Search NASA⌕ Search

SEARCH · Search NASA

Results for “lumped parameter model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Modeling of electrodes and implantable pulse generator cases for the analysis of implant tip heating under MR imaging

Purpose: The authors’ purpose is to model the case of an implantable pulse generator (IPG) and the electrode of an active implantable medical device using lumped circuit elements in order to analyze their effect on radio frequency induced tissue heating problem during a magnetic resonance imaging (MRI) examination. Methods: In this study, IPG case and electrode are modeled with a voltage source and impedance. Values of these parameters are found using the modified transmission line method (MoTLiM) and the method of moments (MoM) simulations. Once the parameter values of an electrode/IPG case model are determined, they can be connected to any lead, and tip heating can be analyzed. To validate these models, both MoM simulations and MR experiments were used. The induced currents on the leads with the IPG case or electrode connections were solved using the proposed models and the MoTLiM. These results were compared with the MoM simulations. In addition, an electrode was connected to a lead via an inductor. The dissipated power on the electrode was calculated using the MoTLiM by changing the inductance and the results were compared with the specific absorption rate results that were obtained using MoM. Then, MRI experiments were conducted to test the IPG case and the electrode models. To test the IPG case, a bare lead was connected to the case and placed inside a uniform phantom. During a MRI scan, the temperature rise at the lead was measured by changing the lead length. The power at the lead tip for the same scenario was also calculated using the IPG case model and MoTLiM. Then, an electrode was connected to a lead via an inductor and placed inside a uniform phantom. During a MRI scan, the temperature rise at the electrode was measured by changing the inductance and compared with the dissipated power on the electrode resistance. Results: The induced currents on leads with the IPG case or electrode connection were solved for using the combination of the MoTLiM and the proposed lumped circuit models. These results were compared with those from the MoM simulations. The mean square error was less than 9%. During the MRI experiments, when the IPG case was introduced, the resonance lengths were calculated to have an error less than 13%. Also the change in tip temperature rise at resonance lengths was predicted with less than 4% error. For the electrode experiments, the value of the matching impedance was predicted with an error less than 1%. Conclusions: Electrical models for the IPG case and electrode are suggested, and the method is proposed to determine the parameter values. The concept of matching of the electrode to the lead is clarified using the defined electrode impedance and the lead Thevenin impedance. The effect of the IPG case and electrode on tip heating can be predicted using the proposed theory. With these models, understanding the tissue heating due to the implants becomes easier. Also, these models are beneficial for implant safety testers and designers. Using these models, worst case conditions can be determined and the corresponding implant test experiments can be planned.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Universal Two-Phase Convection Heat Transfer Correlations for Cryogenic Pipe Chilldown

This paper presents a set of universal two-phase convection heat transfer correlations for modeling boiling heat transfer during pipe chilldown fit over the widest available range of cryogenic fluids and thermodynamic conditions. The correlations improve upon prior correlations that were developed separately for liquid nitrogen (LN2) and liquid hydrogen (LH2) pipe quenching datasets. The new correlations include equations to calculate the single-phase vapor heat transfer, film boiling heat transfer, transition boiling heat transfer, nucleate boiling heat transfer, single-phase liquid heat transfer, bulk vapor temperature during high quality film boiling, Leidenfrost temperature, critical heat flux, critical heat flux temperature, and the onset of nucleate boiling temperature. The correlations were validated against LH2, LN2, liquid methane, liquid oxygen, and liquid argon pipe quenching datasets. The eight datasets cover the following parameter ranges: pipe lengths of 0.1 to 6.5m; outer pipe diameters of 12.7 to 25.4 mm; pipe wall thicknesses from 0.51 to 1.64 mm; flow directions of upward, downward, and horizontal; gravity levels of 1g and 0g±0.01g. A numerical model assumes homogeneous mixing between the vapor and liquid and implicitly integrates the coupled energy equations for the pipe and fluid, as well as continuity for the fluid. The model was used to estimate the equilibrium quality and fluid mass accumulation along the pipes during chilldown from estimates of the fluid-pipe heat transfer extracted from temperature measurements. The correlations can be implemented in lumped parameter codes such as SINDA/FLUINT and the Generalized Fluid System Simulation Program (GFSSP) to improve the accuracy of chilldown time and chilldown boiloff mass predictions. Such predictions are useful for designing ground or in-space cryogenic liquid transfer systems.

Universal Correlations↗

Predictive Simulation of Gas Adsorption in Fixed-Beds and Limitations due to the Ill-Posed Danckwerts Boundary Condition

The 1-D axially dispersed plug flow model is a mathematical model widely used for the simulation of adsorption processes. Lumped mass transfer coefficients such as the Glueckauf linear driving force (LDF) term and the axial dispersion coefficient are generally obtained by fitting simulation results to the experimental breakthrough test data. An approach is introduced where these parameters, along with the only free parameter in the energy balance equations, are individually fit to specific test data that isolates the appropriate physics. It is shown that with this approach this model provides excellent simulation results for the C02 on zeolite SA sorbent/sorbate system; however, for the H20 on zeolite SA system, non-physical deviations from constant pattern behavior occur when fitting dispersive experimental results with a large axial dispersion coefficient. A method has also been developed that determines a priori what values of the LDF and axial dispersion terms will result in non-physical simulation results for a specific sorbent/sorbate system when using the one-dimensional axially dispersed plug flow model. A relationship between the steepness of the adsorption equilibrium isotherm as indicated by the distribution factor, the magnitude of the axial dispersion and mass transfer coefficient, and the resulting non-physical behavior is derived. This relationship is intended to provide a guide for avoiding non-physical behavior by limiting the magnitude of the axial dispersion term on the basis of the mass transfer coefficient and distribution factor.

Knox, James Clinton↗

JGCRI/hydro-emulator

The hydrological emulator (HE) was built to mimic complex global hydrological models (GHMs) at a range of spatial scales. The HE was written in MATLAB and utilizes a genetic algorithm to calibrate the a, b, c, d, m parameters from the ABCD runoff algorithm to observed runoff from GHMs when forced by the same climate data. The HE employs two methods to choose from when processing basin data: lumped (by basin) and distributed (gridded). Both methods can be evaluated using the built-in Kling-Gupta efficiency as a measure of model performance when compared to the outputs from the more complex GHM. Testing shows that the HE is 7 orders of magnitude faster then the widely used Variable Infiltration Capacity (VIC) GHM.

Vernon, Chris↗

Parameter extraction approaches for compact modeling of thermoelectric modules

Thermoelectric (TE) cooling has experienced rapid advancements with the foundational understanding of TE materials. TE modules, compact and lightweight devices, have become the prevalent approach for implementing TE technologies. Accurately quantifying TE physical parameters (Seebeck coefficient α, thermal conductivity κ, and thermal resistance ρ) is challenging due to the dynamic temperature changes in operation. Furthermore, extracting lumped property parameters is crucial for designing energy systems using TE modules. Existing research has several limitations, such as lack of comparative analysis between prevalent formulae, reliance on potentially inaccurate vendor-supplied data, disregard for fundamental assumptions, and absence of empirical measurements. Further, this study addresses these gaps by conducting TE material characterization, comparing three existing formulae using vendor datasheets, designing a laboratory test facility for model validation and refinement, and outlining a structured data extraction procedure. The study's novelty lies in multiple key contributions: (1) a detailed comparative analysis of existing formulae for extracting TE property parameter; (2) executing experimental work in a laboratory setting to validate the model and elucidate its limitations; (3) highlighting potential risks; (4) clarifying possible assumptions from both material and engineering perspectives; and (5) considering temperature differential impacts. This comprehensive approach addresses the current research gaps and provides valuable insights into the design and application of TE modules in various energy systems.

36 MATERIALS SCIENCE↗

Semi-coupled flow and thermal analysis of the field joint during rapid pressurization of the redesigned solid rocket motor

A transient, semi-coupled, multi-dimensional thermal and flow analysis methodology was developed to predict the thermal/gas dynamic conditions in the field joint region of the Redesigned Solid Rocket Motor (RSRM). Transient temperature response, pressure history, and combustion gas flow rate (within the field joint region), were of principle interest, in the course of this study. The thermal environment in the field joint was modeled using SINDA, a finite difference based thermal network analyzer. The combustion gas flow boundary condition was generated using the FLAP code; this code performs a transient, lumped-parameter, control volume analysis to solve the mass, momentum, and energy conservation equations. The FLAP computer code was modified to account for erosion of the NBR insulation material, following ignition. An independent grid sensitivity study was conducted to determine an appropriate grid distribution near the wall. The predicted results, obtained using an optimum grid distribution and computer generated flow boundary condition, were compared with subscale test data.

Ghaffarian, Benny↗

Tracking Radioactive Isotopes in HVAC and Application for Hot Cell Analyses - 20155

In recent years, the surge in the number of isotope production facilities under design has increased the need to analyze isotope migration in facility Heating, Ventilation, and Air Conditioning (HVAC) during normal operations and accident scenarios. These facilities are used to produce isotopes for medical, security, and industrial applications and as such are subject to license and regulatory requirements 10CFR20, 10CFR30, 10CFR50, and 10CFR70. GOTHIC, a general-purpose thermal-hydraulics software package, includes the ability to model isotopic tracers, radioactive decay and isotope migration as well as HEPA and charcoal filters for isotope retention. A GOTHIC model was developed by Zachry Nuclear Engineering (ZNE) to examine the effect of negative room pressure, HEPA filtration, and HVAC fluctuations on radiation areas, hot cells and gloveboxes. Radioactive tracers were used to simulate the concentration of spills within contaminated areas, track the migration of isotopes of interest, and determine the isotopic retention and buildup on facility HEPA filters. A variety of isotopes with concern to dose (e.g., Kr-85, Sr-90, I-131, etc.), including their decay and progeny, are included in the analysis. Negative pressures are maintained in the regions of interest by a representative central HVAC system equipped with a volumetric fan that exhausts to the environment after a series of isolation valves and HEPA filters. GOTHIC is an industry trusted tool for providing engineering solutions for a variety of applications, including fission product tracking, aerosol and particulate transport and ventilation assessments. The software provides an integrated analysis environment that includes a graphical user interface (GUI) for constructing analysis models, a numerical solver that includes parallel processing capabilities and a post-processor for evaluating simulation results. It solves the conservation equations for mass, momentum and energy for multicomponent, multi-phase flow in lumped parameter and multi-dimensional geometries (1, 2, or full 3D), including the effects of turbulence, diffusion and buoyancy. It has been developed and maintained under a Quality Assurance program in compliance with the requirements of 10CFR50 Appendix B and applicable portions of ASME NQA-1 since 1995. GOTHIC has been used for assessing both forced and natural convection conditions for a wide range of applications, including: - Tracking concentration of hazardous gases and chemicals for habitability and safety assessments - Determining ventilation and filtration requirements and optimizing location and arrangement of these systems - Room heat-up, including diverse and Flexible coping strategies for Extended Loss of AC Power (FLEX/ELAP) - Equipment Qualification (EQ) A distinctive feature of GOTHIC is the ability to track many different fields/substances in a simulation, including user defined tracer elements, in the liquid, vapor and droplet fields as well as surfaces and filters. This capability allows GOTHIC to model fission product transport and release or the removal of particulates or harmful toxins from exhaust gases using a spray scrubber or other types of filtration systems. GOTHIC also includes models for engineered equipment, such as fans, filters, charcoal filters, dryers/demisters, dampers, etc. The aerosols and other filtered material are removed or accumulated in these components. The range of aerosol and radiological applications that GOTHIC has been used for includes: - Source Term: Primary Coolant (Equilibrium) Activity; Non-Water Coolant Source/Leakage. - Conditions for Iodine Re-evolution: Sump/Suppression Pool Conditions and pH; - RWST Conditions and pH. - Isotope Removal Mechanisms: Containment Sprayed and Unsprayed Region Mixing; Charcoal Filter Heating due to Iodine decay. - Radionuclide Transport and Decay: Post-LOCA Release in containment; Transport between connected Compartments and vent systems; Groundwater transport of radionuclides. - Non-Newtonian Fluid modeling for sludge, waste tanks, etc. ADAMS ML071581053 (titled 'Best Practice Guidelines for the use of CFD in Nuclear Reactor Safety Applications') poses guidelines for applying single phase CFD codes in nuclear reactor safety problems and GOTHIC is listed as a 'tool for 3D flows' and 'dispersal and deposition of radionuclides.' The Nuclear Quality Assurance (NQA) pedigree of GOTHIC is an important aspect for applications in the nuclear industry. The fundamental tracer models (convective transport, molecular and turbulent diffusion, removal mechanisms, etc.) have been verified using analytical solutions and validated against applicable separate effects tests. Also, GOTHIC has been benchmarked to many integrated effects tests, including Phebus FP (Fission Product). GOTHIC gives good agreement for the buildup and decay of fission products in Phebus Test 3. The model developed by ZNE demonstrates GOTHIC's applicability and acceptability for use in analyzing the migration and retention of radioactive isotopes and their progeny in normal operation and accident scenario analyses for isotope production facilities, hot cells, and gloveboxes. The tracer activities calculated by GOTHIC can then be used in downstream radiation transport and shielding codes like RADTRAD-NAI{sup C}, MCNP{sup R}, and MicroShield{sup R} to determine on-site and of-site doses. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Galactic disks, infall, and the global value of Omega

Stringent limits on the current rate of infall of satellite systems onto spiral galaxies are set on the basis of the thinness and coldness of Galactic disks. For infalling satellites on isotropically oriented circular orbits, it is shown that, due to scattering, the thermal energy gain of the disk exceeds the satellite energy loss from dynamical friction by a factor of 1.6, with 25 percent deposited in z motion and 75 percent in planar motions. It is found that no more than 4 percent of the Galactic mass inside the solar radius can have accreted within the last 5 billion years, or else its scale and its Toomre Q-parameter would exceed observed values. In standard cold-dark-matter-dominated models for the growth of structure with Omega sub tot of 1, the mass accreted in dark matter lumps rises faster than t exp 2/3 and would exceed 28 percent in the last 5 Gyr. It is proposed that heating from satellite infall accounts for a substantial fraction of the increase of velocity dispersion and scale height with age that is observed in the Galaxy.

Toth, G.↗

Modeling of a Stewart Platform for Analyzing One Directional Dynamics for Spacecraft Docking Operations

A one-directional dynamic model of a Stewart Platform was developed to assist NASA in analyzing the dynamic response in spacecraft docking operations. A simplified mechanical drawing was created, capturing the physical structure's main features. A simplified schematic diagram was developed in a lumped mass model from the mechanical drawing. Three differential equations were derived according to the schematic diagram. A Simulink diagram was created using MATLAB to represent the three equations. System parameters, including spring constants and masses, are derived in detail from the physical system. The model can be used for further analysis via computer simulation in predicting dynamic response in its main docking direction, i.e., up-and-down motion.

Stewart Platform↗

A general method for dynamic analysis of structures overview

The presented research deals with the development of a dynamic analysis method for structural systems. The modeling approach is essentially a finite element method in the sense that the structure is divided into n elements. An element is defined as any structural unit whose degree of freedom (dofs) can be categorized as either interface or non-interface dofs. An element could be a fundamental unit such as a rod, a beam, a plate etc., or it could be an entire structural component. Furthermore, the parameters for the element could be distributed or lumped. The choice of elements is totally arbitrary and is a matter of user convenience. In particular, issues of accuracy and convergence do not enter on the level of example that bookkeeping is reduced to a minimum. Each element is modeled using a set of interface constraint modes (ICM) combined with a set of interface restrained normal models (IRNM). The next step is the solution of the system eigenvalue problem. The procedure calls for the sequential solution of a number of small eigenvalue problems based on a truncation principle for IRNM. In addition, the form of these eigenvalue problems is very simple such that an escalator type of eigenvalue problem solver can be used which is extremely cost-effective and fast.

Engels, Remi C.↗

Chemical Kinetics of the Autoxidation of Poly(ethylenimine) in CO 2 Sorbents

The oxidative degradation rates of a CO 2 sorbent composed of a mesoporous alumina impregnated with poly- (ethylenimine) (PEI) are measured under systematically varied conditions and a reaction rate law is created. Good agreement is shown between the rate of oxidation obtained via in situ calorimetric heat measurement during oxidative degradation reactions and the loss of CO 2 capture performance presented as amine efficiency (mol CO 2 /mol amine). PEI mass loss and elemental composition are tracked over the course of the reaction and used in conjunction with the oxidation rate measurements to shed insight into the oxidation reaction(s). These data, in combination with measurements of the heat of reaction, suggest a common reaction set across the range of temperatures, oxygen concentrations, and sorbent compositions tested. The data are consistent with the basic autoxidation scheme (BAS), the accepted mechanism of autoxidation of aliphatic polymers. We propose a lumped kinetic model to describe the oxidation reaction set and estimate an activation energy of 105 kJ/mol and an oxygen reaction order of 0.5–0.7 from the data accordingly. Furthermore, these parameters can be incorporated into process cycle models to estimate the material lifetime, a critical uncertainty in the deployment of DAC technologies.

36 MATERIALS SCIENCE↗

Catalytic co-pyrolysis of LDPE and PET with HZSM-5, H-beta, and HY: experiments and kinetic modelling

In this study, the catalytic pyrolysis of low-density polyethylene (LDPE), polyethylene terephthalate (PET) and their mixture (1 : 1 wt/wt) with three zeolite catalysts (HZSM-5, H-beta, HY) was investigated using a thermogravimetric analyzer (TGA) and a Pyroprobe® micro-reactor coupled to a gas chromatograph mass spectrometer (Py-GC/MS). The TGA results demonstrated that during pyrolysis at 10 °C min –1 , on average, zeolite catalysts decreased the maximum decomposition temperature by 149 °C for LDPE while only decreasing by 8 °C for PET. The derivative thermogravimetric (DTG) curve evidenced interactions when the two polymers were catalytically co-pyrolyzed for all the three catalysts. A lumped nth order reaction scheme was able to accurately model both non-catalytic and catalytic pyrolysis and co-pyrolysis by using the least squares fitting approach for determining the kinetic parameters. The kinetic model was able to model well the interaction effects observed during catalytic co-pyrolysis of LDPE and PET with HZSM-5, H-beta, and HY (Fit% Wt% > 96%, Fit% DTG > 94%). Py-GC/MS experiments for the catalytic fast pyrolysis of LDPE revealed that HZSM-5 resulted in the highest selectivity to aromatic hydrocarbons (31.6%) and HY resulted in the highest selectivity to gasoline range C 5 –C 10 paraffins and olefins (40.9%). Catalytic fast pyrolysis of PET showed high selectivity to benzene for all the catalysts (>43%) and that HZSM-5 resulted in the highest selectivity to polyaromatic hydrocarbons (24.7%). Finally, the catalytic fast co-pyrolysis of LDPE and PET revealed interaction effects for all the three catalysts evidenced by a positive synergy% for alkylated benzenes (3–142%) and polyaromatics (105–187%) with a concomitant negative synergy% for benzene (24–36%) and C 5 –C 10 paraffins and olefins (27–53%).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interpreting T-History Data on Supercooling and Phase Change Enthalpy of a Salt-Hydrogel Complex for Building Thermal Management

Phase change materials (PCMs) are promising materials for storing and discharging latent heat in buildings to regulate the thermal environment. Measurement of salt hydrate PCM thermal performance is often challenging because of supercooling and phase segregation. Though differential scanning calorimetry (DSC) has been widely used to measure thermal properties of various phase change materials, DSC uses milligrams of sample and is unrealistic for predicting large-scale materials performance. The T-history method [1], in contrast, handles higher volumes but the analysis typically requires a lumped capacitance assumption. Here, we report and analyze T-History data on a novel salt-hydrogel complex with high viscosity, that renders low Biot number sample preparation extremely challenging. We re-examine the standard T-history method and compared against DSC data in this complex material. We report details of an experimental setup, built with necessary additions to a controlled environmental chamber. We carefully examine the validity of the lumped capacitance assumption and suggest a modified analysis using a computational approach for reliable data. Experimental parameters such as ramp rate and temperature range of the environmental chamber are considered via computational modeling to understand the effect of ramp rate on supercooling [2]. Finally, we report thermal cycling experiments on the salt-hydrogel complex. Our modified approach to measuring supercooling and enthalpy of fusion at large scales is important in better understanding the performance of phase-change materials at scale for building thermal storage. References: [1] Marin, Jose M, Belen Zalba, Luisa F Cabeza, and Harald Mehling. “Determination of Enthalpy Temperature Curves of Phase Change Materials with the Temperature-History Method: Improvement to Temperature Dependent Properties.” Measurement Science and Technology 14, no. 2 (February 1, 2003): 184–89. https://doi.org/10.1088/0957-0233/14/2/305. [2] Safari, A., R. Saidur, F.A. Sulaiman, Yan Xu, and Joe Dong. “A Review on Supercooling of Phase Change Materials in Thermal Energy Storage Systems.” Renewable and Sustainable Energy Reviews 70 (April 2017): 905–19. https://doi.org/10.1016/j.rser.2016.11.272

thermodynamics↗

Control of space stations

A study is made to develop controllers for the NASA-JSC Triangular Space Station and evaluate their performances to make recommendations for structural design and/or control alternatives. The control system design assumes the rigid body of the Space Station and developes the lumped parameter control system by using the Inverse Optimal Control Theory. In order to evaluate the performance of the control system, a Parameter Estimation algorithm is being developed which will be used in modeling an equivalent but simpler Space Station model. Finally, a scaled version of the Space Station is being built for the purpose of physical experiments to evaluate the control system performance.

Lee, K. Y.↗

Analysis of Postulated Accident Scenarios for the Transformational Challenge Reactor

The Transformational Challenge Reactor (TCR) is a helium-cooled, yttrium-hydride-moderated reactor that was designed for the U.S. Department of Energy Office of Nuclear Energy. A key objective of the TCR was to employ advanced manufacturing techniques in a nuclear system and demonstrate their potential for revolutionizing the nuclear reactor design process. One purpose of the present work is to demonstrate the safety of the TCR under postulated accidents. Based on RELAP5-3D and COMSOL analyses, the TCR remained below all current safety limits and far below the expected failure limits for the core materials. Another purpose of this work is to provide useful insights and recommendations regarding the application of RELAP5-3D to gas-cooled or other advanced reactors. A novel approach was implemented for simultaneously modeling conduction and radiation in RELAP5-3D, which was found to provide reasonable predictions of radial core, vessel, and ex-vessel heat transfer during postulated events. A multicode approach was also applied, in which high-fidelity COMSOL calculations were used to tune the radial heat transfer parameters in RELAP5-3D. The tuned RELAP5-3D model demonstrated comparable peak temperature predictions as COMSOL, despite a coarse treatment of the core in RELAP5-3D consisting of only two lumped heat structures. This high-fidelity tuning approach enabled enhanced accuracy as well as minimal complexity within the RELAP5-3D model, even for complex fuel geometric designs as in the TCR. Finally, investigations were made into the potential for flow reversal during a pressurized loss-of-forced-flow event in the TCR. The TCR is designed with downward helium flow through the core during normal operation. The RELAP5-3D model predicted that this downward flow would persist, without flow reversal, up to several days after the circulator trip. This was attributed to natural circulation hysteresis effects as have been noted in similar thermofluidic systems. Although flow stagnation and eventual reversal did not lead to unsafe TCR conditions, interesting spatial effects were observed which may have safety relevance for other reactor system designs and coolant types that are designed for downward core flow during normal operation, warranting closer investigation of the flow reversal phenomenon.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Identification of quasi-steady compressor characteristics from transient data

The principal goal was to demonstrate that nonlinear compressor map parameters, which govern an in-stall response, can be identified from test data using parameter identification techniques. The tasks included developing and then applying an identification procedure to data generated by NASA LeRC on a hybrid computer. Two levels of model detail were employed. First was a lumped compressor rig model; second was a simplified turbofan model. The main outputs are the tools and procedures generated to accomplish the identification.

Nunes, K. B.↗

Distributed parameter estimation for NASA Mini-Mast truss through displacement measurements

Most methods of system identification of large flexible structures by far are based on the lumped parameter approach. Because of the considerable computational burden due to the large number of unknown parameters, distributed parameter approach, which greatly decreases the number of unknowns, has being investigated. In this paper a distributed parameter model for the estimation of modal characteristics of NASA Mini-Mast truss has been formulated. Both Bernoulli-Euler beam and Timoshenko beam equations are used to characterize the lateral bending vibrations of the truss. The measurement of the lateral displacement at the tip of the truss is provided to the maximum likelihood estimator. Closed-form solutions of the partial differential equations and closed-form expressions of the sensitivity functions are derived so that the estimation algorithm is highly efficient. The resulting estimates from test data by using Timoshenko beam model are found to be comparable to those derived from finite element analysis.

Huang, Jen-Kuang↗