Search NASA⌕ Search

SEARCH · Search NASA

Results for “microbiology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Does Collection Time Bias the Ecology of Cleanroom Air Samples?

Microbial monitoring of astromaterials collections has taken on increased importance with the return of biologically sensitive samples from the asteroids Ryugu and Bennu and the initiation of the Mars Sample Return Program. Terrestrial bacteria and fungi can alter the mineralogy and organic composition of our collections causing irreversible contamination of pristine samples and increasing the risk of false positives for life detection measurements. NASA has conducted routine microbial monitoring of its existing collections since 20181. Initial monitoring focused on surface samples collected with foam swabs. Although, airborne microbiology is often decoupled from surface microbiology in the built environment2 culture-based air sampling techniques like impactors were not compliant with existing contamination control requirements. Bringing organic rich media, gelatin or liquids into curation cleanrooms presents an unacceptable risk to pristine samples. In 2022 NASA purchased a materials complaint air sampler and began collecting air samples from the cleanrooms in addition to surface samples3. The new instrument uses an electret filter to collect samples that are suitable for cultivating organisms or for direct DNA sequencing. Preliminary DNA sequencing results appeared to indicate that longer sampling times biased the microbial community in favor of hearty, spore-forming bacteria3. We present the results of a study comparing overnight sampling (17 hours) to short (1 hour) sampling of unoccupied curation cleanrooms. The results will help us optimize our monitoring protocols and develop a more detailed inventory of the ecology of astromaterials curation cleanrooms. Methods: We analyzed 72 paired air samples from six different cleanrooms including the meteorite processing lab (ISO 7 equivalent, 16 samples), the lunar lab (ISO 6 equivalent, 10 samples), the stardust lab (ISO 5 equivalent 14 samples), the OSIRIS-REx lab (ISO 5 equivalent, 12 samples), the Hayabusa2 lab (ISO 5 equivalent, 14 samples), and the Genesis lab (ISO 4 equivalent, 6 samples). All the samples were collected with an InnovaPrep Bobcat air sampler operating at a sampling rate of 200 L/min. The sampler operates for 5 minutes out of every 20 minute period. Half of the samples were collected by filtering 3,000L (15 min. of active sampling) of air across an electret filter for one hour. The rest of the samples were collected by filtering approximately 51,000 L air across the filter overnight (~17 hours, 255 min. of active sampling). Cells were eluted from the filter using 6-7 ml of pressurized 0.15% tween 20 in PBS (phosphate buffered saline). This liquid was used to cultivate bacteria according to previously published methods1,4,5 and for DNA extraction and next generation sequencing. DNA was extracted with a Qiagen MagAttract PowerMicrobiome kit6. To identify bacteria and archaea, the 16S rRNA gene was amplified using Earth Microbiome primers for the V4 region 7. The amplified DNA was sequenced on an Illumina MiSeq using a V3 reagent kit. The resulting sequences were processed using DADA2 and QIIME2 as implemented on the EDGE bioinformatics platform8–10. Results: Only two of the 72 samples had no amplifiable DNA. Amplified DNA concentrations ranged from 2.67 – 0.272 ng/µl. The median concentration of amplified DNA for the 1 hour samples was 0.770 ± 0.368 ng/µl. The median concentration of amplified DNA for the overnight samples was 0.877 ± 0.434 ng/µl. On average the overnight samples had slightly more sequences (58,960 vs. 59,456) and ASV’s (amplicon sequence variants) (60 vs 64.5) than the one hour samples, but these differences are not statistically significant. The most abundant ASV in every sample mapped to the genus Cupravidus. ASV’s mapping to the genuses Bacillus, Schlegelella, Thermus, and Staphylococcus were also common. Discussion and Future Work: Alpha diversity statistics like Shannon Entropy and Faith Phylogenetic Diversity are used to describe the diversity of organisms in a single sample. If a longer sampling time was biasing the data, we would expect to see a change in these diversity statistics vs. sample time. However, we did not observe this in our data. The median Shannon entropy was slightly higher for the overnight samples (3.773 vs 3.611) as was the Faith Phylogenetic Diversity (4.042 vs 3.596), but both values were within a standard deviation of each other for the two sampling times (Fig. 1). It is unlikely, that the longer sampling time is introducing bias into our data. We do observe a significant decrease in diversity when comparing the air samples by lab. The Genesis lab (ISO 4 equivalent) has a lower median number of ASV’s (45.5) than the other labs (62). Median values for Shannon Entropy (3.717 vs. 3.430) and Faith Phylogenetic Diversity (3.796 vs. 3.548) are also lower for Genesis, but those values are with one standard deviation of each other for the different sampling times. This is consistent with previous culture-based results suggesting that the environment in cleanrooms tends to select for a core group of organisms capable of surviving under dry, low nutrient, conditions. The presence of the ASV’s mapping to Cupravidus and Thermus in our sequencing blanks and controls suggests that several of the most common organisms in our samples represent contaminants from the reagents used to perform the DNA extractions and sequencing. Further work is needed to identify these contaminants, remove them from our data and recalculate the diversity statistics. This is a systematic error. Therefore, we do not expect removing the sequencing contaminants to change our conclusions. Longer air sample collection times appear to result in slightly higher diversity and do not bias the results towards “hardy” bacteria like spore-formers. Based on these preliminary results we conclude that sampling at least 3,000 liters of air is sufficient to capture the microbial diversity of cleanrooms, and that air samples can also be collected overnight without negatively impacting diversity. These results allow us to be flexible when designing microbial monitoring plans so that they do not interfere with routine lab activity. References: 1. Regberg, A. B. et al. 49th Lunar and Planetary Science Conference (2018). 2. The United States Pharmacopeial Convention. USP General Chapter <1116> (2013). 3. Regberg, A. B., et al. 54th Lunar and Planetary Science Conference (2023). 4. Regberg, A. B. et al. 53rd Lunar and Planetary Science Conference ( 2022). 5. Davis, R. E.,et al. 50th Lunar and Planetary Science Conference (2019). 6. Qiagen. MagAttract® PowerMicrobiome® DNA/RNA EP Kit Handbook. (2018). 7. Walters, W. et al. mSystems 1, (2015). 8. Callahan, B. J. et al. Nat. Methods 13, 581–583 (2016). 9. Hall, M. & Beiko, R. G. Microbiome Analysis: Methods and Protocols113–129 (Springer, 2018). 10. Philipson, C. et al. Bio-Protoc. 7, e2622 (2017).

A. B. Regberg↗

ISS External Microorganisms: Collecting Planetary Protection Samples During Extravehicular Activity

Introduction: We have designed1, built, and tested a sampling kit (Fig. 1) to aseptically collect microbiological samples from exterior surfaces on the ISS (International Space Station). The kit was flown to ISS as part of the NG-19 commercial cargo mission in August of 2023. Astronauts will use the kit to collect samples from six exterior surfaces on ISS. These samples will be frozen at -80°C after collection and returned to the ground for next generation DNA sequencing. The results of this experiment will help inform planetary protection requirements for crewed missions. We hypothesize that there are detectable microbial communities outside ISS and that these communities originate from inside ISS. Current life support systems do not include any components for reducing microbial leakage. Gases are vented from inside ISS without filtration and there are currently no protocols in place to minimize bioburden on space suit exteriors prior to use. It is important to quantify the bioburden on current vehicles so that achievable limits can be set for crewed missions to astrobiologically relevant locations like Mars. Figure 1: The sampling kit contains eight swab canisters in total (six on the top and two on the bottom). A resuable end effector (1) is used to remove and reinstall the swabs. The kit also contains a handrail (2), tether loop (3), and, bayonet probes(4) to allow easy manipulation during EVA. Methods: We have designed a kit to carry 8 commercially available foam swabs into and out of vacuum without compromising the swabs’ sterility. The specially designed swab canisters contain a 0.2 µm Teflon filter that allows the canister to accommodate pressure changes without introducing unwanted contaminants. The kit meets existing EVA (Extravehicular Activity) safety requirements and has been used by human test subjects in the neutral buoyance lab and at vacuum in test chambers at the Johnson Space Center. In the early part of 2024, astronauts will use this sampling kit to swab six surfaces on the exterior of ISS. We will collect samples from: the airlock vestibule, the interior surface of the airlock thermal cover, an exterior handrail, a vent connected to the CO2 removal system, and a vent connected to the payload vacuum system inside ISS. Approximately 300 cm2 will be swabbed at each location. A seventh swab will be exposed to the vacuum of space without touching any surfaces as a blank. The eighth swab will remain sealed as a process control. After the EVA the swab kit will be frozen at -80°C and returned to earth at the earliest possible opportunity. The samples will remain frozen until they are thawed for next generation DNA sequencing on earth. We will use amplicon sequencing to identify any bacteria, archaea or fungi present in the samples. If there is enough DNA present, we will use shotgun metagenomic sequencing to further characterize the microbial ecology outside ISS. Preliminary Results: Results from ground-based testing demonstrate that the swab kit is capable of cycling in and out of vacuum without contaminating the swabs. Test subjects, wearing flight-like EVA gloves could remove swabs from the canister and sample discrete locations without inadvertently touching any other surfaces. Several types of bacteria and fungi were collected during these ground tests and survived up to 6 hours at vacuum. This includes non-spore forming bacterial like Staphyloccus capitis that are not traditionally considered extremophiles. Shotgun metagenomic sequencing of the ground-test samples revealed bacteria associated with human skin and airways on the exterior of space suits used during these tests 2 In addition to these results we will present preliminary results from our space-flight samples. We will also present lessons learned from attempting to collect microbiological samples during an EVA and describe how our results will affect planetary protection requirements for future crewed missions.

Aaron B. Regberg↗

Mars Sample Return: Risk Management & Sample Safety Assessment

Returning samples from Mars has long been a major planetary science objective due to the high scientific value and transformative potential of the resulting data. An exciting dimension of this objective is the potential for the detection of ancient microbiological life, and the possibility of improving our understanding of the evolution of habitable environments on Mars and the development of life on Earth. To ensure that returned samples meet stringent planetary protection requirements and do not expose Earth to potential biohazards, the joint NASA/ESA Sample Receiving Project (SRP) assembled the Sample Safety Assessment Protocol Tiger Team (SSAP-TT). Members were recruited with the specific goal of creating a multi-disciplinary and internationally distributed team of experts in their respective fields across the federal government, academia, and private industry. This team was chartered with reassessing previous sample safety assessment strategies, defining what constitutes a biological hazard, developing a protocol to test for potential biohazards, and establishing a statistical framework to determine if samples are “safe” for release. The team developed a three-step protocol, supported by a Bayesian statistical framework, to assess whether returned samples contain potential biohazards that could present a risk to Earth’s biosphere. Initial conclusions indicated that an effective and comprehensive safety assessment protocol is feasible using modern techniques and does not require an excessive amount of sample consumption or traditional microbiological detection methodology. Herein, we will present an overview of the MSR SRP, the proposed safety assessment protocol, and how aspects of this novel approach can be applied to biological assessment in healthcare product manufacturing practices.

Alvin L Smith↗

A geostatistical analysis of small-scale spatial variability in bacterial abundance and community structure in salt marsh creek bank sediments

Small-scale variations in bacterial abundance and community structure were examined in salt marsh sediments from Virginia's eastern shore. Samples were collected at 5 cm intervals (horizontally) along a 50 cm elevation gradient, over a 215 cm horizontal transect. For each sample, bacterial abundance was determined using acridine orange direct counts and community structure was analyzed using randomly amplified polymorphic DNA fingerprinting of whole-community DNA extracts. A geostatistical analysis was used to determine the degree of spatial autocorrelation among the samples, for each variable and each direction (horizontal and vertical). The proportion of variance in bacterial abundance that could be accounted for by the spatial model was quite high (vertical: 60%, horizontal: 73%); significant autocorrelation was found among samples separated by 25 cm in the vertical direction and up to 115 cm horizontally. In contrast, most of the variability in community structure was not accounted for by simply considering the spatial separation of samples (vertical: 11%, horizontal: 22%), and must reflect variability from other parameters (e.g., variation at other spatial scales, experimental error, or environmental heterogeneity). Microbial community patch size based upon overall similarity in community structure varied between 17 cm (vertical) and 35 cm (horizontal). Overall, variability due to horizontal position (distance from the creek bank) was much smaller than that due to vertical position (elevation) for both community properties assayed. This suggests that processes more correlated with elevation (e.g., drainage and redox potential) vary at a smaller scale (therefore producing smaller patch sizes) than processes controlled by distance from the creek bank. c2002 Federation of European Microbiological Societies. Published by Elsevier Science B.V. All rights reserved.

Non-NASA Center↗

Contamination analysis and monitoring

"Sterilization" is a term applied to any process or procedure that produces a condition of sterility. Sterility is an absolute concept and refers to the destruction or removal of all life. However, when sterility as an absolute concept is applied to the sterilization of space hardware, it ceases to be operational. Absolute proof of sterility of flight hardware is impossible. Hence, for an operational approach to certification of sterility of space hardware, it is necessary to apply the probability concept. The present report is concerned with the applicability of mathematics to predict the probability of achieving sterility in a complex space hardware system. As such, this approach is concerned with the manipulation of microbiological data rather than mathematical rigor.

contamination↗

Apollo-Soyuz Test Project: Preliminary Science Report

This document summarizes the experimental concepts and preliminary analyses (as of December 1975) for each of the 28 scientific experiments conducted during the Apollo-Soyuz Test Project from July 15 to 24, 1975. The scientific topics are X- ray and extreme ultraviolet astronomy, solar astronomy, gamma- ray detectors, Earth studies (including the upper atmosphere, meteorological phenomena, hydrology, oceanography, geology, desert studies, and gravity field studies), microbiology, heavy cosmic particle interaction with live cells, vestibular system studies, and materials processing (including high-temperature and ambient-temperature processing of industrial materials and electrophoretic processing of biological materials) .

Orbital science↗