At least 271 records · Page 15

The radiation budget of stratocumulus clouds measured by tethered balloon instrumentation: Variability of flux measurements

Measurements of longwave and shortwave radiation were made using an instrument package on the NASA tethered balloon during the FIRE Marine Stratocumulus experiment. Radiation data from two pairs of pyranometers were used to obtain vertical profiles of the near-infrared and total solar fluxes through the boundary layer, while a pair of pyrgeometers supplied measurements of the longwave fluxes in the cloud layer. The radiation observations were analyzed to determine heating rates and to measure the radiative energy budget inside the stratocumulus clouds during several tethered balloon flights. The radiation fields in the cloud layer were also simulated by a two-stream radiative transfer model, which used cloud optical properties derived from microphysical measurements and Mie scattering theory.

Duda, David P.↗

Neutron temporal diagnostic for high-yield deuterium–tritium cryogenic implosions on OMEGA

A next-generation neutron temporal diagnostic (NTD) capable of recording high-quality data for the highest anticipated yield cryogenic deuterium–tritium (DT) implosion experiments was recently installed at the Omega Laser Facility. A high-quality measurement of the neutron production width is required to determine the hot-spot pressure achieved in inertial confinement fusion experiments—a key metric in assessing the quality of these implosions. The design of this NTD is based on a fast-rise-time plastic scintillator, which converts the neutron kinetic energy to 350- to 450-nm-wavelength light. The light from the scintillator inside the nose-cone assembly is relayed ∼16 m to a streak camera in a well-shielded location. An ∼200× reduction in neutron background was observed during the first high-yield DT cryogenic implosions compared to the current NTD installation on OMEGA. An impulse response of ∼40 ± 10 ps was measured in a dedicated experiment using hard x-rays from a planar target irradiated with a 10-ps short pulse from the OMEGA EP laser. The measured instrument response includes contributions from the scintillator rise time, optical relay, and streak camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Doppler instrumentation for measuring blood velocity and flow

Doppler ultrasonic blood flowmeters are reviewed in detail. The importance of measurement accuracy for transcutaneous flowmeters and their clinical application is stressed. Doppler imaging was combined with conventional pulse echo imaging, and diagnostic information was extracted from flow signals. The range and extent of applications of Doppler instruments was also presented.

Gill, R. W.↗

GeoXO Atmospheric Composition Instrument (AC) Measurements Conditions Assessment

NOAA’s next generation Geostationary Extended Observations (GeoXO) satellite system will advance Earth observations from geostationary orbit. GeoXO will supply vital information supporting the U.S. weather, ocean, and climate operations. The recommended three-satellite constellation includes spacecraft at GOES-Central position, that will carry an Atmospheric Composition Instrument (ACX) among its payloads; the requirement on the ACX is to scan its region of interest in one hour. An assessment of ACX observational conditions is presented, based on view geometry and solar angle range over the year. The availability for observations of each pixel is estimated per day of the year, as function of the geometric air mass factor (AMF), which can be related to signal to noise ratio using a model of the ACX instrument performance, and ultimately to expected column error for specific atmospheric species. In addition, cloud climatology – based on statistics derived from GOES-16 ABI cloud product data – is considered to determine typical fractions of cloud-free ACX observations and typical cloud optical depths, for each pixel as function of time of day and season. The results of such assessments can be used to prepare for GeoXO ACX data and further the understanding and development of the future instrument operations.

Boryana Efremova↗

Instrument for Measuring Engine Clearance Volumes

With the advent of the V type engine, a new method to measure the clearance volume in cylinders was needed. It was suggested that this measurement could be made by a process which consisted essentially of simultaneously changing both a known and unknown volume of gas by a known amount and then calculating the magnitude of the unknown from the resulting difference in pressure between the two. An instrument based on this design is described.

Sparrow, S W↗

Size resolved particle volatility for 30, 60, and 90 nm particles collected at the EPCAPE Mount Soledad site from 04/23/2023 to 06/15/2023

VTDMA GF-PDF: Growth factor probability density functions from the Gysel inversion are located here, where probability is out of 200. The instrument measured three different diameters 30 nm, 60nm and 90nm each diameter was selected for an hour. During that hour three different temperatures where scanned (40°C, 80°C, 160°C) in between each temperature a bypass scan was taken at room temperature. Each scan took 10-minutes and scanned growth factors from 0.2-1.2. Calibrations of the instrument with NaCl were performed on 4/26/2023 from 11:20 to 14:20, on 5/16/2023 from 11:40 to 16:00, and on 5/30/2023 from 10:20 to 14:20. Calibrations with (NH4)2SO4 were performed on 5/8/2023 from 11:45 to 14:40, on 5/23/2023 from 11:20 to 3:00, and on 6/14/2023 from 13:00 to 16:00. Time is recorded in seconds since 1/1/1904. GF_Vol_avg: Growth factor volume average calculated by the Gysel inversion. The instrument measured three different diameters 30 nm, 60nm and 90nm each diameter was selected for an hour. During that hour three different temperatures where scanned (40°C, 80°C, 160°C) in between each temperature a bypass scan was taken at room temperature. Each scan took 10-minutes and scanned growth factors from 0.2-1.2. Calibrations of the instrument with NaCl were performed on 4/26/2023 from 11:20 to 14:20, on 5/16/2023 from 11:40 to 16:00, and on 5/30/2023 from 10:20 to 14:20. Calibrations with (NH4)2SO4 were performed on 5/8/2023 from 11:45 to 14:40, on 5/23/2023 from 11:20 to 3:00, and on 6/14/2023 from 13:00 to 16:00. Time is recorded in seconds since 1/1/1904.

30nm growth factor volume average at 160C (GF_vol_↗

OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. III. MEASURES BELOW THE DIFFRACTION LIMIT OF THE WIYN TELESCOPE

In this paper, we study the ability of CCD- and electron-multiplying-CCD-based speckle imaging to obtain reliable astrometry and photometry of binary stars below the diffraction limit of the WIYN 3.5 m Telescope. We present a total of 120 measures of binary stars, 75 of which are below the diffraction limit. The measures are divided into two groups that have different measurement accuracy and precision. The first group is composed of standard speckle observations, that is, a sequence of speckle images taken in a single filter, while the second group consists of paired observations where the two observations are taken on the same observing run and in different filters. The more recent paired observations were taken simultaneously with the Differential Speckle Survey Instrument, which is a two-channel speckle imaging system. In comparing our results to the ephemeris positions of binaries with known orbits, we find that paired observations provide the opportunity to identify cases of systematic error in separation below the diffraction limit and after removing these from consideration, we obtain a linear measurement uncertainty of 3-4 mas. However, if observations are unpaired or if two observations taken in the same filter are paired, it becomes harder to identify cases of systematic error, presumably because the largest source of this error is residual atmospheric dispersion, which is color dependent. When observations are unpaired, we find that it is unwise to report separations below approximately 20 mas, as these are most susceptible to this effect. Using the final results obtained, we are able to update two older orbits in the literature and present preliminary orbits for three systems that were discovered by Hipparcos.

79 ASTRONOMY AND ASTROPHYSICS↗

Compact Instrument for Measuring Profile of a Light Beam

The beamviewer is an optical device designed to be attached to a charge-coupled-device (CCD) image detector for measuring the spatial distribution of intensity of a beam of light (the beam profile ) at a designated plane intersecting the beam. The beamviewer-and-CCD combination is particularly well suited for measuring the radiant- power profile (for a steady beam) or the radiant-energy profile (for a pulsed beam) impinging on the input face or emerging from the output face of a bundle of optical fibers. The beamviewer and-CCD combination could also be used as a general laboratory instrument for profiling light beams, including beams emerging through small holes and laser beams in free space.

Papanyan, Valeri↗

Observations of Binary Stars with the Differential Speckle Survey Instrument. VIII. Measures of Metal-poor and Triple Stars from 2015 to 2018

We present 248 speckle observations of 43 binary and 19 trinary star systems chosen to make progress in two main areas of investigation: the fundamental properties of metal-poor stars and star formation mechanisms. The observations were taken at the Gemini North and South telescopes during the period 2015 July to 2018 April, mainly with the Differential Speckle Survey Instrument but also with a few early results from the new ’Alopeke speckle camera at Gemini North. We find that the astrometry and photometry of these observations as a whole are consistent with previous work at Gemini. We present five new visual orbits for systems important in understanding metal-poor stars, three of which have orbital periods of less than 4 yr, and we indicate the degree to which these and future observations can impact our knowledge of stellar properties and star formation. In particular, we find a decrease in mass at fixed spectral type for metal-poor stars versus their solar-metallicity analogs that is consistent with predictions that are made from current stellar models.

79 ASTRONOMY AND ASTROPHYSICS↗

High Speed PC Based Data Acquisition and Instrumentation for Measurement of Simulated Low Earth Orbit Thermally Induced Disturbances

The Hubble Space Telescope (HST) Disturbance Verification Test (DVT) was conducted to characterize responses of the Observatory's new set of rigid solar array's (SA3) to thermally induced 'creak' or stiction releases. The data acquired in the DVT were used in verification of the HST Pointing Control System on-orbit performance, post-Servicing Mission 3B (SM3B). The test simulated the on-orbit environment on a deployed SA3 flight wing. Instrumentation for this test required pretest simulations in order to select the correct sensitivities. Vacuum compatible, highly accurate accelerometers and force gages were used for this test. The complexity of the test, as well as a short planning schedule, required a data acquisition system that was easy to configure, highly flexible, and extremely robust. A PC Windows oriented data acquisition system meets these requirements, allowing the test engineers to minimize the time required to plan and perform complex environmental test. The SA3 DVT provided a direct practical and complex demonstration of the versatility that PC based data acquisition systems provide. Two PC based data acquisition systems were assembled to acquire, process, distribute, and provide real time processing for several types of transducers used in the SA3 DVT. A high sample rate digital tape recorder was used to archive the sensor signals. The two systems provided multi-channel hardware and software architecture and were selected based on the test requirements. How these systems acquire and processes multiple data rates from different transducer types is discussed, along with the system hardware and software architecture.

Sills, Joel W., Jr.↗

An Instrument to Measure Elemental Energy Spectra of Cosmic Ray Nuclei Up to 10(exp 16) eV

A longstanding goal of cosmic ray research is to measure the elemental energy spectra of cosmic rays up to and through the "knee" (approx. equal to 3 x 10 (exp 15) eV. It is not currently feasible to achieve this goal with an ionization calorimeter because the mass required to be deployed in Earth orbit is very large (at least 50 tonnes). An alternative method will be presented. This is based on measuring the primary particle energy by determining the angular distribution of secondaries produced in a target layer using silicon microstrip detector technology. The proposed technique can be used over a wide range of energies (10 (exp 11)- 10 (exp 16) eV) and gives an energy resolution of 60% or better. Based on this technique, a design for a new lightweight instrument with a large aperture (KLEM) will be described.

Adams, J.↗

Advanced Remotely Operated Vehicle for Education and Research

Disclosed are watercrafts with rotatable air propulsion steering units and retractable measurement instruments. The watercraft can include a substantially flat bottom, a top deck, a rotatable air propulsion steering unit configured to propel the watercraft and to rotate in order to steer the watercraft when the watercraft is submerged in a liquid body without requiring a submerged rudder steering system under the substantially flat bottom. The watercraft can also include a retractable measurement deck configured to alternatively raise measurement instruments above the liquid body and lower into the liquid body.

Miles, Ted K.↗

Problems inherent in using aircraft for radio oceanography studies

Some of the disadvantages relating to altitude stability and proximity to the ocean are described for radio oceanography studies using aircraft. The random oscillatory motion introduced by the autopilot in maintaining aircraft altitude requires a more sophisticated range tracker for a radar altimeter than would be required in a satellite application. One-dimensional simulations of the sea surface (long-crested waves) are performed using both the JONSWAP spectrum and the Pierson-Moskowitz spectrum. The results of the simulation indicate that care must be taken in trying to experimentally verify instrument measurement accuracy. Because of the relatively few wavelengths examined from an aircraft due to proximity to the ocean and low velocity compared to a satellite, the random variation in the sea surface parameters being measured can far exceed an instrument's ability to measure them.

Walsh, E. J.↗

A Thermal Analysis of a Hot-Wire Probe for Icing Applications

This paper presents a steady-state thermal model of a hot-wire instrument applicable to atmospheric measurement of water content in clouds. In this application, the power required to maintain the wire at a given temperature is used to deduce the water content of the cloud. The model considers electrical resistive heating, axial conduction, convection to the flow, radiation to the surroundings, as well as energy loss due to the heating, melting, and evaporation of impinging liquid and or ice. All of these parameters can be varied axially along the wire. The model further introduces a parameter called the evaporation potential which locally gauges the maximum fraction of incoming water that evaporates. The primary outputs of the model are the steady-state power required to maintain a spatially-average constant temperature as well as the variation of that temperature and other parameters along the wire. The model is used to understand the sensitivity of the hot-wire performance to various flow and boundary conditions including a detailed comparison of dry air and wet (i.e. cloud-on) conditions. The steady-state power values are compared to experimental results from a Science Engineering Associates (SEA) Multi-Element probe, a commonly used water-content measurement instrument. The model results show good agreement with experiment for both dry and cloud-on conditions with liquid water content. For ice, the experimental measurements under read the actual water content due to incomplete evaporation and splashing. Model results, which account for incomplete evaporation, are still higher than experimental results where the discrepancy is attributed to splashing mass-loss which is not accounted in the model.

Thermal Analysis↗

Spinoff 2009

Topics covered include: Image-Capture Devices Extend Medicine's Reach; Medical Devices Assess, Treat Balance Disorders; NASA Bioreactors Advance Disease Treatments; Robotics Algorithms Provide Nutritional Guidelines; "Anti-Gravity" Treadmills Speed Rehabilitation; Crew Management Processes Revitalize Patient Care; Hubble Systems Optimize Hospital Schedules; Web-based Programs Assess Cognitive Fitness; Electrolyte Concentrates Treat Dehydration; Tools Lighten Designs, Maintain Structural Integrity; Insulating Foams Save Money, Increase Safety; Polyimide Resins Resist Extreme Temperatures; Sensors Locate Radio Interference; Surface Operations Systems Improve Airport Efficiency; Nontoxic Resins Advance Aerospace Manufacturing; Sensors Provide Early Warning of Biological Threats; Robot Saves Soldier's Lives Overseas (MarcBot); Apollo-Era Life Raft Saves Hundreds of Sailors; Circuits Enhance Scientific Instruments and Safety Devices; Tough Textiles Protect Payloads and Public Safety Officers; Forecasting Tools Point to Fishing Hotspots; Air Purifiers Eliminate Pathogens, Preserve Food; Fabrics Protect Sensitive Skin from UV Rays; Phase Change Fabrics Control Temperature; Tiny Devices Project Sharp, Colorful Images; Star-Mapping Tools Enable Tracking of Endangered Animals; Nanofiber Filters Eliminate Contaminants; Modeling Innovations Advance Wind Energy Industry; Thermal Insulation Strips Conserve Energy; Satellite Respondent Buoys Identify Ocean Debris; Mobile Instruments Measure Atmospheric Pollutants; Cloud Imagers Offer New Details on Earth's Health; Antennas Lower Cost of Satellite Access; Feature Detection Systems Enhance Satellite Imagery; Chlorophyll Meters Aid Plant Nutrient Management; Telemetry Boards Interpret Rocket, Airplane Engine Data; Programs Automate Complex Operations Monitoring; Software Tools Streamline Project Management; Modeling Languages Refine Vehicle Design; Radio Relays Improve Wireless Products; Advanced Sensors Boost Optical Communication, Imaging; Tensile Fabrics Enhance Architecture Around the World; Robust Light Filters Support Powerful Imaging Devices; Thermoelectric Devices Cool, Power Electronics; Innovative Tools Advance Revolutionary Weld Technique; Methods Reduce Cost, Enhance Quality of Nanotubes; Gauging Systems Monitor Cryogenic Liquids; Voltage Sensors Monitor Harmful Static; and Compact Instruments Measure Heat Potential.

Source record↗

ARM Aerosol Measurement Science Group Strategic Planning Workshop 2017

The Aerosol Measurement Science Group (AMSG) was tasked with evaluating the status of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s existing aerosol instrumentation, measurement strategies, and data products in the context of ARM and Atmospheric System Research (ASR) science directions and the current and future needs of ARM data users. A workshop comprising the AMSG members and external experts in aerosol measurements was convened in February 2017 to delineate specific measurements and efforts in data product development that would align the ARM aerosol program investments well with the needs of the scientific community. Topics of discussion in the workshop included priority measurements and instrumentation to be deployed at the range of ARM sites, physical system configurations that impact the character of observables and quality of observations, calibration strategies, overarching deployment strategies for aerosol observing systems (AOS), and communication about and accessibility of data. This report provides an account of workshop discussions and prioritized recommendations for ARM supported activities that will bring measurements to quality and science-ready data products relevant to the ASR and larger science community.

47 OTHER INSTRUMENTATION↗

Simulations of Tropospheric NO2 by the Global Modeling Initiative (GMI) Model Utilizing Assimilated and Forecast Meteorological Fields: Comparison to Ozone Monitoring Instrument (OMI) Measurements

We present simulations of the tropospheric composition for the years 2004 and 2005, carried out by the GMI Combined Stratosphere-Troposphere (Combo) model, at a resolution of 2degx2.5deg. The model includes a new parameterization of lightning sources of NO(x) which is coupled to the cloud mass fluxes in the adopted meteorological fields. These simulations use two different sets of input meteorological fields: a)late-look assimilated fields from the Global Modeling and Assimilation Office (GMAO), GEOS-4 system and b) 12-hour forecast fields initialized with the assimilated data. Comparison of the forecast to the assimilated fields indicates that the forecast fields exhibit less vigorous convection, and yield tropical precipitation fields in better agreement with observations. Since these simulations include a complete representation of the stratosphere, they provide realistic stratosphere-tropospheric fluxes of O3 and NO(y). Furthermore, the stratospheric contribution to total columns of different troposheric species can be subtracted in a consistent fashion, and the lightning production of NO(y) will depend on the adopted meteorological field. We concentrate here on the simulated tropospheric columns of NO2, and compare them to observations by the OM1 instrument for the years 2004 and 2005. The comparison is used to address these questions: a) is there a significant difference in the agreement/disagreement between simulations for these two different meteorological fields, and if so, what causes these differences?; b) how do the simulations compare to OMI observations, and does this comparison indicate an improvement in simulations with the forecast fields? c) what are the implications of these simulations for our understanding of the NO2 emissions over continental polluted regions?

Rodriquez, J. M.↗

System Measures Pressures Aboard A Compressor Rotor

Rotating pressure-measuring instrumentation includes on-board calibration standard. Computer-controlled, multichannel instrumentation system acquires pressure measurements from sensors mounted in 1.52-m-diameter rotor of compressor. Includes 5 miniature, electronically scanned pressure (ESP) modules, each containing 48 piezoresistive pressure sensors, pneumatic calibration valve, and electronic circuits for addressing and amplifying output of each sensor. Modules mounted on centerline of rotor, on instrumentation tower located inside nose cone of rotor. Subsystem designed to convert analog signal to distinct frequency without significantly affecting accuracy.

Freedman, Robert J.↗