Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

267 records · Page 15

Calibration of the DSCOVR EPIC Visible and NIR Channels using MODIS Terra and Aqua Data and EPIC Lunar Observations

The unique position of the Deep Space Climate Observatory (DSCOVR) Earth Polychromatic Imaging Camera (EPIC) at the Lagrange 1 point makes an important addition to the data from currently operating low Earth orbit observing instruments. EPIC instrument does not have an onboard calibration facility. One approach to its calibration is to compare EPIC observations to the measurements from polar-orbiting radiometers. Moderate Resolution Imaging Spectroradiometer (MODIS) is a natural choice for such comparison due to its well-established calibration record and wide use in remote sensing. We use MODIS Aqua and Terra L1B 1km reflectances to infer calibration coefficients for four EPIC visible and NIR channels: 443, 551, 680 and 780 nm. MODIS and EPIC measurements made between June 2015 and 2016 are employed for comparison. We first identify favorable MODIS pixels with scattering angle matching temporarily collocated EPIC observations. Each EPIC pixel is then spatially collocated to a subset of the favorable MODIS pixels within 25 km radius. Standard deviation of the selected MODIS pixels as well as of the adjacent EPIC pixels is used to find the most homogeneous scenes. These scenes are then used to determine calibration coefficients using a linear regression between EPIC counts/sec and reflectances in the close MODIS spectral channels. We present thus inferred EPIC calibration coefficients and discuss sources of uncertainties. The lunar EPIC observations are used to calibrate EPIC O2 absorbing channels (688 and 764 nm), assuming that there is a small difference between moon reflectances separated by approx.10 nm in wavelength provided the calibration factors of the red (680 nm) and near-IR (780 nm) are known from comparison between EPIC and MODIS.

Geogdzhayev, Igor V.↗

Architecture Options for Navigation in Cislunar Space for Human Landing System Vehicles

As part of architecture studies and insight analysis focused on requirements development into Human Landing System lunar architecture designs, multiple studies are underway to understand the sensitivities and options for achieving high precision landing on the lunar surface. The baseline approach utilizes a combination of multiple sensors to capture autonomous state observations of the lander with respect to the lunar surface. These systems are typically constrained in terms of operational altitudes by parameters such as onboard map size, camera focus, or sensor transmitted power (for altimeter observations). While these sensor suites do enable high precision landing, they are typically very complex and expensive. For a human-rated vehicle, fault detection algorithms are needed in addition to redundant sensors drive additional design complexity. Conversely, for these early missions, mass performance is key, so extended analysis is required to identify numbers of sensors, their ideal placement, and integration algorithms. A key part of this analysis is to help identify key sensor suites and options to help alleviate this design tension. An alternate approach is to take advantage and build out in-situ assets to allow for GPS-like navigation within the lunar regime through the use of navigation references or beacons. This can be achieved through the integration of navigation services into potential relays and pre-placed lunar surface assets. This research focuses on the capability of this infrastructure to support navigation in all areas of cislunar space such as: approach to the moon, in orbit around the moon, and ascent/descent operations to the surface. An augmented state linear covariance analysis (LinCov) and navigation state covariance analysis (NavCov) tools were used to assess a variety of navigation reference locations and how they can support vehicle operations through both understanding of state uncertainties and trajectory dispersions. This research helps to supplement existing studies focused on communication link analysis by providing additional insight into specific vehicle operational scenarios that are tied closely to potential Human Landing System scenarios. Key aspect of this analysis focus on the sensitivity to state knowledge of the references, the accuracy of inter-asset measurements, and placement in support of the various scenarios.

Evan J Anzalone↗

Laser-Induced Incandescence Calibration via Gravimetric Sampling

Various beam imaging and/or sheet forming optics delivered light at 1064 nm from a pulsed Nd:YAG laser for use either as a beam of 3 mm radius or as a laser sheet. Imaging measurements were performed with a grated intensified array camera equipped with an ultraviolet f4.5 lens and a 40 mm extension tube. Point measurements were performed using an ultraviolet 250 mm focal length lens to collect and focus the laser induced incandescence (LII) signal into a 1 meter long quartz optical fiber which directed the LII signal to a 1/4 meter monochromator. An aperture preceding the lens restricted the signal collection region to 1 cm along the laser beam at the center of the gravimetric chimney. Signals from the PMT were processed by a boxcar integrator whereas the images were captured digitally using a frame-grabber with 16 MByte of on-board memory. Both 'point' and planar measurements were made with detector gates of 250 ns to minimize possible morphology bias in collection of the LII signal. Additionally, the imaging measurements were performed with broadband spectral collection of the LII signal to maximize the signal and again minimize any potential effects of morphology dependent heating and/or cooling rates. Digital delay generators controlled the firing of he laser, detector gates and data acquisition. Neutral density filters were used for both sets of measurements to maintain signal levels within linear dynamic ranges of the detectors, the range being determined prior to experiments.

VanderWal, R. L.↗

A Consistent EPIC Visible Channel Calibration using VIIRS and MODIS as a Reference

The Earth Polychromatic Imaging Camera (EPIC) aboard the Deep Space Climate Observatory (DSCOVR) satellite constantly images the sunlit disk of Earth from the Lagrange-1 (L1) point in 10 spectral channels spanning the UV, VIS, and NIR spectrums. Recently, the DSCOVR EPIC team has publicly released version 2 dataset, which has implemented improved navigation, stray-light correction, and flat-fielding of the CCD array. The EPIC 2-year data record must be well-calibrated for consistent cloud, aerosol, trace gas, land use and other retrievals. Because EPIC lacks onboard calibrators, the observations made by EPIC channels must be calibrated vicariously using the coincident measurements from radiometrically stable instruments that have onboard calibration systems. MODIS and VIIRS are best-suited instruments for this task as they contain similar spectral bands that are well-calibrated onboard using solar diffusers and lunar tracking. We have previously calibrated the EPIC version 1 dataset by using EPIC and VIIRS angularly matched radiance pairs over both all-sky ocean and deep convective clouds (DCC). We noted that the EPIC image required navigations adjustments, and that the EPIC stray-light correction provided an offset term closer to zero based on the linear regression of the EPIC and VIIRS ray-matched radiance pairs. We will evaluate the EPIC version 2 navigation and stray-light improvements using the same techniques. In addition, we will monitor the EPIC channel calibration over the two years for any temporal degradation or anomalous behavior. These two calibration methods will be further validated using desert and DCC invariant Earth targets. The radiometric characterization of the selected invariant targets is performed using multiple years of MODIS and VIIRS measurements. Results of these studies will be shown at the conference.

Haney, C. O.↗

3-D Reconstruction of Macular Type II Cell Innervation Patterns in Space-Flight and Control Rats

A semiautomated method for reconstructing objects from serial thin sections has been developed in the Biocomputation Center. The method is being used to completely, for the first time, type II hair cells and their innervations. The purposes are to learn more about the fundamental circuitry of the macula on Earth and to determine whether changes in connectivities occur under space flight conditions. Data captured directly from a transmission electron microscope via a video camera are sent to a graphics workstation. There, the digitized micrographs are mosaicked into sections and contours are traced, registered and displayed by semiautomated methods. Current reconstructions are of type II cells from the medial part of rat maculas collected in-flight on the Space Life Sciences-2 mission, 4.5 hrs post-flight, and from a ground control. Results show that typical type II cells receive processes from tip to six nearby calyces or afferents. Nearly all processes are elongated and have bouton-like enlargements; some have numerous vesicles. Multiple (2 to 4) processes from a single calyx to a type II cell are common, and approximately 1/3 of the processes innervale 2 or 3 type II cells or a neighboring cluster. From 2% to 6% of the cells resemble type I cells morphologically but have demi-calyces. Thus far, increments in synaptic number in type II cells of flight rats are prominent along processes that supply two hair cells. It is clear that reconstruction methods provide insights into details of macular circuitry not obtainable by other techniques. The results demonstrate a morphological basis for interactions between adjacent receptive fields through feed back-feed forward connections, and for dynamic alterations in receptive field range and activity during preprocessing of linear acceleratory information by the maculas. The reconstruction method we have developed will find further applications in the study of the details of neuronal architecture of more complex systems, to seek out shared organizational properties or neuronal networks and to understand better localization of synaptic changes in altered environments.

Ross, Muriel Dorothy↗

NASA Tech Briefs, June 2010

Topics covered include: Situational Awareness from a Low-Cost Camera System; Data Acquisition System for Multi-Frequency Radar Flight Operations Preparation; Mercury Toolset for Spatiotemporal Metadata; Social Tagging of Mission Data; Integrating Radar Image Data with Google Maps; Demonstration of a Submillimeter-Wave HEMT Oscillator Module at 330 GHz; Flexible Peripheral Component Interconnect Input/Output Card; Interface Supports Lightweight Subsystem Routing for Flight Applications; MMIC Amplifiers and Wafer Probes for 350 to 500 GHz; Public Risk Assessment Program; Particle Swarm Optimization Toolbox; Telescience Support Center Data System Software; Update on PISCES; Ground and Space Radar Volume Matching and Comparison Software; Web-Based Interface for Command and Control of Network Sensors; Orbit Determination Toolbox; Distributed Observer Network; Computer-Automated Evolution of Spacecraft X-Band Antennas; Practical Loop-Shaping Design of Feedback Control Systems; Fully Printed High-Frequency Phased-Array Antenna on Flexible Substrate; Formula for the Removal and Remediation of Polychlorinated Biphenyls in Painted Structures; Integrated Solar Concentrator and Shielded Radiator; Water Membrane Evaporator; Modeling of Failure for Analysis of Triaxial Braided Carbon Fiber Composites; Catalyst for Carbon Monoxide Oxidation; Titanium Hydroxide - a Volatile Species at High Temperature; Selective Functionalization of Carbon Nanotubes: Part II; Steerable Hopping Six-Legged Robot; Launchable and Retrievable Tetherobot; Hybrid Heat Exchangers; Orbital Winch for High-Strength, Space-Survivable Tethers; Parameterized Linear Longitudinal Airship Model; and Physics of Life: A Model for Non-Newtonian Properties of Living Systems.

Source record↗

Burning and Suppression of Solids–II (BASS-II) Summary Report

The Burning and Suppression of Solids (BASS) experiment hardware is a small flow duct that provides containment for small scale burning of solid samples within the Microgravity Science Glovebox (MSG) aboard the International Space Station (ISS). A video camera with a data overlay and a 35-mm still camera record the combustion events. The controls (ignition, fan speed, etc.) are operated by an astronaut while the principal investigator team monitors the experiment from the ground and communicates directly with the astronaut. For the first time on ISS, BASS–II utilized MSG working volume dilution with gaseous N2. We developed a perfectly stirred reactor model to determine the N2 flow time and flow rate to obtain the desired reduced O2 concentration in the working volume for each test. We calibrated the model with the Compound Specific Analyzer-Combustion Products (CSA-CP) O2 readings offset using the Major Constituents Analyzer reading of the ISS ambient atmosphere data for that day. This worked out extremely well for operations, and added a new vital variable, ambient O2 level, to our test matrices. The main variables tested in BASS–II were ambient O2 concentration, ventilation flow velocity, and fuel type, thickness, and geometry. BASS–II also utilized the onboard CSA-CP for O2 and CO readings, and the Carbon Dioxide Monitor for CO2 readings before and after each test. Readings from these sensors allow us to evaluate the completeness of the combustion. The O2 and CO2 readings before and after each test were analyzed and compared very well to stoichiometric ratios for a one-step gas-phase reaction. The CO versus CO2 followed a linear trend for some datasets, but not for all the different geometries of fuel and flow tested. We calculated the heat release rates during each test from the O2 consumption and burn times, using the constant 13.1 kJ of heat released per gram of O2 consumed. The results showed that most of the tests had heat release rates well below 100 W. Lastly, the global equivalence ratio for the tests is estimated to be fuel rich, 1.3 on average using mass loss and O2 consumption data.

Microgravity↗

Gravity Sensors and the Role of 3-D Visualization and Simulation in Biomedical Research

Ross 3.0 software was developed in the Biocomputation Center for semi-automated reconstruction of objects from serial thin sections. Data are captured directly from a transmission electron microscope via a video camera to a graphics workstation where the sections are mosaicked and contours are traced, registered and displayed by semi-automated methods. For the first time, macular type II cells are described completely for their innervation patterns. The purposes are to learn more about the fundamental circuitry of the macula and to demonstrate whether the terminals are altered morphologically by space flight. Current examples, from the medial part of the macula, are from maculas collected in-flight on the Space Life Sciences-2 mission, 4.5 hrs post-flight, and from a ground control. Results show that the typical type 11 cell receives processes from up to six nearby calyces or afferents. Nearly all the processes are elongated; some have bouton-like swellings and numerous vesicles. Multiple (2 to 4) processes from a single calyx to a type II cell are common, and approx. 1/3 of the processes innervate 2 type II cells of a neighboring cluster of 3 cells. About 2% of type II cells resemble type I cells morphologically and are surrounded by demicalyces. Differences in size or shape of the terminals under flight conditions could not be determined because the sample size is still too small; but it is clear that reconstruction methods provide insights into macular circuitry not obtainable by other techniques. The results demonstrate a morphological basis for interactions between adjacent receptive fields, through feedback-feedforward connections, during preprocessing of linear acceleratory information by the maculas. While the methods are currently being tested using vestibular maculas as the model system, it is clear that the technology is applicable to any tissue that can be physically or optically sectioned. ROSS software has already been implemented for reconstructing objects from tissues studied by confocal and by transmitted light microscopy, and research into magnetic resonance imaging-computational tomography combined visualization are underway.

Ross, Muriel D.↗

Multi-waveband observations of colliding galaxies

Colliding galaxies represent a major challenge to both theorists and observers because of the large variety of phenomena which are expected to come into play during the interaction. Strong gravitational fluctuations may drive non-linear waves and instabilities throughout the stars and gas leading to enhanced star formation, nuclear activity and ultimately a mixing of the morphological components of the original galaxies. One relatively uncomplicated class of colliding galaxy where stellar waves play an important role in star formation are ring galaxies. Ring galaxies are probably formed when a companion galaxy passes through the center of a disk system driving circular waves through the disk (Lynds and Toomre 1976, Toomre 1978, Struck-Marcell 1990). Off-center collisions can generate non-circular waves and can be loosely described as banana-shaped although they may exhibit more complex forms as the waves expand into the disk. The propagation of such stellar and gaseous waves through the disk leads to enhanced star formation (e.g., Appleton and Struck-Marcell 1987a; Jeske 1986) and provides a unique probe of the response of the interstellar medium (ISM) to a propagating wave (see Appleton and Struck-Marcell 1987b). Here, the authors report results for 3 systems; the irregular ring Arp 143 (=VV 117); Wakamatsu's Seyfert ring (A0959-755; see Wakamatsu and Nishida 1987) and the brighter member of the pair of ring galaxies comprising of AM 1358-221. The most complete multi-wavelength data is for Arp 143. Optical charge coupled device (CCD) observations made with the 60 inch Palomar telescope at BV and r band, near-IR images at J (1.25 microns), H (1.65 microns) and k (2.2 microns) bands from the infrared camera (IRCAM) InSb array camera on the 3.8m United Kingdon Infrared Telescope (UKIRT) telescope and very large array (VLA) observations at 20cm in both the neutral hydrogen line and radio continuum are described. The observations of Wakamatsu's ring and AM 1358 were made only in the near-IR, and a comparison is made with available optical plate material.

Appleton, P. N.↗

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, and spinal elongation. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, measurement tools have not been available for accurate assessments of body shape changes. This work aimed to develop a prototype 3-D body scanning system with the configuration and performance optimized for in-flight crewmember body scanning. A scan hardware system was developed using Intel RealSense commercial off-the-shelf 3D sensors. The sensor parameters were iteratively optimized and tested to obtain the performance level needed for body scanning. A scan booth structure was fabricated, with the overall size 4 x 4 x 8 feet. The specific number of sensors and mounting positions were determined by iterative simulations, which indicated that 16 cameras can capture 94% and 96% of body surface area from the 1st percentile female and 99th percentile male crew population subject. The mounted sensors were linked through a mix of USB-C and USB-3 cables and operated for data acquisition from a Linux laptop computer. A software prototype was developed using Python and Tkinter graphical user interface toolkit. A calibration procedure was also built using a panel of QR codes. A computer vision tool detected and decoded the unique ID and pattern locations of the QR codes. The calibration information determined the position and orientation of the 3D sensors with respect to each other. The scanner performance was assessed using a set of 3D printed custom manikins. The manikin size and shape were derived from the previous ISS study, which measured the crewmembers’ anthropometry changes across the different flight phases. The average anthropometric measurements at the pre-flight and flight day 15 were sampled and projected onto the 1st percentile female and 99th percentile male body shapes. Another pair of manikins were also 3D printed to simulate the neutral body posture, estimated from ISS microgravity environments. A preliminary analysis assessed the performance of the newly developed scanner against the reference scanner, which has been used at the NASA JSC for crew and test subject anthropometry. Although the new scanner data showed several artifacts and missing geometries in the occluded body areas such as armpits and crotch, overall shape matched with the reference scan. When the manikin surface coordinates were compared, a root mean square error of 1.3 cm was observed from the manikin torso segment. Linear measurements including the stature, knee height and circumference measurements at the chest and calf showed differences from the reference scan measurements, ranging between 0.3 and 0.9 cm. Overall, this work demonstrated a development framework for an in-flight scanner with design and operation optimized for crewmember body scanning. Further improvement can potentially provide previously unavailable anthropometric data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗

Simulation System for Training in Laparoscopic Surgery

A computer-based simulation system creates a visual and haptic virtual environment for training a medical practitioner in laparoscopic surgery. Heretofore, it has been common practice to perform training in partial laparoscopic surgical procedures by use of a laparoscopic training box that encloses a pair of laparoscopic tools, objects to be manipulated by the tools, and an endoscopic video camera. However, the surgical procedures simulated by use of a training box are usually poor imitations of the actual ones. The present computer-based system improves training by presenting a more realistic simulated environment to the trainee. The system includes a computer monitor that displays a real-time image of the affected interior region of the patient, showing laparoscopic instruments interacting with organs and tissues, as would be viewed by use of an endoscopic video camera and displayed to a surgeon during a laparoscopic operation. The system also includes laparoscopic tools that the trainee manipulates while observing the image on the computer monitor (see figure). The instrumentation on the tools consists of (1) position and orientation sensors that provide input data for the simulation and (2) actuators that provide force feedback to simulate the contact forces between the tools and tissues. The simulation software includes components that model the geometries of surgical tools, components that model the geometries and physical behaviors of soft tissues, and components that detect collisions between them. Using the measured positions and orientations of the tools, the software detects whether they are in contact with tissues. In the event of contact, the deformations of the tissues and contact forces are computed by use of the geometric and physical models. The image on the computer screen shows tissues deformed accordingly, while the actuators apply the corresponding forces to the distal ends of the tools. For the purpose of demonstration, the system has been set up to simulate the insertion of a flexible catheter in a bile duct. [As thus configured, the system can also be used to simulate other endoscopic procedures (e.g., bronchoscopy and colonoscopy) that include the insertion of flexible tubes into flexible ducts.] A hybrid approach has been followed in developing the software for real-time simulation of the visual and haptic interactions (1) between forceps and the catheter, (2) between the forceps and the duct, and (3) between the catheter and the duct. The deformations of the duct are simulated by finite-element and modalanalysis procedures, using only the most significant vibration modes of the duct for computing deformations and interaction forces. The catheter is modeled as a set of virtual particles uniformly distributed along the center line of the catheter and connected to each other via linear and torsional springs and damping elements. The interactions between the forceps and the duct as well as the catheter are simulated by use of a ray-based haptic-interaction- simulating technique in which the forceps are modeled as connected line segments.

Basdogan, Cagatay↗

Quantifying Leak Rates and Vacuum Impact on Granular Soil Column Pneumatic Seal

Introduction: All In-Situ Resource Utilization (ISRU) regolith reactor systems that aim to extract gases or vapors must maintain a seal along the flow path of the regolith from the inlet hopper to where extracted gases or vapors are generated. Using a column of regolith at the inlet has been proposed as an alternative to systems using series of mechanical valves to reduce mass and complexity. Preliminary investigations into the use of regolith itself as a barrier to escaping fluids have been conducted, which this research seeks to expand upon. Different vertical regolith simulant plug diameters and heights were tested under vacuum with dry nitrogen to observe leak rates and approximate steady state pressure gradient equilibria. The effect of absolute ambient pressure was also studied by repeating tests at incremental pressures ranging from 10e-5 Torr up to 1 atm to corroborate ambient bench tests from previous work. The impact of regolith dynamics was addressed to emulate continuous-feed regolith reaction processes by measuring leak rates through continuously draining simulant columns. OB-1 lunar highlands regolith simulant was used. Experimental Setup: Regolith simulant columns were constructed using a motorized butterfly valve separating upper acrylic tubes of various diameters from a larger, lower aluminum pipe plenum (See Figure 1). The butterfly valve was cracked open such that gas could freely pass through whereas regolith would bridge and stay suspended as a cohesive plug above in the acrylic portion. These assemblies were loaded into a vacuum chamber, and a compressed dry nitrogen line was routed into the lower plenum. Pressure transducers measured the absolute pressure of the lower plenum, which was compared to absolute chamber pressure to monitor the pressure gradient across the regolith simulant. A precision mass flow controller enabled fine control of plenum pressure. The plenum pressure was quasi-statically increased to set points informed by previous work [1] before shutting off the gas supply to allow the now pressurized gas volume to dissipate through the simulant into the chamber in what was referred to as a ‘leak test.’ In a separate set of tests, the pressure was allowed to quasi-statically build until visual disturbances in the soil were observed via remote camera feeds. Initial leak rate tests were repeated on the disturbed soil to observe changes in leak rates between initial as-poured and post-bubbling soil conditions. This test schedule was applied to simulant columns of three different diameters (approximately 2, 4, and 6 inches) as well as two different heights (around 8 and 16 inches) and was repeated at least three times for each configuration. Plenums were also pressurized while the butterfly valves were opened slightly further to facilitate slow, controlled, constant flowrate draining of the simulant to observe the impact that continuous-feed systems might have on leak rate through the regolith column. Finally, the regolith columns were reset and refilled and static leak rate tests were repeated approximately every decade in ambient pressure from 10e-5 Torr up to ambient conditions to observe the impact of transitioning out of the molecular flow regime on regolith column seal performance. Analysis: Trends with respect to each factor examined were constructed and reported alongside commentary on the most likely responsible physical phenomena. Confidence intervals were applied to the predictive findings of the data by quantifying instrumentation error and accounting for probabilistic impacts of curve fitting the generic exponential function onto pressure decay data. The leak rate is assumed directly proportional to the exponential term coefficient, while the steady-state static pressure gradient is assumed to be the asymptotic limit of each curve fit. Finally, a generic model developed by Ogino et al. [2] and later tuned for ambient testing was re-tuned using vacuum data to estimate leak rates on the lunar surface. Results: Pressure decay rates decreased up to 27-fold under vacuum when compared to ambient pressure, as shown in Figure 2. Simulant column diameter was found to exponentially correlate to both regolith column leak rate and steady-state equilibrium pressure delta. Height was found to be linearly related to leak rate –doubling the regolith column height consistently yielded around a 40% reduction in leak rate. Dynamic regolith draining was found to slightly increase leak rate, although to a lower degree than expected. Conclusion: Because of the transition into molecular gas flow through regolith, vacuum testing is required to properly estimate performance. Regolith columns should be designed as narrow as possible to avoid bridging and minimize leak rate, and as tall as is feasible to both further reduce leak rate and to help prevent bubbling, which has been shown to degrade the quality of the regolith seal. Disrupted soil was found to exhibit higher leak rates than pristine, as-poured soil, indicating the need to consider the impact of recovery from depressurization events. Regolith columns appear equally feasible for both dosed and continuous-feed reactors.

ISRU↗

Metrology of Large Parts

As discussed in the first chapter of this book, there are many different methods to measure a part using optical technology. Chapter 2 discussed the use of machine vision to measure macroscopic features such as length and position, which was extended to the use of interferometry as a linear measurement tool in chapter 3, and laser or other trackers to find the relation of key points on large parts in chapter 4. This chapter looks at measuring large parts to optical tolerances in the sub-micron range using interferometry, ranging, and optical tools discussed in the previous chapters. The purpose of this chapter is not to discuss specific metrology tools (such as interferometers or gauges), but to describe a systems engineering approach to testing large parts. Issues such as material warpage and temperature drifts that may be insignificant when measuring a part to micron levels under a microscope, as will be discussed in later chapters, can prove to be very important when making the same measurement over a larger part. In this chapter, we will define a set of guiding principles for successfully overcoming these challenges and illustrate the application of these principles with real world examples. While these examples are drawn from specific large optical testing applications, they inform the problems associated with testing any large part to optical tolerances. Manufacturing today relies on micrometer level part performance. Fields such as energy and transportation are demanding higher tolerances to provide increased efficiencies and fuel savings. By looking at how the optics industry approaches sub-micrometer metrology, one can gain a better understanding of the metrology challenges for any larger part specified to micrometer tolerances. Testing large parts, whether optical components or precision structures, to optical tolerances is just like testing small parts, only harder. Identical with what one does for small parts, a metrologist tests large parts and optics in particular to quantify their mechanical properties (such as dimensions, mass, etc); their optical prescription or design (i.e. radius of curvature, conic constant, vertex location, size); and their full part shape. And, just as with small parts, a metrologist accomplishes these tests using distance measuring instruments such as tape measures, inside micrometers, coordinate measuring machines, distance measuring interferometers; angle measuring instruments such as theodolites, autocollimators; and surface measuring instruments including interferometers, stylus profilers, interference microscopes, photogrammetric cameras, or other tools. However, while the methodology may be similar, it is more difficult to test a large object for the simple reason that most metrologists do not have the necessary intuition. The skills used to test small parts or optics in a laboratory do not extrapolate to testing large parts in an industrial setting any more than a backyard gardener might successfully operate a farm. But first, what is a large part? A simple definition might be the part's size or diameter. For optics and diffuse surface parts alike, the driving constraint is ability to illuminate the part's surface. For reflective convex mirrors, large is typically anything greater than 1 meter. But, for refractive optics, flats or convex mirrors, large is typically greater than 0.5 meter. While a size definition is simple, it may be less than universal. A more nuanced definition might be that a large part is any component which cannot be easily tested in a standard laboratory environment, on a standard vibration isolated table using standard laboratory infrastructure. A micro-switch or a precision lens might be easily measured to nanometer levels under a microscope in a lab, but a power turbine spline or a larger telescope mirror will not fit under that microscope and may not even fit on the table.

Stahl, H. Philip↗

Modeling Deformable Linear Objects for Autonomous Robotic Outfitting of Lunar Surface Systems

This paper presents structural models of deformable linear objects (DLOs). DLOs are a subclass of deformable objects that encompasses common outfitting elements such as cables and ropes. Models are validated through hardware experiments, and integration in a robotic autonomy architecture for space environments is discussed. A persistent human presence on the lunar surface is one of the next major milestones in space exploration. This requires the development of robust extraplanetary construction technologies including structures and materials modeling and robotic systems. Previous robotic construction technology development has primarily focused on structural assembly, with significantly less focus on robotically performed outfitting tasks to instantiate subsystems providing power, data, life support, etc. These tasks involve manipulation of highly flexible elements, which are difficult to model, such as cable harnesses, ropes, and hoses. Robotic manipulation of DLOs, especially cable harnesses, is an active area of research as cable harnesses are essential for providing power and data to space assets. DLO models that can be used for robot manipulator trajectory generation are necessary for autonomous operation of lunar infrastructure. There are many proposed methods for modeling DLOs, and they primarily fall into three types: 1) discrete model-based, 2) continuum model-based, and 3) Neural Network-based. These types each have pros and cons, and the tradeoff between model accuracy and computational speed informs which type should be used. An understanding of this trade-off is imperative for real-time control of autonomous systems. High computational requirements reduce the speed of the model, making real-time control difficult, while accuracy is critical to preventing collisions. Discrete models, such as a mass-spring multibody representation, require relatively few calculations, and accuracy is directly tied to the step size of the discretization. Continuum models, such as a B-spline representation or a Cosserat rod model (a mix of continuous and discrete), are more informed of the structural properties of the cable and are much more accurate than a rigid body mass-spring model, but at significant computational cost. A Neural Network approach can provide an online solution with very few computational steps, but properly generating training data can be difficult and validation for an in-space application is not trivial. This paper explores the trade-off between different modeling approaches and compares accuracy and computational speed/complexity of the three types mentioned above. Model accuracy is evaluated using a cable in a static configuration. True cable shape is obtained using a depth camera for RGB images and point-cloud segmentation. The purpose of this experiment is to evaluate the trade-offs of different approaches to the DLO modeling problem. Understanding the tradeoffs between different cable modeling techniques paves the way for developing robotic control and planning architectures necessary for real-time manipulation of DLOs for lunar infrastructure outfitting. Real-time control is required for robotic systems to be able to actively manipulate a cable in a harsh environment where model and sensor errors compound, and environmental conditions can cause significant disturbances. Cable routing must be performed in areas with high density of objects/obstacles: through truss structures, near solar panels or mirror arrays, next to bundles of electrical equipment. Understanding the best way to plan and manipulate a cable without disrupting the environment or damaging the cable is imperative to robotic outfitting operations on the lunar surface.

Amy M Quartaro↗

An Efficient Single Frequency Ho:YLF Laser for IPDA Lidar Applications

A highly efficient, versatile, single frequency 2-micron pulsed laser can be used in a pulsed Differential Absorption Lidar (DIAL) / Integrated Path Differential Absorption (IPDA) instrument to make precise, high-resolution measurements to investigate sources and sinks of CO2. For a direct detection IPDA lidar, the desired 2 m Ho:YLF laser should generate 30-40 mJ pulses at the repetition rate of 100 to 200 Hz, with short pulse length (<100 ns) and better than 2% wall plug efficiency. A Tm fiber laser in-band pumped Ho:YLF laser has been developed to meet this technical challenge. This Ho:YLF laser is designed in a four mirror ring resonator with bow tie configuration, which helps to obtain high beam quality. It is end-pumped by a 40 W linearly polarized Tm fiber laser at 1.94μm. The resonator length is 1.10 meters with output coupler reflectivity at 45%. The laser crystal size is 3 x 3 x 60 mm (w, h, l) with a doping concentration of 0.5% Holmium. The laser beam and pump beam are mode-matched in the active medium. Thus, the pump and laser beams have the same confocal parameters. Mode-matching is also helpful for operating the laser in a single transverse mode. The laser beam waist is slightly less than 0.5 mm at the center of the laser crystal. Based on quasi-four level modeling, pump absorption and saturation depend on laser intensity. Laser amplification and saturation also depend on the pump intensity in the crystal. The laser is injection seeded to obtain the single frequency required by an IPDA lidar measurement. The seed beam is entered into the resonator through an output coupler. The laser is mounted on a water cooled optical bench for stable and reliable operation. The size of the optical bench is 22.16 x 9.20 x 1.25 inches. It is stiffened so that the laser can be operated in any orientation of the optical bench. This packaged Ho:YLF laser is designed for either mobile trailer or airborne platform operation. The engineering prototype Ho:YLF laser has been fully characterized to demonstrate laser performance. Figure 1 shows the laser output power as a function of pump power at different pulse repetition rates from 100 Hz to 333 Hz. The threshold of the laser is less than 14 W. The slope efficiencies are 28%, 40%, 41% and 43% for pulse repetition rates of 100, 200, 250 and 333 Hz, respectively. Maximum power increases with the pulse repetition rate. Output power of 4.2 W, 6 W, 6.7 W, and 7.7 W is achieved for pulse repetition rates of 100, 200, 250 and 333Hz, respectively. This represents the optical conversion efficiency of 16.7%, 22.4%, 23.7%, and 26.5% at these various pulse repletion rates. It is the most efficient and compact Ho:YLF laser demonstrated in the high pulse energy (>20mJ) and moderate pulse repetition rate (100's Hz) operation range. As shown in Figure 1, the maximum pulse energy at 100 Hz is 42 mJ. This is limited due to optical damage. The laser stability is characterized and found to be very stable. A relative pulse energy standard deviation of 2% was measured. The beam quality of the Ho:YLF was measured by a Spiricon infrared laser beam camera. Figure 2 shows the beam profile image of the laser. Both the X-profile of the beam (horizontal direction) and the Y-profile of the beam (vertical direction) are well fitted by a Gaussian profile. The qualitative beam quality measurement shows excellent beam quality in both axis. The M-square value for the laser beam is measured at 1.06 and 1.09 for the x and y axis respectively.-

Yu, J.↗