Search NASA⌕ Search

SEARCH · Search NASA

Results for “levelized cost of energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Accelerated Scaling to Rapid Open-Air Fabrication of Durable Perovskite Solar Modules

The goals of this SETO project (DE-EE0008559, Accelerated Scaling to Rapid Open-Air Fabrication of Durable Perovskite Solar modules) are to address the principal challenges towards the successful commercialization of perovskite solar modules utilizing scalable, high-throughput open-air spray deposition. The successful outcome of the project will provide the foundation of an all open-air spray deposited perovskite solar module with hole transport layer (HTL), perovskite, electron transport layer (ETL), and barrier layer development while establishing a fundamental understanding of perovskite device behavior under accelerated aging conditions. Through this program, we have made significant progress towards a commercializable pathway for perovskites. (1) We’ve demonstrated the successful open-air deposition of perovskite and transport layer materials. These deposition methods were chosen for their inherent scalability, and open-air processing enables a significant reduction in processing costs. These methods are also compatible with high throughputs, demonstrating the fastest perovskite film deposition at these performance levels. (2) Development of a unique all-fiber laser scribing procedure provides a high-performance, low-cost method for further improvements in scalability. (3) Our group has also placed a unique emphasis on device stability. The development of testing standards for perovskite modules is required to thoroughly evaluate potential candidates for commercialization, and we’ve taken inspiration from current industry standards to provide an honest insight into the performance and reliability of our devices. (4) An extensive cost model detailing the specific contributions of each device layer and production component provides the most thorough evaluation of any perovskite technology against conventional silicon and compound semiconductor solar devices. The cost model is a critical advancement that will provide the foundation for evaluating the levelized cost of energy (LCOE) of this technology.

14 SOLAR ENERGY↗

Doping CdTe and CdSeTe for higher efficiency

Thin film cadmium telluride is one of the most successful photovoltaic technologies on the market today. Second only to silicon in yearly output and accounting for 40% of U.S. utility-scale photovoltaic installation, CdTe is known for its ease of manufacture, ideal bandgap, and low levelized cost of energy. Despite its commercial success, CdTe underperforms compared to its theoretical potential. The current world record CdTe device is only 21.0% compared to a theoretical maximum of 33.1%. This significant discrepancy in efficiencies can mostly be attributed to the poor open-circuit voltage of CdTe devices. Compared to silicon technologies, CdTe has a large voltage deficiency, exceeding 250 mV.

14 SOLAR ENERGY↗

Optimized Carbon Fiber Composites in Wind Turbine Blade Design: Follow-On Studies

This project has identified opportunities to bring further reductions in the mass and cost of modern wind turbine blades through the use of alternative material systems and manufacturing processes. The fiber reinforced polymer material systems currently used by the wind industry have stagnated as the technology continues to mature and as a means to reduce risk while introducing new products with continually increasing blade lengths. However, as blade lengths continue to increase, the challenge of controlling blade mass becomes even more critical to enabling the associated levelized cost of energy reductions. Stiffer and stronger reinforcement fibers can help to resolve the challenges of meeting the loading demands while limiting the increase in weight, but these materials are substantially more expensive than the traditional E-glass fiber systems. One goal of this project and associated work is to identify pathways that improve the cost-effectiveness of carbon fiber such that it is the reinforcement of choice in the primary structural elements of wind blades. The use of heavy-tow textile carbon fiber material systems has been shown to reduce the blade mass by 30-31% when used in the spar cap and by up to 7% when used in edgewise reinforcement. A pultrusion cost model was developed to enable a material cost comparison that includes an accurate estimate of the intermediate manufacturing step of pultrusion for the carbon fiber composite. Material cost reductions were revealed in most cases for the heavy-tow textile carbon fiber compared to infused fiberglass. The use of carbon fiber in the edgewise reinforcement produced the most notable material cost reduction of 33% for the heavy-tow textile carbon fiber. The mass and cost savings observed when using carbon fiber in edgewise reinforcement demonstrate a clear opportunity of this design approach. A carbon fiber conversion cost model was expanded to include a characterization of manufacturing costs when using advanced conversion processes with atmospheric plasma oxidation. This manufacturing approach was estimated to reduce the cost of carbon fiber material systems by greater than 10% and can be used with textile carbon systems or traditional carbon fiber precursors. The pultrusion cost model was also used to assess the opportunity for using pultruded fiberglass in wind blades, studying conventional E-glass fiber reinforcement. When using pultruded fiberglass as the spar cap material for two design classifications, the blade weight was reduced by 6% and 9% compared to infused fiberglass. However, due to the relatively large share of the pultrusion manufacturing cost compared to fiber cost, the spar cap material cost increased by 12% and 7%. When considering the system benefits of reduced blade mass and potentially lower blade manufacturing costs for pultruded composites, there may be opportunity for pultruded E-glass in wind blade spar caps, but further studies are needed. There is a clearer outcome for using pultruded fiberglass in the edgewise reinforcement where it resulted in a blade mass reduction of 2% and associated reinforcement material cost reduction of 1% compared to infused E-glass. The use of higher performing glass fibers, such as S-glass and H-glass systems, will produce greater mass savings but a study is needed to assess the cost implications for these more expensive systems. The most likely opportunity for these high-performance glass fibers is in the edgewise reinforcement, where the increased strength will reduce the damage accumulation of this fatigue-driven component. The blade design assessments in this project characterize the controlling material properties for the primary structural components in the flapwise and edgewise directions for modern wind blades. The observed trends with low and high wind speed turbine classifications for carbon and glass fiber reinforced polymer systems help to identify where cost reductions are needed, and where improvements in mechanical properties would help to reduce the material demands.

17 WIND ENERGY↗

In-situ hydrogen microstructural characterization of Si heterojunction passivation: Addressing V OC degradation and mitigation pathways

Si heterojunction (SHJ) solar cells have demonstrated record efficiency >27%, approaching the theoretical limit of ≈ 29%, primarily due to best surface/interface defect passivation provided by deposited thin layers of hydrogenated amorphous silicon (a-Si:H). Such excellent surface/interface passivation reduces recombination loss and result in >100 mV improvement of cell open circuit voltage (V OC ) to ≈ 750 mV, thus the cell efficiency. However, fielded SHJ modules exhibit loss of V OC and hence efficiency over time in years, presumably due to degradation related to a-Si:H layers. This adversely affects the technology’s market acceptance, and levelized cost of energy (LCOE). It is hypothesized that the origin of a-Si:H degradation is somehow related to the presence of weak Si–Si bonds and hydrogen in a-Si:H films. The objective of this project is to test this hypothesis by directly measuring chemical and structural changes occurring within SHJ component layers and solar cells. This is achieved by developing an innovative in-situ Fourier transform infrared (FTIR) spectrometry apparatus to monitor hydrogen microstructural changes occurring within amorphous silicon and decipher hydrogen evolution kinetics over time when samples are exposed to heat and/or light stress. These in-situ measured hydrogen microstructural changes are correlated to the changes in effective minority carrier lifetime (τ eff ), implied V OC (iV OC ), surface recombination velocity (S), and cell V OC . These mechanistic understandings will provide critical guidance to mitigate the V OC -driven degradation of SHJ solar cell performance. Passivation optimization and degradation analysis of individual SHJ component structures were achieved through systematic deposition of three symmetric structures and the completed SHJ solar cell structure. The three symmetric structures used were intrinsic a-Si:H [(i)a-Si:H] layers in a bilayer structure, intrinsic and p-type doped stacked layers [(i-p)a-Si:H] representing the front heterojunction in the SHJ cell, and intrinsic and n-typed doped stacked layers [(i-n)a-Si:H] representing the back-side back surface field (BSF) in the SHJ cell. State-of-the-art passivation qualities are demonstrated by a champion iV OC of 740 mV for the (i)a-Si:H layers, and the (i-n)a-Si:H symmetric structure. A 725 mV iV OC is observed for the (i-p)a-Si:H symmetric structure. These symmetric passivated SHJ component structures were subsequently subjected to different accelerated lifetime (ALT) stressors to identify which conditions contribute the most to iV OC degradation. Degradation of the thin (10 nm) (i)a-Si:H passivation layers without any additional overlying layers is minimal; complexity of this study arises due to unavoidable surface oxidation of (i)a-Si:H layer during most of the stress application, which is likely irrelevant for a full SHJ cell configuration with overlying protective layers. The iV OC degradation of symmetric structures is found to occur primarily at the (i-p)a-Si:H passivation stack under dark heat stress with associated hydrogen loss from the (p)a-Si:H layer. An activation energy for increase in S (defect creation) of 0.65 eV can be correlated to the activation energy of ≈ 0.4 eV for hydrogen loss from the (i-p)a-Si:H stack. This also suggests the presence of weakly bonded hydrogen in the (p)a-Si:H films, which effuses out of the film stack at such low activation energy. When light and heat stress are applied together, similar hydrogen loss from (i-p)a-Si:H stack is observed, however, does not appreciably degrade iV OC or increase S. This is an important result and departure from direct correlation between hydrogen loss and defect creation. This perhaps indicates additional defect chemistries or annealing that might be occurring in the presence of light requiring further detailed defect measurements. The full SHJ cell structure used for this project is depicted in Fig.1(d). SHJ cells with an initial V OC ≈ 700 mV were fabricated and subjected to similar ALT stress conditions. Cell V OC is found to degrade the most under dark heat stress and is confirmed by observed hydrogen migration out of the (i-p)a-Si:H stack. However, hydrogen cannot escape from the cell stack, it accumulates near the (p)a-Si:H/ITO contact interface, where ITO acts as a barrier preventing hydrogen loss. Furthermore, light-heat combined stress does not degrade V OC appreciably, confirming the occurrence of a defect annealing process.

14 SOLAR ENERGY↗

A Hot‐Swappable, Fault‐Tolerant, Modular Power Converter System for Solar Photovoltaic Plants

The performance metrics of the state-of-the-art commercial solar inverters, such as system cost, operation and maintenance (O&M) cost, service life, reliability, maintainability, and power density are much lower than the target metrics needed to achieve SunShot’s 2030 levelized cost of energy (LCOE) goals. To overcome the shortcomings of the existing solar inverters, this project proposed a novel Hot-Swappable, Fault-Tolerant, Modular Power Converter (HSFT-MPC) concept for solar photovoltaic (PV) plants and proved the concept through the design, fabrication, and laboratory test validation of a single-phase HSFT-MPC prototype. The HSFT-MPC has the following distinct advantages over the state-of-the-art: 1) elimination of harmonic/ electromagnetic interference (EMI) filter in the inverter stage due to the novel topology, 2) lower system cost and higher power density due to the modular design, elimination of harmonic/EMI filter, and lower cooling requirement, 3) higher efficiency due to lower switching frequencies, 4) higher reliability and longer (50 years) service life due to simpler cooling and fault tolerance capability, 5) easier installation, lower O&M cost, and improved maintainability due to the modular design and hot-swappable power electronic building blocks (PEBBs), and 6) improved manufacturability due to the modular design. This project developed a single-phase HSFT-MPC prototype with 25kW nominal output power, 2.4kV, 60Hz nominal AC output, lower than 5% AC output voltage total harmonic distortion, over 5 kW/L inverter power density, and 99.4% inverter peak efficiency, being tolerant to failure of single and multiple PEBBs, and capable of hot swapping of the failed PEBB(s). The HSFT-MPC enables uninterruptable operation of the solar PV plant when failure of single or multiple PEBBs or PV modules occurs. Compared with the existing solar inverters in the market, the HSFT-MPC is expected to reduce the inverter failure-caused downtime and energy losses of solar PV plants by more than 60% and 50%, respectively. Project findings have been presented at major conferences in the field and published in peer-reviewed papers, which added new knowledge to the field of power electronics for solar PV systems. A minicourse on Solar PV Systems was developed for outreach activities. The minicourse will help attract young individuals to the renewable energy profession which has a significant talent shortage. The HSFT-MPC is expected to overcome all of the shortcomings of the state-of-the-art solar inverters in terms of cost, efficiency, service life, reliability, maintainability, and manufacturability targets needed to achieve SunShot’s 2030 LCOE goals. Therefore, the proposed HSFT-MPC concept has the great potential to disrupt the current solar inverter market. This project created a pathway towards industry adoption of the HSFT-MPC to help achieve 50-year service life solar PV systems. Since the solar PV plants using the HSFT-MPC will feature with higher reliability, longer service life, and easier maintenance, they are particularly useful for the rural areas with underserved populations that demand reliable and affordable clean electricity. The outcomes of the project have the strong potential to address national needs in the field of renewable energy to reduce CO 2 emissions from the electricity sector, reduce imports of energy from foreign sources, and improve energy security, efficiency, and sustainability. Since electricity is used in almost all of society’s sectors, the outcomes of the project will benefit various sectors of society and economy.

14 SOLAR ENERGY↗

Conceptual Designs of the Structure of Inflatable Blades for Enabling Larger Turbines

Over the last couple of decades, increasingly larger rotor diameters have enabled significant reductions in the levelized cost of energy for wind through higher energy capture and improved capacity factors. But for onshore turbines, this has been met with manufacturing and transportation challenges. To enable larger onshore rotors, an innovative inflatable blade concept is investigated that employs both traditional and onsite manufacturing. The design architecture consists primarily of an inflatable aerodynamic shell attached to a factory-manufactured primary structure. Multiple architectures, cross-sectional topologies, and material combinations for the primary structure are investigated, as well as multiple skin materials. Structural cross-sectional characteristics are compared to a traditional blade, and inflatability and cost evaluations are presented. Results show that a box-beam architecture using only composite materials yields significant mass reduction with mature technologies/processes and modest cost decrease compared to traditional blade construction. This low-TRL study demonstrates the inflatable blade concept's techno-economic potential.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

A Methodology for Robust Load Reduction in Wind Turbine Blades Using Flow Control Devices

Decades of wind turbine research, development and installation have demonstrated reductions in levelized cost of energy (LCOE) resulting from turbines with larger rotor diameters and increased hub heights. Further reductions in LCOE by up-scaling turbine size can be challenged by practical limitations such as the square-cube law: where the power scales with the square of the blade length and the added mass scales with the volume (the cube). Active blade load control can disrupt this trend, allowing longer blades with less mass. This paper presents the details of the development of a robust load control system to reduce blade fatigue loads. The control system, which we coined sectional lift control or SLC, uses a lift actuator model to emulate an active flow control device. The main contributions of this paper are: (1) Methodology for SLC design to reduce dynamic blade root moments in a neighborhood of the rotor angular frequency (1P). (2) Analysis and numerical evidence supporting the use of a single robust SLC for all wind speeds, without the need for scheduling on wind speed or readily available measurements such as collective pitch or generator angular speed. (3) Intuition and numerical evidence to demonstrate that the SLC and the turbine controller do not interact. (4) Evaluation of the SLC using a full suite of fatigue and turbine performance metrics.

17 WIND ENERGY↗

Comparison of wind-farm control strategies under realistic offshore wind conditions: wake quantities of interest

Wind-farm control strategies aim to increase the efficiency, and therefore lower the levelized cost of energy, of wind farms. This is done by using turbine settings such as the yaw angle, blade pitch angles, or generator torque to manipulate the wake that negatively affects downstream turbines in the farm. Two inherently different wind-farm control methods have been identified in the literature: wake steering (WS) and active wake mixing (AWM). As one of two companion papers focused on understanding practical aspects of these two wind-farm control strategies using large-eddy simulation (LES), we below analyze the wake quantities of interest for a single wind turbine performing WS and AWM, while the companion article (Frederik et al., 2025) focuses on turbine quantities of interest including power and structural loads for the same computational setup and also includes two-turbine arrays with full and partial wake overlap. The simulations, which are based in the LES solver AMR-Wind, are tailored to have inflow conditions representative of measurements from a site off the East Coast of the US, including with strong veer and low turbulence. The turbine, which is modeled in OpenFAST and coupled to the LES, is the IEA 15 MW, an open-source offshore design. After presenting an overview of the wake recovery for the different wake-control cases, the analysis probes the fluid-dynamic causes for the different performance of the arrays reported in the companion article by examining control volumes around the wakes and the budget of the mean-flow kinetic energy (MKE) within these volumes. In the high veer environment considered, the MKE recovery is dominated by mean convection, and this is shown to especially benefit the WS strategy when a neighboring turbine is directly downstream: there is ≈65 % more available power for a downstream turbine than in the baseline case, and this power is gained primarily through mean convection on the left-tip and top-tip faces of the control volume. However, the case with imperfect knowledge of the exact wind direction favors the pulse-type AWM strategy, largely because of ≈9 % increased turbulent entrainment from aloft versus the baseline that could be related to an apparent resistance to skewing in the pulsed wake. The general reduced effectiveness of helix-type and other individual-pitch-based AWM strategies for inflow with high veer and low turbulence as reported in the companion paper is due, in part, to low magnitudes of phase-averaged turbulent entrainment. Two main findings of this study are thus that veer has a significant impact on the effectiveness of different wake-control strategies and that pulse-type AWM may be a useful strategy when the objective is power maximization in realistic, offshore flow environments with imperfect knowledge of the exact wake overlap position on the downstream turbine.

17 WIND ENERGY↗

Comparison of wind farm control strategies under realistic offshore wind conditions: turbine quantities of interest

Abstract. Wind farm flow control is a strategy to increase the efficiency and therefore lower the levelized cost of energy of a wind farm. This is done using turbine settings such as the yaw angle, blade pitch angles, or generator torque to manipulate the flow behind the turbine, affecting downstream turbines in the farm. Two inherently different wind farm flow control methods have been identified in the literature: wake steering and wake mixing. This paper focuses on comparing the turbine quantities of interest between these methods for a simple two-turbine wind farm setup, while a companion article (Brown et al., 2025) focuses on the wake quantities of interest for a single wind turbine setup. Both papers use the same set of wind farm simulations based on high-fidelity large-eddy simulations (LESs) coupled with OpenFAST turbine models. First, precursor simulations are executed in order to match wind conditions measured with lidars in an offshore wind farm off the east coast of the USA. These measurements show general wind conditions that exhibit substantially higher vertical wind shear and veer than any of the LES studies performed with wind farm flow control strategies currently available in the literature. The precursors are used to evaluate the effectiveness of the control methods. In the LES, the wind veer leads to highly skewed wakes, which have considerable influence on the power uplift of wind farm flow control strategies. In addition to a baseline controller, four different control strategies, each of which uses either pitch or yaw control, are performed on the upstream turbine of a simple two-turbine wind farm. Assuming that the wind direction is known and constant over time, the simulations show that wake steering is generally the superior wind farm flow control strategy, considering both wind farm power production and turbine damage equivalent loads when substantial wind veer is present. This result is consistent over different wind speeds and wind directions. On the other hand, for similar wind conditions with lower veer, wake mixing was found to yield the highest power production, although at the expense of generally higher loads. This leads us to conclude that the effect of wind veer, which has so far not usually been considered, can not be neglected when determining the optimal wind farm flow control strategy.

17 WIND ENERGY↗

Reference floating wind array designs for three representative regions

This work presents the systematic development of three open-source reference floating wind array designs. The designs are tailored to representative site conditions for three regions of the United States: Humboldt Bay off the coast of California, the Gulf of Maine, and the Gulf of America. We adopted existing reference designs for the individual 15 MW turbines, semisubmersible floating platforms, substations, mooring systems, and power cables – integrating and adapting them as needed for each location. We adapted existing dynamic cable designs to use larger conductor sizes to meet the arrays' power transmission requirements, and we set up redundant mooring systems for each substation. The layout of each array is a uniform-grid design optimized to approximately minimize the levelized cost of energy (LCOE) within a square lease area while satisfying spatial constraints. These constraints ensure adequate clearances between adjacent turbines and between underwater components during the layout optimization to prevent clashing and ensure that all components reside within the lease boundaries. Substations are included to allow accounting for intra-array cable costs. They are placed within the uniform grid to maintain the navigability of the arrays. For each feasible layout considered, annual energy production and cable routing costs are calculated and updated in the LCOE objective function. After the optimization, we refined the cable routing with a mix of algorithmic and manual methods to ensure that the cables avoid mooring system components and approach the substation with adequate clearances. We confirmed the suitability of each reference array's layout by comparing the wake losses at each wind heading angle to the wind rose, observing that the optimized layouts largely avoid wake losses in the predominant wind directions. These reference arrays provide open-source baseline designs to enable future research and innovation of floating wind technology at the array scale.

17 WIND ENERGY↗

Condition monitoring of wind turbine drivetrains: state-of-the-art technologies, recent trends, and future outlook

As global wind capacity expands, reducing operations and maintenance costs is critical to lowering the levelized cost of energy. This paper explores the state of the art in condition monitoring and prognostic strategies for wind turbine drivetrains, which are among the most failure-prone and maintenance-intensive subsystems. Current diagnostic methodologies are evaluated, covering supervisory control and data acquisition (SCADA) data, high-frequency vibration and acoustic analysis, machine learning and digital twin frameworks. Finally, practical challenges are identified that limit wide-scale industrial adoption, in order to guide future research and industrial efforts.

17 WIND ENERGY↗

Land-based wind turbines with flexible rail-transportable blades – Part 1: Conceptual design and aeroservoelastic performance

This work investigates the conceptual design and the aeroservoelastic performance of land-based wind turbines whose blades can be transported on rail via controlled bending. The turbines have a nameplate power of 5 MW and a rotor diameter of 206 m, and they aim to represent the next generation of land-based machines. Three upwind designs and two downwind designs are presented, combining different design goals together with conventional glass and pultruded carbon fiber laminates in the spar caps. One of the five blade designs is segmented and serves as a benchmark to the state of the art in industry. The results show that controlled flexing requires a reduction in the flapwise stiffness of the blades, but it represents a promising pathway for increasing the size of land-based wind turbine rotors. Given the required stiffness, the rotor can be designed either downwind with standard rotor preconing and nacelle uptilt angles or upwind with higher-than-usual angles. A downwind-specific controller is also presented, featuring a cut-out wind speed reduced to 19 m s –1 and a pitch-to-stall shutdown strategy to minimize blade tip deflections toward the tower. The flexible upwind and downwind rotor designs equipped with pultruded carbon fiber spar caps are found to generate the lowest levelized cost of energy, 2.9 % and 1.3 %, respectively, less than the segmented design. The paper concludes with several recommendations for future work in the area of large flexible wind turbine rotors.

17 WIND ENERGY↗

Sensitivity analysis of numerical modeling input parameters on floating offshore wind turbine loads

Abstract. Floating wind turbines must withstand a unique and challenging set of loads from the wind and ocean environment. To de-risk development, accurate predictions of these loads are necessary. Uncertainty in modeling predictions leads to larger required safety factors, increasing project costs and the levelized cost of energy. Complex aero-hydro-elastic modeling tools use many input parameters to represent the wind, waves, current, aerodynamic loads, hydrodynamic loads, and structural properties. It is helpful to understand which of these parameters ultimately drives a design. In this work, an ultimate and fatigue-proxy load sensitivity analysis was performed with 35 different input parameters, using an elementary effects approach to identify the most influential parameters for a case study involving the National Renewable Energy Laboratory (NREL) 5 MW baseline wind turbine atop the OC4-DeepCwind semisubmersible during normal operation. The importance of each parameter was evaluated using 14 response quantities of interest across three operational wind speed conditions. The study concludes that turbulent wind velocity standard deviation is the parameter with the strongest sensitivity; this value is important not just for turbine loads, but also for the global system response. The system center of mass in the wind direction is found to have the highest impact on the system rotation and tower loads. The current velocity is found to be the most dominating parameter for the system global motion and consequently the mooring loads. All tested wind turbulence parameters in addition to the standard deviation are also found to be influential. Wave characteristics are influential for some fatigue-proxy loading but do not significantly impact the extreme ultimate loads in these operational load cases. The required number of random seeds for stochastic environmental conditions is considered to ensure that the sensitivities are due to the input parameters and not due to the seed. The required number of analysis points in the parameter space is identified so that the conclusions represent a global sensitivity. The results are specific to the platform, turbine, and choice of parameter ranges, but the demonstrated approach can be applied widely to guide focus in parameter uncertainty.

17 WIND ENERGY↗

Technoeconomic Analysis of the Miba Segmented Journal Bearing

This presentation describes a technoeconomic analysis using NLR's Windfarm Operations & Maintenance cost-Benefit Analysis Tool (WOMBAT) to compare operational expenses and levelized cost of energy for wind turbines using standard spherical roller bearings with a novel segmented journal bearing developed by Miba.

17 WIND ENERGY↗

The dish-Rankine SCSTPE program (Engineering Experiment no. 1)

Activities planned for phase 2 Of the Small Community Solar Thermal Power Experiment (PFDR) program are summarized with emphasis on a dish-Rankine point focusing distributed receiver solar thermal electric system. Major design efforts include: (1) development of an advanced concept indirect-heated receiver;(2) development of hardware and software for a totally unmanned power plant control system; (3) implementation of a hybrid digital simulator which will validate plant operation prior to field testing; and (4) the acquisition of an efficient organic Rankine cycle power conversion unit. Preliminary performance analyses indicate that a mass-produced dish-Rankine PFDR system is potentially capable of producing electricity at a levelized busbar energy cost of 60 to 70 mills per KWh and with a capital cost of about $1300 per KW.

Pons, R. L.↗

The performance of solar thermal electric power systems employing small heat engines

The paper presents a comparative analysis of small (10 to 100 KWe) heat engines for use with a solar thermal electric system employing the point-focusing, distributed receiver (PF-DR) concept. Stirling, Brayton, and Rankine cycle engines are evaluated for a nominal overall system power level of 1 MWe, although the concept is applicable to power levels up to at least 10 MWe. Multiple concentrators are electrically connected to achieve the desired plant output. Best performance is achieved with the Stirling engine, resulting in a system Levelized Busbar Energy Cost of just under 50 mills/kWH and a Capital Cost of $900/kW, based on the use of mass-produced components. Brayton and Rankine engines show somewhat less performance but are viable alternatives with particular benefits for special applications. All three engines show excellent performance for the small community application.

Pons, R. L.↗