Search NASA⌕ Search

SEARCH · Search NASA

Results for “load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Ultrasonic wave-based structural health monitoring embedded instrument

Piezoelectric sensors and actuators are the bridge between electronic and mechanical systems in structures. This type of sensor is a key element in the integrity monitoring of aeronautic structures, bridges, pressure vessels, wind turbine blades, and gas pipelines. In this paper, an all-in-one system for Structural Health Monitoring (SHM) based on ultrasonic waves is presented, called Phased Array Monitoring for Enhanced Life Assessment. This integrated instrument is able to generate excitation signals that are sent through piezoelectric actuators, acquire the received signals in the piezoelectric sensors, and carry out signal processing to check the health of structures. To accomplish this task, the instrument uses a piezoelectric phased-array transducer that performs the actuation and sensing of the signals. The flexibility and strength of the instrument allow the user to develop and implement a substantial part of the SHM technique using Lamb waves. The entire system is controlled using configuration software and has been validated through functional, electrical loading, mechanical loading, and thermal loading resistance tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of planetary bearing load-sharing characteristics in wind turbine gearboxes

Abstract. In this paper, the planetary load-sharing behavior and fatigue life of different wind turbine gearboxes when subjected to rotor moments are examined. Two planetary bearing designs are compared – one design using cylindrical roller bearings with clearance and the other design using preloaded tapered roller bearings to support both the carrier and planet gears. Each design was developed and integrated into a 750 kW dynamometer tests, the loads on each planet bearing row were measured and compared to finite-element models. Bearing loads were not equally shared between the set of cylindrical roller bearings supporting the planets even in pure torque conditions, with one bearing supporting up to 46 % more load than expected. A significant improvement in planetary bearing load sharing was demonstrated in the gearbox with preloaded tapered roller bearings with maximum loads 20 % lower than the gearbox with cylindrical roller bearings. Bearing life was calculated with a representative duty cycle measured from field tests. The predicted fatigue life of the eight combined planet and carrier bearings for the gearbox with preloaded tapered roller bearings is 3.5 times greater than for the gearbox with cylindrical roller bearings. The influence of other factors, such as carrier and planet bearing clearance, gravity, and tangential pin position error, is also investigated. The combined effect of gravity and carrier bearing clearance was primarily responsible for unequal load sharing. Reducing carrier bearing clearance significantly improved load sharing, while reducing planet clearance did not. Normal tangential pin position error did not impact load sharing due to the floating sun design of this three-planet gearbox.

17 WIND ENERGY↗

Study of keV radiation properties of Mo and Ti X-pinch plasma sources using a pinhole transmission grating spectrometer

The properties of keV x-ray radiations from Mo and Ti X-pinch plasma sources at the current of 800 kA were investigated by a pinhole transmission grating spectrometer. The spectrometer was characterized by a high linear dispersion rate (2.9 A/mm), and from its time-integrated diffraction images, rich information about the X-pinch sources (e.g., source number, source size, and absolute spectra) could be obtained. Multiple hot spots were produced in all the Mo tests with loads made of two or four 25 mum wires with or without a shunt wire, and obvious increases both in the radiation intensity and in the source size around the spectral region of 2.6 keV were observed. In Ti X-pinch tests, a single keV x-ray burst with a source size of approx200 mum and a time duration of approx200 ps in full width at half maximum was obtained using a load made of two 50 mum wires plus a shunt wire. The intensity of x-rays decreased sharply from approx10{sup 11} photon eV{sup -1} sr{sup -1} at 1 keV to approx10{sup 8} photon eV{sup -1} sr{sup -1} at 4 keV. The energy-dependent source size in the band of 1-4 keV is less than 100 mum and seemed to shrink quickly as x-ray energy increases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multispectral impedance determination under dynamic load conditions

Impedance testing devices, circuits, systems, and related methods are disclosed. A method may include exciting a device coupled to a load, and capturing a response of the device. The method may further include adjusting the response based on an estimated load response of the device, and estimating an impedance of the device based on the adjusted response.

Christophersen, Jon P.↗

Opportunities for Open Automated Demand Response in Wastewater Treatment Facilities in California - Phase II Report. San Luis Rey Wastewater Treatment Plant Case Study

This case study enhances the understanding of open automated demand response opportunities in municipal wastewater treatment facilities. The report summarizes the findings of a 100 day submetering project at the San Luis Rey Wastewater Treatment Plant, a municipal wastewater treatment facility in Oceanside, California. The report reveals that key energy-intensive equipment such as pumps and centrifuges can be targeted for large load reductions. Demand response tests on the effluent pumps resulted a 300 kW load reduction and tests on centrifuges resulted in a 40 kW load reduction. Although tests on the facility?s blowers resulted in peak period load reductions of 78 kW sharp, short-lived increases in the turbidity of the wastewater effluent were experienced within 24 hours of the test. The results of these tests, which were conducted on blowers without variable speed drive capability, would not be acceptable and warrant further study. This study finds that wastewater treatment facilities have significant open automated demand response potential. However, limiting factors to implementing demand response are the reaction of effluent turbidity to reduced aeration load, along with the cogeneration capabilities of municipal facilities, including existing power purchase agreements and utility receptiveness to purchasing electricity from cogeneration facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseline LAW Glass Formulation Testing

The major objective of the baseline glass formulation work was to develop and select glass formulations that are compliant with contractual and processing requirements for each of the LAW waste streams. Other objectives of the work included preparation and characterization of glasses with respect to the properties of interest, optimization of sulfate loading in the glasses, evaluation of ability to achieve waste loading limits, testing to demonstrate compatibility of glass melts with melter materials of construction, development of glass formulations to support ILAW qualification activities, and identification of glass formulation issues with respect to contract specifications and processing requirements.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hybrid Zircex Hydrochlorinator

This project was driven by the desire to create easier and faster ways to load Advanced Test Reactor (ATR) Fuel Elements into the Hybrid Zircex hydrochlorinator. The primary requirements for this project were to minimize the potential release of radioactive contamination, minimize maintenance operations to replace or remove the lid seal, and allow for remote usage. Three preliminary designs were made. These designs allow ATR fuel elements to be loaded into the hydrochlorinator more efficiently while fulfilling the requirements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multispectral impedance determination under dynamic load conditions

Impedance testing devices, circuits, systems, and related methods are disclosed. A Device Under Test (DUT) is excited with a multispectral excitation signal for an excitation time period while the DUT is under a load condition from a load operably coupled to the DUT. A response of the DUT is sampled over a sample time period. The sample time period is configured such that it includes an in-band interval during the excitation time period and one or more out-of-band intervals outside of the in-band interval. A response of the DUT to the load condition during the in-band interval is estimated by analyzing samples of the response from the one or more out-of-band intervals. Adjusted samples are computed by subtracting the estimated load response during the in-band interval from the samples from the in-band interval. An impedance of the DUT is estimated by analyzing the adjusted samples.

Christophersen, Jon P.↗

Degradation processes in high-temperature creep of cast cobalt-based superalloys

Highlights: • Creep degradation processes in Nb or Ta strengthened cobalt-based superalloys were investigated. • CoNb superalloy exhibits longer creep life compared to CoTa superalloy. • Creep fracture ductility of CoTa superalloy is higher than CoNb superalloy. • Low fracture ductility of CoNb superalloy resulted from a premature fracture. • Ductile creep fracture in CoTa superalloy is caused by instability of dislocation microstructure. - Abstract: Degradation processes in high-temperature creep of two cast high-chromium cobalt-based superalloys strengthened by niobium and tantalum for use in the glass industry were analysed via various experimental techniques. Constant load creep tests were conducted at 900, 950 and 1000 °C in a tensile stress range from 40 to 80 MPa. It was found that the CoNb superalloy possesses considerably longer creep life compared to the CoTa superalloy under the same loading conditions. Conversely, the creep ductility of the fractured specimens shows the opposite order of the creep life. The creep behaviour of both superalloys obeys the Monkman-Grant formula indicating that the creep deformation mechanism and fracture processes are mutually interlinked. The homogeneously distributed creep damage of the CoNb superalloy is closely connected with primary carbides and is predominantly initiated either as interface decohesion between the carbide/matrix and carbide eutectics/matrix or by breakage of bulk M{sub 23}C{sub 6} carbides. The dominant type of creep damage in the CoTa superalloy is localized breakage of M{sub 23}C{sub 6} carbides in close proximity of the fracture path. The final brittle fracture in the CoNb superalloy occurs via relatively fast propagation of the longest cracks after the ultimate state of damage is reached. Due to premature fracture, the inherent creep ductility of the CoNb matrix is not exhausted. The final ductile transgranular creep fracture of the CoTa superalloy is caused by a local strain-induced instability of the dislocation microstructure leading to a loss of an external section of specimen (necking).

36 MATERIALS SCIENCE↗

Reducing Internal Resistance in Activated Carbon Supercapacitors via Exfoliated Coal-Derived Graphene Additive

Low equivalent series resistance (ESR) is critical for high-rate energy storage devices (e.g., supercapacitors), and graphene is a promising additive for reducing ESR in carbon-based supercapacitor electrodes. However, graphene can be costly and difficult to produce at scale. This study investigates the addition of graphene, produced through electrochemical exfoliation of domestic coal-derived graphite, in activated carbon-based supercapacitors. The coal-derived graphene was incorporated at varying weight loadings and tested in symmetric supercapacitors with aqueous electrolytes. ESR was evaluated using both direct current internal resistance (DCIR) and electrochemical impedance spectroscopy (EIS) measurements. DCIR measurements revealed ESR reductions of ∼34%, ∼18%, and ∼21% at 3, 5, and 10 wt % loadings, respectively, compared to the baseline (0 wt %) of ∼0.54 Ω. These results were further confirmed by EIS measurements. Correspondingly, power density increased by ∼52%, ∼27%, and ∼35% at 3, 5, and 10 wt % loadings relative to the baseline (∼29 kW/kg). Additionally, the electrodes exhibited moderate increases in specific capacitance and energy density, along with stable cycling performance (capacitance retention above 85% after 100,000 cycles) and capacitive behavior (α = 0.95−0.97), suggesting favorable charge transfer kinetics. These findings highlight the potential of exfoliated coal-derived graphene as an effective additive for supercapacitor electrodes.

capacitors↗

Low temperature water-gas shift: Optimization of K loading on Pt/m-ZrO 2 for enhancing CO conversion

Previous work showed that alkali doping of Pt/ZrO 2 significantly improved the LT-WGS rate. This improvement was caused by an acceleration in the rate of formate decomposition, the rate limiting step of an associative mechanism, through electronically weakening the CH bond. In this study, the effects that potassium loading on Pt/ZrO 2 have on the rate of LT-WGS and the strength of the CH bond in intermediate formate species are explored. Catalysts were investigated using in-situ DRIFTS, TPR-MS, TPD, EXAFS, and catalyst testing. Here, loadings of 1.7 wt.% potassium or higher shifted the formate ν(CH) band to significantly lower wavenumbers, indicating weakening of the bond. For the optimal loading, 2.6 wt.% K, the formate CH bond was significantly weakened, and the surface of Pt nanoparticles remained largely uncovered. However, loadings of 3.4 wt. % and above blocked the surface of the platinum nanoparticles. This, in addition to an increasing average Pt0 cluster size, hindered platinum from assisting in dehydrogenation of formate during steam promoted formate decomposition occurring in LT-WGS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GeoMelt{sup R} In-Container Vitrification (ICV){sup TM} for Fukushima Daiichi Water Treatment Secondary Wastes - 20212

The Japanese government is supporting development work implemented jointly by Veolia subsidiaries Kurion Japan, K.K., Veolia Nuclear Solutions (VNS), Inc., and Veolia Nuclear Solutions Federal Services, LLC for treating radioactive waste generated from Fukushima Daiichi Nuclear Power Station (NPS) water treatment using the GeoMelt{sup TM} In-Container Vitrification (ICV){sup TM} technology. The initial work consisted of glass formulation and engineering-scale testing which was completed in 2018, in the frame of an IRID (International Research Institute for Nuclear Decommissioning) program as part of a project subsidized by Japan's Ministry of Economy, Trade and Industry (METI). The Fukushima Daiichi NPS Mid- and Long-Term Road-map requires investigation of methods to stabilize solid wastes (and to immobilize radioisotopes in the wastes) generated as a result of emergency response and decommissioning activities. Cooling water treatment has resulted in a significant amount of solid and slurry secondary wastes (mostly adsorbents and ion-exchange materials) which will require processing at some point. GeoMelt{sup R} ICV{sup TM} is a joule-heated melter technology which uses a refractory-lined single-use container combining the melter and disposal container. There is no pouring required nor concerns with refractory corrosion which allows the process to accommodate a wide range of waste chemistries and high waste loadings. The testing described here consisted of three engineering-scale melts, each processing between 212 kg and 240 kg of waste simulants, glass formers, and non-radioactive cesium (Cs) and strontium (Sr) tracers. Continuous isokinetic stack sampling of off-gas emissions was performed for each test in order to calculate Cs and Sr retention in the glass wasteform. Single-pass retention of Cs in the final glass wasteform ranged from 91.46 to 99.30%, and single-pass retention of Sr ranged from 99.76 to 100%. Planned particulate recycle will increase these retention levels. Melt 1 processed a mixture of KUR-EH (a zeolite-based ion-exchange material), simulated Advanced Liquid Processing System (ALPS) Carbonate and Iron Slurries, and glass additives. Melt 2 processed a mixture of KUR-EH, KUR-TSG (a titanate-based adsorbent), and glass additives. Melt 3 processed a mixture of KUR-EH, simulated barium sulfate/iron ferrocyanide sludge (AREVA sludge), and glass additives. Waste loadings for these melts ranged from 70 weight percent (wt%) to 82 wt%. Vitrification produces a waste form much denser than the stored water treatment secondary waste wastes, resulting in significant volume reduction. Volume reductions for the three tests ranged from 74 to 79 vol%. Vitrification produces a chemically durable wasteform. Pacific Northwest National Laboratory (PNNL) tested three glass samples from each engineering-scale melt) by the Materials Characterization Center 1 (MCC-1) test, an international standard leach test of the chemical durability of nuclear waste glasses. PNNL also obtained one U.S. reference glass (EA Glass) and two Japan reference glasses P0798) and tested these under the same MCC-1 conditions (90 deg. C, 10 m-1, DIW, and 7, 14, 28-day) as the GeoMelt{sup R} ICV{sup TM} glasses. The GeoMelt{sup R} ICV{sup TM} glasses exhibited lower total normalized releases and 14- to 28-day normalized release rates than the three reference glasses. These results suggest that the GeoMelt{sup R} ICV{sup TM} glasses have durabilities on par with high-level waste glasses under standard test conditions. Post-melt process sampling and analysis indicated no Cs migration into the melter refractory materials and very little deposition of Cs or Sr onto the melter hood or off-gas piping internals. The results of the testing indicated good Cs retention in the glass, high volume reduction and waste loadings, and excellent chemical durability. These factors are important to minimize treatment costs and to protect workers and the environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-carbon fuels for spark-ignited engines: A comparative study of compressed natural gas and liquefied petroleum gas on a CFR engine with exhaust gas recirculation

Decades of work on low-carbon fuels have established their potential for substantial emissions reductions; however, their adoption is still limited by infrastructure concerns and engine efficiency deficits. As infrastructures have begun to evolve, research on strategies that maximize engine efficiency through interactions with fuel properties must also now take center place. This paper compares the performance, emissions, and combustion characteristics of two forefront low-carbon fuels: compressed natural gas (CNG) and liquefied petroleum gas (LPG) in a cooperative fuel research (CFR) engine over a range of compression ratios and engine loads. The effects of exhaust gas recirculation (EGR), end-gas auto-ignition, and a novel combustion control tool, the combustion intensity metric (CIM), were also evaluated at different stoichiometric engine operating conditions. In comparison to LPG, CNG operation demonstrated an extended knock-free regime, allowing engine operation at higher engine loads and compression ratios, but LPG operation exhibited enhanced combustion characteristics with higher peak pressures and faster apparent heat release rates (AHRR). LPG operation achieved higher brake thermal efficiencies and lower equivalent CO 2 emissions compared to CNG operation at the tested engine loads and compression ratios. LPG demonstrated significantly higher EGR tolerance limits compared to CNG, with a maximum of 28% EGR rate, compared to 23% for CNG. This improved EGR dilution tolerance was responsible for a 90% reduction in NOx emissions for LPG compared to a maximum of 70% with CNG. EGR dilution also exhibited more effective knock mitigation potential with LPG, suppressing knock intensity values by up to 98% and transitioning the engine operation towards normal combustion from heavy knocking conditions. As a result, the CIM was found to decrease burn durations and improve the quality of combustion by controlling the desired fraction of end-gas auto-ignition.

33 ADVANCED PROPULSION SYSTEMS↗

Aging behavior of polymeric solar absorber materials: Aging on the component level

Within this study, the aging behavior of a PPE + PS absorber material was investigated on the absorber component level. To indicate aging, characteristic mechanical values were determined by indentation tests of specimens taken from components and exposed to laboratory aging (140 C in air, 80 C in water) and service near outdoor aging conditions (stagnation in northern climate). In addition to the mechanical tests, the unaged and aged specimens were also characterized thermo-analytically via differential scanning calorimetry (DSC). The results indicate that reductions in both characteristic mechanical values of the indentation tests, i.e., load of the first transition and ultimate indentation, reflect at least some physical aging although chemical aging may also be of importance based on previous analytical investigations of laboratory aged polymer films. While laboratory aging in air at 140 C and service exposure at a test facility in Oslo (N) under stagnation conditions led to a significant reduction in the mechanical indentation resistance, no influence of laboratory aging in water at 80 C on the mechanical behavior of the absorber sheet was found. Depending on the ultimate failure criterion applied (reduction of characteristic mechanical values to 80% and 50%, respectively), the technical service life found for hot air laboratory and stagnation service conditions was found to be less than 51 and 159 h, respectively. As these durations are significantly below the estimated stagnation conditions accumulated in the desired operation lifetime for such a collector, the PPE + PS type investigated does not seem to be a proper material candidate for solar thermal absorbers. Finally, based on the results obtained, a relation between laboratory aging time in air at 140 C and cumulated irradiation energy during exposure on the test facility in Oslo was established. (author)

14 SOLAR ENERGY↗

Design of a Compact Fatigue Tester for Testing Irradiated Materials

A compact fatigue testing machine that can be easily inserted into a hot cell for characterization of irradiated materials is beneficial to help determine relative fatigue performance differences between new and irradiated material. Hot cell use has been carefully considered by limiting the size and weight of the machine, simplifying sample loading and test setup for operation via master-slave manipulator, and utilizing an efficient design to minimize maintenance. Funded from a US-Japan collaborative effort, the machine has been specifically designed to help characterize titanium material specimens. These specimens are flat cantilevered beams for initial studies, possibly utilizing samples irradiated at other sources of beam. The option to test spherically shaped samples cut from the T2K vacuum window is also available. The machine is able to test a sample to $10^7$ cycles in under a week, with options to count cycles and sense material failure. The design of this machine will be presented along with current status.

Hartsell, Brian↗

Transient Modelling of HTGR Thermal Load Follow in Modelica

The ability of nuclear power plants to load follow electrical power demand is particularly important as we move to higher variable renewable (VRE) energy production on low carbon energy grids. High temperature gas reactors (HTGRs) are capable of load following by adjusting thermal output, but their high temperatures and thermal inertia significantly impact the power transients they are able to follow. To aid investigation into new integrated energy systems with advanced reactors, it is necessary to have an open-source transient model of a full HTGR primary and secondary. This paper introduces two new open-source models for a HTGR and corresponding balance of plant (BOP) written for the HYBRID library developed at Idaho National Laboratory. A transient thermal load follow test case was taken by the work from Brits et al. to benchmark our open-source model against transient operation results from other proprietary codes that exist. The control scheme for the two new models in combination is discussed and a comparison of the response in transient load follow between the two codes performed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ion Exchange Testing with SRF Resin FY2012

Ion exchange using spherical resorcinol-formaldehyde (SRF) resin has been selected by the U.S. Department of Energy’s Office of River Protection (DOE-ORP) for use in the Pretreatment Facility (PTF) of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and for potential application in at-tank deployment. Numerous studies have shown SRF resin to be effective for removing 137Cs from a wide variety of actual and simulated tank waste supernatants (Adamson et al. 2006; Blanchard et al. 2008; Burgeson et al. 2004; Duignan and Nash 2009; Fiskum et al. 2006a; Fiskum et al. 2006b; Fiskum et al. 2006c; Fiskum et al. 2007; Hassan and Adu-Wusu 2003; King et al. 2004; Nash et al. 2006). Prior work at the Pacific Northwest National Laboratory (PNNL) has focused primarily on the loading behavior for 4 to 6 M Na solutions at 25 to 45°C. Recent proposed changes to the WTP ion exchange process baseline indicate that loading may include a broader range of sodium molarities (0.1 to 8 M) and higher temperatures (50°C) to alleviate post-filtration precipitation issues. This report discusses ion exchange loading kinetics testing activities performed in accordance with Test Plan TP-WTPSP-002, Rev. 3.0, which was prepared and approved in response to the Test Specification 24590 PTF-TSP-RT-09-002, Rev. 0 (Lehrman 2010) and Test Exception 24590 PTF TEF RT-11-00003, Rev. 0 (Meehan 2011). This testing focused on column tests evaluating the impact of elevated temperature on resin degradation over an extended period of time and batch contacts evaluating the impact on Cs loading over a broad range of sodium concentrations (0.1 to 5 M). These changes may be required to alleviate post-filtration precipitation issues and broaden the data range of SRF resin loading under the conditions expected with the new equipment and process changes.

Hanford Tank Waste Treatment and Immobilization Pl↗