The Thermal Emission Imaging System (THEMIS) Instrument for the Mars 2001 Orbiter

The primary objective of the Thermal Emission Imaging System (THEMIS) on the Mars Surveyor '01 Orbiter is to study the composition of the Martian surface at high spatial resolution. THEMIS will map the surface mineralogy using multi-spectral thermal infrared images in 8 spectral bands from 6.5 to 14.5 microns. In addition, a band centered at 15 microns will be used to map atmospheric temperatures and provide an important aid in separating the surface and atmospheric components. The entire planet will be mapped at 100 m resolution within the available data volume using a multi-spectral, rather than hyperspectral, imaging approach. THEMIS will also acquire 20 m resolution visible images in up to 5 spectral bands using a replica of the Mars 98 Orbiter (MARCI) and Lander (MARDI) cameras. Over 15,000 panchromatic (3,000 5-color), 20 x 20 km images will be acquired for morphology studies and landing site selection. The thermal-infrared spectral region contains the fundamental vibrational absorption bands of most minerals which provide diagnostic information on mineral composition. All geologic materials, including carbonates, hydrothermal silica, sulfates, phosphates, hydroxides, silicates, and oxides have strong absorptions in the 6.5-14.5 micron region. Silica and carbonates, which are key diagnostic minerals in thermal spring deposits, are readily identified using thermal-IR spectra. In addition, the ability to identify all minerals allows the presence of aqueous minerals to be interpreted in the proper geologic context. An extensive suite of studies over the past 35 years has demonstrated the utility of vibrational spectroscopy for the quantitative determination of mineralogy and petrology. The fundamental vibrations within different anion groups, such as C03, S04, P04, and SiO4, produce unique, well separated spectral bands that allow carbonates, sulfates, phosphates, silicates, oxides, and hydroxides to be readily identified. Additional stretching and bending modes involving major cations, such as Mg, Fe, Ca, and Na, allow Further mineral identification, such as the excellent discriminability of minerals within the silicate and carbonate groups.

Christensen, P. R.↗

High Resolution Imaging Spectrometer (HIRIS): Science and Instrument

The High Resolution Imaging Spectrometer (HIRIS) is a facility instrument slated for flight on the second of the EOS-A series of platforms. HIRIS is designed to acquire 24-km wide, 30-m pixel images in 192 spectral bands simultaneously in the 0.4-2.45-micrometer wavelength region. With pointing mirrors it can sample any place on Earth, except the poles, every two days. HIRIS operates at the intermediate scale between the human and the global and therefore links studies of Earth surface processes to global monitoring carried out by lower-resolution instruments. So far, over 50 science data products from HIRIS images have been identified in the fields of atmospheric gases, clouds, snow and ice, water, vegetation, and rocks and soils. The key attribute of imaging spectrometry that makes it possible to derive quantitative information from the data is the large number of contiguous spectral bands. Therefore spectrum matching techniques can be applied. Such techniques are not possible with present-day, multispectral scanner data.

Goetz, Alexander F. H.↗

Characteristics of the GOES I-M Imager and Sounder

The design and the parameters of the improved thermal-imaging and sounding instruments (the Imager and the Sounder) that will be part of the instrument complements of the next-generation Geostationary Operational Environmental Satellite (GOES I-M) are discussed. The new design incorporates many features that enhance instrumental reliability over the previous GOES radiometric instruments, such as independently functioning Sounder and Imager, redundancy, and more reliable position sensors and lubrication methods. Tables are presented which list the instrument parameters of the GOES I-M Imager and Sounder and the performance characteristics of the two instruments.

Ernst, Thomas J.↗

A geostationary imaging spectrometer TOMS instrument

One design for a geostationary Total Ozone Mapping Spectrometer (TOMS) with many desirable features is an imaging spectrometer. A preliminary study makes use of a 0.25 m Czerny-Turner spectrometer with which the Earth is imaged on a charge-coupled device (CCD) in dispersed light. The wavelength is determined by a movable grating which can be set arbitrarily by ground control. The signal integration time depends on wavelength but this system allows arbitrary timing by command. Special circumstances such as a requirement to track a low-lying sulfur dioxide cloud or a need to discriminate high level ozone from total ozone at midlatitudes could be obtained by adding a particular wavelength to the normally pre-programmed time sequence. The incident solar irradiance is measured by deploying a diffuser plate in the field of view. Individual detector elements correspond to scene elements in which the several wavelengths are serially sampled and the Earth radiance is compared to the incident sunlight. Thus the problem of uncorrelated drift of multiple detectors is removed.

Krueger, Arlin J.↗

Precision Instrument Targeting via Image Registration for the Mars 2020 Rover

A key component of Mars exploration is the operation of robotic instruments on the surface, such as those on board the Mars Exploration Rovers, the Mars Science Laboratory (MSL), and the planned Mars 2020 Rover. As the instruments carried by these rovers have become more advanced, the area targeted by some instruments becomes smaller, revealing more fine-grained details about the geology and chemistry of rocks on the surface. However, thermal fluctuations, rover settling or slipping, and inherent inaccuracies in pointing mechanisms all lead to pointing error that is on the order of the target size (several millimeters) or larger. We show that given a target located on a previously acquired image, the rover can align this with a new image to visually locate the target and refine the current pointing. Due to round-trip communication constraints, this visual targeting must be done efficiently on board the rover using relatively limited computing hardware. We employ existing ORB features for landmark-based image registration, describe and theoretically justify a novel approach to filtering false landmark matches, and employ a random forest classifier to automatically reject failed alignments. We demonstrate the efficacy of our approach using over 3,800 images acquired by Remote Micro-Imager on board the “Curiosity” rover.

Doran, Gary↗

Innovative operating modes and techniques for the spaceborne imaging radar-C instrument

The operation of the spaceborne imaging radar-C (SIR-C) is discussed. The SIR-C instrument has been designed to obtain simultaneous multifrequency and simultaneous multipolarization radar images from a low earth orbit. It is a multiparameter imaging radar which will be flown during at least two different seasons. The instrument has been designed to operate in innovative modes such as the squint alignment mode, the extended aperture mode, the scansar mode, and the interferometry mode. The instrument has been designed to demonstrate innovative engineering techniques such as beam nulling for echo tracking, pulse-repetition frquency hopping for Doppler centroid tracking, generating the frequency step chirp for radar parameter flexibility, block floating point quantizing for data rate compression, and elevation beamwidth broadening for increasing the swath illumination.

Huneycutt, Bryan L.↗

Far Ultraviolet Imaging from the Image Spacecraft

Direct imaging of the magnetosphere by the IMAGE spacecraft will be supplemented by observation of the global aurora. The IMAGE satellite instrument complement includes three Far Ultraviolet (FUV) instruments. The Wideband Imaging Camera (WIC) will provide broad band ultraviolet images of the aurora for maximum spatial and temporal resolution by imaging the LBH N2 bands of the aurora. The Spectrographic Imager (SI), a novel form of monochromatic imager, will image the aurora, filtered by wavelength. The proton-induced component of the aurora will be imaged separately by measuring the Doppler-shifted Lyman-a. Finally, the GEO instrument will observe the distribution of the geocoronal emission to obtain the neutral background density source for charge exchange in the magnetosphere. The FUV instrument complement looks radially outward from the rotating IMAGE satellite and, therefore, it spends only a short time observing the aurora and the Earth during each spin. To maximize photon collection efficiency and use efficiently the short time available for exposures the FUV auroral imagers WIC and SI both have wide fields of view and take data continuously as the auroral region proceeds through the field of view. To minimize data volume, the set of multiple images are electronically co-added by suitably shifting each image to compensate for the spacecraft rotation. In order to minimize resolution loss, the images have to be distort ion-corrected in real time. The distortion correction is accomplished using high speed look up tables that are pre-generated by least square fitting to polynomial functions by the on-orbit processor. The instruments were calibrated individually while on stationary platforms, mostly in vacuum chambers. Extensive ground-based testing was performed with visible and near UV simulators mounted on a rotating platform to emulate their performance on a rotating spacecraft.

Mende, S. B.↗

RTN-117: Image Calibration and Instrument Signal Removal for the First Year of the LSST

The NSF-DOE Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) requires calibration products that provide uniform, stable, and accurate photometric and astrometric performance across the 3.2 gigapixel focal plane and throughout the 10-year survey. This paper details the algorithms and workflows used to produce instrument calibrations and remove instrumental artifacts for Data Preview 2 (DP2)---the first end-to-end processing demonstration using on-sky data with the LSST Camera (LSSTCam). We describe the verification, acceptance, and certification framework used to assess calibration quality and quantify residual systematics. We show baseline metrics on calibrated science images to evaluate the robustness of the calibration and instrument signature removal (ISR) data processing pipelines for DP2. Finally, we summarize the known limitations observed in DP2 production and outline expected algorithmic improvements for the first public LSST data release (Data Release~1, DR1).

79 ASTRONOMY AND ASTROPHYSICS↗

Portable dynamic fundus instrument

A portable diagnostic image analysis instrument is disclosed for retinal funduscopy in which an eye fundus image is optically processed by a lens system to a charge coupled device (CCD) which produces recordable and viewable output data and is simultaneously viewable on an electronic view finder. The fundus image is processed to develop a representation of the vessel or vessels from the output data.

Taylor, Gerald R.↗

Instrumentation and robotic image processing using top-down model control

A top-down image processing scheme is described. A three-dimensional model of a robotic working environment, with robot manipulators, workpieces, cameras, and on-the-scene visual enhancements is employed to control and direct the image processing, so that rapid, robust algorithms act in an efficient manner to continually update the model. Only the model parameters are communicated, so that savings in bandwidth are achieved. This image compression by modeling is especially important for control of space telerobotics. The background for this scheme lies in an hypothesis of human vision put forward by the senior author and colleagues almost 20 years ago - the Scanpath Theory. Evidence was obtained that repetitive sequences of saccadic eye movements, the scanpath, acted as the checking phase of visual pattern recognition. Further evidence was obtained that the scanpaths were apparently generated by a cognitive model and not directly by the visual image. This top-down theory of human vision was generalized in some sense to the frame in artificial intelligence. Another source of the concept arose from bioengineering instrumentation for measuring the pupil and eye movements with infrared video cameras and special-purpose hardware.

Stark, Lawrence↗

The Cusp Plasma Imaging Detector (Cupid) Cubesat Observatory: Instrumentation

The Cusp Plasma Imaging Detector (CuPID) CubeSat observatory is a 6U CubeSat designed to observe solar wind charge exchange in magnetospheric cusps to test competing theories of magnetic reconnection at the Earth’s magnetopause. The CuPID is equipped with three instruments, namely, a wide field-of-view (4.6° × 4.6°) soft x-ray telescope, a micro-dosimeter suite, and an engineering magnetometer optimized for the science operation. The instrument suite has been tested and calibrated in relevant environments, demonstrating successful design. The testing and calibration of these instruments produced metrics and coefficients that will be used to create the CuPID mission’s data product.

Magnetospheric dynamics↗

The Solar Orbiter SPICE Instrument An Extreme UV imaging spectrometer

Aims. The Spectral Imaging of the Coronal Environment (SPICE) instrument is a high-resolution imaging spectrometer operating at extreme ultraviolet wavelengths. In this paper, we present the concept, design, and pre-launch performance of this facility instrument on the ESA/NASA Solar Orbiter mission. Methods. The goal of this paper is to give prospective users a better understanding of the possible types of observations, the data acquisition, and the sources that contribute to the instrument’s signal. Results. The paper discusses the science objectives, with a focus on the SPICE-specific aspects, before presenting the instrument’s design, including optical, mechanical, thermal, and electronics aspects. This is followed by a characterisation and calibration of the instrument’s performance. The paper concludes with descriptions of the operations concept and data processing. Conclusions. The performance measurements of the various instrument parameters meet the requirements derived from the mission’s science objectives. The SPICE instrument is ready to perform measurements that will provide vital contributions to the scientific success of the Solar Orbiter mission.

M. Anderson↗

Spaceborne Imaging Radar-C instrument

The present discussion of the Spaceborne Imaging Radar-C (SIR-C) hardware design, subsystem functional design, and interfaces with the NASA Space Shuttle, gives attention to antenna characteristics and to instrument performance parameter characteristics in the C- and L-bands. The SIR-C antenna is a dual-frequency, dual-polarization distributed array antenna whose distribution of transmit/receive modules improves the system noise figure and eliminates the need for a single, high-power RF source. Phase shifters for individual subarrays allow electronic beam steering in elevation and azimuth.

Huneycutt, Bryan L.↗

Electrographic instrumentation for ultraviolet imaging and spectrography

The latest results in the NRL program of far-UV electrographic camera development, and application of these cameras to astrophysical and upper-atmospheric investigations, are presented. A new large electrographic Schmidt camera, of 15 cm aperture and f/2 focal ratio, has been successfully used in two sounding rocket flights, one for direct imagery in the 1230-2000 A wavelength range and the second for objective spectrography in the 950-2000 A range, of stars and nebulae in the Cygnus region of the sky. The camera has an 11 deg field of view and better than 30 arcsec resolution (2 A spectral resolution with 600 line/mm objective grating). A nebular spectrograph, based on a microchannel-intensified electrographic Schmidt camera, is the payload of a May 1979 rocket flight. It will reach emission line features as faint as 5 Rayleighs in 100 second exposures in the 1050-2000 A range, with 5 A spectral resolution.

Carruthers, G. R.↗

Summary of Quantitative Interpretation of Image Far Ultraviolet Auroral Data

Direct imaging of the magnetosphere by instruments on the IMAGE spacecraft is supplemented by simultaneous observations of the global aurora in three far ultraviolet (FUV) wavelength bands. The purpose of the multi-wavelength imaging is to study the global auroral particle and energy input from thc magnetosphere into the atmosphere. This paper describes provides the method for quantitative interpretation of FUV measurements. The Wide-Band Imaging Camera (WIC) provides broad band ultraviolet images of the aurora with maximum spatial and temporal resolution by imaging the nitrogen lines and bands between 140 and 180 nm wavelength. The Spectrographic Imager (SI), a dual wavelength monochromatic instrument, images both Doppler-shifted Lyman alpha emissions produced by precipitating protons, in the SI-12 channel and OI 135.6 nm emissions in the SI-13 channel. From the SI-12 Doppler shifted Lyman alpha images it is possible to obtain the precipitating proton flux provided assumptions are made regarding the mean energy of the protons. Knowledge of the proton (flux and energy) component allows the calculation of the contribution produced by protons in the WIC and SI-13 instruments. Comparison of the corrected WIC and SI-13 signals provides a measure of the electron mean energy, which can then be used to determine the electron energy fluxun-. To accomplish this reliable modeling emission modeling and instrument calibrations are required. In-flight calibration using early-type stars was used to validate the pre-flight laboratory calibrations and determine long-term trends in sensitivity. In general, very reasonable agreement is found between in-situ measurements and remote quantitative determinations.

Frey, H. U.↗

Shuttle Imaging Radar-B/C instruments

The successfully flown Shuttle Imaging Radar-B (SIR-B) instrument is described, giving details of the hardware, the subsystem functions, and the Shuttle interfaces. The preliminary design of the SIR-C instrument is described, giving an overview of the preliminary hardware design, the subsystem functional design, and the Shuttle interfaces.

Huneycutt, Bryan L.↗

Thermal Infrared Imaging Spectrometer - An advanced optics technology instrument

Through the use of a special optical filter, the Thermal Infrared Imaging Spectrometer, an airborne multispectral IR imaging instrument operating in the thermal emission region (7.5-14 microns), will achieve signal-to-noise ratios greater than 600 with ambient temperature optics. This instrument will be used to do compositional surface mapping of the terrain, and will refine the ability to categorize rock families and types by providing much higher spectral resolution in the emission region than was previously available. Details of the optical system, the detector, the cooler system, and the support electronics are described.

Mahoney, Colin↗