Search NASA⌕ Search

SEARCH · Search NASA

Results for “high performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Directional preparation of cobalt oxide nanoflakes grown on cobalt nanowires as composite cathode for high-performance alkaline batteries

Graphical abstract: Self-supported hierarchical porous CoO@Co core/shell arrays are prepared by combined hydrothermal plus electrodeposition methods and exhibit good electrochemical performances with high capacity & stable cycling life. - Highlights: • Construct self-supported porous CoO@Co core/branch arrays. • Porous CoO@Co composite arrays show high capacity and good cycling life. • Hierarchical porous composite structure is favorable for fast ion/electron transfer. - Abstract: Synthesis of multicomponent core/branch arrays is important for development of advanced energy storage devices. Herein we fabricate porous CoO@Co core/branch arrays by successive hydrothermal + electrodeposition methods CoO nanoflakes branch is uniformly coated on the Co nanowire core forming composite core/branch arrays (CBAs). The CoO@Co CBAs possess combined properties of highly porous structure and strong mechanical stability. As cathode for alkaline batteries, the obtained CoO@Co CBAs exhibit good electrochemical performances with high a capacity of 91.5 mAh g{sup −1} at 1 A g{sup −1} and stable high-rate cycling life (73.5 mAh g{sup −1} after 12,000 cycles at 10 A g{sup −1}). The hierarchical core/branch architecture provides positive roles in the enhancement of electrochemical properties with fast electronic transportation path, and short diffusion channels of ions. Our finding offers a new way to construct high-performance cathode of alkaline batteries.

36 MATERIALS SCIENCE↗

Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes Habitat for Humanity The Woods

The Washington State University (WSU) Energy Program's Building America (BA) team conducted a case study of a high-performance affordable housing community: The Woods (Figure 1). This BA effort is part of a larger-scale study of 30 homes funded from 2013-2016 by Tacoma Public Utilities (TPU) and the Bonneville Power Administration. The Woods is a Habitat for Humanity (HFH) community of homes certified by ENERGY STAR Homes Northwest (ESHNW); the community is in the marine climate of Tacoma/Pierce County, Washington. This research report builds on an earlier preliminary draft 2014 BA report and includes significant billing analysis and cost-effectiveness research from a collaborative and ongoing DHP research effort for TPU and the Bonneville Power Administration. This final BA report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing. The research goal of the U.S. Department of Energy's BA research team Building America Partnership for Improved Residential Construction was to compare a ductless heat pump (DHP) hybrid system (DHP in common area/electric resistance [ER] in bedrooms) to an all-electric zonal ER system in high-performance single-family affordable housing. This effort included assessing the costs and benefits of a DHP/ER hybrid system located in the main living area to offset the primary heating demand of zonal ER heaters in the bedroom zones and comparing these findings to data from of new affordable single-family housing in Washington State. This report includes: (1) Measured indoor and outdoor temperatures and relative humidity (RH) in the homes. (2) Field testing results of heating, ventilating, and air-conditioning equipment; ventilation system airflows; building envelope tightness; lighting, appliance, and other input data required for preliminary Building Energy Optimization (BEopt) modeling; and ENERGY STAR field verification (3) BEopt modeling results compared to measured energy use. (4) A comparison of the space heat energy consumption of a DHP/ER hybrid heating system and a traditional zonal ER heating system installed in the same home. This comparison is made by implementing a series of weekly "flip-flop tests" (referred to here as "switchback" tests per TPU) to compare space heating, temperature, and RH in zonal ER heating mode with a DHP/ER mode as discussed in the Building America Test Plan (Lubliner 2010a). (5) Cost data from HFH and other sources related to building efficiency measures focusing on the DHP/ER hybrid heating system. (6) An evaluation of the thermal performance and cost benefit of DHP/ER hybrid heating systems in these high-performance homes employing life cycle cost analysis for energy code policy and monthly cash flow analysis of HFH homeowners. (7) Post-monitoring occupant survey results. The report also provides the following stakeholder findings and recommendations: (1) DHP single-head systems at The Woods are cost-effective to new homebuyers of these high-performance all-electric homes. (2) Stakeholder education is needed on design, inspection, and commissioning; documentation is needed for heat recovery ventilation (HRV) and from ENERGY STAR builders, verifiers, and inspectors to help ensure that the houses meet the goal of "build tight, ventilate right." (3) A code gap in inspection and enforcement was identified that should be addressed by: (3a) Improving the fire marshal's approach to sprinkler attic piping freeze protection; (3b) Improving the maintenance of ceiling insulation continuity; and (3c) Educating the local building inspector on attic insulation inspection concerns that allow for maximizing design improveme...

affordable housing↗

Embedding sulfur into N-doped carbon nanospheres as enhanced cathode for high-performance lithium-sulfur batteries

Graphical abstract: S has been successfully embedded into N-doped carbon nanospheres as enhanced cathode exhibiting good performance with high specific capacity and cycling stability. - Highlights: • Construct N-doped carbon nanospheres (N-CNSs) are host for sulfur. • N-CNSs/S cathode show high capacity and good cycles. • N doping is favorable for fast ion/electron transfer. - Abstract: Lithium-sulfur (Li-S) batteries are considered as one of the most efficient power candidates owing to high energy density about 7–10 times larger than the commercial cathode materials. However, its practical application is impeded by severe “shuttle effect” and low cycle stability. As a consequence, in this work, we report N-doped carbon nanospheres (N-CNSs) composited with S as cathode for Li-S batteries. The stacked carbon nanosphere structure can not only improve the conductivity of cathode, but also work as barriers to retard diffusion of intermediate polysulfide. Owing to the unique structure, the N-CNSs/S cathode exhibits superior electrochemical performances with high specific capacity (1228 mAh g{sup −1} at 0.1 C), and excellent rate capability as well as good cyclic life. Our smart designed strategy may promote the development of high performance Li-S batteries.

36 MATERIALS SCIENCE↗

XaaS: Acceleration as a Service to Enable Productive High-Performance Cloud Computing

High-performance computing (HPC) and the cloud have evolved independently, specializing their innovations into performance or productivity. Acceleration as a Service (XaaS) is a recipe to empower both fields with a shared execution platform that provides transparent access to computing resources, regardless of the underlying cloud or HPC service provider. Bridging HPC and cloud advancements, XaaS presents a unified architecture built on performance-portable containers. Here, our converged model concentrates on low-overhead, high-performance communication and computing, targeting resource-intensive workloads from climate simulations to machine learning. XaaS lifts the restricted allocation model of Function as a Service (FaaS), allowing users to benefit from the flexibility and efficient resource utilization of serverless computing while supporting long-running and performance-sensitive workloads from HPC.

97 MATHEMATICS AND COMPUTING↗

INL High Performance Building Strategy

High performance buildings, also known as sustainable buildings and green buildings, are resource efficient structures that minimize the impact on the environment by using less energy and water, reduce solid waste and pollutants, and limit the depletion of natural resources while also providing a thermally and visually comfortable working environment that increases productivity for building occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Secure Enclaves: An Isolation-centric Approach for Creating Secure High Performance Computing Environments

High performance computing environments are often used for a wide variety of workloads ranging from simulation, data transformation and analysis, and complex workflows to name just a few. These systems may process data at various security levels but in so doing are often enclaved at the highest security posture. This approach places significant restrictions on the users of the system even when processing data at a lower security level and exposes data at higher levels of confidentiality to a much broader population than otherwise necessary. The traditional approach of isolation, while effective in establishing security enclaves poses significant challenges for the use of shared infrastructure in HPC environments. This report details current state-of-the-art in virtualization, reconfigurable network enclaving via Software Defined Networking (SDN), and storage architectures and bridging techniques for creating secure enclaves in HPC environments.

97 MATHEMATICS AND COMPUTING↗

A Case Study on Neural Inspired Dynamic Memory Management Strategies for High Performance Computing.

As high performance computing architectures pursue more computational power there is a need for increased memory capacity and bandwidth as well. A multi-level memory (MLM) architecture addresses this need by combining multiple memory types with different characteristics as varying levels of the same architecture. How to efficiently utilize this memory infrastructure is an unknown challenge, and in this research we sought to investigate whether neural inspired approaches can meaningfully help with memory management. In particular we explored neurogenesis inspired re- source allocation, and were able to show a neural inspired mixed controller policy can beneficially impact how MLM architectures utilize memory.

97 MATHEMATICS AND COMPUTING↗

Detecting Data-Races in High-Performance Computing

High-performance computing is susceptible to data-race bugs. Data races occur when sequences of computed events do not happen in the intended order, a significant barrier to the integrity of parallel programs using shared-memory architectures. Many approaches to data-race detection are based on traditional static-analysis techniques that typically execute on a program’s source code or control-flow graph (the graphical representation of all possible orders of events in the execution of a program). Similar to classical data-flow analyses, such tools can produce false alarms that report spurious race conditions on error free programs. We have developed a software verification technique that requires as input only a program’s source code and can automatically detect a data-race bug which definitely exists, determine that a program is definitely data-race free, or report that it cannot determine either of the two cases.

97 MATHEMATICS AND COMPUTING↗

Optimization of Ventilation Energy Demands and Indoor Air Quality in High-Performance Homes

High-performance homes require that ventilation energy demands and indoor air quality (IAQ) be simultaneously optimized. We attempted to bridge these two areas by conducting tests in a research house located in Oak Ridge, TN, that was 20 months old, energy-efficient (i.e., expected to consume 50% less energy than a house built per the 2006 IRC), tightly-built (i.e., natural ventilation rate ~0.02 h-1), unoccupied, and unfurnished. We identified air pollutants of concern in the test home that could generally serve as indicators of IAQ, and conduced field experiments and computer simulations to determine the effectiveness and energy required by various techniques that lessened the concentration of these contaminants. Formaldehyde was selected as the main pollutant of concern among the contaminants that were sampled in the initial survey because it was the only compound that showed concentrations that were greater than the recommended exposure levels. Field data indicate that concentrations were higher during the summer primarily because emissions from sources rise with increases in temperature. Furthermore, supply ventilation and gas-phase filtration were effective means to reduce formaldehyde concentrations; however, exhaust ventilation had minimal influence on this pollutant. Results from simulations suggest that formaldehyde concentrations obtained while ventilating per ASHRAE 62.2-2010 could be decreased by about 20% from May through September through three strategies: 1) increasing ASHRAE supply ventilation by a factor of two, 2) reducing the thermostat setpoint from 76 to 74 F, or 3) running a gas-phase filtration system while decreasing supply ventilation per ASHRAE by half. In the mixed-humid climate of Oak Ridge, these strategies caused increases in electricity cost of ~$5 to ~$15/month depending on outdoor conditions.

Hun, Diana E↗

FPGA Based High Performance Computing

Current high performance computing (HPC) applications are found in many consumer, industrial and research fields. From web searches to auto crash simulations to weather predictions, these applications require large amounts of power by the compute farms and supercomputers required to run them. The demand for more and faster computation continues to increase along with an even sharper increase in the cost of the power required to operate and cool these installations. The ability of standard processor based systems to address these needs has declined in both speed of computation and in power consumption over the past few years. This paper presents a new method of computation based upon programmable logic as represented by Field Programmable Gate Arrays (FPGAs) that addresses these needs in a manner requiring only minimal changes to the current software design environment.

42 ENGINEERING↗

Cobalt-substituted SrTi 0.3 Fe 0.7 O 3–δ : a stable high-performance oxygen electrode material for intermediate-temperature solid oxide electrochemical cells

A key need in the development of solid oxide cells (SOCs) is for electrodes that promote fast oxygen reduction and oxygen evolution reactions at reduced operating temperature (≤700 °C), with sufficient durability to allow operation over desired 40 000 h lifetimes. A wide range of electrode materials have been investigated, with some providing resistance low enough for cell operation below 700 °C, but it is generally found that the electrode performance degrades over time. Here we demonstrate an oxygen electrode material, Sr(Ti 0.3 Fe 0.7–x Co x )O 3–δ (STFC), that provides a unique combination of excellent oxygen electrode performance and long-term stability. The addition of a relatively small amount of Co to Sr(Ti 0.3 Fe 0.7 )O 3–δ , e.g., x = 0.07, reduces the electrode polarization resistance by >2 times. The STFC electrode yields stable performance in both fuel cell and electrolysis modes at 1 A cm –2 . The fundamental oxygen diffusion and surface exchange coefficients of STFC are determined, and shown to be substantially better than those of La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3–δ , the most widely used SOC oxygen electrode material. Here, while other electrode materials have been shown to exhibit better oxygen transport coefficients than STFC, they do not match its stability.

25 ENERGY STORAGE↗