At least 271 records · Page 15

Regenerable biocide delivery unit, volume 2

Source code for programs dealing with the following topics are presented: (1) life cycle test stand-parametric test stand control (in BASIC); (2) simultaneous aqueous iodine equilibria-true equilibrium (in C); (3) simultaneous aqueous iodine equilibria-pseudo-equilibrium (in C); (4) pseudo-(fast)-equilibrium with iodide initially present (in C); (5) solution of simultaneous iodine rate expressions (Mathematica); (6) 2nd order kinetics of I2-formic acid in humidity condensate (Mathematica); (7) prototype RMCV onboard microcontroller (CAMBASIC); (8) prototype RAM data dump to PC (in BASIC); and (9) prototype real time data transfer to PC (in BASIC).

Atwater, James E.↗

Continuous monitoring of bacterial attachment

A major concern with the Space Station Freedom (SSF) water supply system is the control of longterm microbial contamination and biofilm development in the water storage and distribution systems. These biofilms have the potential for harboring pathogens as well as microbial strains containing resistance factors that could negatively influence crew health. The proposed means for disinfecting the water system on SSF (iodine) may encourage the selection of resistant strains. In fact, biofilm bacteria were observed in water lines from the Space Shuttle Columbia (OV-102); therefore, an alternative remediation method is required to disinfect spacecraft water lines. A thorough understanding of colonization events and the physiological parameters that will influence bacteria adhesion is required. The limiting factor for development of this technology is the ability to continuously monitor adhesion events and the effects of biocides on sessile bacteria. Methods were developed to allow bacterial adhesion and subsequent biocidal treatment to be monitored continuously. This technique couples automated image analysis with a continuous flow of a bacterial suspension through an optical flow cell. A strain of Pseudomonas cepacia isolated from the water supply of the Space Shuttle Discovery (OV-103) during STS-39 was grown in a nitrogen-limited continuous culture. This culture was challenged continuously with iodine during growth, and the adhesion characteristics of this strain was measure with regard to flow rate. Various biocides (ozone, hypochlorite, and iodine) were added to the flow stream to evaluate how well each chemical removed the bacteria. After biocide treatment, a fresh bacterial suspension was introduced into the flow cell, and the attachment rate was evaluated on the previously treated surface. This secondary fouling was again treated with biocide to determine the efficacy of multiple batch chemical treatments in removing biofilm.

Koeing, D. W.↗

Spaceborne Photonics Institute

This report describes in chronological detail the development of the Spaceborne Photonics Institute as a sustained research effort at Hampton University in the area of optical physics. This provided the research expertise to initiate a PhD program in Physics. Research was carried out in the areas of: (1) modelling of spaceborne solid state laser systems; (2) amplified spontaneous emission in solar pumped iodine lasers; (3) closely simulated AM0 CW solar pumped iodine laser and repeatedly short pulsed iodine laser oscillator; (4) a materials spectroscopy and growth program; and (5) laser induced fluorescence and atomic and molecular spectroscopy.

Venable, D. D.↗

Development studies of Aurelia (jellyfish) ephyrae which developed during the SLS-1 mission

Aurelia polyps (scyphistomae) and ephyrae were exposed to microgravity for nine days aboard the space shuttle during the SLS-1 mission. During strobilation, polyps segment transversely and each segment develops into an ephyra. Polyps were induced to strobilate at 28 C, using iodine or thyroxine, at L(Launch)-48h, L-24h, and L+8h. Ephyrae developed in the groups tested in space and on Earth. The number of ephyrae formed per polyp was slightly higher in the L+8h groups as compared with those induced at L-24h and L-48h. On Earth, iodine is used by jellyfish to synthesize jellyfish-thyroxine (Jf T(sub 4)), needed for ephyra production. Since iodine-treated polyps strobilated and formed ephyrae in space, it appears that jellyfish can synthesize Jf-T(sub 4) in space. Indeed, two groups of polyps not given inducer formed ephryae in space, presumably due to enhanced Jf-T(sub 4) synthesis, utilization or accumulation. Some ephyrae that formed in space were also fixed in space on Mission Day (MD) 8; others were fixed post-flight. Examination of living ephyrae with the light microscope and fixed ones with the Scanning and Transmission Electron Microscopes revealed that those which developed in space were morphologically very similar to those which developed on Earth. Quantitation of arm numbers determined that there were no significant differences between space and Earth-developed ephyrae. Pulsing abnormalities, however, were found in greater number (18.3%) in space-developed ephyrae than in Earth-developed controls (2.9%). These abnormalities suggest abnormal development of the graviceptors, the neuromuscular system, or a defect in the integration between these systems in apparently microgravity-sensitive animals.

Spangenberg, D. B.↗

Instantaneous flow measurements in a supersonic wind tunnel using spectrally resolved Rayleigh scattering

Results of a feasibility study to apply laser Rayleigh scattering to non-intrusively measure flow properties in a small supersonic wind tunnel are presented. The technique uses an injection seeded, frequency doubled Nd:YAG laser tuned to an absorption band of iodine. The molecular Rayleigh scattered light is filtered with an iodine cell to block light at the laser frequency. The Doppler-shifted Rayleigh scattered light that passes through the iodine cell is analyzed with a planar mirror Fabry-Perot interferometer used in a static imaging mode. An intensified CCD camera is used to record the images. The images are analyzed at several subregions, where the flow velocity is determined. Each image is obtained with a single laser pulse, giving instantaneous measurements.

Seasholtz, Richard G.↗

Measurement Capabilities of Single-Pulse Planar Doppler Velocimetry

Preliminary investigations are described of a method that is capable of measuring instantaneous, 3-D, velocity vectors everywhere in a light sheet generated by a pulsed laser. The technique, here called Planar Doppler Velocimetry (PDV), is a variation of a new concept for velocity measurements that was called Doppler Global Velocimetry (DGV) in its original disclosure. The concept relies on the use of a narrowband laser and measurements of the Doppler shift of scattered light from particles moving with a flow. The Doppler shift is recorded as a variation in transmission through a sharp-edged spectral filter provided by iodine vapor in a cell. Entire fields of velocity can be determined by using a solid-state camera to record the intensity variations throughout the field of view. However, the implementation of DGV has been centered principally on the use of high power, continuous-wave, ion lasers and measurement times that are determined by the 30-ms framing times of standard video cameras. Hence, they provide velocity fields that are averaged in time at least over that period. On the other hand, the PDV concept described in this presentation incorporates a high energy, repetitively pulsed, Nd-YAG laser that is injection-seeded to make it narrowband and then frequency-doubled to provide light at frequencies absorbed by the iodine vapor. The duration of each pulse is less than 10 nanoseconds. When used in combination with nonstandard, scientific quality, solid state cameras, a sequence of images can be obtained that provides instantaneous velocity vectors everywhere in the field of view. The investigations described in this paper include an accurate characterization of the iodine cell spectral behavior and its influence on the PDV measurements, a derivation of the PDV signal analysis requirements, and the unique aspects of the pulsed laser behavior related to this application. In addition, PDV measurements are to be demonstrated using data from a rotating wheel target and from the flow of a subsonic jet. Initially, single optical fiber light collection and photomultiplier detectors will be substituted for solid state cameras. Those results will allow the determination of the fundamental limitations of the PDV technique without the complications of image acquisition and processing. They will then be used to provide an analysis of the measurement capabilities of PDV both in small aerodynamic research wind tunnels and in large wind tunnels designed for production airframe and propulsion testing. Future plans include the implementation of solid state cameras and the development of the required image acquisition and processing software. Eventually, the PDV technique will be applied to an aerodynamic research program related to transonic wing flutter.

McKenzie, Robert L.↗

Planar Particle Imaging Doppler Velocimetry Developed

Two current techniques exist for the measurement of planar, three-component velocity fields. Both techniques require multiple views of the illumination plane in order to extract all three velocity components. Particle image velocimetry (PIV) is a high-resolution, high accuracy, planar velocimetry technique that provides valuable instantaneous velocity information in aeropropulsion test facilities. PIV can provide three-component flow-field measurements using a two-camera, stereo viewing configuration. Doppler global velocimetry (DGV) is another planar velocimetry technique that can provide three component flow-field measurements; however, it requires three detector systems that must be located at oblique angles from the measurement plane. The three-dimensional configurations of either technique require multiple (DGV) or at least large (stereo PIV) optical access ports in the facility in which the measurements are being conducted. Optical access is extremely limited in aeropropulsion test facilities. In many cases, only one optical access port is available. A hybrid measurement technique has been developed at the NASA Glenn Research Center, planar particle image and Doppler velocimetry (PPIDV), which combines elements from both the PIV and DGV techniques into a single detection system that can measure all three components of velocity across a planar region of a flow field through a single optical access port. In the standard PIV technique, a pulsed laser is used to illuminate the flow field at two closely spaced instances in time, which are recorded on a "frame-straddling" camera, yielding a pair of single-exposure image frames. The PIV camera is oriented perpendicular to the light sheet, and the processed PIV data yield the two-component velocity field in the plane of the light sheet. In the standard DGV technique, an injection-seeded Nd:YAG pulsed laser light sheet illuminates the seeded flow field, and three receiver systems are used to measure three components of velocity. The receiver systems are oriented at oblique angles to the light sheet in order to accurately resolve the three-component velocity. Each DGV receiver system contains two cameras, which share a common view of the illuminated flow through a beam-splitting cube. One camera views the illuminated flow directly (reference camera) and the second camera images the illuminated flow through an iodine vapor cell (signal camera). The laser frequency (wavelength) is adjusted so that the Doppler-shifted light from particles in the flow falls on an iodine absorption feature, see the following graph. The iodine vapor cell acts as a frequency-to-velocity filter by modulating the intensity of the transmitted light as a function of the flow velocity (Doppler shift). The ratio of the signal and reference images yields the component of the flow velocity along the bisector of the laser sheet propagation direction and the receiver system observation direction. The hybrid system employs a single-component DGV receiver system configured to simultaneously acquire PIV image data, as shown in the following diagram. The cameras used in the DGV receiver are replaced with PIV frame-straddling cameras, and the receiver system views the illuminated light sheet plane at 90 (as in the standard PIV configuration).

Wernet, Mark P.↗

Characterization of Electrochemically Generated Silver

Silver biocide offers a potential advantage over iodine, the current state of the art in US spacecraft disinfection technology, in that silver can be safely consumed by the crew. Low concentrations of silver (<500 ppb) have been shown to kill bacteria in water systems and keep it safe for potability. Silver does not require hardware to remove it from a water system, and therefore can provide a simpler means for disinfecting water. The Russian segment of the International Space Station has utilized an electrochemically generated silver solution, which is colloidal in nature. To be able to reliably provide a silver biocide to drinking water by electrochemical means would reduce mass required for removing another biocide such as iodine from the water. This would also aid in crew time required to replace iodine removal cartridges. Future long term missions would benefit from electrochemically produced silver as the biocide could be produced on demand and requires only a small concentration to be effective. Since it can also be consumed safely, there is less mass in removal hardware and little consumables required for production. The goal of this project initially is to understand the nature of the electrochemically produced silver, the particle sizes produced by the electrochemical cell and the effect that voltage adjustment has on the particle size. In literature, it has been documented that dissolved oxygen and pH have an effect on the ionization of the electrochemical silver so those parameters would be measured and possibly adjusted to understand their effect on the silver.

Adam, Niklas↗

Conductivity and Ambient Stability of Halogen-Doped Carbon Nanotube Fibers

Carbon nanotube fibers were fabricated using a variety of spinning conditions and post-spinning processing with the goal of creating a high-conductivity yet environmentally stable fiber. These fiber variants were then doped with bromine, iodine, iodine chloride, or iodine bromide and their electrical and microstructural properties were characterized. Environmentally stable compounds were synthesized with electrical conductivity greater than 50,000 Scm.

carbon fibers↗

A CubeSat Asteroid Mission: Design Study and Trade-Offs

There is considerable interest in expanding the applicability of cubesat spacecraft into lightweight, low cost missions beyond Low Earth Orbit. A conceptual design was done for a 6-U cubesat for a technology demonstration to demonstrate use of electric propulsion systems on a small satellite platform. The candidate objective was a mission to be launched on the SLS test launch EM-1 to visit a Near-Earth asteroid. Both asteroid fly-by and asteroid rendezvous missions were analyzed. Propulsion systems analyzed included cold-gas thruster systems, Hall and ion thrusters, incorporating either Xenon or Iodine propellant, and an electrospray thruster. The mission takes advantage of the ability of the SLS launch to place it into an initial trajectory of C3=0. Targeting asteroids that fly close to earth minimizes the propulsion required for fly-by/rendezvous. Due to mass constraints, high specific impulse is required, and volume constraints mean the propellant density was also of great importance to the ability to achieve the required deltaV. This improves the relative usefulness of the electrospray salt, with higher propellant density. In order to minimize high pressure tanks and volatiles, the salt electrospray and iodine ion propulsion systems were the optimum designs for the fly-by and rendezvous missions respectively combined with a thruster gimbal and wheel system For the candidate fly-by mission, with a mission deltaV of about 400 m/s, the mission objectives could be accomplished with a 800s electrospray propulsion system, incorporating a propellant-less cathode and a bellows salt tank. This propulsion system is planned for demonstration on 2015 LEO and 2016 GEO DARPA flights. For the rendezvous mission, at a ΔV of 2000 m/s, the mission could be accomplished with a 50W miniature ion propulsion system running iodine propellant. This propulsion system is not yet demonstrated in space. The conceptual design shows that an asteroid mission is possible using a cubesat platform with high-efficiency electric propulsion.

cubesat↗

I-Xe Dating of Aqueous Alteration in the CI Chondrite Orgueil: I. Magnetite and Ferromagnetic Separates

The I-Xe system was studied in a ferromagnetic sample separated from the Orgueil CI carbonaceous chondrite with a hand-held magnet and in two magnetite samples, one chemically separated before and the other one after neutron irradiation. This work was done in order to investigate the effects of chemical separation by LiCl and NaOH on the I-Xe system in magnetite. Our test demonstrated that the chemical separation of magnetite before irradiation using either LiCl or NaOH, or both, does not contaminate the sample with iodine and thus cannot lead to erroneous I-Xe ages due to introduction of uncor-related128*Xe. The I-Xe ages of two Orgueil magnetite samples are mutually consistent within experimental uncertainties and, when normalized to an absolute time scale with the reevaluated Shallowater aubrite standard, place the onset of aqueous alteration on the CI parent body at 4564.3 ± 0.3 Ma, 2.9 ± 0.3 Ma after formation of the CV Ca-AI-rich inclusions (CAIs). The I-Xe age ofthe ferromagnetic Orgueil separate is 3.4 Ma younger, corresponding to a closure of the I-Xe system at 4560.9 ± 0.2 Ma. These and previously published I-Xe data for Orgueil (Hohenberg et al., 2000) indicate that aqueous alteration on the CI parent body lasted for at least 5 Ma. Although the two magnetite samples gave indistinguishable I-Xe ages, their temperature release profiles differed. One of the two Orgueil magnetites released less radiogenic Xe than the other, 80% of it corresponding to the low-temperature peak of the release profile, compared to only 6% in case of the second Orgueil magnetite sample. This could be due to the difference in iodine trapping efficiencies for magnetite grains of different morphologies. Alternatively, the magnetite grains with the lower radiogenic Xe concentrations may have formed at a later stage of alteration when iodine in an aqueous solution was depleted.

I-Xe systematics↗

Pulmonary Edema and Plasma Volume Changes in Dysbarism

Two groups of anesthetized, fasted pigs were utilized. One group of 13 animals (8.5 to 16.6 kilograms) was exposed to a high-pressure environment, and the other group of eight animals (6.9 to 20.0 kilograms) constituted the control group. The experimental group was subjected to an atmosphere of 90 percent nitrogen and 10 percent oxygen at a pressure of 50 psig for 30 minutes and then decompressed at a rate 10 psi/min. Plasma volumes, using both iodine-125-tagged-albumin and chromium-51-tagged-cell dilution techniques, were measured before, immediately after, and at 30 and 60 minutes after decompression. Aortic and right-ventricular systolic pressures were also recorded. At 60 minutes after decompression, blood samples were taken, the animals were sacrificed, and the water content of the lungs, kidneys, livers, and spleens was estimated by measuring tissue wet weight and dry weight. Protein extravasation and tissue blood volumes were determined by measuring the iodine-125-tagged-albumin and chromium-51-tagged-cell spaces in homo-genates of the organs under investigation.

Joki, J. A.↗

Electrochemical approach for passivating steel and other metals and for the simultaneous production of a biocide to render water potable

Potentiostatic polarization curves indicated that the cathodic reactions in deaerated KI-I2 water solutions were due to iodine reduction and hydrogen evolution. In the presence of oxygen an additional reduction wave appeared. Anodic polarization curves revealed that iodine could be produced in the region of potential from +600 to +1000 nv vs. SCE.

Source record↗

Water system microbial check valve development

A residual iodine microbial check valve (RIMCV) assembly was developed and tested. The assembly is designed to be used in the space shuttle potable water system. The RIMCV is based on an anion exchange resin that is supersaturated with an iodine solution. This system causes a residual to be present in the effluent water which provides continuing bactericidal action. A flight prototype design was finalized and five units were manufactured and delivered.

Colombo, G. V.↗

Nuclear pumped laser research at the Jet Propulsion Laboratory

Using a partially nuclear excited xenon flashlamp to pump an iodine laser, laser pulse shapes were analyzed with and without nuclear flashlamp augmentation. The pulse shapes indicate that the deposition of nuclear energy is equally as effective as electrical energy deposition in producing laser pulse energy output. The amplification of the E-beam pumped CF3I was measured at pressures of several atmospheres. Preliminary data shows that, for a part of the iodine laser pulse, amplification of almost a factor of two is measured. This measurement indicates that the gain in an E-beam pumped CF3I is an order of magnitude greater than in the coaxial laser tube.

Russell, G. R.↗

Search for Xe-129 in mineral grains from Allende inclusions - An exercise in miniaturized rare gas analysis

The paper considers the use of a static mass spectrometer modified by installation of a Baur-Signer ion source and an ion-counting system to detect xenon from single grains from inclusions in the C3 meteorite Allende. The inferred iodine concentrations increased from pentlandite to melilite, but vary widely from one grain to another, indicating that the iodine resides in a minor phase which is included 'spottily' in the bulk phases. It is likely that the detectability for excess Xe achieved here could be improved; about 23,000 of fissiogenic Xe-132 was detected in the largest melelite sample analyzed, but it cannot be determined from this study whether the PU-244 is 'spotty' like I-129 or is uniformly distributed in the melilite.

Reynolds, J. H.↗