calculations were carried out for four different building heating systems. Simulation results show that reducing the heat distribution temperatures from 70 °C to 23 °C leads to around 40% annual electric energy savings (from 10.4 kWh/m 2 to 6.2 kWh/m 2 ) for the operation of the heat pumps. Heat distribution temperatures of 23 °C cause higher water mass flow rates through the network, leading to annual electric energy consumption for the circulation pumps that are almost doubled (from 0.16 kWh/m 2 to 0.3 kWh/m 2 ) compared to the reference case at 70 °C. Furthermore, the paper discusses how the results obtained from the Danish case study can be generalized and applied to other cases using a simplified mathematical approach. In conclusion, it is found that about 1.5% of electric energy savings can be achieved for each temperature degree reduction in the heat distribution system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Exergy analysis and operational efficiency of a horizontal ground-source heat pump system operated in a low-energy test house simulated occupancy conditions

This paper presents detailed analysis of a water to water ground source heat pump (WW-GSHP) to provide all the hot water needs in a 345 m 2 house located in DOE climate zone 4 (mixed-humid). The protocol for hot water use is based on the Building America Research Benchmark Definition (Hendron 2008; Hendron and Engebrecht 2010) which aims to capture the living habits of the average American household and its impact on energy consumption. The entire house was operated under simulated occupancy conditions. Detailed energy and exergy analysis provides a complete set of information on system efficiency and sources of irreversibility, the main cause of wasted energy. The WW-GSHP was sized at 5.275 kW (1.5-ton) for this house and supplied hot water to a 303 L (80 gal) water storage tank. The WW-GSHP shared the same ground loop with a 7.56 kW (2.1-ton) water to air ground source heat pump (WA-GSHP) which provided space conditioning needs to the entire house. Data, analyses, and measures of performance for the WW-GSHP in this paper complements the results of the WA-GSHP published in this journal (Ally, Munk et al. 2012). Understanding the performance of GSHPs is vital if the ground is to be used as a viable renewable energy resource.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Local heat transfer measurement in a volumetrically heated TPMS lattice using distributed optical fiber thermal sensing

As additive manufacturing continues to reduce design constraints on heat exchange geometries, methods for high-fidelity local heat transfer measurements in nonconventional channel geometries are critical to their continued development. This study presents a novel method for measuring local heat transfer performance in volumetrically heated lattices using a distributed optical fiber temperature sensor. A diamond-type triply periodic minimal surface (TPMS) lattice, 3D-printed from a conductive polymer, was Joule heated while it was convectively cooled with air. Temperature measurements were taken at the solid–fluid interface across 14 internal locations using a single optical fiber over the Reynolds number range 800–2750. The TPMS lattice achieved up to 312% higher heat transfer coefficients compared to developing flow in a straight tube. A Nusselt number correlation was developed for the diamond TPMS, which showed good agreement with data collected for comparable geometries available in literature. In conclusion, this study presents a robust and new method for experimental measurement of the heat transfer coefficient in complex geometries and helps to understand and quantify the exceptional performance of TPMS heat transfer geometries.

TPMS↗

Techno-economic analysis of using corn stover to supply heat and power to a corn ethanol plant - Part 2: Cost of heat and power generation systems

This paper presents a techno-economic analysis of corn stover fired process heating (PH) and the combined heat and power (CHP) generation systems for a typical corn ethanol plant (ethanol production capacity of 170 dam3). Discounted cash flow method was used to estimate both the capital and operating costs of each system and compared with the existing natural gas fired heating system. Environmental impact assessment of using corn stover, coal and natural gas in the heat and/or power generation systems was also evaluated. Coal fired process heating (PH) system had the lowest annual operating cost due to the low fuel cost, but had the highest environmental and human toxicity impacts. The proposed combined heat and power (CHP) generation system required about 137 Gg of corn stover to generate 9.5 MW of electricity and 52.3 MW of process heat with an overall CHP efficiency of 83.3%. Stover fired CHP system would generate an annual savings of 3.6 M$ with an payback period of 6 y. Economics of the coal fired CHP system was very attractive compared to the stover fired CHP system due to lower fuel cost. But the greenhouse gas emissions per Mg of fuel for the coal fired CHP system was 32 times higher than that of stover fired CHP system. Corn stover fired heat and power generation system for a corn ethanol plant can improve the net energy balance and add environmental benefits to the corn to ethanol biorefinery.

CHP system↗

Numerical simulations of membrane distillation systems with actively heated membranes

Membrane distillation (MD) is a thermal desalination process that is gaining attention for treating hypersaline brines. One recent approach uses composite membranes with a thermally conductive layer that delivers heat to the membrane–feed interface, where it drives evaporation. Though this increases single-pass recovery, it comes with the challenge of promoting lateral heat conduction through the thin membrane. Herein, we develop a 3D, computational fluid dynamics (CFD) model that simulates conjugate heat, mass, and momentum transport in the feed channel and composite membrane. We then use the CFD to verify a simpler numerical model that approximates the feed velocity field analytically. We validate the numerical model experimentally, and use it to investigate the impacts of the conductive layer thickness, feed channel geometry, and operating conditions on temperature and concentration polarization, permeate production, and specific energy consumption. Overall, we find that lateral heating increases permeate production at the expense of increased concentration polarization. In extreme cases, the concentration increases more than four-fold along the membrane surface. Furthermore, we show however, that the feed flow rate and conductive layer thickness can be tailored to mitigate concentration polarization, for only a small reduction in permeate production.

42 ENGINEERING↗

Two interacting ethylene response factors regulate heat stress response

Abstract The ethylene response factor (ERF) transcription factors are integral components of environmental stress signaling cascades, regulating a wide variety of downstream genes related to stress responses and plant development. However, the mechanisms by which ERF genes regulate the heat stress response are not well understood. Here, we uncover the positive role of ethylene signaling, ERF95 and ERF97 in basal thermotolerance of Arabidopsis thaliana. We demonstrate that ethylene signaling-defective mutants exhibit compromised basal thermotolerance, whereas plants with constitutively activated ethylene response show enhanced basal thermotolerance. EIN3 physically binds to the promoters of ERF95 and ERF97. Ectopic constitutive expression of ERF95 or ERF97 increases the basal thermotolerance of plants. In contrast, erf95 erf96 erf97 erf98 quadruple mutants exhibit decreased basal thermotolerance. ERF95 and ERF97 genetically function downstream of EIN3. ERF95 can physically interact with ERF97, and this interaction is heat inducible. ERF95 and ERF97 regulate a common set of target genes, including known heat-responsive genes and directly bind to the promoter of HSFA2. Thus, our study reveals that the EIN3-ERF95/ERF97-HSFA2 transcriptional cascade may play an important role in the heat stress response, thereby establishing a connection between ethylene and its downstream regulation in basal thermotolerance of plants.

Biochemistry & Molecular Biology↗

Modeling batch melting: Roles of heat transfer and reaction kinetics

Development of mathematical models of heat and mass transfer in glass-melting furnaces began in the 1970s and progressed rapidly with advances in sophisticated experimental/numerical techniques and increasing computational power. Today, practically all newly built or rebuilt furnaces are optimized with these models to meet stringent quality requirements, reduce the unit costs of manufacturing, or control emissions. One remaining hurdle is to model the batch-to-glass conversion accurately enough to reliably assess the glass production rate. This article summarizes two key aspects of the batch-conversion modeling—the heat transfer and the kinetics of conversion—and reviews the current state-of-the-art approaches to simulating them. We critically examine the advantages of the commonly used heat transfer approach, but also explain that its predictive capabilities are significantly restricted by the dependence of batch thermal properties on the time-temperature history. We argue that kinetic approaches to the batch-conversion modeling would offer a significant improvement when coupled with the heat transfer approach. Finally, we summarize key areas requiring further research on the way toward a realistic model of the batch blanket.

Pokorny, Richard↗

Heat Transfer Analysis of a Solid-Solid Heat Recuperation System for Solar-Driven Nonstoichiometric Redox Cycles

Heat transfer is predicted for a solid-solid heat recuperation system employed in a novel directly-irradiated solar thermochemical reactor realizing a metal oxide based nonstoichiometric redox cycle for production of synthesis gas from water and carbon dioxide. The system is designed for continuous operation with heat recuperation from a rotating hollow cylinder of a porous reactive material to a counter-rotating inert solid cylinder via radiative transfer. A transient heat transfer model coupling conduction, convection, and radiation heat transfer predicts temperatures, rates of heat transfer, and the effectiveness of heat recovery. Heat recovery effectiveness of over 50% is attained within a parametric study of geometric and material parameters corresponding to the design of a two-step solar thermochemical reactor.

Lapp, J↗

Surface Temperature Effect on Convective Heat Transfer Coefficients for Jet Impingement Cooling of Electric Machines with Automatic Transmission Fluid: Preprint

In this study, the results of NREL's continued work on experimental characterization of the thermal performance of free-surface jets of automatic transmission fluid impinged on a heated target surface are presented. The measured heat transfer coefficients are useful for understanding factors influencing performance of driveline fluid-based cooling systems for electric machines and help designers in developing high-performance, power-dense and reliable machines. Experiments were carried out for different fluid and target surface temperatures (50 degrees C, 70 degrees C, and 90 degrees C for the fluid and 90 degrees C, 100 degrees C, 110 degrees C, and 120 degrees C for the target surface). Impinging jet velocities (0.5 m/s to 7.5 m/s) and the jet position on the target surface (center versus edge) were also varied. The impinging angle was kept at 90 degrees relative to the target surface. It was found that higher target surface temperature increased heat transfer coefficients, namely, increasing surface temperature from 90 degrees C to 120 degrees C enhanced heat transfer coefficient values at higher impinged jet velocities (7.5 m/s) by up to 15%.

33 ADVANCED PROPULSION SYSTEMS↗

Vertical Structure of Radiative Heating Rates of the MJO during DYNAMO

The vertical structure of radiative heating rates over the region of the tropi-cal Indian Ocean associated with the MJO during the DYNAMO/ARM MJO Investigation Experiment is presented. The mean and variability of heating rates during active, suppressed, and disturbed phases are determined from the Paci?c Northwest National Laboratory combined remote sensing retrieval (CombRet) from Gan Island, Maldives (0.69? S, 73.15? E). TOA and surface ?uxes from the CombRet product are compared with collocated three-hourly CERES SYN1deg Ed4A satellite retrievals. The ?uxes are correlated in time with correlation coef?cients around 0.9, yet CombRet time-mean OLR is 15 W m-2 larger. Previous work has suggested that CombRet under-samples high clouds, due to attenuation by low-level clouds and reduced instrument sensitivity with altitude. However, mean OLR differs between CombRet and CERES for all values of OLR, not just the lowest values corresponding to widespread high clouds. The discrepancy peaks for mid-range OLR, sugges-tive of precipitating, towering cumulus convective clouds, rather than strati-form cirrus clouds. Biases in the cloud-top height of thick clouds substantially contribute to the overestimate of OLR by CombRet. CombRet data is used to generate composite shortwave and longwave atmospheric heating rate pro-?les as a function of the local OLR. Though there is considerable variability in CombRet not directly related to OLR, the time-height structure of mean heating rate composites generated using OLR as the interpolant is broadly representative of tropical convective variability on intraseasonal time scales.

Shell, Karen M.↗