Search NASA⌕ Search

SEARCH · Search NASA

Results for “motor control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Design of a Mode Conversion Ultrasonic Motor for Position Control

The many useful characteristics of ultrasonic motors, such as high holding torques, and high torque at low speeds, have made them the subject of increasing interest. In addition, several of their characteristics make them attractive for aerospace applications: they have a torque to weight ratio, and they require neither gearing mechanisms nor lubrication. Moreover, they create negligible magnetic fields, and conversely, they are not affected by external magnetic fields. Ultrasonic motors based on bolt-tightened structures offer simplicity and high stress capability. They use the inverse piezoelectric effect in the stator to produce vibrational energy, which is transferred to the rotor by friction. We designed a bolt-tightened ultrasonic motor using numerical modelling tools (finite element and electromechanical circuit analyses), creating an equivalent circuit model that takes into account the electromechanical energy conversion in the stator and the contact between the stator and the rotor. Analysis of the circuit gives insight into the behavior of the motor and allows its performance to be calculated. Two prototypes of the motor were built; their transient responses and other quantities, such as starting torque, were measured. In this paper, we discuss the numerical and the experimental results, and demonstrate the usefulness of numerical analysis in designing ultrasonic motors and estimating their performance.

LeLetty, Ronan↗

Domain Compilation for Embedded Real-Time Planning

A recently conceived approach to automated real-time control of the actions of a robotic system enables an embedded real-time planning algorithm to develop plans that are more robust than they would otherwise be, without imposing an excessive computational burden. This approach occupies a middle ground between two prior approaches known in the art as the universal-plan and hybrid approaches. Ever since discovering the performance limitations of taking a sense-plan-act approach to controlling robots, the robotics community has endeavored to follow a behavior-based approach in which a behavior includes a rapid feedback loop between state estimation and motor control. Heretofore, system architectures following this approach have been based, variously, on algorithms that implement universal plans or algorithms that function as hybrids of planners and executives. In a typical universal-plan case, a set of behaviors is merged into the plan, but the system must be restricted to relatively small problem domains to avoid having to reason about too many states and represent them in the plan. In the hybrid approach, one implements actions as small sets of behaviors, each applicable to a limited set of circumstances. Each action is intended to bring the system to a subgoal state. A planning algorithm is used to string these actions together into a sequence to traverse the state space from an initial or current state to a goal state. The hybrid approach works well in a static environment, but it is inherently brittle in a dynamic environment because a failure can occur when the environment strays beyond the region of applicability of the current activity. In the present approach, a system can vary from the hybrid approach to the universal-plan approach, depending on a single integer parameter, denoted n, which can range from 1 to a maximum domain-dependent value of M. As illustrated in the figure, n = 1 represents the hybrid approach, in which each linked action covers a small part of the state space of the system. As n increases, the portion of state space associated with each action and its subgoal grows. When n reaches M, coverage extends over the full state space, so that the system contains a universal plan.

Barrett, Anthony↗

Altered sensorimotor control of the body as an etiological factor in space motion sickness

Exposure to nonterrestrial force levels affects the activity of gravitoinertial force sensitive receptors of the body, both of labyrinthine and nonlabyrinthine origin. It also disrupts the normal patterning of motor control of body orientation and movement. The patterns and levels of muscle innervation necessary to achieve particular body configurations and to bring about particular body movements are greatly affected by background force level and body orientation relative to the force vector. The present studies demonstrate that such altered sensorimotor control of head and body posture along with altered vestibulomotor control are evocative of motion sickness. This observation has explanatory significance both for space motion sickness and the re-entry disturbances that occur after prolonged spaceflight.

Lackner, James R.↗

Alternating-pulse iontophoresis for targeted cutaneous anesthesia

In studies of sensory contributions to motor control, it may be advantageous to temporarily reduce the sensitivity of specific sensory systems. This article details a method for non-invasively inducing cutaneous anesthesia, leaving proprioceptive and motor functions intact. This method, called alternating-pulse iontophoresis, differs from conventional direct-current (DC) iontophoretic drug delivery in that adjacent drug delivery electrodes are stimulated out-of-phase. The total current delivered at any instant is then less than that produced during a comparable DC application, while the uniformity of drug delivery is expected to improve. Effective delivery of local anesthetics to the cutaneous foot soles by alternating-pulse iontophoresis was demonstrated using cutaneous pressure sensory threshold levels (STL's) assessed with Semmes-Weinstein monofilaments (arbitrary units of perceived force, or a.u.). Thirteen of 16 healthy subjects achieved a level of anesthesia greater than or equal to that normally associated with clinical peripheral sensory neuropathy. Average STL's measured prior to the anesthesia procedure were 4.00 a.u. ( approximately 10 mN). Immediately following the procedure, STL's were elevated to an average of 5.40 a.u. ( approximately 246 mN) and averaged 4.97 a.u. ( approximately 92 mN) after 50 min of standing. A number of research and clinical applications for this technique are suggested.

Non-NASA Center↗

Low speed phaselock speed control system

A motor speed control system for an electronically commutated brushless dc motor is provided which includes a phaselock loop with bidirectional torque control for locking the frequency output of a high density encoder, responsive to actual speed conditions, to a reference frequency signal, corresponding to the desired speed. The system includes a phase comparator, which produces an output in accordance with the difference in phase between the reference and encoder frequency signals, and an integrator-digital-to-analog converter unit, which converts the comparator output into an analog error signal voltage. Compensation circuitry, including a biasing means, is provided to convert the analog error signal voltage to a bidirectional error signal voltage which is utilized by an absolute value amplifier, rotational decoder, power amplifier-commutators, and an arrangement of commutation circuitry.

Fulcher, R. W.↗

A robotic wheelchair

Many people who are mobility impaired are incapable, for a variety of reasons, of using an ordinary wheelchair. These people must rely on either a power wheelchair, which they control, or another person to push and guide them while they are in an ordinary or power wheelchair. Power wheelchairs can be difficult to operate. If a person has additional disabilities, either in perception or fine motor control of their hands, a power chair can be difficult or impossible for them to use safely. Having one person push and guide a person who is mobility impaired is very expensive, and if the disabled person is otherwise independent, very inefficient and frustrating. This paper describes a low-cost robotic addition to a power wheelchair that assists the rider of the chair in avoiding obstacles, going to pre-designated places, and maneuvering through doorways and other narrow or crowded areas. This system can be interfaced to a variety of input devices, and can give the operator as much or as little moment by moment control of the chair as they wish.

Miller, David P.↗

Software Development for the Hobby-Eberly Telescope's Segment Alignment Maintenance System using LABView

The software development for an upgrade to the Hobby-Eberly Telescope (HET) was done in LABView. In order to improve the performance of the HET at the McDonald Observatory, a closed-loop system had to be implemented to keep the mirror segments aligned during periods of observation. The control system, called the Segment Alignment Maintenance System (SAMs), utilized inductive sensors to measure the relative motions of the mirror segments. Software was developed in LABView to tie the sensors, operator interface, and mirror-control motors together. Developing the software in LABView allowed the system to be flexible, understandable, and able to be modified by the end users. Since LABView is built using block diagrams, the software naturally followed the designed control system's block and flow diagrams, and individual software blocks could be easily verified. LABView's many built-in display routines allowed easy visualization of diagnostic and health-monitoring data during testing. Also, since LABView is a multi-platform software package, different programmers could develop the code remotely on various types of machines. LABView s ease of use facilitated rapid prototyping and field testing. There were some unanticipated difficulties in the software development, but the use of LABView as the software "language" for the development of SAMs contributed to the overall success of the project.

Hall, Drew P.↗

Cybernetic prosthesis

Design and development of a prosthetic device fitted to an above elbow amputee is reported that derives control information from the human to modulate power to an actuator to drive the substitute limb. In turn, the artificial limb generates sensory information feedback to the human nervous system and brain. This synergetic unity feeds efferent or motor control information from the human to the machine, and the machine responds, delivering afferent or sensory information back to the man.

Mann, R. W.↗

Portable Pull Tester

In new tester, dc motor controlled by personal computer drives lead screw. Lead screw attached to load cell and to test button bonded to specimen of material under test. Data examined on computer screen, printed out, or transmitted to larger computer for analysis. Monitors speed of motor to maintain it constant, provides constant rate of pull. Cart holds computer, printer, and motor-driving circuits so moved easily to test site.

Golden, Harry E.↗

Design and Development of an Aircraft Electric Powertrain Test Stand

Recent advancements in battery technology and power electronics are enabling novel approaches to powered flight that rely on fully electric or hybrid-electric powertrain systems. To mitigate the risk surrounding such unproven systems, it is necessary to characterize their performance on a component-wide and system-wide basis. In this paper, we discuss the design and development of an electric powertrain test stand that can collect high-fidelity data of motor, controller, and battery performance, thereby allowing us to determine system performance, efficiencies, and thermal characteristics.

test stand↗

Electronic systems for the new multichannel spectrometer at Sacramento Peak.

Description of the design features and operation of a new multichannel solar spectrometer to be used for ground-based observations of active regions whose X-ray and EUV emissions are studied by the OSO-H and other satellites. The electronic systems associated with the instrument include (1) an electrooptical guider controlled by a punched paper tape capable of making raster scans of selected portions of the solar disk, (2) a programmer unit that applies paper-tape commands to various portions of the instrument, (3) a closed-loop servosystem for the vacuum heliostat, (4) stepping motor controls for spectral scans, (5) a 40-channel photomultiplier readout, and (6) a magnetometer. Preliminary solar observations indicate satisfactory performance of the system.

Hobbs, R. W.↗

Powerline Coupler for Windmill Motor/Generators

Efficiency at low windspeed increased by firing-angle control. Power coupled from wind-driven induction motor/generator to ac powerline with help from circuit. Circuit reduces power consumed by field windings thereby improving efficiency at low windspeeds. Circuit includes zerocrossing detector, ramp generator and comparator similar to those used to set firing angles for thyristors in power factor motor controllers.

Nola, F.↗

Developing Humanoid Robots for Real-World Environments

Humanoids are steadily improving in appearance and functionality demonstrated in controlled environments. To address the challenges of operation in the real-world, researchers have proposed the use of brain-inspired architectures for robot control, and the use of robot learning techniques that enable the robot to acquire and tune skills and behaviours. In the first part of the paper we introduce new concepts and results in these two areas. First, we present a cerebellum-inspired model that demonstrated efficiency in the sensory-motor control of anthropomorphic arms, and in gait control of dynamic walkers. Then, we present a set of new ideas related to robot learning, emphasizing the importance of developing teaching techniques that support learning. In the second part of the paper we propose the use in robotics of the iterative and incremental development methodologies, in the context of practical task-oriented applications. These methodologies promise to rapidly reach system-level integration, and to early identify system-level weaknesses to focus on. We apply this methodology in a task targeting the automated assembly of a modular structure using HOAP-2. We confirm this approach led to rapid development of a end-to-end capability, and offered guidance on which technologies to focus on for gradual improvement of a complete functional system. It is believed that providing Grand Challenge type milestones in practical task-oriented applications accelerates development. As a meaningful target in short-mid term we propose the 'IKEA Challenge', aimed at the demonstration of autonomous assembly of various pieces of furniture, from the box, following included written/drawn instructions.

Stoica, Adrian↗

The 15-meter antenna performance optimization using an interdisciplinary approach

A 15-meter diameter deployable antenna has been built and is being used as an experimental test system with which to develop interdisciplinary controls, structures, and electromagnetics technology for large space antennas. The program objective is to study interdisciplinary issues important in optimizing large space antenna performance for a variety of potential users. The 15-meter antenna utilizes a hoop column structural concept with a gold-plated molybdenum mesh reflector. One feature of the design is the use of adjustable control cables to improve the paraboloid reflector shape. Manual adjustment of the cords after initial deployment improved surface smoothness relative to the build accuracy from 0.140 in. RMS to 0.070 in. Preliminary structural dynamics tests and near-field electromagnetic tests were made. The antenna is now being modified for further testing. Modifications include addition of a precise motorized control cord adjustment system to make the reflector surface smoother and an adaptive feed for electronic compensation of reflector surface distortions. Although the previous test results show good agreement between calculated and measured values, additional work is needed to study modelling limits for each discipline, evaluate the potential of adaptive feed compensation, and study closed-loop control performance in a dynamic environment.

Grantham, William L.↗

Prediction of propellant behavior in spinning flow of a space motor

A model for 2-phase flow dynamics in a spinning spherical rocket motor, developed for the Ofeq satellite program, is based on the sectional approach to solution of the flow equations. An experimental model was built, to enable the motion of the aluminum/aluminum-oxide particles resulting from combustion within a solid-fuel motor to be simulated by injected paraffin droplets. The injected droplets included under-5 micrometer droplets which move with the gas stream and larger droplets, averaging 20 micrometer diameter, which simulate the motion of aluminum particles. The test chamber comprised a pair of cylindrical pyrex tubes with a sharp contraction in diameter, rotated at various speeds by a frequency-controllable motor. An optical system, based on a 5 W argon ion laser with a beam splitter and frequency shifter, mounted on a movable table, facilitated sectional measurements of the three velocity components and determination of size-velocity relationships. Preliminary results indicate that the effect of rotation on axial velocity is negligible, while its effect on tangential velocity approximates to solid-body rotation.

Gany, A.↗

Vestibular autonomic regulation (including motion sickness and the mechanism of vomiting)

Autonomic manifestations of vestibular dysfunction and motion sickness are well established in the clinical literature. Recent studies of 'vestibular autonomic regulation' have focused predominantly on autonomic responses to stimulation of the vestibular sense organs in the inner ear. These studies have shown that autonomic responses to vestibular stimulation are regionally selective and have defined a 'vestibulosympathetic reflex' in animal experiments. Outside the realm of experimental preparations, however, the importance of vestibular inputs in autonomic regulation is unclear because controls for secondary factors, such as affective/emotional responses and cardiovascular responses elicited by muscle contraction and regional blood pooling, have been inadequate. Anatomic and physiologic evidence of an extensive convergence of vestibular and autonomic information in the brainstem suggests though that there may be an integrated representation of gravitoinertial acceleration from vestibular, somatic, and visceral receptors for somatic and visceral motor control. In the case of vestibular dysfunction or motion sickness, the unpleasant visceral manifestations (e.g. epigastric discomfort, nausea or vomiting) may contribute to conditioned situational avoidance and the development of agoraphobia.

Review, Tutorial↗

Locomotor head-trunk coordination strategies following space flight

During locomotion, angular head movements act in a compensatory fashion to oppose the vertical trunk translation that occurs during each step in the gait cycle. This coordinated strategy between head and trunk motion serves to aid gaze stabilization and perhaps simplifies the sensory coordinate transformation between the head and trunk, allowing efficient descending motor control during locomotion. Following space flight, astronauts often experience oscillopsia during locomotion in addition to postural and gait instabilities, suggesting a possible breakdown in head-trunk coordination. The goal of the present investigation was to determine if exposure to the microgravity environment of space flight induces alteration in head-trunk coordination during locomotion. Astronaut subjects were asked to walk (6.4 km/h, 20 s trials) on a motorized treadmill while visually fixating on a centrally located earthfixed target positioned either 2 m (FAR) or 30 cm (NEAR) from the eyes. In addition, some trials were also performed during periodic visual occlusion. Head and trunk kinematics during locomotion were determined with the aid of a video-based motion analyzing system. We report data collected preflight (10 days prior to launch) and postflight (2 to 4 hours after landing). The coherence between pitch head and vertical trunk movements during gaze fixation of both FAR and NEAR targets was significantly reduced following space flight indicating decreased coordination between the head and trunk during postflight locomotion. Astronauts flying on their first mission showed greater alterations in the frequency spectra of pitch head movements as compared to their more experienced counterparts. These modifications in the efficacy of head movement control may account for the reported disruption in gaze performance during locomotion and may contribute to postflight postural and gait dysfunction.

NASA Discipline Neuroscience↗

Resonant mode controllers for launch vehicle applications

Electro-mechanical actuator (EMA) systems are currently being investigated for the National Launch System (NLS) as a replacement for hydraulic actuators due to the large amount of manpower and support hardware required to maintain the hydraulic systems. EMA systems in weight sensitive applications, such as launch vehicles, have been limited to around 5 hp due to system size, controller efficiency, thermal management, and battery size. Presented here are design and test data for an EMA system that competes favorably in weight and is superior in maintainability to the hydraulic system. An EMA system uses dc power provided by a high energy density bipolar lithium thionyl chloride battery, with power conversion performed by low loss resonant topologies, and a high efficiency induction motor controlled with a high performance field oriented controller to drive a linear actuator.

Schreiner, Ken E.↗