Search NASA⌕ Search

SEARCH · Search NASA

Results for “image quality structure material”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

X-ray imaging performance of scintillator-filled silicon pore arrays

The need for fine detail visibility in various applications such as dental imaging, mammography, but also neurology and cardiology, is the driver for intensive efforts in the development of new x-ray detectors. The spatial resolution of current scintillator layers is limited by optical diffusion. This limitation can be overcome by a pixelation, which prevents optical photons from crossing the interface between two neighboring pixels. In this work, an array of pores was etched in a silicon wafer with a pixel pitch of 50 {mu}m. A very high aspect ratio was achieved with wall thicknesses of 4-7 {mu}m and pore depths of about 400 {mu}m. Subsequently, the pores were filled with Tl-doped cesium iodide (CsI:Tl) as a scintillator in a special process, which includes powder melting and solidification of the CsI. From the sample geometry and x-ray absorption measurement the pore fill grade was determined to be 75%. The scintillator-filled samples have a circular active area of 16 mm diameter. They are coupled with an optical sensor binned to the same pixel pitch in order to measure the x-ray imaging performance. The x-ray sensitivity, i.e., the light output per absorbed x-ray dose, is found to be only 2.5%-4.5% of a commercial CsI-layer of similar thickness, thus very low. The efficiency of the pores to transport the generated light to the photodiode is estimated to be in the best case 6.5%. The modulation transfer function is 40% at 4 lp/mm and 10%-20% at 8 lp/mm. It is limited most likely by the optical gap between scintillator and sensor and by K-escape quanta. The detective quantum efficiency (DQE) is determined at different beam qualities and dose settings. The maximum DQE(0) is 0.28, while the x-ray absorption with the given thickness and fill factor is 0.57. High Swank noise is suspected to be the reason, mainly caused by optical scatter inside the CsI-filled pores. The results are compared to Monte Carlo simulations of the photon transport inside the pore array structure. In addition, some x-ray images of technical and anatomical phantoms are shown. This work shows that scintillator-filled pore arrays can provide x-ray imaging with high spatial resolution, but are not suitable in their current state for most of the applications in medical imaging, where increasing the x-ray doses cannot be tolerated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Noise Reduction in Low-Dose X-Ray Fluoroscopy for Image-Guided Radiation Therapy

Purpose: To improve the quality of low-dose X-ray fluoroscopic images using statistics-based restoration algorithm so that the patient fluoroscopy can be performed with reduced radiation dose. Method and Materials: Noise in the low-dose fluoroscopy was suppressed by temporal and spatial filtering. The temporal correlation among neighboring frames was considered by the Karhunen-Loeve (KL) transform (i.e., principal component analysis). After the KL transform, the selected neighboring frames of fluoroscopy were decomposed to uncorrelated and ordered principal components. For each KL component, a penalized weighted least-squares (PWLS) objective function was constructed to restore the ideal image. The penalty was chosen as anisotropic quadratic, and the penalty parameter in each KL component was inversely proportional to its corresponding eigenvalue. Smaller KL eigenvalue is associated with the KL component of lower signal-to-noise ratio (SNR), and a larger penalty parameter should be used for such KL component. The low-dose fluoroscopic images were acquired using a Varian Acuity simulator. A quality assurance phantom and an anthropomorphic chest phantom were used to evaluate the presented algorithm. Results: In the images restored by the proposed KL domain PWLS algorithm, noise is greatly suppressed, whereas fine structures are well preserved. Average improvement rate of SNR is 75% among selected regions of interest. Comparison studies with traditional techniques, such as the mean and median filters, show that the proposed algorithm is advantageous in terms of structure preservation. Conclusions: The proposed noise reduction algorithm can significantly improve the quality of low-dose X-ray fluoroscopic image and allows for dose reduction in X-ray fluoroscopy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Crystal Growth of II-VI Semiconducting Alloys by Directional Solidification

This research study is investigating the effects of a microgravity environment during the crystal growth of selected II-VI semiconducting alloys on their compositional, metallurgical, electrical and optical properties. The on-going work includes both Bridgman-Stockbarger and solvent growth methods, as well as growth in a magnetic field. The materials investigated are II-VI, Hg(1-x)Zn(x)Te, and Hg(1-x)Zn(x)Se, where x is between 0 and 1 inclusive, with particular emphasis on x-values appropriate for infrared detection and imaging in the 5 to 30 micron wavelength region. Wide separation between the liquidus and solidus of the phase diagrams with consequent segregation during solidification and problems associated with the high volatility of one of the components (Hg), make the preparation of homogeneous, high-quality, bulk crystals of the alloys an extremely difficult nearly an impossible task in a gravitational environment. The three-fold objectives of the on-going investigation are as follows: (1) To determine the relative contributions of gravitationally-driven fluid flows to the compositional redistribution observed during the unidirectional crystal growth of selected semiconducting solid solution alloys having large separation between the liquidus and solidus of the constitutional phase diagram; (2) To ascertain the potential role of irregular fluid flows and hydrostatic pressure effects in generation of extended crystal defects and second-phase inclusions in the crystals; and, (3) To obtain a limited amount of "high quality" materials needed for bulk crystal property characterizations and for the fabrication of various device structures needed to establish ultimate material performance limits. The flight portion of the study was to be accomplished by performing growth experiments using the Crystal Growth Furnace (CGF) manifested to fly on various Spacelab missions.

Lehoczky, Sandor L.↗

Low-dose x-ray tomography through a deep convolutional neural network

Synchrotron-based X-ray tomography offers the potential of rapid large-scale reconstructions of the interiors of materials and biological tissue at fine resolution. However, for radiation sensitive samples, there remain fundamental trade-offs between damaging samples during longer acquisition times and reducing signals with shorter acquisition times. We present a deep convolutional neural network (CNN) method that increases the acquired X-ray tomographic signal by at least a factor of 10 during low-dose fast acquisition by improving the quality of recorded projections. Short exposure time projections enhanced with CNN show similar signal to noise ratios as compared with long exposure time projections and much lower noise and more structural information than low-dose fats acquisition without CNN. We optimized this approach using simulated samples and further validated on experimental nano-computed tomography data of radiation sensitive mouse brains acquired with a transmission X-ray microscopy. We demonstrate that automated algorithms can reliably trace brain structures in datasets collected with low dose-CNN. As a result, this method can be applied to other tomographic or scanning based X-ray imaging techniques and has great potential for studying faster dynamics in specimens.

60 APPLIED LIFE SCIENCES↗

Information-theoretic discrepancy based iterative reconstructions (IDIR) for polychromatic x-ray tomography

Purpose: X-ray photons generated from a typical x-ray source for clinical applications exhibit a broad range of wavelengths, and the interactions between individual particles and biological substances depend on particles' energy levels. Most existing reconstruction methods for transmission tomography, however, neglect this polychromatic nature of measurements and rely on the monochromatic approximation. In this study, we developed a new family of iterative methods that incorporates the exact polychromatic model into tomographic image recovery, which improves the accuracy and quality of reconstruction.Methods: The generalized information-theoretic discrepancy (GID) was employed as a new metric for quantifying the distance between the measured and synthetic data. By using special features of the GID, the objective function for polychromatic reconstruction which contains a double integral over the wavelength and the trajectory of incident x-rays was simplified to a paraboloidal form without using the monochromatic approximation. More specifically, the original GID was replaced with a surrogate function with two auxiliary, energy-dependent variables. Subsequently, the alternating minimization technique was applied to solve the double minimization problem. Based on the optimization transfer principle, the objective function was further simplified to the paraboloidal equation, which leads to a closed-form update formula. Numerical experiments on the beam-hardening correction and material-selective reconstruction were conducted to compare and assess the performance of conventional methods and the proposed algorithms.Results: The authors found that the GID determines the distance between its two arguments in a flexible manner. In this study, three groups of GIDs with distinct data representations were considered. The authors demonstrated that one type of GIDs that comprises “raw” data can be viewed as an extension of existing statistical reconstructions; under a particular condition, the GID is equivalent to the Poisson log-likelihood function. The newly proposed GIDs of the other two categories consist of log-transformed measurements, which have the advantage of imposing linearized penalties over multiple discrepancies. For all proposed variants of the GID, the aforementioned strategy was used to obtain a closed-form update equation. Even though it is based on the exact polychromatic model, the derived algorithm bears a structural resemblance to conventional methods based on the monochromatic approximation. The authors named the proposed approach as information-theoretic discrepancy based iterative reconstructions (IDIR). In numerical experiments, IDIR with raw data converged faster than previously known statistical reconstruction methods. IDIR with log-transformed data exhibited superior reconstruction quality and faster convergence speed compared with conventional methods and their variants.Conclusions: The authors' new framework for tomographic reconstruction allows iterative inversion of the polychromatic data model. The primary departure from the traditional iterative reconstruction was the employment of the GID as a new metric for quantifying the inconsistency between the measured and synthetic data. The proposed methods outperformed not only conventional methods based on the monochromatic approximation but also those based on the polychromatic model. The authors have observed that the GID is a very flexible means to design an objective function for iterative reconstructions. Hence, the authors expect that the proposed IDIR framework will also be applicable to other challenging tasks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Joint iterative reconstruction and 3D rigid alignment for X-ray tomography

X-ray tomography is widely used for three-dimensional structure determination in many areas of science, from the millimeter to the nanometer scale. The resolution and quality of the 3D reconstruction is limited by the availability of alignment parameters that correct for the mechanical shifts of the sample or sample stage for the images that constitute a scan. In this paper we describe an algorithm for marker-free, fully automated and accurately aligned and reconstructed X-ray tomography data. Our approach solves the tomographic reconstruction jointly with projection data alignment based on a rigid-body deformation model. We demonstrate the robustness of our method on both synthetic phantom and experimental data and show that our method is highly efficient in recovering relatively large alignment errors without prior knowledge of a low resolution approximation of the 3D structure or a reasonable estimate of alignment parameters.

36 MATERIALS SCIENCE↗

Dielectric resonator method for determining gap symmetry of superconductors through anisotropic nonlinear Meissner effect

We present a new measurement method which can be used to image the gap nodal structure of superconductors whose pairing symmetry is under debate. This technique utilizes a high quality factor microwave resonance involving the sample of interest. While supporting a circularly symmetric standing wave current pattern, the sample is perturbed by a scanned laser beam, creating a photoresponse that was previously shown to reveal the superconducting gap anisotropy. Simulation and the measurement of the photoresponse of an unpatterned Nb film show less than 8% anisotropy, as expected for a superconductor with a nearly isotropic energy gap along with expected systematic uncertainty. On the other hand, measurement of a YBa 2 Cu 3 O 7- δ thin film shows a clear 4-fold symmetric image with ~12.5% anisotropy, indicating the well-known 4-fold symmetric d x 2 - y 2 gap nodal structure in the ab -plane. The deduced gap nodal structure can be further cross-checked by low temperature surface impedance data, which are simultaneously measured. The important advantage of the presented method over the previous spiral resonator method is that it does not require a complicated lithographic patterning process which limits one from testing various kinds of materials due to photoresponse arising from patterning defects. This advantage of the presented technique, and the ability to measure unpatterned samples such as planar thin films and single crystals, enables one to survey the pairing symmetry of a wide variety of unconventional superconductors.

47 OTHER INSTRUMENTATION↗

AlGaN/GaN High Electron Mobility Transistor Grown and Fabricated on ZrTi Metallic Alloy Buffer Layers

AlGaN/GaN high electron mobility transistors (HEMTs) were demonstrated for structures grown on ZrTi metallic alloy buffer layers, which provided lattice matching of the in-plane lattice parameter (“a-parameter”) to hexagonal GaN. The quality of the GaN buffer layer and HEMT structure were confirmed with X-ray 2θ and rocking scans as well as cross-section transmission electron microscopy (TEM) images. The X-ray 2θ scans showed full widths at half maximum (FWHM) of 0.06°, 0.05° and 0.08° for ZrTi alloy, GaN buffer layer, and the entire HEMT structure, respectively. TEM of the lower section of the HEMT structure containing the GaN buffer layer and the AlN/ZrTi/AlN stack on the Si substrate showed that it was important to grow AlN on the top of ZrTi prior to growing the GaN buffer layer. Finally, the estimated threading dislocation (TD) density in the GaN channel layer of the HEMT structure was in the 10 8 cm -2 range.

36 MATERIALS SCIENCE↗

Effects of Co layer thickness and annealing temperature on the magnetic properties of inverted [Pt/Co] multilayers

The effects of Co layer thickness and annealing temperature on the perpendicular magnetic anisotropy (PMA) properties of inverted [Pt (0.2 nm)/Co (t{sub Co})]{sub 6} multilayers (where t{sub Co} indicates the thickness of the Co layer) have been investigated. The cross-sectional microstructure, as observed from the high-resolution transmission electron microscope images, shows a clear layered structure with atomically flat interfaces both in the as-deposited state as well as after annealing, indicating the interface effects for PMA. The effective PMA energy density (K{sub eff}) increases significantly with an increase in t{sub Co} from 0.2 to 0.28 nm and then becomes almost saturated with further increases in t{sub Co}, followed by a slight reduction at the highest Co thickness, t{sub Co} = 0.6 nm. In order to explain the t{sub Co} dependence on K{sub eff}, the intrinsic PMA energy density (K{sub i}) is calculated by additionally measuring a similar set of results for the saturation magnetization. The K{sub i} value increases nearly linearly with the increase in t{sub Co} from 0.2 to 0.5 nm, followed by saturation at a higher t{sub Co} value of 0.6 nm. Owing to a close relationship between K{sub i} and the quality of the interfaces, these results indicate a similar t{sub Co} dependence on the quality of the interfaces. This is further supported from the magnetic measurements of the samples annealed at the highest temperature of 500 °C, where a second phase is formed, which show a similar t{sub Co} dependence on the amount of the second phase. The K{sub i} value is nearly independent of the annealing temperature at t{sub Co} ≤ 0.4 nm, above which a substantial reduction is observed, when the annealing temperature exceeds 500 °C.

36 MATERIALS SCIENCE↗

MultiTaskDeltaNet: change detection-based image segmentation for operando ETEM with application to carbon gasification kinetics

Transforming in situ transmission electron microscopy (TEM) imaging into a tool for spatially-resolved operando characterization of solid-state reactions requires automated, high-precision semantic segmentation of dynamically evolving features. However, traditional deep learning methods for semantic segmentation often face limitations due to the scarcity of labeled data, visually ambiguous features of interest, and scenarios involving small objects. To tackle these challenges, we introduce MultiTaskDeltaNet (MTDN), a novel deep learning architecture that creatively reconceptualizes the segmentation task as a change detection problem. By implementing a unique Siamese network with a U-Net backbone and using paired images to capture feature changes, MTDN effectively leverages minimal data to produce high-quality segmentations. Furthermore, MTDN utilizes a multi-task learning strategy to exploit correlations between physical features of interest. In an evaluation using data from in situ environmental TEM (ETEM) videos of filamentous carbon gasification, MTDN demonstrated a significant advantage over conventional segmentation models, particularly in accurately delineating fine structural features. Notably, MTDN achieved a 10.22% performance improvement over conventional segmentation models in predicting small and visually ambiguous physical features. This work bridges key gaps between deep learning and practical TEM image analysis, advancing automated characterization of nanomaterials in complex experimental settings.

08 HYDROGEN↗

Growth of high quality N-polar AlN(0001) on Si(111) by plasma assisted molecular beam epitaxy

High quality N-polar AlN epilayers were grown and characterized on Si(111) substrates by plasma assisted molecular beam epitaxy as a first step toward growth of N-polar nitrides on Si(111). Polarity inversion to N-face by an optimized predeposition of Al adatoms on the reconstructed 7x7 Si(111) surface was investigated. Al adatoms can saturate the dangling bonds of Si atoms, resulting in growth of AlN in (0001) direction on subsequent exposure to N{sub 2} plasma. N-polarity was confirmed by observing strong 3x3 and 6x6 reflection high-energy electron diffraction reconstructions, convergent beam electron diffraction imaging and KOH etching studies. The structural properties were investigated by x-ray diffraction measurements, cross section and plan-view TEM studies.

36 MATERIALS SCIENCE↗

Additive to regulate the perovskite crystal film growth in planar heterojunction solar cells

We reported a planar heterojunction perovskite solar cell fabricated from MAPbI{sub 3−x}Cl{sub x} perovskite precursor solution containing 1-chloronaphthalene (CN) additive. The MAPbI{sub 3−x}Cl{sub x} perovskite films have been characterized by UV-vis, SEM, XRD, and steady-state photoluminescence (PL). UV-vis absorption spectra measurement shows that the absorbance of the film with CN additive is significantly higher than the pristine film and the absorption peak is red shift by 30 nm, indicating the perovskite film with additive possessing better crystal structures. In-situ XRD study of the perovskite films with additive demonstrated intense diffraction peaks from MAPbI{sub 3−x}Cl{sub x} perovskite crystal planes of (110), (220), and (330). SEM images of the films with additive indicated the films were more smooth and homogenous with fewer pin-holes and voids and better surface coverage than the pristine films. These results implied that the additive CN is beneficial to regulate the crystallization transformation kinetics of perovskite to form high quality crystal films. The steady-state PL measurement suggested that the films with additive contained less charge traps and defects. The planar heterojunction perovskite solar cells fabricated from perovskite precursor solution containing CN additive demonstrated 30% enhancement in performance compared to the devices with pristine films. The improvement in device efficiency is mainly attributed to the good crystal structures, more homogenous film morphology, and also fewer trap centers and defects in the films with the additive.

36 MATERIALS SCIENCE↗

In-situ imaging of nucleation and growth of superlattices from nanoscale colloidal nanoparticles

Nanoparticle-based superlattices have attracted extensive research efforts due to their versatile composition and packing-dependent optical, magnetic, electronic, catalytic, mechanical properties. Yet the experimental understanding of the thermodynamics and pathways of the crystallization processes for these systems, which govern their ultimate morphology, size, and packing structure, has for long remained underexplored. Here, this minireview highlights recent integration of liquid-phase transmission electron microscopy, which allows for real-space, real-time direct imaging of the crystallization processes at the single-particle level, with simulation and the conceptual framework established by pioneers such as Dr. A. A. Chernov. Different aspects of superlattice formation were revealed by direct imaging for the first time, such as the existence of prenucleation precursor in nonclassical crystallization, surface energy-dependent growth, and coalescence, allowing for the charting of phase coordinates and thermodynamic quantities at the nanoscale. We discuss the similarities and differences of crystal growth behaviors in atomic and nanoparticle systems, as well as engineering opportunities to fashion, shape, and achieve quality control in superlattice formation from nanoparticles, for next-generation optical and mechanical metamaterials.

36 MATERIALS SCIENCE↗

Fabrication of 3-{mu}m diameter pin hole array (PHA) on thick W substrates

Pin-hole arrays are used for a variety of applications including, for example, X-ray imaging of laser-plasmas for fusion relevant studies. More recently, a novel X-ray imaging technique has been proposed (this conference L. A. Gizzi et al.) within the High Power Laser Energy Research Facility (HiPER) to obtain spectrally resolved X-ray imaging using single photon detection. This technique requires a large number of images or, alternatively, large arrays of pin-holes, possibly with very small diameter (<<10 {mu}m). In view of this, a technique was implemented for the fabrication of large arrays of pin-holes in thick metal substrates. Here we report on the optimizations of the laser-matter interaction process to obtain high aspect ratio cylinder-like pin-hole on heavy metal substrate by using a frequency-doubled Ti:Sa femtosecond laser pulses operating at 10 Hz. The influence of an air breakdown and a (ns)prepulse, on the drilled pin-hole, is showed by means of SEM images both for surface effects and internal quality of the channels, with evidence of micro and nano-sized structures. The holes drilled at an intensity just below the laser breakdown threshold for plasma creation in air, have an internal diameter of about 3 {mu}m on a W substrate of 70 {mu}m thickness, a micro-cylinder-like shape and no detectable deviations of the axis from a straight line. Arrays of up to 800 pin-holes were produced with the pin-hole properties being highly stable across the array. The final X-ray transmission is showed by using a mu-focus X-ray source.

36 MATERIALS SCIENCE↗

4D-STEM Mapping of Nanocrystal Reaction Dynamics and Heterogeneity in a Graphene Liquid Cell

Chemical reaction kinetics at the nanoscale are intertwined with heterogeneity in structure and composition. However, mapping such heterogeneity in a liquid environment is extremely challenging. Here, in this work, we integrate graphene liquid cell (GLC) transmission electron microscopy and four-dimensional scanning transmission electron microscopy to image the etching dynamics of gold nanorods in the reaction media. Critical to our experiment is the small liquid thickness in a GLC that allows the collection of high-quality electron diffraction patterns at low dose conditions. Machine learning-based data-mining of the diffraction patterns maps the three-dimensional nanocrystal orientation, groups spatial domains of various species in the GLC, and identifies newly generated nanocrystallites during reaction, offering a comprehensive understanding on the reaction mechanism inside a nanoenvironment. This work opens opportunities in probing the interplay of structural properties such as phase and strain with solution-phase reaction dynamics, which is important for applications in catalysis, energy storage, and self-assembly.

four-dimensional scanning transmission electron mi↗

Quantitative imaging and automated fuel pin identification for passive gamma emission tomography

Compliance of member States to the Treaty on the Non-Proliferation of Nuclear Weapons is monitored through nuclear safeguards. The Passive Gamma Emission Tomography (PGET) system is a novel instrument developed within the framework of the International Atomic Energy Agency (IAEA) project JNT 1510, which included the European Commission, Finland, Hungary and Sweden. The PGET is used for the verification of spent nuclear fuel stored in water pools. Advanced image reconstruction techniques are crucial for obtaining high-quality cross-sectional images of the spent-fuel bundle to allow inspectors of the IAEA to monitor nuclear material and promptly identify its diversion. In this work, we have developed a software suite to accurately reconstruct the spent-fuel cross sectional image, automatically identify present fuel rods, and estimate their activity. Unique image reconstruction challenges are posed by the measurement of spent fuel, due to its high activity and the self-attenuation. While the former is mitigated by detector physical collimation, we implemented a linear forward model to model the detector responses to the fuel rods inside the PGET, to account for the latter. The image reconstruction is performed by solving a regularized linear inverse problem using the fast-iterative shrinkage-thresholding algorithm. We have also implemented the traditional filtered back projection (FBP) method based on the inverse Radon transform for comparison and applied both methods to reconstruct images of simulated mockup fuel assemblies. Higher image resolution and fewer reconstruction artifacts were obtained with the inverse-problem approach, with the mean-square-error reduced by 50%, and the structural-similarity improved by 200%. We then used a convolutional neural network (CNN) to automatically identify the bundle type and extract the pin locations from the images; the estimated activity levels finally being compared with the ground truth. The proposed computational methods accurately estimated the activity levels of the present pins, with an associated uncertainty of approximately 5%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A voxel-based finite element model for the prediction of bladder deformation

Purpose: A finite element (FE) bladder model was previously developed to predict bladder deformation caused by bladder filling change. However, two factors prevent a wide application of FE models: (1) the labor required to construct a FE model with high quality mesh and (2) long computation time needed to construct the FE model and solve the FE equations. In this work, we address these issues by constructing a low-resolution voxel-based FE bladder model directly from the binary segmentation images and compare the accuracy and computational efficiency of the voxel-based model used to simulate bladder deformation with those of a classical FE model with a tetrahedral mesh. Methods: For ten healthy volunteers, a series of MRI scans of the pelvic region was recorded at regular intervals of 10 min over 1 h. For this series of scans, the bladder volume gradually increased while rectal volume remained constant. All pelvic structures were defined from a reference image for each volunteer, including bladder wall, small bowel, prostate (male), uterus (female), rectum, pelvic bone, spine, and the rest of the body. Four separate FE models were constructed from these structures: one with a tetrahedral mesh (used in previous study), one with a uniform hexahedral mesh, one with a nonuniform hexahedral mesh, and one with a low-resolution nonuniform hexahedral mesh. Appropriate material properties were assigned to all structures and uniform pressure was applied to the inner bladder wall to simulate bladder deformation from urine inflow. Performance of the hexahedral meshes was evaluated against the performance of the standard tetrahedral mesh by comparing the accuracy of bladder shape prediction and computational efficiency. Results: FE model with a hexahedral mesh can be quickly and automatically constructed. No substantial differences were observed between the simulation results of the tetrahedral mesh and hexahedral meshes (<1% difference in mean dice similarity coefficient to manual contours and <0.02 cm difference in mean standard deviation of residual errors). The average equation solving time (without manual intervention) for the first two types of hexahedral meshes increased to 2.3 h and 2.6 h compared to the 1.1 h needed for the tetrahedral mesh, however, the low-resolution nonuniform hexahedral mesh dramatically decreased the equation solving time to 3 min without reducing accuracy. Conclusions: Voxel-based mesh generation allows fast, automatic, and robust creation of finite element bladder models directly from binary segmentation images without user intervention. Even the low-resolution voxel-based hexahedral mesh yields comparable accuracy in bladder shape prediction and more than 20 times faster in computational speed compared to the tetrahedral mesh. This approach makes it more feasible and accessible to apply FE method to model bladder deformation in adaptive radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved image of intrusive bodies at Newberry Volcano, Oregon, based on 3D gravity modelling

Beneath Newberry Volcano is one of the largest geothermal heat reservoirs in the western United States and it has been extensively studied for the last 40 years. Several magmatic intrusions have been recognized at depths between 2.5 and 8 km and some of them identified as suitable targets for enhanced geothermal energy and tested during two previous EGS campaigns. These subsurface structures have been intersected by three deep wells and imaged by various geophysical methods including seismic tomography and magnetotellurics. Although three high quality gravity surveys were completed between 2006 and 2010 as part of various projects, a complete synthesis and interpretation of the gravity data has not yet been performed. Regional gravity data also exist in the vicinity of the Newberry volcano and have been added to these surveys to constitute a dataset with a total of 1418 gravity measurements. When coupled with existing geologic and geophysical data and models, this new gravity dataset provides important constraints on the depth and contours of the magmatic bodies previously identified by other methods and thus greatly contributing to facilitate any future drilling and stimulation works. Using the initial structures discovered by seismic tomography, inversion of gravity data has been performed. Shape, density values and depths of various bodies were allowed to vary and three main bodies have been identified. Densities of the middle and lower intrusive bodies (~2.6-2.7 g/cm3) are consistent with rhyolite, basalt or granites. Modeled density of the near-surface caldera body match that of a low density tephra material and the density of the shallow ring structures contained in the upper kilometer correspond to that of welded tuff or low-density rhyolites. Modeled bodies are in reality a composite of thin layers; however, average densities of the modeled gravity bodies are in good agreement with the density log obtained in one well located on the western flank (well 55-29). Final gravity data residuals show that most of the observed gravity anomalies at the surface can be explained by the modeled gravity bodies and are consistent with other site characterization information.

Cascade Range↗