Search NASA⌕ Search

SEARCH · Search NASA

Results for “hydrogen detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Infrared spectroscopy of the dwarf starburst galaxy Henize 2-10

Researchers present 1.2 to 2.2 micron spectra of the nucleus of Henize 2 to 10, taken at United Kingdom Infrared Telescope (UKIRT) with the cool grating spectrometer 2 (CGS 2). This galaxy displays strong line emission from interstellar H (+) (1.282 and 2.166 microns) and (Fe (+)) (1.256 and 1.644 microns), in common with other star-forming galaxy nuclei. However, the 1 to 0 S(1) line of molecular hydrogen at 2.122 micron is not detected - the upper limit of 0.15 (3 sigma) for the value of the flux ratio I sub 1-os(1)/I sub Br gamma is much lower than the typical values of 0.4 to 0.9 measured in a sample of 28 non-interacting starburst galaxies. From the Pa beta/Br gamma line ratio researchers derive a total extinction of A sub v approx. 4 mag. The de-reddened H (+) and (Fe (+) line fluxes are used to estimate the total ionizing luminosity and the average supernova rate in the central 150 pc of He 2 to 10. By comparison of these estimates with existing Infrared Astronomy Satellite (IRAS) and radio continuum data, researchers are able to set limits on the range of stellar masses present in this unevolved (less than 10(exp 7) year old) starburst nucleus. Possible reasons for the low H2/H+ line ratios observed in young starburst systems (He 2 to 10, NGC 7714, IIZw40; e.g., Moorwood and Oliva 1988) are briefly discussed.

Blanco, P. R.↗

Determining large-scale heliospheric structure using ultraviolet resonance line observations

Currently the Pioneer 10 and Voyager 1 and 2 spacecraft are beyond the orbit of Pluto, traveling outward from the Sun. Each is capable of detecting ultraviolet radiation resonantly scattered from hydrogen and helium atoms in the heliosphere and local interstellar medium. These observations are particularly well suited for the investigation of the large-scale heliospheric H and He distributions because the Voyager spacecraft are heading upstream, into the direction of local interstellar flow, whereas Pioneer 10 is heading downstream. Observations of the brightest resonance line, H Lyman-alpha, reveals that beyond about 20 AU from the Sun, upstream intensities decrease less quickly as a function of solar distance than downstream intensities. This implies that the heliospheric H distributions in the upstream and downstream directions are significantly different. Heliospheric H atoms originate in the local interstellar flow, and must penetrate through the heliospheric interface, where they are subject to charge exchange collisions with solar wind and interstellar protons. Models indicate that this process is probably responsible for the upstream/downstream difference in H Lyman-alpha. In addition, a recent spectroscopic determination of the H atom velocity distribution in the inner heliosphere implies a significant deceleration in the bulk flow speed of the heliospheric hydrogen gas relative to the helium flow, an effect that is also likely due to H-p charge exchange occurring in the upstream heliospheric interface region. In this presentation, recent heliospheric resonance line observations and their interpretations will be reviewed, focusing on their sensitivity to large-scale heliospheric structure.

Hall, Doyle T.↗

A Quadrupole Ion Trap Mass Spectrometer for Quantitative Analysis of Nitrogen-Purged Compartments within the Space Shuttle

To enter orbit the Space Shuttle burns 1.8 million liters of liquid hydrogen combined with 0.8 million liters of liquid oxygen through three rocket engines mounted in the aft. NASA monitors the nitrogen-purged aft compartment for increased levels of hydrogen or oxygen in order to detect and determine the severity of a cryogenic fuel leak. Current monitoring is accomplished with a group of mass spectrometer systems located as much as 400 feet away from the shuttle. It can take up to 45 seconds for gas to reach the mass spectrometer, which precludes monitoring for leaks in the final moments before liftoff (the orbiter engines are started at T-00:06 seconds). To remedy the situation, NASA is developing a small rugged mass spectrometer to be used as point-sources around the Space Shuttle.

Ottens, Andrew K.↗

High Resolution Spectroscopy of X-ray Quasars: Searching for the X-ray Absorption from the Warm-Hot Intergalactic Medium

We present a survey of six low to moderate redshift quasars with Chandra and XMM-Newton. The primary goal is to search for the narrow X-ray absorption lines produced by highly ionized metals in the Warm-Hot Intergalactic Medium. All the X-ray spectra can be well fitted by a power law with neutral hydrogen absorption. Only one feature is detected at above 3-sigma level in all the spectra, which is consistent with statistic fluctuation. We discuss the implications in our understanding of the baryon content of the universe. We also discuss the implication of the non-detection of the local (z approx. 0) X-ray absorption.

Fang, Taotao↗

Fault Detection, Isolation and Recovery (FDIR) Portable Liquid Oxygen Hardware Demonstrator

The Fault Detection, Isolation and Recovery (FDIR) hardware demonstration will highlight the effort being conducted by Constellation's Ground Operations (GO) to provide the Launch Control System (LCS) with system-level health management during vehicle processing and countdown activities. A proof-of-concept demonstration of the FDIR prototype established the capability of the software to provide real-time fault detection and isolation using generated Liquid Hydrogen data. The FDIR portable testbed unit (presented here) aims to enhance FDIR by providing a dynamic simulation of Constellation subsystems that feed the FDIR software live data based on Liquid Oxygen system properties. The LO2 cryogenic ground system has key properties that are analogous to the properties of an electronic circuit. The LO2 system is modeled using electrical components and an equivalent circuit is designed on a printed circuit board to simulate the live data. The portable testbed is also be equipped with data acquisition and communication hardware to relay the measurements to the FDIR application running on a PC. This portable testbed is an ideal capability to perform FDIR software testing, troubleshooting, training among others.

Oostdyk, Rebecca L.↗

Chemochromic detector for sensing gas leakage and process for producing the same

A chemochromic sensor for detecting a combustible gas, such as hydrogen, includes a chemochromic pigment mechanically mixed with a polymer and formed into a rigid or pliable material. In a preferred embodiment, the chemochromic detector includes aerogel material. The detector is robust and easily modifiable for a variety of applications and environmental conditions, such as atmospheres of inert gas, hydrogen gas, or mixtures of gases, or in environments that have variable temperature, including high temperatures such as above 100.degree. C. and low temperatures such as below -196.degree. C.

Roberson, Luke B.↗

Chemochromic Detector for Sensing Gas Leakage and Process for Producing the Same

A chemochromic sensor for detecting a combustible gas, such as hydrogen, includes a chemochromic pigment mechanically mixed with a polymer and molded into a rigid or pliable shape. In a preferred embodiment, the chemochromic detector is within the material which is molded into a manufactured part, said part becoming the detector itself. The detector is robust and easily modifiable for a variety of applications and environmental conditions, such as atmospheres of inert gas, hydrogen gas, or mixtures of gases, or in environments that have variable temperature, including high temperatures such as above 100 C. and low temperatures such as below -196 C.

Roberson, Luke B.↗

Chemochromic Detector for Sensing Gas Leakage and Process for Producing the Same

A chemochromic sensor for detecting a combustible gas, such as hydrogen, includes a chemochromic pigment and a textile polymer. The textile material includes a chemochromic pigment operably responsive to a combustible gas. The combustible gas sensing textile material can be made by melt spinning, solution spinning, or other similar techniques. In a preferred embodiment carbon nanotubes are used with the textile material which will increase the material strength and alter the thermal and/or electrical properties. These textiles woven into fabrics can provide garments not only with hydrogen sensing capabilities but the carbon nanotubes will allow for a range of sensing capabilities to be embedded (i.e. gas, health, and electronic monitors) within the garments.

Roberson, Luke B.↗

Characterization of a turbomolecular-pumped magnetic sector mass spectrometer

A Perkin Elmer MGA-1200, turbomolecular-pumped, magnetic sector, multiple gas analyzer mass spectrometer with modified inlet for fast response was characterized for the analysis of hydrogen, helium, oxygen and argon in nitrogen and helium background gases. This instrument was specially modified for the Vanderberg AFB SLC-6 Hydrogen Disposal Test Program, as a part of the Hydrogen Sampling System (H2S2). Linearity, precision, drift, detection limits and accuracy among other analytical parameters for each of the background gas were studied to evaluate the performance of the instrument. The result demonstrates that H2S2 mass spectrometer is a stable instrument and can be utilized for the quantitative analytical determination of hydrogen, helium, oxygen and argon in nitrogen and helium background gases.

Mehta, Narinder K.↗

Chemochromic Hydrogen Sensors

As fossil fuel supplies decline, hydrogen is quickly becoming an increasingly important fuel source. Currently hydrogen is the prime fuel of today's space vehicles (e.g., Space Shuttle) and featured as a fuel for some prototype vehicles such as the BMW seven series model. Hydrogen is a colorless, odorless gas with a 4% lower explosive limit which makes leak detection a priority. In an effort to support the use of hydrogen, a chemochromic (color changing) sensor was developed that is robust, simple to use, and does not require active operation. It can be made into a thin tape which can be conveniently used for leak detection at flanges, valves, or outlets. Chemochromic sensors can be either reversible or irreversible; however, irreversible chemochromic sensors will be analyzed in this report. The irreversible sensor is useful during hazardous operations when personnel cannot be present. To actively monitor leaks, testing of the irreversible sensor against environmental effects was completed and results indicated this material is suitable for outdoor use in the harsh beachside environment of Kennedy Space Center. The experiments in this report will give additional results to the environmental testing by adding solid rocket booster residue as a variable. The primary motivation for these experiments is to prepare the sensors for the launch pad environment at the Kennedy Space Center. In an effort to simulate the atmosphere at the pads before and after launch, the chemochromic sensors are exposed to solid rocket residue under various conditions.

Wiggins, Bryan C.↗

Hydrogenation of interstellar molecules: a survey for methylenimine (CH2NH)

Methylenimine (CH2NH) has been convincingly detected for the first time outside the Galactic center as part of a study of the hydrogenation of interstellar molecules. We have observed transitions from energy levels up to about 100 K above the ground state in the giant molecular clouds W51, Orion KL and G34.3 + 0.15. In addition, CH2NH was found at the " radical-ion peak" on the quiescent ridge of material in the Orion molecular cloud. The abundance ratio CH2NH/HCN at the radical-ion peak agrees with the predictions of recent gas-phase chemical models. This ratio is an order of magnitude higher in the warmer cloud cores, suggesting additional production pathways for CH2NH, probably on interstellar grains.

Non-NASA Center↗

Metallic Hydrogen - Potentially a High Energy Rocket Propellant

Pure metallic hydrogen is predicted to have a specific impulse (Isp) of 1700 seconds, but the reaction temperature is too high for current engine materials. Diluting metallic hydrogen with liquid hydrogen can reduce the reaction temperature to levels compatible with current material limits and still provide an Isp greater than 900 s. Metallic hydrogen has not yet been produced on earth, but experimental techniques exist that may change this situation. This paper will provide a brief description of metallic hydrogen and the status of experiments that may soon produce detectable quantities of this material in the lab. Also provided are some characteristics for diluted metallic hydrogen engines and launch vehicles.

Cole, John↗

A CFD Analysis of Hydrogen Leakage During On-Pad Purge in the ORION/ARES I Shared Volume

A common open volume is created by the stacking of the Orion vehicle onto the Ares I Upper Stage. Called the Shared Volume, both vehicles contribute to its gas, fluid, and thermal environment. One of these environments is related to hazardous hydrogen gas. While both vehicles use inert purge gas to mitigate any hazardous gas buildup, there are concerns that hydrogen gas may still accumulate and that the Ares I Hazardous Gas Detection System will not be sufficient for monitoring the integrated volume. This Computational Fluid Dynamics (CFD) analysis has been performed to examine these topics. Results of the analysis conclude that the Ares I Hazardous Gas Detection System will be able to sample the vent effluent containing the highest hydrogen concentrations. A second conclusion is that hydrogen does not accumulate under the Orion Service Module (SM) avionics ring as diffusion and purge flow mixing sufficiently dilute the hydrogen to safe concentrations. Finally the hydrogen concentrations within the Orion SM engine nozzle may slightly exceed the 1 percent volume fraction when the entire worse case maximum full leak is directed vertically into the engine nozzle.

Ajmani, Kumud↗

Aircraft-borne, laser-induced fluorescence instrument for the in situ detection of hydroxyl and hydroperoxyl radicals

The odd-hydrogen radicals OH and HO2 are central to most of the gas-phase chemical transformations that occur in the atmosphere. Of particular interest is the role that these species play in controlling the concentration of stratospheric ozone. This paper describes an instrument that measures both of these species at volume mixing ratios below one part in 10(exp 14) in the upper troposphere and lower stratosphere. The hydroxyl radical (OH) is measured by laser induced fluorescence at 309 nm. Tunable UV light is used to pump OH to the first electric state near 282 nm. the laser light is produced by a high-repetition rate pulsed dye-laser powered with all solid-state pump lasers. HO2 is measured as OH after gas-phase titration with nitric oxide. Measurements aboard a NASA ER-2 aircraft demonstrate the capability of this instrument to perform reliably with very high signal-to-noise ratios (greater than 30) achieved in short integration times (less than 20 sec).

Wennberg, P. O.↗

Hydrogen storage in Earth's mantle and core

Two different approaches to explaining how hydrogen might be stored in the mantle are illustrated by a number of papers published over the past 25-30 years, but there has been little attempt to provide objective comparisons of the two. One approach invokes the presence in the mantle of dense hydrous magnesium silicates (DHMS) stable at elevated pressures and temperatures. The other involves nominally anhydrous minerals (NAM) that contain hydrogen as a minor constituent on the ppm level. Experimental studies on DHMS indicate these phases may be stable to pressures and temperatures as high at 16 GPa and 1200 C. This temperature is lower than that indicated by a mantle geotherm at 16 GPa, but may be reasonable for a subducting slab. It is possible that other DHMS could be stable to even higher pressures, but little is known about maximum temperature limits. For NAM, small amounts of hydrogen (up to several hundred ppm) have been detected in olivine, orthopyroxene, clinopyroxene, and garnet recovered from xenoliths in kimberlites, eclogites, and alkali basalts; it has been demonstrated that synthetic wadsleyite and perovskite can accommodate significant amounts of hydrogen. A number of problems are associated with each possibility. For NAM originating in the mantle, one would like to assume that the hydrogen measured in samples recovered on Earth's surface was incorporated when the phase-crystallized at high temperatures and pressures, but it could have been introduced during transport to the surface. Major problems for the DHMS proponents are that none of these phases have been found as minerals and little is yet known about their stabilities in systems containing other cations such as Fe, Al, and Ca.

Prewitt, Charles T.↗

An alpha particle instrument with alpha, proton, and X-ray modes for planetary chemical analyses

The interaction of alpha particles with matter is employed in a compact instrument that could provide rather complete in-situ chemical analyses of surfaces and thin atmospheres of extraterrestrial bodies. The instrument is a miniaturized and improved version of the Surveyor lunar instrument. The backscattering of alpha particles and (alpha, p) reactions provide analytical data on the light elements (carbon-iron). An X-ray mode that detects the photons produced by the alpha sources provides sensitivity and resolution for the chemical elements heavier than about silicon. The X-rays are detected by semiconductor detectors having a resolution between 150 and 250 eV at 5.9 keV. Such an instrument can identify and determine with good accuracy 99 percent of the atoms (except hydrogen) in rocks. For many trace elements, the detecting sensitivity is a few ppm. Auxiliary sources could be used to enhance the sensitivities for elements of special interest. The instrument could probably withstand the acceleration involved in semi-hard landings.

Economou, T. E.↗

Can SOHO SWAN detect CMEs?

We have investigated the possibility that the Solar Wind Anisotropies (SWAN) remote sensing instrument on SOHO may be able to detect coronal mass ejections (CMEs) in neutral Hydrogen Lyman-? emission. We have identified CMEs near the Sun in observations by the SOHO LASCO white-light coronagraphs and in extreme ultraviolet emissions using SOHO E n . There are very few methods of tracking CMEs after they leave the coronagraph's field-of-view, so this is an important topic to study. The primary science goal of the SWAN investigation is the measurement of large-scale structures in the solar wind, and these are obtained by detecting intensity fluctuations in Lyman-?. SWAN consists of a pair of Sensors on opposite panels of SOHO. The instantaneous field-of-view of each sensor unit is a So x So square, divided into lo pixels. A gimbaled periscope system allows each sensor to map the intensity distribution of Lyman-?, and the entire sky can be scanned in less than one day. This is the typical mode of operation for this instrument.

St.Cyr, O. C.↗

Portable Microleak-Detection System

The figure schematically depicts a portable microleak-detection system that has been built especially for use in testing hydrogen tanks made of polymer-matrix composite materials. (As used here, microleak signifies a leak that is too small to be detectable by the simple soap-bubble technique.) The system can also be used to test for microleaks in tanks that are made of other materials and that contain gases other than hydrogen. Results of calibration tests have shown that measurement errors are less than 10 percent for leak rates ranging from 0.3 to 200 cm3/min. Like some other microleak-detection systems, this system includes a vacuum pump and associated plumbing for sampling the leaking gas, and a mass spectrometer for analyzing the molecular constituents of the gas. The system includes a flexible vacuum chamber that can be attached to the outer surface of a tank or other object of interest that is to be tested for leakage (hereafter denoted, simply, the test object). The gas used in a test can be the gas or vapor (e.g., hydrogen in the original application) to be contained by the test object. Alternatively, following common practice in leak testing, helium can be used as a test gas. In either case, the mass spectrometer can be used to verify that the gas measured by the system is the test gas rather than a different gas and, hence, that the leak is indeed from the test object.

Rivers, H. Kevin↗