Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Aquarius RFI Detection and Mitigation Algorithm: Assessment and Examples

Aquarius is an L-band radiometer system designed to map sea surface salinity from space. This is a sensitive measurement, and protection from radio frequency interference (RFI) is important for success. An initial look at the performance of the Aquarius RFI detection and mitigation algorithm is reported together with examples of the global distribution of RFI at the L-band. To protect against RFI, Aquarius employs rapid sampling (10 ms) and a "glitch" detection algorithm that looks for outliers among the samples. Samples identified as RFI are removed, and the remainder is averaged to produce an RFI-free signal for the salinity retrieval algorithm. The RFI detection algorithm appears to work well over the ocean with modest rates for false alarms (5%) and missed detection. The global distribution of RFI coincides well with population centers and is consistent with observations reported by the Soil Moisture and Ocean Salinity mission.

remote sensing↗

Optimized Heat Pipe Backup Cooling System Tested with a Stirling Convertor

In a Stirling Radioisotope Power System (RPS), heat must be continuously removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. The Stirling convertor normally provides this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS at the cost of an early termination of the mission. An alkali-metal variable conductance heat pipe (VCHP) can be used to passively allow multiple stops and restarts of the Stirling convertor by bypassing the heat during stops. In a previous NASA Small Business Innovation Research (SBIR) Program, Advanced Cooling Technologies, Inc. (ACT) developed a series of sodium VCHPs as backup cooling systems for the Stirling RPS. In 2012, one of these VCHPs was successfully tested at NASA Glenn Research Center with a Stirling convertor as an Advanced Stirling Radioisotope Generator (ASRG) backup cooling system. The prototype; however, was not optimized and did not reflect the final heat rejection path. ACT through further funding has developed a semioptimized prototype with the finalized heat path for testing at Glenn with a Stirling convertor. The semioptimized system features a two-phase radiator and is significantly smaller and lighter than the prior prototype to reflect a higher level of flight readiness. The VCHP is designed to activate and remove heat from the GPHS during stoppage with a small temperature increase from the nominal vapor temperature. This small temperature increase from nominal is low enough to avoid risking standard ASRG operation and spoiling of the multilayer insulation (MLI). The VCHP passively allows the Stirling convertor to be turned off multiple times during a mission with potentially unlimited off durations. Having the ability to turn the Stirling off allows for the Stirling to be reset and reduces vibrations on the platform during sensitive measurements or procedures. This paper presents the design of the VCHP and its test results with a Stirling convertor at Glenn. Tests were carried for multiple on and off cycles to demonstrate repeatability. The impacts associated with the addition of the VCHP to the system are also addressed in terms of mass and additional heat losses due to the presence of the VCHP.

Heat Pipe↗

Optimized Heat Pipe Backup Cooling System Tested with a Stirling Convertor

Advanced Stirling Radioisotope Generator (ASRG) is an attractive energy system for select space missions, and with the addition of a VCHP, it becomes even more versatile. The ASRG is powered through thermal energy from decaying radioisotopes acting as General Purpose Heat Sources (GPHS). A Stirling engine converts the thermal energy to electrical energy and cools the GPHS [2]. The Stirling convertor must operate continuously to maintain acceptable temperatures of the GPHS and protect their cladding. The addition of alkali metal VCHP allows the Stirling to cycle on and off during a mission and can be used as a backup cooling system. The benefits of being able to turn the Stirling off are: allowing for a restart of the Stirling and reducing vibrations for sensitive measurements. The VCHP addition should also increase the efficiency of the Stirling by providing a uniform temperature distribution at the heat transfer interface into the heater head.

Stirling Radioisotope Generator↗

Better Performance on the Psychomotor Vigilance Task Is Associated with Longer Sleep Duration and Lower Self-Reported Sleep Need in the Real World

The psychomotor vigilance task (PVT) is sensitive measure of performance impairment arising from sleep loss and circadian misalignment. Some individuals are able to maintain stable, good performance during laboratory-imposed sleep restriction. It is unclear whether such individuals need less sleep or whether they are more resilient to the effects of sleep loss. We aimed to characterize the relationship between sleep duration and perceived sleep need with PVT performance under real-world conditions.

sleep↗

Radiation and the Immune System

Radiation has profound effects on the immune system. This makes it particularly important to study in order to protect astronauts venturing into deep space and cancer patients considering radiotherapy treatments. Beyond the Earth's magentic field lies galactic cosmic radiation, which contains heavy ion based rays. Immune alterations in response to radiation depends on factors such as the type and amount of radiation, and potentially even the genes of the individual being exposed. In order to study the effects of cosmic radiation on the immune system, we are exposing primary human immune cells to various types and amounts of radiation. To measure sensitivity to radiation, we are quantifying the DNA damage within the cells before irradiation, 4 hours after irradiation, and 24 hours after irradiation. DNA damage is visualized by fluorescently staining for known DNA repair proteins, which get recruited to the site of damage within a cell. These results will be analyzed to search for correlations between immune cell responses and the type of radiation, amount of radiation, or any genetic markers present in the human blood donors. We will also be attempting to determine which specific immune cells are most suspectible to radiation damage. These correlations and discoveries will contribute to making long duration human deep space exploration a possibility, and can even be used to design more personalized and effective radiation treatments for cancer patients.

Malkani, Sherina S.↗

The Case for Probe-Class NASA Astrophysics Missions

Astrophysics spans an enormous range of questions on scales from individual planets to the entire cosmos. To address the richness of 21st century astrophysics requires a corresponding richness of telescopes spanning all bands and all messengers. Much scientific benefit comes from having the multi-wavelength capability available at the same time. Most of these bands, or measurement sensitivities, require space-based missions. Historically, NASA has addressed this need for breadth with a small number of flagship-class missions and a larger number of Explorer missions. While the Explorer program continues to flourish, there is a large gap between Explorers and strategic missions.

Elvis, Martin↗

Atmospheric Instrument Systems and Technology in the Goddard Earth Sciences Division

Studies of the Earth’s atmosphere require a comprehensive set of observations that rely on instruments flown on spacecraft, aircraft, and balloons as well as those deployed on the surface. Within NASA’s Goddard Space Flight Center (GSFC) Earth Sciences Division-Atmospheres, laboratories and offices maintain an active program of instrument system development and observational studies that provide: 1) information leading to a basic understanding of atmospheric processes and their relationships with the Earth’s climate system, 2) prototypes for future flight instruments, 3) instruments to serve as calibration references for satellite missions, and 4) instruments for future field validation campaigns that support ongoing space missions. Our scientists participate in all aspects of instrument activity, including component and system design, calibration techniques, retrieval algorithm development, and data processing systems. The Atmospheres Program has well-equipped labs and test equipment to support the development and testing of instrument systems, such as a radiometric calibration and development facility to support the calibration of ultraviolet and visible (UV/VIS), space-borne solar backscatter instruments. This document summarizes the features and characteristics of 46 instrument systems that currently exist or are under development. The report is organized according to active, passive, or in situ remote sensing across the electromagnetic spectrum. Most of the systems are considered operational in that they have demonstrated performance in the field and are capable of being deployed on relatively short notice. Other systems are under study or of low technical readiness level (TRL). The systems described herein are designed mainly for surface or airborne platforms. However, two Cubesat systems also have been developed through collaborative efforts. The Solar Disk Sextant (SDS) is the single balloon-borne instrument. The lidar systems described herein are designed to retrieve clouds, aerosols, methane, water vapor pressure, temperature, and winds. Most of the lasers operate at some wavelength combination of 355, 532, and 1064 nm. The various systems provide high sensitivity measurements based on returns from backscatter or Raman scattering including intensity and polarization. Measurements of the frequency (Doppler) shift of light scattered from various atmospheric constitutes can also be made. Microwave sensors consist of both active (radar) and passive (radiometer) systems. These systems are important for studying processes involving water in various forms. The dielectric properties of water affect microwave brightness temperatures, which are used to retrieve atmospheric parameters such as rainfall rate and other key elements of the hydrological cycle. Atmosphere radar systems operate in the range from 9.6 GHz to 94 GHz and have measurement accuracies from -5 to 1 dBZ; radiometers operate in the 50 GHz to 874 GHz range with accuracies from 0.5 to 1 degree K; conical and cross-track scan modes are used. Our passive optical sensors, consisting of radiometers and spectrometers, collectively operate from the UV into the infrared. These systems measure energy fluxes and atmospheric parameters such as trace gases, aerosols, cloud properties, or altitude profiles of various species. Imager spatial resolution varies from 37 m to 400 m depending on altitude; spectral resolution is as small as 0.5 nm. Many of the airborne systems have been developed to fly on multiple aircraft.

Platnick, Steven E.↗

Sensor Noise in LISA Pathfinder: In-Flight Performance of the Optical Test Mass Readout

We report on the first subpicometer interferometer flown in space. It was part of ESA’s Laser Interferometer Space Antenna (LISA) Pathfinder mission and performed the fundamental measurement of the positional and angular motion of two free-falling test masses. The interferometer worked immediately, stably, and reliably from switch on until the end of the mission with exceptionally low residual noise of 32.0 (+2.4, −1.7) fm/(√Hz), significantly better than required. We present an upper limit for the sensor performance at millihertz frequencies and a model for the measured sensitivity above 200 mHz.

Gravitational Waves,↗

Sources of Formaldehyde in U.S. Oil and Gas Production Regions

We analyzed observational and model data to study the sources of formaldehyde over oil and gas production regions and to investigate how these observations may be used to constrain oil and gas VOC emissions. The analysis of aircraft and satellite data consistently found that formaldehyde over oil and gas production regions during spring and summer is mostly formed by the photooxidation of precursor VOCs. Formaldehyde columns over the Permian basin, one of the largest oil and gas producing regions in the United States, are correlated with production locations. Formaldehyde simulations by the atmospheric chemistry and transport model WRF-Chem, which included oil and gas NOx and VOC emissions from the fuel-based oil and gas inventory, were in very good agreement with TROPOMI satellite measurements. Sensitivity studies illustrated that VOCs released from oil and gas activities are important precursors to formaldehyde, but other sources of VOCs contribute as well, and that the formation of secondary formaldehyde is highly sensitive to NOx. We also investigated the ability of the chemical mechanism used in WRF-Chem to represent formaldehyde formation from oil and gas hydrocarbons by comparing against the Master Chemical Mechanism. Further, our work provides estimates of primary formaldehyde emissions from oil and gas production activities, with per basin averages ranging from 0.07 kg h -1 to 2.2 kg h -1 in 2018. A separate estimate for natural gas flaring found that flaring emissions could contribute 5% to 12% to the total primary formaldehyde emissions for the Permian basin in 2018.

SAF↗

Using Pressure Sensitive Paint to Measure Aerodynamic Forces on a Rotor Blade in Hover

This report will present details of a Pressure Sensitive Paint (PSP) system for measuring global surface pressures on rotorcraft blades in hover at the Rotor Test Cell located in the 14- by 22-Foot Subsonic Tunnel complex at the NASA Langley Research Center. This work builds upon previous entries and focused on collecting measurements from the upper and lower surface simultaneously. From these results, normal force (F (sub z)) values can be obtained. To date, this is the first time that the Pressure Sensitive Paint technique has been used for these types of measurements on rotor blades. In addition, several areas of improvement have been identified and are currently being developed for future testing.

Watkins, Anthony Neal↗

Blade Tip Pressure Measurements Using Pressure Sensitive Paint

This paper discusses the application of pressure sensitive paint using laser-based excitation for measurement of the upper surface pressure distribution on the tips of rotor blades in hover and simulated forward flight. The testing was conducted in the Rotor Test Cell and the 14- by 22-ft Subsonic Tunnel at the NASA Langley Research Center on the General Rotor Model System (GRMS) test stand. The Mach-scaled rotor contained three chordwise rows of dynamic pressure transducers for comparison with PSP measurements. The rotor had an 11 ft 1 in. diameter, 5.45 in. main chord and a swept, tapered tip. Three thrust conditions were examined in hover, C(sub T) = 0.004, 0.006 and 0.008. In forward flight, an additional thrust condition, C(sub T) = 0.010 was also examined. All four thrust conditions in forward flight were conducted at an advance ratio of 0.35.

Wong, Oliver D.↗

Precision and sensitivity of the measurement of 15N enrichment in D-alanine from bacterial cell walls using positive/negative ion mass spectrometry

Sensitive detection of cellular components from specific groups of microbes can be utilized as 'signatures' in the examination of microbial consortia from soils, sediments or biofilms. Utilizing capillary gas chromatography/mass spectrometry and stereospecific derivatizing agents, D-alanine, a component localized in the prokaryotic (bacterial) cell wall, can be detected reproducibly. Enrichments of D-[15N]alanine determined in E. coli grown with [15N]ammonia can be determined with precision at 1.0 atom%. Chemical ionization with methane gas and the detection of negative ions (M - HF)- and (M - F or M + H - HF)- formed from the heptafluorobutyryl D-2 butanol ester of D-alanine allowed as little as 8 pg (90 fmol) to be detected reproducibly. This method can be utilized to define the metabolic activity in terms of 15N incorporation at the level of 10(3)-10(4) cells, as a function of the 15N-14N ratio.

Non-NASA Center↗

Vibrational sensitivity of a measuring instrument and methods of increasing the accuracy of its determinations

The properties and peculiarities of two groups of measuring systems reacting to vibrations are discussed. Specifically, results of the action of a three dimensional, cophasal, monoharmonic vibration on the linear system of a measuring instrument was analyzed. Data are also given on the connection between vibration sensitivity and vibration resistance for instruments, methods for estimating vibration resistance, and formulas for expressing test results of vibration resistance. Experimental data are also given for decreasing errors in nonlinear systems during vibrations.

Mironov, Y. S.↗

A Method for Rapid Measurement of Contrast Sensitivity on Mobile Touch-Screens

Touch-screen displays in cell phones and tablet computers are now pervasive, making them an attractive option for vision testing outside of the laboratory or clinic. Here we de- scribe a novel method in which subjects use a finger swipe to indicate the transition from visible to invisible on a grating which is swept in both contrast and frequency. Because a single image can be swiped in about a second, it is practical to use a series of images to zoom in on particular ranges of contrast or frequency, both to increase the accuracy of the measurements and to obtain an estimate of the reliability of the subject. Sensitivities to chromatic and spatio-temporal modulations are easily measured using the same method. A proto- type has been developed for Apple Computer's iPad/iPod/iPhone family of devices, implemented using an open-source scripting environment known as QuIP (QUick Image Processing, http://hsi.arc.nasa.gov/groups/scanpath/research.php). Preliminary data show good agreement with estimates obtained from traditional psychophysical methods as well as newer rapid estimation techniques. Issues relating to device calibration are also discussed.

contrast sensitivity↗

Method for Measuring Collimator-Pointing Sensitivity to Temperature Changes

For a variety of applications, it is important to measure the sensitivity of the pointing of a beam emerging from a collimator, as a function of temperature changes. A straightforward method for carrying out this measurement is based on using interferometry for monitoring the changes in beam pointing, which presents its own problems. The added temperature dependence and complexity issues relating to using an interferometer are addressed by not using an interferometer in the first place. Instead, the collimator is made part of an arrangement that uses a minimum number of low-cost, off-the-shelf materials and by using a quad diode to measure changes in beam pointing. In order to minimize the influence of the test arrangement on the outcome of the measurement, several steps are taken. The collimator assembly is placed on top of a vertical, 1-m-long, fused silica tube. The quad diode is bonded to a fused silica bar, which, in turn, is bonded to the lower end of the fused silica tube. The lower end of the tube rests on a self-aligning support piece, while the upper end of the tube is kept against two rounded setscrew tips, using a soft rubber string. This ensures that very little stress is applied to the tube as the support structure changes dimensions due to thermal expansion. Light is delivered to the collimator through a bare fiber in order to minimize variable bending torque caused by a randomly relaxing, rigid fiber jacket. In order to separate the effect of temperature on the collimator assembly from the effect temperature has on the rest of the setup, multiple measurements are taken with the collimator assembly rotated from measurement to measurement. Laboratory testing, with 1-m spacing between the collimator and the quad diode, has shown that the sensitivity of the arrangement is better than 100 nm rms, over time spans of at least one hour, if the beam path is protected from atmospheric turbulence by a tube. The equivalent sensitivity to detecting changes in pointing angle is 100 nanoradians.

Abramovici, Alex↗