Search NASA⌕ Search

SEARCH · Search NASA

Results for “mechanical devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Annual Conference on Nuclear and Space Radiation Effects, Gatlinburg, TN, July 18-21, 1983, Proceedings

Topics discussed include radiation effects in devices; the basic mechanisms of radiation effects in structures and materials; radiation effects in integrated circuits; spacecraft charging and space radiation effects; hardness assurance for devices and systems; and radiation transport, energy deposition and charge collection. Papers are presented on the mechanisms of small instabilities in irradiated MOS transistors, on the radiation effects on oxynitride gate dielectrics, on the discharge characteristics of a simulated solar cell array, and on latchup in CMOS devices from heavy ions. Attention is also given to proton upsets in orbit, to the modeling of single-event upset in bipolar integrated circuits, to high-resolution studies of the electrical breakdown of soil, and to a finite-difference solution of Maxwell's equations in generalized nonorthogonal coordinates.

Source record↗

Development of NASA-DeBakey Ventricular Assist Device Using Numerical Aerospace Simulation Technology

Over three million Americans and 20 million people worldwide suffer from some form of heart failure. Mechanical heart assist devices are being used as a temporary support to sick ventricle and valves as a bridge-to-transplant or bridge-to-recovery. This viewgraph presentation gives an overview of the development of NASA-DeBakey Ventricular Assist Device (VAD) using numerical aerospace simulation technology.

Kwak, Dochan↗

Method of forming a sharp edge on an optical device

A sharp edge is formed on an optical device by placing the optical device in a holding mechanism; grinding one surface so that it and a surface of the holding mechanism are co-planar; and polishing both the surface of the optical device and the surface of the holding mechanism with felt until an edge on the surface of the optical device adjacent to the surface of the holding mechanism obtains a desired sharpness.

Fleetwood, C. M.↗

Solid medium thermal engine

A device is described which uses a single phase metallic working substance to convert thermal energy directly into mechanical energy. The device consists of a cylindrical metal tube which is free to rotate about its axis while being subjected to continuous bending moment stresses along the longitudinal axis of rotation. The stressing causes portions of the tube to be under compression while other parts are under tension which in turn causes the tube to rotate and provide mechanical energy.

Jedlicka, J. R.↗

Design and testing of an electromagnetic coupling

Hostile environments such as the hard vacuum of space, and exposure to water or caustic fluids have fostered the development of devices which allow mechanical rotary feed throughs with positive sealing without the use of conventional dynamic seals. One such device is an electromagnetic coupling which transfers motion across a hermetic seal by means of a rotating magnetic field. Static pull-out torque and dynamic heat build-up and pull-out torque tests of a synchronous reluctance homopolar coupling are reported herein. Coupling efficiencies are estimated for a range of speeds and torques.

Anderson, William J.↗

Reliability study of opto-coupled semiconductor devices and Light Emitting Diodes (LED)

Opto-coupler and light emitting diode (LED) failure mechanisms and associated activation energies were determind from the results of environmental and accelerated lift tests of over 2,400 devices. The evaluation program included LED phototransistor opto-couplers from three sources, LED photoamplifier opto-couplers from a single source, and discrete infrared emitting LEDs from two sources. Environmental tests to evaluate device mechanical integrity included power cycling (10,000 cycles), temperature cycling (500 cycles) and a sequence of monitored shock, monitored vibration and constant acceleration. Multiple temperature operating life tests were conducted at ambient temperatures between 25 C and 200 C. Opto-couplers were operated in both the 'on' and 'off' states during life testing.

Maurer, R. C.↗

Slide release mechanism

A releasable support device is described which is comprised of a hollow body with a sleeve extending transversely there-through for receiving the end of a support shank. A slider-latch, optionally lubricated, extends through side recesses in the sleeve to straddle the shank, respectively, in latched and released positions. The slider-latch is slid from its latched to its unlatched position by a pressure squib whereupon a spring or other pressure means pushes the shank out of the sleeve. At the same time, a follower element is lodged in and closed the hole in the body wall from which the shank was discharged. The mechanism was designed for the shuttle orbiter/external tank connection device.

Bunker, J. W.↗

Toggle release

A pyrotechnic actuated structural release device 10 which is mechanically two fault tolerant for release. The device 10 comprises a fastener plate 11 and fastener body 12, each attachable to a different one of a pair of structures to be joined. The fastener plate 11 and body 12 are fastenable by a toggle 13 supported at one end on the fastener plate and mounted for universal pivotal movement thereon. At its other end which is received in a central opening in the fastener body 12 and adapted for limited pivotal movement therein the toggle 13 is restrained by three retractable latching pins 61 symmetrically disposed in equiangular spacing about the axis of the toggle 13 and positionable in latching engagement with an end fitting on the toggle. Each pin 61 is individually retractable by combustion of a pyrotechnic charge 77, the expanding gases of which are applied to a pressure receiving face 67 on the latch pin 61 to effect its retraction from the toggle. While retraction of all three pins 62 releases the toggle, the fastener is mechanically two fault tolerant since the failure of any single one or pair of the latch pins to retract results in an asymmetrical loading on the toggle and its pivotal movement to effect a release. An annular bolt 18 is mounted on the fastener plate 11 as a support for the socket mounting 30, 37 of the toggle whereby its selective axial movement provides a means for preloading the toggle.

Graves, Thomas J.↗

A dual output pressure, high reliability, long storage life gas delivery vessel assembly

A Gas Vessel Assembly has been developed that delivers purified, very low moisture content gas at two different output pressures. High pressure gas is delivered at up to 6,700 psi, and low pressure gas regulated to 130 psi is also delivered via a second outlet over a wide range of flow rates. The device is extremely lightweight (less than 1 lb) and compact, affords maximum mechanical integrity, high reliability (0.9999 at 95 percent confidence level), and offers extremely long storage life. Specialized design and fabrication techniques are employed that guarantee gas purity and negligible leakage for more than 20 years, in widely varying conditions of storage temperature, humidity, altitude, and vibration environments. The technology offers unique advantages in fast, high pressure discharge applications. For example, when combined with a cryostat, cryogenic temperatures can be achieved such as those used in missile seeker technology. The technology has many additional applications such as: emergency power sources for safety devices such as those needed in nuclear power plants, refineries, collision cushioning devices, superconductor cooling devices, emergency egress systems, miniature mechanical devices that employ gas bearings, and other areas where long storage, extremely high reliability and/or high energy density sources are required.

Maya, Isaac↗

The Nature of Comet Materials and Attachment to Them

Because cometary surfaces are likely to be far colder and of a different composition and surface topography than other planetary surfaces with which we have experience, there are some new considerations that must be examined in regards to placing and attaching instrumented packages or sample return devices in or on their surfaces. The qualitative analysis of the problem of embedding hardware in a comet icy core is limited to only one of several means for the purposes of this discussion. This means can be characterized as a kinetic impact piercing device. Such kinetic impact piercing device may be used to attach the feet of an instrumented package on the surface or it may be the means for implanting the package in the icy core below the mantle. The functional requirement is to implant a device in the icy core and by mechanical means, prevent the device from being ejected back into space.

Stephens, James↗

The phototron: A light to RF energy conversion device

The phototron, a photoelectric device that converts light to radio frequency energy, is described. It is a vacuum tube, free electron, device that is mechanically similar to a reflex klystron with the hot filament cathode replaced by a large area photocathode. The device can operate either with an external voltage source used to accelerate the photoelectrons or with zero bias voltage; in which case the photokinetic energy of the electrons sustains the R.F. oscillations in the tuned R.F. circuit. One basic design of the phototron was tested. Frequencies as high as about 1 GHz and an overall efficiency of about 1% in the biased mode were obtained. In the unbiased mode, the frequencies of operation and efficiences are considerably lower. Success with test model suggests that considerable improvements are possible through design refinements. One such design refinement is the reduction of the length of the electron flight path.

Freeman, J. W.↗

Tungsten solution kinetics and amorphization of nickel in mechanically alloyed Ni-W alloys

The kinetics of solution of W, and the subsequent amorphization of Ni, in mechanically alloyed Ni-W alloys has been investigated. As W is a highly abrasive material in the energy intensive devices used for mechanical alloying, we studied the above reactions in different mills. One used hardened steel balls as the grinding media, and the other Al2O3. Abrasion is common to both mills, but Fe wear debris from the hardened steel enters into solution in the Ni rich phases whereas Al2O3 debris is present as small dispersoids. The kinetics of W solution and those of subsequent amorphization do not appear strongly affected by the Fe in solution or the Al2O3 dispersoid. Tungsten dissolves in crystalline Ni in amounts in excess of the equilibrium solubility during alloying. Amorphization of the Ni phase occurs if the W content in this phase exceeds ca. 28 at. pct.

Aning, A. O.↗

Space shuttle separation mechanisms

The development of space shuttle separation devices is reviewed to illustrate the mechanisms involved in separating the Orbiter from the Boeing 747 carrier aircraft and from the externally mounted propellant tank. Other aspects of the separation device development discussed include design evolution, operational experience during the orbiter approach and landing tests, and the work required to produce an operational system.

Rogers, W. F.↗

Space Shuttle separation mechanisms

The development of space shuttle separation devices is reviewed to illustrate the mechanisms involved in separating the orbiter from the Boeing 747 carrier aircraft and from the externally mounted propellant tank. Other aspects of the separation device development discussed include design evolution, operational experience during the orbiter approach and landing tests, and the work to be accomplished before an operational system becomes a reality.

Rogers, W. F.↗

Longitudinal growth of skeletal myotubes in vitro in a new horizontal mechanical cell stimulator

A tissue-culture model system for growing skeletal-muscle cells under more dynamic conditions than found in normal tissue-culture environments is described. A computerized device presented allows mechanical stimulation of the cell's substratum by 300 to 400 pct in length in the horizontal plane. Cell growth rates and skeletal-muscle organogenesis are stimulated in this in vitro system. It is noted that longitudinal myotube growth observed is accompanied by increased rates of cell proliferation and myoblast fusion. Prestretching the collagen-coated substratum before cell plating is shown to lead to increased cell proliferation, myotube orientation, and longitudinal myotube growth. The effects of substratum stretching on myogenesis in the model system are also assessed and attributed to alterations in the cell's extracellular matrix.

Vandenburgh, Herman H.↗

Total Dose Effects in Conventional Bipolar Transistors

This paper examines various factors in bipolar device construction and design, and discusses their impact on radiation hardness. The intent of the paper is to improve understanding of the underlying mechanisms for practical devices without special test structures, and to provide (1) guidance in ways to select transistor designs that are more resistant to radiation damage, and (2) methods to estimate the maximum amount of damage that might be expected from a basic transistor design. The latter factor is extremely important in assessing the risk that future lots of devices will be substantially below design limits, which are usually based on test data for older devices.

Bipolar Devices Cassini Ionizing radiation effects↗

Electromagnetic Pain Relief/Blocking: Feasibility Assessment

Context/Background: Astronauts use pharmaceuticals during spaceflight to manage acute and chronic pain, but use of analgesics will have drawbacks for exploration-class missions because the shelf life of these medications is limited, resupply will be curtailed, astronauts may develop tolerance and/or addiction to these medications, and side effects can include impairment of cognitive abilities. Electromagnetic devices have been developed that treat pain terrestrially by affecting neuromodulation–dubbed “electroceuticals”, these devices have varied mechanisms of action that either stimulate or suppress neural activity in the central nervous system or peripheral nerves. Objective/Purpose: The available literature was reviewed and FDA-approved pain treatments (both pharmacological and non-pharmacological), as well as those currently under development, were assessed for their suitability for use in exploration class spaceflight missions. Data Sources: Due to the COVID-19 pandemic and the resulting closure of libraries, data sources were restricted to those available digitally. Online database searches included PubMed, U.S. Patent and Trademark Office, federal grant award databases (National Aeronautics and Space Administration (NASA), Department of Defense (DoD), National Institutes of Health (NIH)), and general internet searches. More than 1,600 records were reviewed in this effort. Study Selection/Eligibility Criteria: Targeted searches included different aspects of pain management. Priority was given to review studies, to cover as much of the available literature as possible in this limited effort. Study Appraisal and Synthesis Methods/Data Extraction and Data Synthesis: The titles of the studies and the awards that were obtained by searching online databases were reviewed and further information was sought for the relevant titles. Abstracts or award summaries were generally available online; for journal abstracts, full text articles were either available online or were requested via interlibrary loan. Results: An overwhelming majority of the literature focuses on the treatment of chronic rather than acute pain because it is assumed that acute pain only rarely fails to resolve and instead transitions into chronic pain when the central nervous system becomes hypersensitized. The available electromagnetic devices marketed for pain treatment have varying levels of invasiveness, use different mechanisms of action, and have demonstrated varying efficacy when evaluated scientifically. A truly noninvasive, highly efficient device is desired for use during spaceflight. One portable, self-contained, FDA-approved device was identified that, from preliminarily assessment, best met these criteria; the device noninvasively applies pulsed shortwave therapy (PSWT) to modify pain signals from peripheral nerves, however, the device has limited battery life and the effects are relatively non-selective in type of neural signal modified. Limitations: This current effort, although extensive, did not identify a comprehensive list of all alternatives for pain treatment. Once the pandemic limitations are lifted, a longer, more thorough effort may find additional options. Conclusions/Implications: The ideal electromagnetic pain treatment device for use on exploration-class spaceflight missions does not yet exist, but it may be available soon. It is not feasible for NASA to develop medical devices due to the schedule constraints for pending exploration-class missions, but adapting a promising device that is already FDA-approved might be an option. Monitoring research that is ongoing at other federal agencies is recommended, and further review of the candidate PSWT device identified in this current effort may be warranted.

Carol Mullenax↗

Electromagnetic Pain Relief/Blocking: Feasibility Assessment

CONTEXT/BACKGROUND Astronauts use pharmaceuticals during spaceflight to manage acute and chronic pain, but use of analgesics will have drawbacks for exploration-class missions because the shelf life of these medications is limited, resupply will be curtailed, astronauts may develop tolerance and/or addiction to these medications, and side effects can include impairment of cognitive abilities. Electromagnetic devices have been developed that treat pain terrestrially by affecting neuromodulation–dubbed “electroceuticals”, these devices have varied mechanisms of action that either stimulate or suppress neural activity in the central nervous system or peripheral nerves. OBJECTIVE/PURPOSE The available literature was reviewed and FDA-approved pain treatments (both pharmacological and non-pharmacological), as well as those currently under development, were assessed for their suitability for use in exploration class spaceflight missions. DATA SOURCES Due to the COVID-19 pandemic and the resulting closure of libraries, data sources were restricted to those available digitally. Online database searches included PubMed, U.S. Patent and Trademark Office, federal grant award databases (National Aeronautics and Space Administration (NASA), Department of Defense (DoD), National Institutes of Health (NIH)), and general internet searches. More than 1,600 records were reviewed in this effort. STUDY SELECTION/ELIGIBILITY CRITERIA Targeted searches included different aspects of pain management. Priority was given to review studies, to cover as much of the available literature as possible in this limited effort. STUDY APPRAISAL AND SYNTHESIS METHODS/DATA EXTRACTION AND DATA SYNTHESIS The titles of the studies and the awards that were obtained by searching online databases were reviewed and further information was sought for the relevant titles. Abstracts or award summaries were generally available online; for journal abstracts, full text articles were either available online or were requested via interlibrary loan. RESULTS An overwhelming majority of the literature focuses on the treatment of chronic rather than acute pain because it is assumed that acute pain only rarely fails to resolve and instead transitions into chronic pain when the central nervous system becomes hypersensitized. The available electromagnetic devices marketed for pain treatment have varying levels of invasiveness, use different mechanisms of action, and have demonstrated varying efficacy when evaluated scientifically. A truly noninvasive, highly efficient device is desired for use during spaceflight. One portable, self-contained, FDA-approved device was identified that, from preliminarily assessment, best met these criteria; the device noninvasively applies pulsed shortwave therapy (PSWT) to modify pain signals from peripheral nerves, however, the device has limited battery life and the effects are relatively non-selective in type of neural signal modified. LIMITATIONS This current effort, although extensive, did not identify a comprehensive list of all alternatives for pain treatment. Once the pandemic limitations are lifted, a longer, more thorough effort may find additional options. CONCLUSIONS/IMPLICATIONS The ideal electromagnetic pain treatment device for use on exploration-class spaceflight missions does not yet exist, but it may be available soon. It is not feasible for NASA to develop medical devices due to the schedule constraints for pending exploration-class missions, but adapting a promising device that is already FDA-approved might be an option. Monitoring research that is ongoing at other federal agencies is recommended, and further review of the candidate PSWT device identified in this current effort may be warranted.

C A Mullenax↗