Search NASA⌕ Search

SEARCH · Search NASA

Results for “instrument development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Dry in-pile fracture test (DRIFT) for separate-effects validation of ceramic fuel fracture models

Fracture is an important component of nuclear fuel behavior, and significant efforts have been invested into developing fuel performance models that are capable of accurately representing fracture. Usable data on the process of fracture propagation in nuclear fuel under realistic service conditions are very limited. To address this need, a series of separate-effects experiments were developed and performed at Idaho National Laboratory's Transient Reactor Test (TREAT) facility. These experiments employ a heat sink to radially remove heat from the fuel in a manner that approximates the effect of coolant in an operating light-water reactor (LWR). The test holder for these experiments is known as the Dry In-pile Fracture Test (DRIFT). A series of experiments employing DRIFT and TREAT were performed to provide data on the extent and nature of fracture in fresh fuel at various points during a ramp to full power. Novel aspects of these experiments include the way they employ a heat sink to replicate steady-state LWR conditions, as well as the use of fiber optic sensors for in-reactor thermal instrumentation. Details on the development of this experiment, experimental conditions, and resulting data (including in situ thermal measurements and post-irradiation imaging of fracture) are provided in this work. LWR-equivalent powers ranging from 10 to 25 kW/m were tested using this apparatus. Cracking was visible at all power levels, with increasing cracking extent as the power level increased, although there was little difference in the cracking between the two highest-power tests, which had LWR-equivalent powers of 20 and 25 kW/m.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fully Distributed Acoustic and Magnetic Field Monitoring Via a Single Fiber Line for Optimized Production of Unconventional Resource Plays

This is the final technical report for the Virginia Tech Center for Photonics Technology (VT-CPT) research project entitled “Fully Distributed Acoustic and Magnetic Field Monitoring Via a Single Fiber Line for Optimized Production of Unconventional Resource Plays”. In the the four-year effort, VT-CPT collaborated with the Departments of Mathmatics at VT and Sentek Instrument, LLC (Sentek) to develop a fiber-optic sensing system capable of real-time simultaneous distributed measurement of multiple subsurface, drilling, and production parameters. The ultra-sensitive fiber optic distributed acoustic sensing technology, picoDAS, developed by Sentek was integrated with a novel multi-material optical sensing fiber fabricated by CPT-VT to obtain distributed acoustic and magnetic field measurements with ultrahigh sensitivity and high spatial resolution. The sensing technology successfully developed and demonstrated under this research program is truly unique has application beyond subsurface imaging to include carbon storage and electrical grid monitoring, as well as healthcare and nuclear fusion. The project, sponsored by the Advanced Technology Program, began in 2019 and had the original goal of developing the next generation of harsh environment sensing systems. Exhaustive theoretical modeling was performed to optimize the multi-material optical fiber design. VT developed the processing techniques employed to successfully fabricate single mode fibers with metal cladding wires. Sensing fibers with nickel and Metglas cladding wires were fully characterized, inscribed with sensors, and fully integrated with the picoDAS system. Laboratory scale testing was performed to demonstrate performance upon exposure to lateral and transverse magnetic fields. Preliminary field trials were performed for prototype magnetic and acoustic sensing systems upon near surface deployment at VT. The distributed acoustic and magnetic field sensing system was advanced from a (Technology Readiness Level) TRL=2 to a TRL=5 via laboratory scale system validation in relevant environments. The truly one-of-its kind distributed magnetic and acoustic sensing system is expected to find immediate applications that require subsurface monitoring, to include carbon storage site monitoring, and has the potential to be a distributive technology in healthcare and electric grid markets. The technologies developed by Virginia Tech’s Center for Photonics Technology will support the mission of the National Energy Technology Laboratory (NETL) to drive innovation and deliver solutions for an environmentally sustainable and prosperous energy future by ensuring affordable, abundant, and reliable energy that drives a robust economy and national security. Technical accomplishments during the program are summarized briefly here and described in detail in the remainder of the report.

02 PETROLEUM↗

An automated system to define the optimal operating settings of cryogenic calorimeters

Cryogenic macro-calorimeters instrumented with NTD thermistors have been developed for several decades. The choice of the optimal bias current is crucial for a proper operation of these detectors, both in terms of energy resolution and stability. In this paper we present a set of automatic measurements and analysis procedures for the characterization and optimization of the working configuration of the NTD thermistors. The presented procedures were developed for CUORE, an array of 988 cryogenic macro-calorimeters instrumented with NTD thermistors that has been taking data since 2017. These procedures made it possible to characterize a large number of detectors in a reliable way. They are suitable enough to be used also in other large arrays of cryogenic detectors, such as CUPID.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-Particle Soot Photometer (SP2) Black Carbon Number and Mass Concentrations

The single-particle soot photometer (SP2) records particle-by-particle measurements of the intensity of both the scattering signature and incandescence signature of particles that enter its laser beam. These intensities are then used to calculate refractory black carbon (rBC) masses and particle diameters. In previous U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility field campaigns, the SP2 data was difficult to process because the manufacturer-supplied code was not scalable to distributed machines, making it unusable for the large amounts of data output by the SP2. This prohibited the SP2 from becoming an operational instrument for ARM. Therefore, PySP2 was developed to solve this issue and enable SP2 to be an operational instrument for ARM. This technical document summarizes the test data sets from the ARM North Slope of Alaska (NSA) site and the Multidisciplinary Drifting Observatory for the Study of Arctic Climate (MOSAiC) field campaign that were used to develop and test PySP2.

54 ENVIRONMENTAL SCIENCES↗

Reference Hardware and Software Architecture for a Solenoid Pulser for Scientific Instrumentation at the National Ignition Facility

High current, high voltage solenoid pulser power systems for the generation of magnetic fields in a solenoid is not a radical or new concept. Despite being a cornerstone of scientific and weapons research for over 100 years, a commercial off the shelf unit easily configurable for a broad set of applications has yet to appear on the open market. Pulser systems are instead designed for specific target requirements. For gigawatt to terawatt systems, this is unavoidable. For megawatt systems however, many hundreds of thousands of dollars are wasted designing pulser systems from the ground up for clients, when it is possible to simply architect a modular system once that can have its capacitors swapped for many possible target applications. The National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory (LLNL) is one such institution that would benefit from such a system, having bought such pulsers for several imaging systems. Ideally, all such a system would require is only a bachelors-level circuit analysis to find the correct capacitor values, as well as a written procedure to calibrate the software to correctly deliver the voltages required by the application. In this work, systems architecture and software engineering techniques are used to design and analyze such a system. Such a design, it is the hope of this author, will be used in scientific and engineering purposes in the future to build solenoid pulsers at the National Ignition Facility and other institutions to drastically cut development costs of scientific instrumentation.

42 ENGINEERING↗

Ocean Energy for Ocean Worlds

Energy systems generating power from ocean waves, currents, tides, and thermal and salinity gradients are being developed to power oceanographic instrumentation and autonomous vehicles in Earth’s oceans. Exploration missions enabled or extended with in-situ energy harvesting on Earth may be similar to those on extra-terrestrial ocean worlds including mapping, biogeochemical sampling, acoustic monitoring, search for building blocks of life, and physical oceanographic characterization. With the addition of ocean energy available at the point of observation, data can be collected on larger spatial and temporal scales, enabling more comprehensive missions on other worlds. Power resource characteristics (e.g. current speed, variability) will similarly need to be assessed. Earth and extra-terrestrial ocean missions share vast technical challenges including high expense, need for advanced autonomy, ability to survive in the harshest environments, and limited communications or opportunities for intervention. Marine energy systems may be the only option for in-situ generation in certain scenarios (e.g., under a thick layer of ice) or advantageous over onboard energy storage options that may interfere with the natural environment (e.g., radioisotope thermoelectric generators). This work provides an overview of existing marine energy technology pertaining to ocean observations, highlights emerging research and development and new funding and program initiatives, explores similarities in mission requirements between terrestrial and extra-terrestrial applications, and suggests innovation pathways towards enabling high-value ocean world exploration powered by ocean energy.

Cavagnaro, Robert J.↗

Advancing Li-plating detection: Motivating a multi-signal correlation approach

Facilitating fast charging in lithium-ion batteries (LiBs) is often linked to Li-plating, which harms performance, longevity, and safety. Early detection of Li-plating is essential for rapid technological development and for preventing performance deterioration and ensuring safety during operation. Fast and real-time detection, using commonly collected measurements like voltage (V), current (I), temperature (T), and pressure (P), is highly desirable. Existing standalone methods relying on electrochemical and mechanical signatures, using half, smaller, or specially designed cells often operated at lower temperatures, fail to account for real-world fast-charging conditions. These signatures may also have inherent unreliability in aged LiBs, a phenomenon currently not-well understood. All these uncertainties have complicated practical implementation of a robust Li-plating detection technique. This study, through multiple case studies involving real-world fast-charging conditions using automotive-grade 11.6 Ah LiBs, shows that many single signal-based diagnostic techniques may be inadequate to detect Li-plating. Among various signatures, end-of-charge rest pressure, differential pressure-sensing, and end-of-charge rest voltage were identified as particularly useful in detecting Li-plating. Furthermore, A multi-signal-based detection technique is shown to be more robust in detecting Li-plating. Using both fresh and aged cells, the results and analysis highlight how detection capabilities are influenced by various factors, including battery design, size, charging speed, operating temperature, and degradation level. Adopting such a multi-signal Li-plating detection approach may be instrumental in the rapid development of battery technology in laboratories, as well as ensuring the enhanced safety of next-generation LiBs in real-world fast-charging applications.

25 ENERGY STORAGE↗

Cross-Facility Orchestration of Electrochemistry Experiments and Computations

Instrument-computing ecosystems supporting automated electrochemical workflows typically require the integration of disparate instruments such as syringe pump, fraction collector, and potentiostat, all connected to an electrochemical cell. These specialized instruments with custom software and interfaces are not typically designed for network integration and remote automation. We developed a networked ecosystem of these instruments and computing platforms, which includes software to enable automated workflow orchestration from remote computers. Specifically, we developed Python wrappers of APIs and custom Pyro client-server modules to support remote operation of these instruments over the ecosystem network. Herein, we describe a specific workflow for generating and validating voltammogram (I-V) measurements of an electrolyte solution pumped into the electrochemical cell. We demonstrate the orchestration of this workflow which is composed using a Jupyter notebook and executed on a remote computer.

Al Najjar, Anees↗

A Custom High-Throughput Optical Mapping Instrument (OMI) for Accelerated Stress Testing of PV Module Materials

The performance and integrity of photovoltaic (PV) modules and materials may be assessed through optical characterizations. We have developed a custom Optical Mapping Instrument (OMI) to improve measurement throughput time, facilitate automated measurements, and obtain spatial information relative to commercial benchtop spectrophotometer instruments. Both the key components and the methods used to improve the measurements are described. The measurement precision for the OMI is benchmarked for hemispherical transmittance relative to a previous round-robin study for commercial spectrophotometers. Example mapping measurements and their implications are given for specimens from other studies, including: (1) the depletion of the UV absorber is revealed for specimens beyond a certain size after standardized artificial ultraviolet (UV) weathering, (2) an optical degradation by internal haze formation is confirmed following Damp Heat (85°C/85% relative humidity) testing, (3) the better uniformity of the wear pattern for falling sand abrasion is used to select the DIN 52348 fixture over the ASTM D968 fixture, and (4) the local (millimeter-scale) heterogeneity of surface contamination in the soiling-prone location of Dubai relative to Kuwait. The results of the UV study have already been used to improve the standardized weathering of encapsulants. The example for Damp Heat testing is given to increase awareness of a degradation believed to be ubiquitously occurring in safety and design-type qualification testing of PV modules.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Characterization of SimulCam, a standoff Raman system for scientific support of SuperCam operations on Mars

During the development activities of SuperCam Calibration Target, target intended for one of the two first Raman instruments to be deployed on another planetary body, our group developed a laboratory instrument that could simulate to some extent the Raman capabilities of one of such instruments and could provide data with similar quality. The use of this kind of laboratory instruments has demonstrated its utility in the evaluation of potential calibration targets or anticipating the science outcome that an instrument could provide. The present work describes our laboratory setup to support SuperCam, evaluating similarities between both instruments, despite of differences in the hardware. Evaluation of data gathered by SuperCam on Mars and the availability of one replica of SuperCam’s Calibration Target allowed the comparison on the same set of targets, demonstrating how similar Signal-to-Noise Ratio (SNR) could be achieved from both instruments. The higher energy per pulse on SimulCam is compensated by a greater analytical footprint and the use of smaller collection optics. The results show how spectra obtained at representative distances of SuperCam are comparable. Operational principles are also comparable in terms of time resolution, and close in terms of spectral resolution. This similarity has allowed different science support works using SimulCam data, as well as the support to Mars detections using our setup. We provide examples of this support that will be shared with the community in different papers, as well as examples of possible operations activities that could benefit from experiments performed with SimulCam. We show how this setup can complement the two laboratory replicas in Los Alamos and Toulouse in providing support data to different experiments.

47 OTHER INSTRUMENTATION↗

The development of a 6 Li-based pixelated neutron detector for neutron reflectometry at the Spallation Neutron Source

We present a high-rate 6 Li-based pixelated neutron detector developed for neutron reflectometry instruments at the Spallation Neutron Source (SNS). The neutron detector has a pixelated design: each 6 Li scintillator element has its own photosensor and independent channel readout. This paper focuses on the general overview of the detector design and construction, the characterization of the pixelated detector, and the results of the first neutron reflectivity experiments conducted using the pixelated neutron detector at the SNS Liquid Reflectometer (BL-4B). The pixelated neutron detector demonstrated a global time-average count rate of ≥ 1.8 x 10 6 cps, at least 3 orders of magnitude higher than that of the existing neutron detector ( 3 He-based Multi-Wire Proportional Counter), and a local instantaneous count rate of ≥ 1.73 x 10 6 cps / cm 2 . The maximum counting rate of the detector has not yet been determined as the detector is capable of handling the maximum flux available at the beamline. Furthermore, the outcome of the neutron reflectivity experiments showed that the pixelated neutron detector is a promising candidate for next-generation neutron reflectometry instruments at the SNS.

6Li, silicon photomultiplier↗

Tandem Mass-Selective Cryogenic Digital Ion Traps for Enhanced Cluster Formation

We present the implementation of tandem mass-selective cryogenic ion traps, designed to enhance the range of ion processing capabilities that can be performed prior to spectroscopic interrogation. We show that both the formation of ion clusters and mass filtering steps can be combined in a single cryogenic linear quadrupole ion trap driven by RF square waves. Mass filtering and mass isolation can be achieved by manipulation of the RF frequency and duty cycle. Very importantly, this scheme circumvents the need for high-amplitude RF voltages that can be incompatible with typical cryogenic ion processing conditions. In addition, proper adjustment of the stability boundaries during the clustering process allows for the preferential formation of a specific cluster size rather than a broad distribution of sizes. Lastly, we show that a specific cluster size can be formed, mass-selected, and then transferred to another ion trap for a second completely separate ion processing step. Furthermore, the instrumentation and modular design developed here expand the scope of ionic species and clusters that can be accessed by processing electrosprayed ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray Photoelectron Spectroscopy Analysis of Nafion-Containing Samples: Pitfalls, Protocols, and Perceptions of Physicochemical Properties

X-ray photoelectron spectroscopy (XPS) is one of the most common techniques used to analyze the surface composition of catalysts and support materials used in polymer electrolyte membrane (PEM) fuel cells and electrolyzers, providing important insights for further improvement of their properties. Characterization of catalyst layers (CLs) is more challenging, which can be at least partially attributed to the instability of ionomer materials such as Nafion during measurements. This work explores the stability of Nafion during XPS measurements, illuminating and addressing Nafion degradation concerns. The extent of Nafion damage as a function of XPS instrumentation, measurement conditions, and sample properties was evaluated across multiple instruments. Results revealed that significant Nafion damage to the ion-conducting sulfonic acid species (>50% loss in sulfur signal) may occur in a relatively short time frame (tens of minutes) depending on the exact nature of the sample and XPS instrument. This motivated the development and validation of a multipoint XPS data acquisition protocol that minimizes Nafion damage, resulting in reliable data acquisition by avoiding significant artifacts from Nafion instability. The developed protocol was then used to analyze both thin film ionomer samples and Pt/C-based CLs. Comparison of PEM fuel cell CLs to Nafion thin films revealed several changes in Nafion spectral features attributed to charge transfer due to interaction with conductive catalyst and support species. This study provides a method to reliably characterize ionomer-containing samples, facilitating fundamental studies of the catalyst-ionomer interface and more applied investigations of structure-processing-performance correlations in PEM fuel cell and electrolyzer CLs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Achievements and Prospects of Global Broadband Seismographic Networks After 30 Years of Continuous Geophysical Observations

Global seismographic networks (GSNs) emerged during the late nineteenth and early twentieth centuries, facilitated by seminal international developments in theory, technology, instrumentation, and data exchange. The mid- to late-twentieth century saw the creation of the World-Wide Standardized Seismographic Network (1961) and International Deployment of Accelerometers (1976), which advanced global geographic coverage as seismometer bandwidth increased greatly allowing for the recording of the Earth's principal seismic spectrum. The modern era of global observations and rapid data access began during the 1980s, and notably included the inception of the GEOSCOPE initiative (1982) and GSN (1988). Through continual improvements, GEOSCOPE and the GSN have realized near-real time recording of ground motion with state-of-art data quality, dynamic range, and timing precision to encompass 180 seismic stations, many in very remote locations. Data from GSNs are increasingly integrated with other geophysical data (e.g., space geodesy, infrasound and Interferometric Synthetic Aperture Radar). Globally distributed seismic data are critical to resolving crust, mantle, and core structure; illuminating features of the plate tectonic and mantle convection system; rapid characterization of earthquakes; identification of potential tsunamis; global nuclear test verification; and provide sensitive proxies for environmental changes. As the global geosciences community continues to advance our understanding of Earth structure and processes controlling elastic wave propagation, GSN infrastructure offers a springboard to realize increasingly multi-instrument geophysical observatories. Here, we review the historical, scientific, and monitoring heritage of GSNs, summarize key discoveries, and discuss future associated opportunities for Earth Science.

58 GEOSCIENCES↗

X-Ray Imaging and Spectroscopy Mission

The X-Ray Imaging and Spectroscopy Mission (XRISM) is a joint mission between the Japan Aerospace Exploration Agency (JAXA) and the National Aeronautics and Space Administration (NASA) in collaboration with the European Space Agency (ESA). In addition to the three space agencies, universities and research institutes from Japan, North America, and Europe have joined to contribute to developing satellite and onboard instruments, data-processing software, and the scientific observation program. XRISM is the successor to the ASTRO-H (Hitomi) mission, which ended prematurely in 2016. Its primary science goal is to examine astrophysical problems with precise, high-resolution X-ray spectroscopy. XRISM promises to discover new horizons in X-ray astronomy. It carries a 6 × 6 pixelized X-ray microcalorimeter on the focal plane of an X-ray mirror assembly (Resolve) and a co-aligned X-ray CCD camera (Xtend) that covers the same energy band over a large field of view. XRISM utilizes the Hitomi heritage, but all designs were reviewed. The attitude and orbit control system was improved in hardware and software. The spacecraft was launched from the JAXA Tanegashima Space Center on 2023 September 6 (UTC). During the in-orbit commissioning phase, the onboard components were activated. Although the gate valve protecting the Resolve sensor with a thin beryllium X-ray entrance window was not yet opened, scientific observation started in 2024 February with the planned performance verification observation program. The nominal observation program commenced with the following guest observation program beginning in 2024 September.

Astronomy and AstroPhysics↗

Optimization of X-ray event screening using ground and in-orbit data for the Resolve instrument onboard the XRISM satellite

The X-Ray Imaging and Spectroscopy Mission (XRISM) satellite was successfully launched and put into a low-Earth orbit on September 6, 2023 (UT). The Resolve instrument onboard XRISM hosts an X-ray microcalorimeter detector, which was designed to achieve a high-resolution ( ≤ 7 eV FWHM at 6 keV), high-throughput, and non-dispersive spectroscopy over a wide energy range. It also excels in a low background with a requirement of < 2 × 10 -3 s -1 keV -1 (0.3 to 12.0 keV), which is equivalent to only one background event per spectral bin per 100-ks exposure. Event screening to discriminate X-ray events from background is a key to meeting the requirement. We present the result of the Resolve event screening using data sets recorded on the ground and in orbit based on the heritage of the preceding X-ray microcalorimeter missions, in particular, the Soft X-ray Spectrometer onboard ASTRO-H. We optimize and evaluate 19 screening items of three types based on (1) the event pulse shape, (2) relative arrival times among multiple events, and (3) good time intervals. We show that the initial screening, which is applied for science data products in the performance verification phase, reduces the background rate to 1.8 × 10 -3 s -1 keV -1 meeting the requirement. We further evaluate the additional screening utilizing the correlation among some pulse shape properties of X-ray events and show that it further reduces the background rate, particularly in the < 2 keV band. Over 0.3 to 12 keV, the background rate becomes 1.0 × 10 -3 s -1 keV -1 .

47 OTHER INSTRUMENTATION↗

Are Atmospheric Models Too Cold in the Mountains? The State of Science and Insights from the SAIL Field Campaign

Mountains play an outsized role in water resource availability, and the amount and timing of water they provide depend strongly on temperature. To that end, we ask the question: How well are atmospheric models capturing mountain temperatures? We synthesize results showing that high-resolution, regionally relevant climate models produce 2-m air temperature (T2m) measurements colder than what is observed (a “cold bias”), particularly in snow-covered midlatitude mountain ranges during winter. We find common cold biases in 44 studies across global mountain ranges, including single-model and multimodel ensembles. We explore the factors driving these biases and examine the physical mechanisms, data limitations, and observational uncertainties behind T2m. Our analysis suggests that the biases are genuine and not due to observation sparsity or resolution mismatches. Cold biases occur primarily on mountain peaks and ridges, whereas valleys are often warm biased. Our literature review suggests that increasing model resolution does not clearly mitigate the bias. By analyzing data from the Surface Atmosphere Integrated Field Laboratory (SAIL) field campaign in the Colorado Rocky Mountains, we test various hypotheses related to cold biases and find that local wind circulations, longwave (LW) radiation, and surface-layer parameterizations contribute to the T2m biases in this particular location. We conclude by emphasizing the value of coordinated model evaluation and development efforts in heavily instrumented mountain locations for addressing the root cause(s) of T2m biases and improving predictive understanding of mountain climates.

54 ENVIRONMENTAL SCIENCES↗

Are Atmospheric Models Too Cold in the Mountains? The State of Science and Insights from the SAIL Field Campaign

Mountains play an outsized role in water resource availability, and the amount and timing of water they provide depend strongly on temperature. To that end, we ask the question: How well are atmospheric models capturing mountain temperatures? We synthesize results showing that high-resolution, regionally relevant climate models produce 2-m air temperature (T2m) measurements colder than what is observed (a “cold bias”), particularly in snow-covered midlatitude mountain ranges during winter. We find common cold biases in 44 studies across global mountain ranges, including single-model and multimodel ensembles. We explore the factors driving these biases and examine the physical mechanisms, data limitations, and observational uncertainties behind T2m. Our analysis suggests that the biases are genuine and not due to observation sparsity or resolution mismatches. Cold biases occur primarily on mountain peaks and ridges, whereas valleys are often warm biased. Our literature review suggests that increasing model resolution does not clearly mitigate the bias. By analyzing data from the Surface Atmosphere Integrated Field Laboratory (SAIL) field campaign in the Colorado Rocky Mountains, we test various hypotheses related to cold biases and find that local wind circulations, longwave (LW) radiation, and surface-layer parameterizations contribute to the T2m biases in this particular location. We conclude by emphasizing the value of coordinated model evaluation and development efforts in heavily instrumented mountain locations for addressing the root cause(s) of T2m biases and improving predictive understanding of mountain climates.

54 ENVIRONMENTAL SCIENCES↗