A Fast Radio Burst Backend for the Tianlai Dish Pathfinder Array

The Tianlai Dish Pathfinder Array is a radio interferometer array consisting of 16 six-meter dish antennas. The original digital backend integration time is at the seconds level, designed for H I intensity mapping experiment. A new digital backend with millisecond response is added to enable it to search for fast radio burst during its observations. The design and calibration of this backend, and the real time search pipeline for it are described in this paper. It is capable of forming 16 digital beams for each linear polarization, covering an area of 19.6 square degrees. The search pipeline is capable of searching for, recording and classifying FRBs automatically in real time. Finally, in commissioning, we succeeded in capturing the signal pulses from the pulsars PSR B0329+54 and B2021+51.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of Fabry-perot Spectrometers for Measurement of Upper Atmosphere Temperatures and Winds

The mechanisms giving rise to certain airglow and auroral emissions and their height distribution are briefly surveyed. The basic principles of operation of scanning Fabry-Perot spectrometers are outlined in order to illustrate the calibration and use of such instruments to measure Doppler broadening and shift of atomic emission lines in the spectrum of the airglow and aurora and hence to infer atmospheric temperatures and wind velocities. Technical details of some specific instruments are given. Brief mention is made of the use of wide angle Michelson interferometers for the same application. Emphasis is given to the future importance of imaging Fabry-Perot spectrometers to permit the detailed mapping of temperature and wind velocity, especially in the auroral regions.

F Jacka↗

The Wide-Field Spatio-Spectral Interferometer: System Overview, Data Synthesis and Analysis

The Wide-field Imaging Interferometry Testbed (WIIT) is a double Fourier (DF) interferometer operating at optical wavelengths, and provides data that are highly representative of those from a space-based far-infrared interferometer like SPIRIT. We have used the testbed to observe both geometrically simple and astronomically representative test scenes. Here we present an overview of the astronomical importance of high angular resolution at the far infrared, followed by the description of the optical set-up of WIIT, including the source simulator CHIP (Calibrated Hyperspectral Image Projector). We describe our synthesis algorithms used in the reconstruction of the input test scenes via a simulation of the most recent measurements. The updated algorithms, which include instruments artifacts that allow the synthesis of DF experimental data, are presented and the most recent results analyzed.

Juanola-Parramon, Roser↗

Three component laser anemometer measurements in an annular cascade of core turbine vanes with contoured end wall

The three mean velocity components were measured in a full-scale annular turbine stator cascade with contoured hub end wall using a newly developed laser anemometer system. The anemometer consists of a standard fringe configuration using fluorescent seed particles to measure the axial and tangential components. The radial component is measured with a scanning confocal Fabry-Perot interferometer. These two configurations are combined in a single optical system that can operate simultaneously in a backscatter mode through a single optical access port. Experimental measurements were obtained both within and downstream of the stator vane row and compared with calculations from a three-dimensional inviscid computer program. In addition, detailed calibration procedures are described that were used, prior to the experiment, to accurately determine the laser beam probe volume location relative to the cascade hardware.

Goldman, Louis J.↗

A very-long-baseline interferometer system for geodetic applications

A very-long-baseline interferometer system was designed and built for geodetic applications. Each interferometer terminal records a 360-kHz spectral band of noise from a compact extragalactic radio source. The center frequency of the spectral band can be selected to sample sequentially bands covering a much wider frequency range to obtain subnanosecond accuracy in group-delay measurements. A tunnel-diode pulse generator is used to calibrate the delays in the receiver. The necessary sets of algorithms and computer programs have been developed to analyze the data and have allowed the system to be employed to make accurate determinations of vector baselines, radio-source positions, polar motion, and universal time.

Whitney, A. R.↗

Very-high-resolution far-infrared measurements of atmospheric emission from aircraft

Instrument problems and technical results are discussed for an experiment in which an absolute spectrometric radiometer was flown aboard a NASA aircraft at altitudes of 33,000 to 41,000 ft to measure atmospheric emission in the spectral range from 5 to 40 kaysers with a resolution of about 0.03 kayser apodized. The instrument used was actually a polarizing interferometer, and the atmosphere was observed at fixed zenith angles constant to within plus or minus 0.1 deg. The only problem noted was the spoilage of some interferograms by spikes due to electrical interference from the aircraft radio transmission system. A spectrum of the atmospheric-emission brightness temperature obtained with real-time calibration is examined, and the spectral resolution, S/N ratio, and total instrument efficiency are evaluated. The experimental S/N ratio is estimated to be between 40 and 100.

Carli, B.↗

Improved Analysis of GW150914 Using a Fully Spin-Precessing Waveform Model

This paper presents updated estimates of source parameters for GW150914, a binary black-hole coalescence event detected by the Laser Interferometer Gravitational-wave Observatory (LIGO) in 2015 [Abbott et al. Phys. Rev. Lett. 116, 061102 (2016).]. Abbott et al. [Phys. Rev. Lett. 116, 241102 (2016).] presented parameter estimation of the source using a 13-dimensional, phenomenological precessing-spin model (precessing IMRPhenom) and an 11-dimensional nonprecessing effective-one-body (EOB) model calibrated to numerical-relativity simulations, which forces spin alignment (nonprecessing EOBNR). Here, we present new results that include a 15-dimensional precessing-spin waveform model (precessing EOBNR) developed within the EOB formalism. We find good agreement with the parameters estimated previously [Abbott et al. Phys. Rev. Lett. 116, 241102 (2016).], and we quote updated component masses of 35(+5)(-3) solar M; and 30(+3)(-4) solar M; (where errors correspond to 90 symmetric credible intervals). We also present slightly tighter constraints on the dimensionless spin magnitudes of the two black holes, with a primary spin estimate is less than 0.65 and a secondary spin estimate is less than 0.75 at 90% probability. Abbott et al. [Phys. Rev. Lett. 116, 241102 (2016).] estimated the systematic parameter-extraction errors due to waveform-model uncertainty by combining the posterior probability densities of precessing IMRPhenom and nonprecessing EOBNR. Here, we find that the two precessing-spin models are in closer agreement, suggesting that these systematic errors are smaller than previously quoted.

Abbott, B. P.↗

Helium Cryo Testing of a SLMS(TM) (Silicon Lightweight Mirrors) Athermal Optical Assembly

SLMS (TM) a thermal technology has been demonstrated in the small 4-foot helium cryogenic test chamber located at the NASA/MSFC X-Ray Calibration Facility (XRCF). A SLMS (TM) Ultraviolet Demonstrator Mirror (UVDM) produced by Schafer under a NASA/MSFC Phase I SBIR was helium cryo tested both free standing and bonded to a Schafer designed prototype carbon fiber reinforced silicon carbide (Cesic) mount. Surface figure data was obtained with a test measurement system that featured an Instantaneous Phase Interferometer (IPI) by ADE Phase Shift. The test measurement system s minimum resolvable differential figure deformation and possible contributions from test chamber ambient to cryo window deformation are under investigation. The free standing results showed differential figure deformation of 10.4 nm rms from 295K to 27K and 3.9 nm rms after one cryo cycle. The surface figure of the UVDM degraded by lambda/70 rms HeNe once it was bonded to the prototype Cesic mount. The change was due to a small astigmatic aberration in the rototype Cesic mount due to lack of finish machining and not the bonding technique. This effect was seen in SLMST (TM) optical assembly results, which showed differential figure deformation of 46.5 nm rms from 294K to 27K, 42.9 nm rms from 294K to 77K, 28.0 nm rms from 294K to 193K and 6.2 nm rms after one cryo cycle.

Jacoby, Marc T.↗

NASA Tech Briefs, June 2011

Topics covered include: Wind and Temperature Spectrometry of the Upper Atmosphere in Low-Earth Orbit; Health Monitor for Multitasking, Safety-Critical, Real-Time Software; Stereo Imaging Miniature Endoscope; Early Oscillation Detection Technique for Hybrid DC/DC Converters; Parallel Wavefront Analysis for a 4D Interferometer; Schottky Heterodyne Receivers With Full Waveguide Bandwidth; Carbon Nanofiber-Based, High-Frequency, High-Q, Miniaturized Mechanical Resonators; Ultracapacitor-Based Uninterrupted Power Supply System; Coaxial Cables for Martian Extreme Temperature Environments; Using Spare Logic Resources To Create Dynamic Test Points; Autonomous Coordination of Science Observations Using Multiple Spacecraft; Autonomous Phase Retrieval Calibration; EOS MLS Level 1B Data Processing Software, Version 3; Cassini Tour Atlas Automated Generation; Software Development Standard Processes (SDSP); Graphite Composite Panel Polishing Fixture; Material Gradients in Oxygen System Components Improve Safety; Ridge Waveguide Structures in Magnesium-Doped Lithium Niobate; Modifying Matrix Materials to Increase Wetting and Adhesion; Lightweight Magnetic Cooler With a Reversible Circulator; The Invasive Species Forecasting System; Method for Cleanly and Precisely Breaking Off a Rock Core Using a Radial Compressive Force; Praying Mantis Bending Core Breakoff and Retention Mechanism; Scoring Dawg Core Breakoff and Retention Mechanism; Rolling-Tooth Core Breakoff and Retention Mechanism; Vibration Isolation and Stabilization System for Spacecraft Exercise Treadmill Devices; Microgravity-Enhanced Stem Cell Selection; Diagnosis and Treatment of Neurological Disorders by Millimeter-Wave Stimulation; Passive Vaporizing Heat Sink; Remote Sensing and Quantization of Analog Sensors; Phase Retrieval for Radio Telescope and Antenna Control; Helium-Cooled Black Shroud for Subscale Cryogenic Testing; Receive Mode Analysis and Design of Microstrip Reflectarrays; and Chance-Constrained Guidance With Non-Convex Constraints.

Source record↗

Throughput of the Composite Infrared Spectrometer (CIRS) Mid Infrared (MIR) Channel for the Cassini Mission to Saturn

The Composite Infrared Spectrometer (CIRS) of the Cassini mission to Saturn has two interferometers covering the far infrared and mid infrared wavelength region. The instrument was aligned at ambient temperature, but operates at 170 Kelvin and has challenging interferometric alignment tolerances. Cryogenic alignment tests of the instrument indicate that it should suffer minimal degradation due to the cooldown from ambient to operational temperature. System level tests performed by the calibration team indicated a lower than expected signal level on the MIR channel, while providing ambiguous optical throughput data. Therefore it became imperative to develop a metric that could be used to determine the instrument performance at both the instrument and system levels, at ambient and cryogenic temperature. Modulation efficiency and throughput measurements were performed and new analytical models developed to evaluate the status of the instrument. Empirical and analytical data were eventually reconciled and deviations from the design values explained.

Hagopian, John G.↗

Phase-Shifting Liquid Crystal Point-Diffraction Interferometry

Microgravity fluid physics experiments frequently measure concentration and temperature. Interferometers such as the Twyman Green illustrated have performed full-field measurement of these quantities. As with most such devices, this interferometer uses a reference path that is not common with the path through the test section. Recombination of the test and reference wavefronts produces interference fringes. Unfortunately, in order to obtain stable fringes, the alignment of both the test and reference paths must be maintained to within a fraction of the wavelength of the light being used for the measurement. Otherwise, the fringes will shift and may disappear. Because these interferometers are extremely sensitive to bumping, jarring and transmitted vibration, they are typically mounted on optical isolation tables. Schlieren deflectometers or the more recent Shack-Hartmann wavefront sensors also measure concentration and temperature in laboratory fluid flows. Ray optics describe the operation of both devices. In a schlieren system, an expanded, collimated beam passes through a test section where refractive index gradients deflect rays. A lens focuses the beam to a filter placed in the rear focal plane of the decollimating lens. In a quantitative color schlieren system, gradients in the index of refraction appear as colors in the field of view due to the action of the color filter. Since sensitivity is a function of the focal length of the decollimating lens, these systems are rather long and filter fabrication and calibration is rather difficult. A Shack-Hartmann wavefront sensor is an array of small lenslets. Typical diameters are on the order of a few hundred microns. Since these lenslets divide the test section into resolution elements, the spatial resolution can be no smaller than an individual lenslet. Such a device was recently used to perform high-speed tomography of heated air exiting a 1.27 cm diameter nozzle. While these wavefront sensors are very compact, the limited spatial resolution and the methods required for data reduction suggest that a more useful instrument needs to be developed. The category of interferometers known as common path interferometers can eliminate much of the vibration sensitivity associated with traditional interferometry as described above. In these devices, division of the amplitude of the wavefront following the test section produces the reference beam. Examples of these instruments include shearing and point diffraction interferometers. In the latter case, shown schematically, a lens focuses light passing through the test section onto a small diffracting object. Such objects are typically either a circle of material on a high quality glass plate or a small sphere in a glass cell. The size of the focused spot is several times larger than the object so that the light not intercepted by the diffracting object forms the test beam while the diffracted light generates a spherical reference beam. While this configuration is mechanically stable, phase shifting one beam with respect to the other is difficult due to the common path. Phase shifting enables extremely accurate measurements of the phase of the interferogram using only gray scale intensity measurements and is the de facto standard of industry. Mercer and Creath 2 demonstrated phase shifting in a point diffraction interferometer using a spherical spacer in a liquid crystal cell as the diffracting object. By changing the voltage across the cell, they were able to shift the phase of the undiffracted beam relative to the reference beam generated by diffraction from the sphere. While they applied this technology to fluid measurements, the device shifted phase so slowly that it was not useful for studying transient phenomena. We have identified several technical problems that precluded operation of the device at video frame rates and intend to solve them to produce a phase-shifting liquid crystal point-diffraction interferometer operating at video frame rates. The first task is to produce high contrast fringes. Since the diffracted beam is much weaker than the transmitted beam, interferograms have poor contrast unless a dye is added to the liquid crystal to reduce the intensity of the undiffracted light. Dyes previously used were not rigorously characterized and suffered from hysteresis in both the initial alignment state of the device and the electro-optic switching characteristics. Hence, our initial effort will identify and characterize dyes that do not suffer from these difficulties and are readily soluble in the liquid crystal host. Since the ultimate goal of this research is to produce interferometers capable of phase shifting at video frame rates, we will quantify the difference in switching times between ferroelectric and nematic liquid crystals. While we have more experience with nematic crystals, they typically switch more slowly than ferroelectric cells. As part of that effort, we will investigate the difference in the modulation of the interferograms as a function of the type of liquid crystal in the cell. Because the temporal switching response of a liquid crystal cell is directly related its thickness, we intend to explore techniques required to produce cells that are as thin as possible. However, the cells must still produce a total phase shift of two pi radians.

Griffin, DeVon W.↗

21 cm Power Spectrum Analysis of North Celestial Pole Observations with the Tianlai Dish Pathfinder Array

The Tianlai Dish Pathfinder Array (TDPA) is a radio interferometer designed to test techniques for 21 cm intensity mapping in the post-reionization Universe as a means of measuring large-scale cosmic structure. Using nine nights of observations targeting the North Celestial Pole field, totaling approximately 107 hr of integration time, we analyze data in the frequency range 700–800 MHz (corresponding to redshift z ∼ 0.9). We do the data format conversion, radio frequency interference flagging, calibration, imaging and point source subtraction, and foreground removal via Singular Value Decomposition. The spherically averaged power spectrum Δ 2 (k) is obtained. Furthermore, this work successfully establishes and validates a comprehensive data analysis framework for the TDPA. We identify key improvements including sky model refinement, increased integration time, and pipeline optimization that will enable future detection of the 21 cm signal through auto-correlation and cross-correlation with optical galaxy surveys.

cosmology: large-scale structure of universe↗

A new fast two-color interferometer at Alcator C-Mod for turbulence measurements and comparison with phase contrast imaging

Accurately predicting the turbulent transport properties of magnetically confined plasmas is a major challenge of fusion energy research. Validation of transport models is typically done by applying so-called “synthetic diagnostics” to the output of nonlinear gyrokinetic simulations, and the results are compared to experimental data. As part of the validation process, comparing two independent turbulence measurements to each other provides the opportunity to test the synthetic diagnostics themselves; a step which is rarely possible due to limited availability of redundant fluctuation measurements on magnetic confinement experiments. At Alcator C-Mod, phase-contrast imaging (PCI) is a commonly used turbulence diagnostic. PCI measures line-integrated electron density fluctuations with high sensitivity and wavenumber resolution (1.6 cm{sup −1}≲|k{sub R}|≲11 cm{sup −1}). A new fast two-color interferometry (FTCI) diagnostic on the Alcator C-Mod tokamak measures long-wavelength (|k{sub R}|≲3.0 cm{sup −1}) line-integrated electron density fluctuations. Measurements of coherent and broadband fluctuations made by PCI and FTCI are compared here for the first time. Good quantitative agreement is found between the two measurements. This provides experimental validation of the low-wavenumber region of the PCI calibration, and also helps validate the low-wavenumber portions of the synthetic PCI diagnostic that has been used in gyrokinetic model validation work in the past. We discuss possibilities to upgrade FTCI, so that a similar comparison could be done at higher wavenumbers in the future.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intercomparison of MAS, AVIRIS, and HIS data from FIRE cirrus 2

The NASA ER-2 flight on 5 Dec. 1991 is unique among the FIRE Cirrus 2 missions in that data were acquired simultaneously by the MODIS Airborne Simulator (MAS), the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), and the High Resolution Interferometer Sounder (HIS). These data represent a unique source of information about the spatial and spectral properties of cirrus clouds. The MAS is a new instrument which will aid in defining algorithms and building an understanding of the ability of the Moderate Resolution Imaging Spectroradiometer (MODIS) to remotely sense atmospheric conditions for assessing global change. In order to establish confidence in the absolute calibration accuracy of the MAS radiances, an inter-comparison of MAS radiances with AVIRIS and HIS has been undertaken.

Gumley, Liam E.↗

Method for Accurately Calibrating a Spectrometer Using Broadband Light

A novel method has been developed for performing very fine calibration of a spectrometer. This process is particularly useful for modern miniature charge-coupled device (CCD) spectrometers where a typical factory wavelength calibration has been performed and a finer, more accurate calibration is desired. Typically, the factory calibration is done with a spectral line source that generates light at known wavelengths, allowing specific pixels in the CCD array to be assigned wavelength values. This method is good to about 1 nm across the spectrometer s wavelength range. This new method appears to be accurate to about 0.1 nm, a factor of ten improvement. White light is passed through an unbalanced Michelson interferometer, producing an optical signal with significant spectral variation. A simple theory can be developed to describe this spectral pattern, so by comparing the actual spectrometer output against this predicted pattern, errors in the wavelength assignment made by the spectrometer can be determined.

Simmons, Stephen↗

The MIPAS balloon borne trace constitutent experiment

A novel cryogenic Fourier transform spectrometer (FTS) has been developed for limb emission measurements in the mid IR-region from balloon-borne platforms. The FTS is a rapid scanning interferometer using a modified Michelson arrangement which allows a spectral resolution of 0.04 cm(exp -1) to be achieved. Solid carbon-dioxide cooling of the spectrometer and liquid-helium cooling of the detectors provide adequate sensitivity. The line of sight can be stabilized in terms of azimuth and elevation. A three-mirror off-axis telescope provides good vertical resolution and straylight rejection. Calibration is performed by high elevation and internal blackbody measurements. Four balloon flights were performed, two of them during spring turn-around 1989 and 1990 over mid-latitudes (Aire sur L'Adour, France, 44 deg N) and two near the northern polar circle in winter 1992 (Esrange, Sweden, 68 deg N). Limb emission spectra were collected from 32 km to 39 km floating altitudes covering tangent heights between the lower troposphere and the floating altitude. The trace gases CO2, H2O, O3, CH4, N2O, HNO3, N2O5, ClONO2, CF2Cl2, CFCl3, CHF2Cl, CCl4, and C2H6 have been identified in the measured spectra. The 1989 data have been analyzed to retrieve profiles of O3, HNO3, CFCl3 and CF2Cl2. The flights over Kiruna have provided the first ever reported profile measurements of the key reservoir species ClONO2 and N2O5 inside the polar vortex.

Oelhaf, H.↗

Measurement Via Optical Near-Nulling and Subaperture Stitching

A subaperture stitching interferometer system provides near-nulling of a subaperture wavefront reflected from an object of interest over a portion of a surface of the object. A variable optical element located in the radiation path adjustably provides near-nulling to facilitate stitching of subaperture interferograms, creating an interferogram representative of the entire surface of interest. This enables testing of aspheric surfaces without null optics customized for each surface prescription. The surface shapes of objects such as lenses and other precision components are often measured with interferometry. However, interferometers have a limited capture range, and thus the test wavefront cannot be too different from the reference or the interference cannot be analyzed. Furthermore, the performance of the interferometer is usually best when the test and reference wavefronts are nearly identical (referred to as a null condition). Thus, it is necessary when performing such measurements to correct for known variations in shape to ensure that unintended variations are within the capture range of the interferometer and accurately measured. This invention is a system for nearnulling within a subaperture stitching interferometer, although in principle, the concept can be employed by wavefront measuring gauges other than interferometers. The system employs a light source for providing coherent radiation of a subaperture extent. An object of interest is placed to modify the radiation (e.g., to reflect or pass the radiation), and a variable optical element is located to interact with, and nearly null, the affected radiation. A detector or imaging device is situated to obtain interference patterns in the modified radiation. Multiple subaperture interferograms are taken and are stitched, or joined, to provide an interferogram representative of the entire surface of the object of interest. The primary aspect of the invention is the use of adjustable corrective optics in the context of subaperture stitching near-nulling interferometry, wherein a complex surface is analyzed via multiple, separate, overlapping interferograms. For complex surfaces, the problem of managing the identification and placement of corrective optics becomes even more pronounced, to the extent that in most cases the null corrector optics are specific to the particular asphere prescription and no others (i.e. another asphere requires completely different null correction optics). In principle, the near-nulling technique does not require subaperture stitching at all. Building a near-null system that is practically useful relies on two key features: simplicity and universality. If the system is too complex, it will be difficult to calibrate and model its manufacturing errors, rendering it useless as a precision metrology tool and/or prohibitively expensive. If the system is not applicable to a wide range of test parts, then it does not provide significant value over conventional null-correction technology. Subaperture stitching enables simpler and more universal near-null systems to be effective, because a fraction of a surface is necessarily less complex than the whole surface (excepting the extreme case of a fractal surface description). The technique of near-nulling can significantly enhance aspheric subaperture stitching capability by allowing the interferometer to capture a wider range of aspheres. More over, subaperture stitching is essential to a truly effective near-nulling system, since looking at a fraction of the surface keeps the wavefront complexity within the capability of a relatively simple nearnull apparatus. Furthermore, by reducing the subaperture size, the complexity of the measured wavefront can be reduced until it is within the capability of the near-null design.

Forbes, Greg↗

Intercontinental clock synchronization with the block 1 VLBI system

The Block 1 very long baseline interferometer (VLBI) operated by the Deep Space Network (DSN) to make weekly measurements of the relative epoch and rate offsets between the time standards in the global network of DSN stations is discussed. The precision of these measurements routinely achieves sub-microsecond levels for epoch offset and accuracies of better than one part in 10 to the 12th power for rate offset. The implementation of the phase calibrator system permits absolute measurement of epoch offset to better than 10 nanoseconds. With the near-real-time play-back and on-line storage of VLBI data, the Block 1 system typically produces clock parameters within 48 hours from the time of observation.

Roth, M. G.↗