Noncontact Andreev Reflection as a Direct Probe of Superconductivity on the Atomic Scale

Direct detection of superconductivity has long been a key strength of point-contact Andreev reflection. However, its applicability to atomic-scale imaging is limited by the mechanical contact of the Andreev probe. To this end, we present a new method to probe Andreev reflection in a tunnel junction, leveraging tunneling spectroscopy and junction tunability to achieve quantitative detection of Andreev scattering. This method enables unambiguous assignment of superconducting origins of current-carrying excitations, as well as detection of higher order Andreev processes in atomic-scale junctions. Herein, we furthermore revealed distinct sensitivity of Andreev reflection to natural defects, such as step edges, even in classical superconductors. The methodology opens a new path to nano- and atomic-scale imaging of superconducting properties, including disordered superconductors and proximity to phase transitions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Proton acceleration in an overdense hydrogen plasma by intense CO 2 laser pulses with nonlinear propagation effects in the underdense pre-plasma

We report on proton acceleration from intense CO 2 laser-irradiated hydrogen plasmas at near-critical densities, with the density gradient steepened by Nd:YAG laser ablation-driven hydrodynamic shocks. While the experimental results, such as the quasi-monoenergetic proton spectra and their scaling with respect to the laser energy, are generally in agreement with the simulations, certain laser shots produced significantly higher proton energies than anticipated during the experiment. The increased proton energy may be linked to nonlinear propagation effects in the steepened plasma density ramp before the critical surface, including relativistic self-focusing and, for the case of temporally-structured laser pulses observed in the experiment, focusing of the trailing pulse through the plasma channel formed by the leading pulse 25 ps ahead. The occurrence of channel focusing in the underdense hydrogen plasma is supported by a subsequent pump-probe experiment with a dark-field imaging technique, where the formation of ion channels was observed after the passage of an intense CO 2 laser pulse

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toward Smart, Automated Junctional Tourniquets—AI Models to Interpret Vessel Occlusion at Physiological Pressure Points

Hemorrhage is the leading cause of preventable death in both civilian and military medicine. Junctional hemorrhages are especially difficult to manage since traditional tourniquet placement is often not possible. Ultrasound can be used to visualize and guide the caretaker to apply pressure at physiological pressure points to stop hemorrhage. However, this process is technically challenging, requiring the vessel to be properly positioned over rigid boney surfaces and applying sufficient pressure to maintain proper occlusion. As a first step toward automating this life-saving intervention, we demonstrate an artificial intelligence algorithm that classifies a vessel as patent or occluded, which can guide a user to apply the appropriate pressure required to stop flow. Neural network models were trained using images captured from a custom tissue-mimicking phantom and an ex vivo swine model of the inguinal region, as pressure was applied using an ultrasound probe with and without color Doppler overlays. Using these images, we developed an image classification algorithm suitable for the determination of patency or occlusion in an ultrasound image containing color Doppler overlay. Separate AI models for both test platforms were able to accurately detect occlusion status in test-image sets to more than 93% accuracy. In conclusion, this methodology can be utilized for guiding and monitoring proper vessel occlusion, which, when combined with automated actuation and other AI models, can allow for automated junctional tourniquet application.

60 APPLIED LIFE SCIENCES↗

2022 Prentice Award Lecture: Advancing Retinal Imaging and Visual Function in Patient Management and Disease Mechanisms

Patient-based research plays a key role in probing basic visual mechanisms. Less-well recognized is the role of patient-based retinal imaging and visual function studies in elucidating disease mechanisms, which are accelerated by advances in imaging and function techniques and are most powerful when combined with the results from histology and animal models. A patient's visual complaints can be one key to patient management, but human data are also key to understanding disease mechanisms. Unfortunately, pathological changes can be difficult to detect. Before advanced retinal imaging, the measurement of visual function indicated the presence of pathological changes that were undetectable with existing clinical examination. Over the past few decades, advances in retinal imaging have increasingly revealed the unseen. This has led to great strides in the management of many diseases, particularly diabetic retinopathy and macular edema, and age-related macular degeneration. It is likely widely accepted that patient-based research, as in clinical trials, led to such positive outcomes. Both visual function measures and advanced retinal imaging have clearly demonstrated differences among retinal diseases. Contrary to initial thinking, sight-threatening damage in diabetes occurs to the outer retina and not only to the inner retina. This has been clearly indicated in patient results but has only gradually entered the clinical classifications and understanding of disease etiology. There is strikingly different pathophysiology for age-related macular degeneration compared with photoreceptor and retinal pigment epithelial genetic defects, yet research models and even some treatments confuse these. It is important to recognize the role that patient-based research plays in probing basic visual mechanisms and elucidating disease mechanisms, combining these findings with the concepts from histology and animal models. Thus, this article combines sample instrumentation from my laboratory and progress in the fields of retinal imaging and visual function.

60 APPLIED LIFE SCIENCES↗

Ultrafast infrared nano-imaging of far-from-equilibrium carrier and vibrational dynamics

Ultrafast infrared nano-imaging has demonstrated access to ultrafast carrier dynamics on the nanoscale in semiconductor, correlated-electron, or polaritonic materials. However, mostly limited to short-lived transient states, the contrast obtained has remained insufficient to probe important long-lived excitations, which arise from many-body interactions induced by strong perturbation among carriers, lattice phonons, or molecular vibrations. Here, we demonstrate ultrafast infrared nano-imaging based on excitation modulation and sideband detection to characterize electron and vibration dynamics with nano- to micro-second lifetimes. As an exemplary application to quantum materials, in phase-resolved ultrafast nano-imaging of the photoinduced insulator-to-metal transition in vanadium dioxide, a distinct transient nano-domain behavior is quantified. In another application to lead halide perovskites, transient vibrational nano-FTIR spatially resolves the excited-state polaron-cation coupling underlying the photovoltaic response. These examples show how heterodyne pump-probe nano-spectroscopy with low-repetition excitation extends ultrafast infrared nano-imaging to probe elementary processes in quantum and molecular materials in space and time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correlating Nanoscale Secondary Ion Mass Spectrometry and Atom Probe Tomography Analysis of Uranium Enrichment in Metallic Nuclear Fuel

Distribution and enrichment of 235U within nuclear fuels are essential to material performance and reactor safety. With the development of metallic U fuels, understanding 235U homogeneity has become increasingly important, however, it is difficult to map with high spatial, and mass resolution to analyze both matrix and secondary phase precipitates. Here, we analyze 235U enrichment in matrix and carbide phases in LEU-Mo via two chemical imaging modalities: nanoscale secondary ion mass spectrometry (nanoSIMS) and atom probe tomography (APT). NanoSIMS and APT provided consistent results, with no statistically significant difference between measured and nominal enrichment (19.75 % 235U).

U-10Mo, atom probe tomography, nanoscale secondary↗

Flexible Soft X-Ray Image Sensors based on Metal Halide Perovskites With High Quantum Efficiency

Soft X-ray imaging is a powerful tool to explore the structure of cells, probe material with nanometer resolution, and investigate the energetic phenomena in the universe. Conventional soft X-ray image sensors are by and large Si-based charge coupled devices that suffer from low frame rates, complex fabrication processes, mechanical inflexibility, and required cooling below -60 °C. Here, a soft X-ray photodiode is reported based on low-cost metal halide perovskite with comparable performance to commercial Si-based device. Nanothrough network electrode minimized the optical loss due to the shadowing of insensitive layers, while a multidimensional perovskite heterojunction is generated to reduce the photo-generated carrier loss. Further, this strategy promoted a record quantum efficiency of 8 × 10 3 % without cooling, several orders of magnitude greater than the previously achieved. Flexible and curved soft X-ray imaging arrays are fabricated based on this high-performance device structure, demonstrating stable soft X-ray response and sharp imaging capabilities. This work highlights the low-cost and efficient perovskite photodiode as a strong candidate for the next-generation soft X-ray image sensors.

36 MATERIALS SCIENCE↗

Imaging from Macro to Nanoscale: Multimodal Advances in Chemical and Biomedical Imaging

Imaging increasingly serves as a multiscale framework for linking molecular mechanisms to cellular behavior, tissue architecture, and organ phenotypes in biology and unraveling fundamental processes in chemistry, physics and materials science. This Perspective highlights recent advances in chemical and biomedical imaging across macro-, micro-, and nanoscales, using representative examples published in Chemical and Biomedical Imaging (CBMI). At the macroscale, we discuss chemically selective MRI, including endogenous and exogenous CEST strategies, together with photoacoustic imaging as a hybrid modality with functional and chemical contrast. At the microscale, we consider fluorescence, label-free optical and vibrational imaging, and selected X-ray approaches that expand sensitivity, specificity, and temporal resolution in biological and materials systems. At the nanoscale, we highlight super-resolution fluorescence microscopy, single-molecule methods, tip-enhanced Raman spectroscopy, and correlative imaging strategies that resolve local heterogeneity and molecular organization. Across scales, a common theme emerges that advances in probes, contrast mechanisms, instrumentation, and sample handling are enabling chemically informed imaging that connects molecular specificity with biological context.

multiscale imaging↗

py4DSTEM: A Software Package for Four-Dimensional Scanning Transmission Electron Microscopy Data Analysis

Scanning transmission electron microscopy (STEM) allows for imaging, diffraction, and spectroscopy of materials on length scales ranging from microns to atoms. By using a high-speed, direct electron detector, it is now possible to record a full two-dimensional (2D) image of the diffracted electron beam at each probe position, typically a 2D grid of probe positions. These 4D-STEM datasets are rich in information, including signatures of the local structure, orientation, deformation, electromagnetic fields, and other sample-dependent properties. However, extracting this information requires complex analysis pipelines that include data wrangling, calibration, analysis, and visualization, all while maintaining robustness against imaging distortions and artifacts. In this paper, we present py4DSTEM, an analysis toolkit for measuring material properties from 4D-STEM datasets, written in the Python language and released with an open-source license. We describe the algorithmic steps for dataset calibration and various 4D-STEM property measurements in detail and present results from several experimental datasets. We also implement a simple and universal file format appropriate for electron microscopy data in py4DSTEM, which uses the open-source HDF5 standard. We hope this tool will benefit the research community and help improve the standards for data and computational methods in electron microscopy, and we invite the community to contribute to this ongoing project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DEVELOPMENT OF A QUANTUM ELECTRON BEAM DIAGNOSTIC APPARATUS

Spatial properties of electron beams are the essential parameters needed in particle physics and accelerator research. Beam characterization using optical detection methods through the interaction between photons and electrons such as Compton scattering, or electro-optic sampling of the electric field of electrons have been extensively explored and successfully implemented as non-invasive diagnostics at various accelerator facilities. However, such methods often suffer from inherently low sensitivity. Here we present the study of a new type of electron beam diagnostic device for direct optical imaging of electron beams at various energy levels. The concept is based on the extremely high sensitivity of atoms, prepared in a specific "dark superposition" quantum state, to the external electric or magnetic perturbations induced by the passing charged particle, which allows atoms to change polarization of the probe light or absorb probe light and to fluoresce, enabling direct 3D imaging of the charged particles with high resolution. We report our recent experiment results and the design effort on a compact apparatus intended to be tested with the relativistic electron beams at Jefferson Laboratory.

Zhang, S.↗

LensWatch. I. Resolved HST Observations and Constraints on the Strongly Lensed Type Ia Supernova 2022qmx (“SN Zwicky”)

Supernovae (SNe) that have been multiply imaged by gravitational lensing are rare and powerful probes for cosmology. Each detection is an opportunity to develop the critical tools and methodologies needed as the sample of lensed SNe increases by orders of magnitude with the upcoming Vera C. Rubin Observatory and Nancy Grace Roman Space Telescope. The latest such discovery is of the quadruply imaged Type Ia SN 2022qmx (aka, "SN Zwicky") at z = 0.3544. SN Zwicky was discovered by the Zwicky Transient Facility in spatially unresolved data. Here we present follow-up Hubble Space Telescope observations of SN Zwicky, the first from the multicycle "LensWatch (www.lenswatch.org)" program. We measure photometry for each of the four images of SN Zwicky, which are resolved in three WFC3/UVIS filters (F475W, F625W, and F814W) but unresolved with WFC3/IR F160W, and present an analysis of the lensing system using a variety of independent lens modeling methods. We find consistency between lens-model-predicted time delays (≲1 day), and delays estimated with the single epoch of Hubble Space Telescope colors (≲3.5 days), including the uncertainty from chromatic microlensing (~1–1.5 days). Our lens models converge to an Einstein radius of ${\theta }_{{\rm{E}}}=({0.168}_{-0.005}^{+0.009})^{\prime\prime} $, the smallest yet seen in a lensed SN system. The "standard candle" nature of SN Zwicky provides magnification estimates independent of the lens modeling that are brighter than predicted by $\sim {1.7}_{-0.6}^{+0.8}$ mag and $\sim {0.9}_{-0.6}^{+0.8}$ mag for two of the four images, suggesting significant microlensing and/or additional substructure beyond the flexibility of our image-position mass models.

79 ASTRONOMY AND ASTROPHYSICS↗

High redshift LBGs from deep broadband imaging for future spectroscopic surveys

Lyman break galaxies (LBGs) are promising probes for clustering measurements at high redshift, z > 2, a region only covered so far by Lyman-α forest measurements. Here, in this paper, we investigate the feasibility of selecting LBGs by exploiting the existence of a strong deficit of flux shortward of the Lyman limit, due to various absorption processes along the line of sight. The target selection relies on deep imaging data from the HSC and CLAUDS surveys in the g, r, z and u bands, respectively, with median depths reaching 27 AB in all bands. The selections were validated by several dedicated spectroscopic observation campaigns with DESI. Visual inspection of spectra has enabled us to develop an automated spectroscopic typing and redshift estimation algorithm specific to LBGs. Based on these data and tools, we assess the efficiency and purity of target selections optimised for different purposes. Selections providing a wide redshift coverage retain 57% of the observed targets after spectroscopic confirmation with DESI, and provide an efficiency for LBGs of 83 ± 3%, for a purity of the selected LBG sample of 90 ± 2%. This would deliver a confirmed LBG density of ~ 620 deg$^{-2}$ in the range 2.3 < z < 3.5 for a r-band limiting magnitude r < 24.2. Selections optimised for high redshift efficiency retain 73% of the observed targets after spectroscopic confirmation, with 89 ± 4% efficiency for 97 ± 2% purity. This would provide a confirmed LBG density of ~ 470 deg$^{-2}$ in the range 2.8 < z < 3.5 for a r-band limiting magnitude r < 24.5.A preliminary study of the LBG sample 3d-clustering properties is also presented and used to estimate the LBG linear bias. A value of b$_{LBG}$ = 3.3 ± 0.2 (stat.) is obtained for a mean redshift of 2.9 and a limiting magnitude in r of 24.2, in agreement with results reported in the literature.

79 ASTRONOMY AND ASTROPHYSICS↗

Does Selectivity of Molecular Catalysts Change with Time? Polymerization Imaged by Single‐Molecule Spectroscopy

Abstract The chemoselectivity of molecular catalysts underpins much of modern synthetic organic chemistry. However, little is known about the selectivity of individual catalysts because this single‐catalyst‐level behavior is hidden by the bulk catalytic behavior. Here, for the first time, the selectivity of individual molecular catalysts for two different reactions is imaged in real time at the single‐catalyst level. This imaging is achieved through fluorescence microscopy paired with spectral probes that produce a snapshot of the instantaneous chemoselectivity of a single catalyst for either a single‐chain‐elongation or a single‐chain‐termination event during ruthenium‐catalyzed polymerization. Superresolution imaging of multiple selectivity events, each at a different single‐molecular ruthenium catalyst, indicates that catalyst selectivity may be unexpectedly spatially and time‐variable.

Garcia, IV, Antonio↗

Device-Level Multidimensional Thermal Dynamics With Implications for Current and Future Wide Bandgap Electronics

Researchers have been extensively studying wide-bandgap (WBG) semiconductor materials such as gallium nitride (GaN) with an aim to accomplish an improvement in size, weight, and power of power electronics beyond current devices based on silicon (Si). However, the increased operating power densities and reduced areal footprints of WBG device technologies result in significant levels of self-heating that can ultimately restrict device operation through performance degradation, reliability issues, and failure. Typically, self-heating in WBG devices is studied using a single measurement technique while operating the device under steady-state direct current measurement conditions. However, for switching applications, this steady-state thermal characterization may lose significance since the high power dissipation occurs during fast transient switching events. Therefore, it can be useful to probe the WBG devices under transient measurement conditions in order to better understand the thermal dynamics of these systems in practical applications. In this work, the transient thermal dynamics of an AlGaN/GaN high electron mobility transistor (HEMT) were studied using thermoreflectance thermal imaging and Raman thermometry. Also, the proper use of iterative pulsed measurement schemes such as thermoreflectance thermal imaging to determine the steady-state operating temperature of devices is discussed. These studies are followed with subsequent transient thermal characterization to accurately probe the self-heating from steady-state down to submicrosecond pulse conditions using both thermoreflectance thermal imaging and Raman thermometry with temporal resolutions down to 15 ns.

42 ENGINEERING↗

An imaging refractometer for density fluctuation measurements in high energy density plasmas

In this work, we report on a recently developed laser-probing diagnostic which allows direct measurements of ray-deflection angles in one axis, whilst retaining imaging capabilities in the other axis. This allows us to measure the spectrum of angular deflections from a laser beam which passes though a turbulent high-energy-density plasma. This spectrum contains information about the density fluctuations within the plasma, which deflect the probing laser over a range of angles. We create synthetic diagnostics using ray-tracing to compare this new diagnostic with standard shadowgraphy and schlieren imaging approaches, which demonstrates the enhanced sensitivity of this new diagnostic over standard techniques. We present experimental data from turbulence behind a reverse shock in a plasma and demonstrate that this technique can measure angular deflections between 0.06 and 34 mrad, corresponding to a dynamic range of over 500.

47 OTHER INSTRUMENTATION↗

Vacuum-Healing of Grain Boundaries in Sodium-Doped CuInSe 2 Solar Cell Absorbers

Alkali metal doping and grain boundaries (GB) have been at the center of attention within the Cu(In,Ga)(S,Se) 2 photovoltaics community for years. This study provides the first experimental evidence that the GB of sodium-doped CuInSe 2 thin films may undertake reversible oxidation even at room temperature, whereas undoped films may not. The findings are corroborated by cathodoluminescence imaging, secondary ion mass spectrometry, and Kelvin probe force microscopy on air-exposed films subsequently subject to vacuum. A thermochemical assessment identifies the likely solid-gas equilibria involved. These reactions open new research questions with respect to the beneficial role played by alkali metal dopants in chalcopyrite solar cells and may steer the community toward new breakthroughs.

14 SOLAR ENERGY↗

Expanded Coverage of Phytocompounds by Mass Spectrometry Imaging Using On-Tissue Chemical Derivatization by 4-APEBA

Probing the entirety of any species metabolome is an analytical grand challenge, especially at a cellular scale. Where spatial metabolomics, completed primarily by matrix-assisted laser desorption/ionization (MALDI), has limited molecular coverage for several reasons. To expand the scope of spatial metabolomics, we developed an on-tissue chemical derivatization (OTCD) workflow using 4-APEBA for confident identification of several dozen elusive phytocompounds, including several phytohormones, which have various roles within stress responses and cellular communication. Superiority of 4-APEBA is established in comparison to other derivatization agents with (1) broad specificity towards carbonyls, (2) low background, and (3) introduction of bromine isotopes, where the latter two facilitate confident bioinformatics. In conclusion, the outlined workflow trailblazes a path towards spatial hormonomics within plant samples, enhancing detection of carboxylates, aldehydes, ketones, and plausibly phenols.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatial Mapping of Electrostatic Fields in 2D Heterostructures

In situ electron microscopy is an effective tool for understanding the mechanisms driving novel phenomena in 2D structures. However, due to practical challenges, it is difficult to address these technologically relevant 2D heterostructures with electron microscopy. Here, we use the differential phase contrast (DPC) imaging technique to build a methodology for probing local electrostatic fields during electrical operation with nanoscale spatial resolution in such materials. We find that, by combining a traditional DPC setup with a high-pass filter, we can largely eliminate electric fluctuations emanating from short-range atomic potentials. Using a method based on this filtering algorithm, a priori electric field expectations can be directly compared with experimentally derived values to readily identify inhomogeneities and potentially problematic regions. Furthermore, we use this platform to analyze the electric field and charge density distribution across layers of hBN and MoS 2 .